Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow around a building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Tackling the Giants: Applying Smart Labs Principles to Constant Air Volume Lab Buildings

Laboratories typically consume 3 to 10 times more energy than similarly sized commercial buildings, and as much as 50% of that energy is wasted by inefficient and poorly operating fume hoods and ventilation systems. One challenge faced by older laboratory buildings is the heating, ventilation, and air-conditioning systems serving many of these buildings. The older systems are usually constant air volume (CAV) systems that maintain constant ventilation rates that cause excess airflow and inefficient energy use. Variable air volume systems can be more efficient systems with sensors to detect the need for a change in volumetric flow rate; however; renovation of ventilation systems can create disruption to ongoing research and operations along with considerable up-front costs. When a Smart Labs program is implemented, an organization has a systems-based management approach that yields a high-performing laboratory building. As decarbonization continues as a priority for sites, buildings with CAV systems are difficult to address. This work centers around practical guidance for improving lab buildings with CAV. In conjunction with industry input on top technology solutions and best practices, recommendations will include performing a laboratory ventilation risk assessment in conjunction with robust retro-commissioning work, which is a crucial step in the Smart Lab process. By applying Smart Labs principles, the aging laboratory building stock of 153,343 (Lawrence Berkeley National Laboratory [LBNL] 2017), comprising roughly 500,000 lab spaces in the United States, can be brought to safe and high-performance operations.

building↗

Throughput Measurements and Profile Analysis of Cloud Networks

Cloud networks utilize virtual connections to connect virtual machines distributed across cloud sites. They are increasingly deployed due to flexible provisioning using software and cost-effectiveness in not requiring to build physical network infrastructure. However, their extensive virtualization makes it unclear how well the established practices of conventional networks translate to them. Here, we study throughput measurements over a Google Cloud network using a matching hardware emulated conventional network, which provide production and exploratory conditions, respectively. The measurements span connections representing local, cross-continental and around the Earth distances. We study the effects of parallel flows, congestion control algorithms and retransmissions on the network throughput profile expressed as a function of RTT. We compare the throughput profile of Google Cloud network with those of emulated network under various loss conditions, including those too disruptive or expensive in the former. Our analysis based on the concave-convex shape and utilization-concavity coefficients of throughput profiles indicates an overall agreement of performance between the two networks, thereby justifying the use of conventional network emulations to analyze cloud networks. In terms of practical use, our study establishes that BBR and BBRv2 alpha TCP achieve higher throughput compared to loss-based congestion control algorithms under most network configurations, especially, under losses at large RTT.

Phanekham, Derek [Southern Methodist Univ., Dallas↗

Quantifying Leak Rates and Vacuum Impact on Granular Soil Column Pneumatic Seal

Introduction: All In-Situ Resource Utilization (ISRU) regolith reactor systems that aim to extract gases or vapors must maintain a seal along the flow path of the regolith from the inlet hopper to where extracted gases or vapors are generated. Using a column of regolith at the inlet has been proposed as an alternative to systems using series of mechanical valves to reduce mass and complexity. Preliminary investigations into the use of regolith itself as a barrier to escaping fluids have been conducted, which this research seeks to expand upon. Different vertical regolith simulant plug diameters and heights were tested under vacuum with dry nitrogen to observe leak rates and approximate steady state pressure gradient equilibria. The effect of absolute ambient pressure was also studied by repeating tests at incremental pressures ranging from 10e-5 Torr up to 1 atm to corroborate ambient bench tests from previous work. The impact of regolith dynamics was addressed to emulate continuous-feed regolith reaction processes by measuring leak rates through continuously draining simulant columns. OB-1 lunar highlands regolith simulant was used. Experimental Setup: Regolith simulant columns were constructed using a motorized butterfly valve separating upper acrylic tubes of various diameters from a larger, lower aluminum pipe plenum (See Figure 1). The butterfly valve was cracked open such that gas could freely pass through whereas regolith would bridge and stay suspended as a cohesive plug above in the acrylic portion. These assemblies were loaded into a vacuum chamber, and a compressed dry nitrogen line was routed into the lower plenum. Pressure transducers measured the absolute pressure of the lower plenum, which was compared to absolute chamber pressure to monitor the pressure gradient across the regolith simulant. A precision mass flow controller enabled fine control of plenum pressure. The plenum pressure was quasi-statically increased to set points informed by previous work [1] before shutting off the gas supply to allow the now pressurized gas volume to dissipate through the simulant into the chamber in what was referred to as a ‘leak test.’ In a separate set of tests, the pressure was allowed to quasi-statically build until visual disturbances in the soil were observed via remote camera feeds. Initial leak rate tests were repeated on the disturbed soil to observe changes in leak rates between initial as-poured and post-bubbling soil conditions. This test schedule was applied to simulant columns of three different diameters (approximately 2, 4, and 6 inches) as well as two different heights (around 8 and 16 inches) and was repeated at least three times for each configuration. Plenums were also pressurized while the butterfly valves were opened slightly further to facilitate slow, controlled, constant flowrate draining of the simulant to observe the impact that continuous-feed systems might have on leak rate through the regolith column. Finally, the regolith columns were reset and refilled and static leak rate tests were repeated approximately every decade in ambient pressure from 10e-5 Torr up to ambient conditions to observe the impact of transitioning out of the molecular flow regime on regolith column seal performance. Analysis: Trends with respect to each factor examined were constructed and reported alongside commentary on the most likely responsible physical phenomena. Confidence intervals were applied to the predictive findings of the data by quantifying instrumentation error and accounting for probabilistic impacts of curve fitting the generic exponential function onto pressure decay data. The leak rate is assumed directly proportional to the exponential term coefficient, while the steady-state static pressure gradient is assumed to be the asymptotic limit of each curve fit. Finally, a generic model developed by Ogino et al. [2] and later tuned for ambient testing was re-tuned using vacuum data to estimate leak rates on the lunar surface. Results: Pressure decay rates decreased up to 27-fold under vacuum when compared to ambient pressure, as shown in Figure 2. Simulant column diameter was found to exponentially correlate to both regolith column leak rate and steady-state equilibrium pressure delta. Height was found to be linearly related to leak rate –doubling the regolith column height consistently yielded around a 40% reduction in leak rate. Dynamic regolith draining was found to slightly increase leak rate, although to a lower degree than expected. Conclusion: Because of the transition into molecular gas flow through regolith, vacuum testing is required to properly estimate performance. Regolith columns should be designed as narrow as possible to avoid bridging and minimize leak rate, and as tall as is feasible to both further reduce leak rate and to help prevent bubbling, which has been shown to degrade the quality of the regolith seal. Disrupted soil was found to exhibit higher leak rates than pristine, as-poured soil, indicating the need to consider the impact of recovery from depressurization events. Regolith columns appear equally feasible for both dosed and continuous-feed reactors.

ISRU↗

On the aerodynamics and performance of active vortex generators

As a building block in the development of smart lift-enhancement devices, a new concept for flow control using active vortex generators (AVGs) is presented. Ramp, wedge, and doublet wedge (Wheeler) VG configurations are investigated. The AVGs are designed to conform to the surface of the wing section at low alpha. As the section approaches the stall, they are deployed and accordingly, alpha(stall) and C(lmax) are increased. A qualitative analysis of the flow around the various VG configurations was conducted in a low speed wind tunnel at 1.6 ft/s and a Reynolds number of approximately 3400. The results demonstrate that ramp VGs produce vortices that have the longest distance at breakdown. The VGs were also applied to a 25-in. span, 8-in. chord NACA 4415 wing section. Optimization studies were conducted on the spanwise spacing, chordwise position, and size of statically deployed VGs. The test results demonstrate a 14-percent increase in C(lmax) while increasing alpha (stall) by up to 3.

Barrett, Ron↗

A Scalable Compact Additively Manufactured Molten Salt to Supercritical Carbon Dioxide Heat Exchanger for Solar Thermal Application

Design of an additively manufactured molten salt (MS) to supercritical carbon dioxide (sCO 2 ) primary heat exchanger (PHE) for solar thermal power generation is presented. The PHE is designed to handle temperatures up to 720 °C on the MS side and an internal pressure of 200 bar on the sCO 2 side. In the core, MS flows through a three-dimensional periodic lattice network, while sCO 2 flows within pin arrays. The design includes integrated sCO 2 headers located within the MS flow, allowing for a counterflow design of the PHE. The sCO 2 headers are configured to enable uniform flow distribution into each sCO 2 plate while withstanding an internal pressure of 200 bar and minimizing obstruction to the flow of MS around it. The structural integrity of the design is verified on additively manufactured (AM) 316 stainless steel sub-scale specimens. An experimentally validated, correlation-based sectional PHE core thermofluidic model is developed to study the impact of flow and geometrical parameters on the PHE performance, with varied parameters including the mass flowrate, surface roughness, and PHE dimensions. A process-based cost model is used to determine the impact of parameter variation on build cost. The model results show that a heat exchanger with a power density of 18.6 MW/m 3 (including sCO 2 header volume) and effectiveness of 0.88 can be achieved at a heat capacity rate ratio of 0.8. As a result, the impact of design and AM machine parameters on the cost of the PHE are assessed.

14 SOLAR ENERGY↗

Effect of chemical heat release in a temporally evolving mixing layer

Two-dimensional numerical simulations of a temporally evolving mixing layer with an exothermic infinitely fast diffusion flame between two unmixed reactants have been carried out in the limit of zero Mach number to study the effect of the heat release on the early stages of the evolution of the flow. Attention has been directed to relatively large values of the oxidizer-to-fuel mass stoichiometric ratio typical of hydrocarbon flames, and initial vorticity distributions thicker than the temperature and species distributions have been chosen to mimic the situation at the outlet of a jet. The results show that, during the stages of the evolution covered by the present simulations, enhancement of combustion occurs by local stretching of the flame without much augmentation of its area. The rate of product generation depends strongly on the initial conditions, which suggests the possibility of controlling the combustion by acting on the flow. Rollup and vortex amalgamation still occur in these reacting flows but are very much affected by the production of new vorticity by baroclinic torques. These torques lead to counter rotating vortex pairs around the flame and, more importantly, in thin layers of light fluid that leave the vicinity of the flame when the Kelvin-Helmholtz instability begins to develop. Propelled by the vortex pairs, these layers wind around, split on reaching high pressure regions, and originate new vortex pairs in a process that ends up building large-scale vortices with a vorticity distribution more complex than for a constant density fluid.

Higuera, F. J.↗

Deep Learning–Assisted Multiobjective Optimization of Geological CO 2 Storage Performance under Geomechanical Risks

In geological CO 2 storage, designing the optimal well control strategy for CO 2 injection to maximize CO 2 storage while minimizing the associated geomechanical risks is not trivial. This challenge arises due to pressure buildup, CO 2 plume migration, the highly nonlinear nature of geomechanical responses to rock-fluid interaction, and the high computational cost associated with coupled flow and geomechanics simulations. In this paper, we introduce a novel optimization framework to address these challenges. The optimization problem is formulated as follows: maximize total CO 2 storage while minimizing geomechanical risks by adjusting the injection schedules within bounded constraints. The geomechanical risks are primarily driven by injection-induced pressure build-up, which is characterized by ground displacement and the induced microseismicity. We used the Fourier neural operator (FNO)-based deep learning model to construct surrogate models, replacing the time-consuming coupled flow and geomechanics simulations for evaluating the aforementioned objective functions. The developed surrogate models have been incorporated into a multiobjective optimization framework through a genetic algorithm to reduce the computational burden. The proposed optimization framework reduces the computational cost from approximately 2,400 hours, when using objective function evaluations based on physics-based simulations, to around 20 minutes. A set of Pareto-optimal solutions of the proposed workflow yields nontrivial optimal decisions, reducing the microseismicity potential and the vertical displacement. This Pareto front highlights the optimal trade-offs between CO 2 storage amount, safety, and ground displacement, emphasizing the need for careful optimization and management of injection strategies to achieve a balanced outcome. The novelty of this work is twofold. First, we demonstrate the importance of incorporating the minimization of the geomechanical risks as objective functions into the CO 2 storage optimization workflow to mitigate the potential risk of induced microseismicity and ground displacement. Second, we leverage the FNO-based surrogate models to optimize a real-field CO 2 storage operation.

42 ENGINEERING↗

Hybrid geological modeling: Combining machine learning and multiple-point statistics

Accurately modeling and constructing a geologically realistic subsurface model remains an outstanding problem as the morphology controls the flow behaviors. Particularly, one of the pattern-based methods, namely cross-correlation based simulation, has been proved to be an effective way to reconstruct a realistic model, at both small and large scales. However, conditioning to point data in the large-scale problems is still a crucial issue in these algorithms, since there is always a trade-off between the quality of the realizations and the degree of point data reproduction. Specifically, it is not practical to build a training image (TI) which includes all the possibilities and variabilities. Therefore, finding a pattern that can represent the point data and, at the same time, preserving the connectivities is difficult. This leads to producing highly-connected realizations with a significant mismatch or poor models with a reasonable degree of point data reproduction. To accurately reproduce the densely distributed hard data, pixel-based methods can also produce some unrealistic artifacts around the hard data. In this paper, to overcome this challenge, however, we use pattern-based methods as they often produce more disconnected geobodies when dealing with dense hard data, and proposed a hybrid algorithm using the pattern-based methods and convolutional neural network (CNN). The trained CNN model is utilized to improve the quality of conditioning to point data for the original realizations generated by the pattern-based algorithm. As such, the mismatch locations are identified, and the same regions are used in the training of CNN to mimic the procedure through which a missing region can be filled. To evaluate the performance of the proposed hybrid algorithm, it is tested on cases with different dimensions and different numbers of facies. Then, the newly improved realizations are compared with the initial realizations generated by the pattern-based algorithm. The comparison is also conducted by the flow simulation test. And it indicates that the proposed hybrid algorithm can better reproduce the point data, while the connectivities are better preserved.

58 GEOSCIENCES↗

Solid-State Thermodynamic Vent System for Control of Cryogenic Propellants

A Solid-State Thermodynamic Vent System (STVS) is a novel Cryogenic Fluid Management (CFM) technology for spacecraft cryogenic propellant tanks that may reduce boiloff while providing greater control over the propellent condition. By exploiting the vacuum-induced cryocooling potential of cryogen-saturated silica aerogel material, an internal STVS heat exchanger expels some sacrificial cryogenic propellant to the vacuum of space to produce cooling within the storage tank. This cooling is transferred directly to the stored fluid, thereby reducing boiloff and increasing hold times. The primary STVS project objective was to design and build a bespoke STVS heat exchanger that employed aerogel blanket material and perform a ground demonstration of the technology using liquid nitrogen (LN2) as the cryogenic propellant. This demonstration aimed to prove that an STVS can have a positive influence on the tank boiloff, shown through a reduction in mass flow rate out of the system during operation, and exercise control over the tank pressure. Testing proved the effectiveness of the concept by reducing the LN2 boiloff rate and tank pressure by roughly 70% and 77% respectively during a single pump-down cycle, which sacrificed around 1.8 kg of propellant.

Propellant Production↗

Preliminary large-eddy simulations of flow around a NACA 4412 airfoil using unstructured grids

Large-eddy simulation (LES) has matured to the point where application to complex flows is desirable. The extension to higher Reynolds numbers leads to an impractical number of grid points with existing structured-grid methods. Furthermore, most real world flows are rather difficult to represent geometrically with structured grids. Unstructured-grid methods offer a release from both of these constraints. However, just as it took many years for structured-grid methods to be well understood and reliable tools for LES, unstructured-grid methods must be carefully studied before we can expect them to attain their full potential. In the past two years, important building blocks have been put into place making possible a careful study of LES on unstructured grids. The first building block was an efficient mesh generator which allowed the placement of points according to smooth variation of physical length scales. This variation of length scales is in all three directions independently, which allows a large reduction in points when compared to structured-grid methods, which can only vary length scales in one direction at a time. The second building block was the development of a dynamic model appropriate for unstructured grids. The principle obstacle was the development of an unstructured-grid filtering operator. In the past year, some of the new filters developed by Jansen have been implemented into a highly parallelized finite element code based on the Galerkin/least-squares finite element method. We have chosen the NACA 4412 airfoil at maximum lift as the first simulation for a variety of reasons. First, it is a problem of significant interest since it would be the first LES of an aircraft component. Second, this flow has been the subject of three experimental studies. The third reason for considering this flow is the variety of flow features which provide an important test of the dynamic model. Only the dynamic model can be expected to perform satisfactorily in this variety of situations: from the laminar regions where it must not modify the flow at all to the turbulent boundary layers and wake where it must represent a wide variety of subgrid-scale structures. The flow configuration we have chosen is that of Wadcock (1987) at Reynolds number based on chord Re(sub c) = u(sub infinity)c/v = 1.64 x 10(exp 6), Mach number M = 0.2, and 12 deg angle of attack.

Jansen, Kenneth↗

Turboexpander for Direct Cooling in Hydrogen Vehicle Fueling Infrastructure

Hydrogen fuel cell electric vehicles (FCEVs) have been identified as one of a few options for zero carbon emissions transportation. A major advantage of FCEVs is that they can fuel quickly and follow a familiar fueling behavior to hydrocarbon-fueled vehicles. Whether light duty or heavy duty, the goal for a hydrogen dispenser is to fuel a vehicle in the same amount of time as the fossil fuel equivalent. When hydrogen is dispensed into the vehicle storage system, however, the temperature rises due to the Joule-Thomson effect and the heat of compression. Typically, vehicles store the compressed hydrogen in composite overwrapped pressure vessels that have a polymer liner with an operational temperature limit of 85°C. This temperature limit can be exceeded during fast fueling if hydrogen is not precooled. Precooling allows for a dispenser to fuel a vehicle at a faster flow rate by preventing the storage tank on the vehicle from overheating. Fueling protocols and requirements are presented in SAE J2601 Fueling Protocols for Light Duty Gaseous Hydrogen Surface Vehicles [1]. A heavy-duty equivalent is under development with similar requirements for precooling. Currently, conventional precooling for light-duty vehicle refueling uses a heat exchanger and chiller to cool the hydrogen gas to -40°C before entering the vehicle. The precooling system represents a significant part of the station capital and operating costs, so if the cost of the precooling system can be reduced by improving its efficiency, the overall station capital and operating cost can be reduced. In this project, National Renewable Energy Laboratory (NREL) and Sandia National Laboratories (SNL) researchers teamed up to investigate the turboexpander precooling application. A turboexpander is a device that places a turbine in a flow path where a pressure differential can be attained. This expansion device will extract work and lower the temperature of the fluid as the pressure reduces. While initial calculations based on established principles showed potential for a turboexpander to generate cooled gas, much work needs to be done to prove the concept. Turboexpanders typically work best under steady state conditions, while the dispenser is a very dynamic flow system. Dynamic turboexpander systems have been proven, such as a turbocharger on a gasoline vehicle. The inlet pressure at a dispenser is also much higher than any other known turboexpander system but should behave similarly to higher density fluids at lower pressures. Having both performed initial calculations, NREL and SNL researchers teamed up to investigate the turboexpander precooling application further. A project was soon built around the idea with SNL performing system modeling using previously proven capabilities and NREL performing hardware characterization with established station capabilities. Creare LLC was contracted as the turbomachinery expert to design and build the concept device. Part way through the project, however, contracting issues with the funding partner caused the project to terminate early before building and characterizing the concept device. While the project could not continue, many key findings were already learned. This paper is a summary of those findings.

08 HYDROGEN↗

Observations of airflow around a supertall curved building and its impact on temperature and humidity in Houston's urban center

Characterization of realistically shaped skyscrapers embedded in non-uniform neighbourhoods experiencing intricate weather patterns remains inadequately investigated. Aiming to close this gap, the Center for Multiscale Applied Sensing team deployed its mobile observatory in the street canyons around the curved Wells Fargo Plaza skyscraper in downtown Houston, TX. Three deployments allowed airflow observations under different inflow wind and thermodynamic stability conditions. Doppler lidar measurements reveal that when inflow hits the curved wall of the skyscraper, perpendicular canyons experience similar vortex configurations creating two windward and two leeward circulations. Windsond measurements support that buoyancy within the deep street canyons can generate thermal updrafts as strong as 2 m s -1 which is sufficient to overturn the mechanical downwash under gentle wind conditions. Canyons experiencing venting during the daytime were observed to be more thermodynamically stable at night while thermodynamically stable canyons during the day were observed to be more thermodynamically unstable at night owing to the accumulation of heat near street-level. Fourier decomposition of the vertical velocity measurements shows that in all cases flow exhibited high Reynolds numbers and was composed of turbulent eddies of predominantly 6 and 15 min periods. Here, this observational dataset provides insights to assess wind load, pedestrian comfort, urban air mobility, and natural ventilation and may be used as a benchmark for numerical model and wind tunnel studies attempting to represent realistically complex urban conditions.

54 ENVIRONMENTAL SCIENCES↗

Chain entanglements enable regeneration of high-performance thermosets

Thermoset plastics underpin structural materials, electronics and transportation, yet the permanent covalent networks that prevent flow and provide dimensional stability also make them difficult to recycle without sacrificing performance. In this work we show that high-performance thermosets can be built around dense chain entanglements, the physical interlacing of long polymer strands, rather than dense permanent crosslinks, with only a small number of selectively cleavable junctions preserving connectivity. Long, rigid, entangled polyolefin backbones generated by frontal polymerization form glassy polymers with high stiffness, high toughness and excellent creep suppression yet can be fully deconstructed into soluble, linear oligomers. Varying oligomer length and end-group chemistry enables their reuse as re-entangling building blocks that regenerate thermosets with thermal and mechanical properties that remain unchanged across generations. The strategy further extends to high-temperature fibre-reinforced composite matrices and additively manufactured structures, establishing chain entanglement as a design principle for durable, regenerable thermosets.

36 MATERIALS SCIENCE↗

University of Hawai‘i, Shallow Geothermal Resources: Energy Technology Innovation Partnership Project (Final Report)

Scientists at Lawrence Berkeley National Laboratory (Berkeley Lab) have teamed up with the University of Hawai‘i at Manoa (UH Manoa) through the U.S. Department of Energy’s Energy Technology Innovation Partnership Project to evaluate the technological and market feasibility of shallow geothermal heat exchanger (GHE) technology. UH requested this analysis to evaluate opportunities in building cooling, energy efficiency, and emissions reduction applications in Hawai‘i. UH has an abundance of geologic and geothermal data and is looking to the national labs’ expertise to execute this analysis. UH is also interested in investigating policy, regulatory, and business conditions advantageous for implementation of a pilot project and more broad deployment of this technology in Hawai‘i. In many locations around the world, the demands for heating and cooling are roughly balanced over the course of the year, so GHEs do not cause significant long-term changes in subsurface temperature. This is not the case in Hawai’i, where the demand for heating is very small, meaning that, over time, GHEs will add heat to the subsurface. If temperatures increase significantly, GHE systems will not work as designed. Regional groundwater flow has the potential to sweep heated water away from boreholes, thereby maintaining the functionality of the GHE system. Significant regional groundwater flow requires two things: a sufficiently large driving hydraulic head gradient (usually closely related to surface topography), and sufficient porosity and permeability to enable groundwater to flow in large enough quantities to enable near-borehole temperatures to be maintained at ambient values. Hawai‘i’s volcanic terrain offers ample surface topographic variation. The lava itself shows an extremely large range of porosity and permeability, so sites with large enough values of these properties must be selected. Numerical modeling of coupled groundwater and heat flow can be used to determine how large is large enough. Primarily, closed-loop systems have been investigated. Other options considered are open-loop systems and using cool seawater as the chilling source. Project work investigated the feasibility of GHE technology at two scales. At the island scale, GIS layers of various attributes relevant for GHE were combined to develop an overall favorability map for employing GHE in Hawai‘i. At the local scale, a hydrogeologic model for the subsurface component of a closed-loop system was developed for the Stan Sheriff Center at the UH Manoa campus. This site is considered promising because the rock below and immediately downgradient of the borefield is highly permeable, consisting of a subsurface karst system (limestone containing high-permeability open channels), which is underlain by a thick, high-permeability fractured basalt. Moreover, the site is near the base of the Ko‘olau Range, providing a large hydraulic head gradient. Thus, groundwater flow through the site is expected to be large, enabling efficient removal of heated groundwater. A full-GHE-system model of the site was also developed, with a simplified representation of the subsurface, in which groundwater flow is not considered and heat transfer is purely by conduction. Using the building cooling load data provided by UH, simulation results show that with groundwater flow present, a GHE can operate successfully for at least 10 years, but with no groundwater flow, the subsurface begins to heat up after only one year of operation, making the GHE unviable within 2-6 years. The team also developed a techno-economic model for this site to compare the cost of cooling using a GHE system with the costs of operating the current air-conditioning system. The GHE system is advantageous economically if favorable tax incentives and interest rates can be obtained.

15 GEOTHERMAL ENERGY↗

Vadose and Saturated Zone Flow and Transport Model Package Report for the Active Trenches of the Low-Level Burial Grounds, Hanford Site, Washington

This model package report (MPR) documents the development of the integrated vadose and saturated zone flow and transport model developed for the performance assessment of Trenches 31 and 34 in the low-level burial grounds (LLBGs). This modeling capability is intended for use in addressing the analysis requirements outlined in DOE O 435.1, Chg 1, Radioactive Waste Management1. The overall objective of the modeling effort is to provide a basis for making informed disposal decisions pertinent to Trenches 31 and 34. The purpose of the MPR is to document the development of the three-dimensional numerical vadose zone and saturated flow and transport model test case and evaluate its adequacy to support the LLBG performance assessment. The purpose is not to present results for DOE 435.1 decision making. The use of the model to perform base case and sensitivity analysis for the LLBG performance assessment, including inputs and results, is documented separately in subsequent environmental calculation files. This report discusses the development and translation of the conceptual model for flow and contaminant transport into the LLBG performance assessment three-dimensional numerical flow and transport model evaluated using the Subsurface Transport Over Multiple Phases (STOMP©) simulator. The development of representative geologic framework is described along with the implementation of waste release models used to represent contaminant release from waste disposed in the trenches. The report also provides the technical basis for specific model parameters and boundary conditions, along with description of modeling assumptions. This MPR includes certain calculations that are necessary to demonstrate the soundness of the model. Results provided by the model include vadose zone and saturated zone flow fields, and estimates of the possible future concentration in groundwater of technetium-99 and iodine-129 as example test cases. As an evaluation of the test cases, the model estimates of current vadose conditions are compared to available and analogous field and laboratory data, and compared to the results from the original performance assessment model (WHC-EP-0645, Performance Assessment for the Disposal of Low-Level Waste in the 200 West Area Burial Grounds 2 ). The features, events, and processes applicable to vadose zone and saturated zone flow and transport model are identified, and representative initial estimates for various parameters are documented. Note that the parameter estimates presented in this MPR are for illustration purposes, and may or may not reflect values selected for eventual performance assessment. Several key topical discussions (i.e., basis for recharge estimates, basis for vadose zone modeling, basis for saturated zone model development, and calibration) are included, which serve as the groundwork for confidence building for the groundwater pathway modeling and results. Numerical simulation results based on an example test case are included to illustrate the use of the combined saturated-unsaturated model in performance assessment calculations. Sensitivity and uncertainty results are not included in this MPR. Those results will be included in future environmental calculation files. The inclusion of the trapezoidal trench geometry and construction details in the finite difference grid introduces some gross simplifications regarding the trench and liner systems. The model test case presented in this MPR includes the assumption that the trench liner system does not affect flow through or around the trenches after the liner system is assumed to fail. This MPR also includes results of other test cases that involve alternate assumptions about how to incorporate the hydraulic effects of the trenches into the vadose zone of the model. These alternate cases do not attempt to account for the presence of the liner system after its assumed failure either. None of these cases is considered to be the base case at this time. Analysis and alternate cases that attempt to account for the presence of the liner system in greater detail, and its effect on flow through and around it, are to be documented in subsequent environmental calculation files. Depending on the results of those analyses and alternate cases, the eventual base case may involve more detailed inclusion of the effects of the liner system hydraulics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-speed, high-lift aerodynamic characteristics of slender, hypersonic accelerator-type configurations

Two investigations were conducted in the Langley 14 by 22 Foot Subsonic Tunnel to determine the low-speed aerodynamic characteristics of a generic hypersonic accelerator-type configuration. The model was a delta wing configuration incorporating a conical forebody, a simulated wrap-around engine package, and a truncated conical aftbody. Six-component force and moment data were obtained over a range of attack from -4 to 30 degrees and for a sideslip range of + or - 20 degrees. In addition to tests of the basic configuration, component build-up tests were conducted; and the effects of power, forebody nose geometry, canard surfaces, fuselage strakes, and engines on the lower surface alone were also determined. Control power available from deflections of wing flaps and aftbody flaps was also investigated and found to be significantly increased during power-on conditions. Large yawing moments resulted from asymmetric flow fields exhibited by the forebody as revealed by both surface pressure data and flow visualization. Increasing nose bluntness reduced the yawing-moment asymmetry, and the addition of a canard eliminated the yawing-moment asymmetry.

Gatlin, Gregory M.↗

Random Vibration Simulation and Testing of a Compact, Magnetic Bearing Supported Blower for Space Applications

NASA is developing a next-generation CO2 removal system, the Four Bed Carbon Dioxide Scrubber (4BCO2), which will use the International Space Station (ISS) as a testbed. A key component of both the existing and the new system is the blower that provides the airflow through the CO2 sorbent beds. To improve performance and reliability, magnetic bearings will be used in lieu of more conventional bearings (e.g. ball bearings or hydrodynamicbearings) to improve resistance to contaminants and enable extensibility with regards to blower speed, pressure rise and mass flow rate. The new blower features a high-efficiency permanent magnet motor, a five-axis, active magnetic bearing system, and a compact controller containing both a variable speed drive and magnetic bearing controller. The blower uses a centrifugal impeller to pull air from the inlet port and drive it through an annular space around the motor and magnetic bearing components to the exhaust port. Technical challenges of the blower and controller development include survival of the blower system under launch random vibration loads, operation in microgravity, packaging under strict size and weight requirements, and successful operation during 4BCO2 operational changeovers. Each serial build of the blower must pass a severe random vibration test to prove it will survive launch conditions. This paper discusses the vibration test requirements and provides details of a simulation performed to estimate the peak backup bearing displacements and loads. Results from the successful random vibration testing of the prototype build are discussed and compared to the simulation.

bearings↗

Use of CFD in the Design of the 10- by 10-Foot Supersonic Wind Tunnel Characterization Array

At the 10- by 10-Foot Supersonic Wind Tunnel at the NASA Glenn Research Center, a future full test section characterization generated an ideal opportunity to design and build new characterization hardware to improve the understanding of the flow field, including flow quality, uniformity, and uncertainty in primary variables of interest. An array of flow sensing probes, referred to as the Characterization Array, was designed and built to replace 1960’s-era test section characterization hardware. Many references exist to guide wind tunnel characterization practitioners in the design of new hardware to properly measure various aspects of the flow within their wind tunnel facilities. Although reliable sources of information, these references tend to be over 30 years old and are not exhaustive. In scenarios where design decisions needed to be validated, computational simulations of the flow field around the characterization hardware were used. Decisions regarding probe location, probe spacing, and performance of various probes were justified using computational fluid dynamic simulations and rules-of-thumb from the legacy resources available in literature. This paper is intended to serve as an example of the benefits from integrating CFD into the design of wind tunnel hardware, particularly hardware for wind tunnel characterization.

CFD↗