Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluctuation diagnostic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The National Spherical Torus Experiment-Upgrade poloidal high-k scattering system pitch angle design modifications

A 693 GHz, eight-channel, poloidal high-k (k refers to wavenumber) collective scattering system is under development for the National Spherical Torus Experiment-Upgrade device. It will replace the previous 280 GHz, five-channel, tangential scattering system to study high-k electron density fluctuations, thereby providing a measurement of the k θ -spectrum of both electron temperature gradient and ion temperature gradient modes. A tool is under development to calculate the wavenumber that exists in the presence of strong magnetic pitch angles. Here we use this tool to motivate a new receiver optical design for significantly improved performance, details of which are presented herein.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of wave mode content in fully turbulent, moderately collisional plasma laboratory experiment and kinetic simulation. Final Report

A final report of the activities of Bryn Mawr College for award DE-SC0018258. The major goal for the project is to make magnetic and Langmuir-probe-based density fluctuations measurements using identical diagnostic and acquisition setups on two different laboratory-based turbulent plasma devices: SSX at Swarthmore College and a new plasma source in development at Bryn Mawr College (BMX). We propose to generate single-point correlation and k-filtering metrics using these experimental measurements. These metrics will be compared directly to kinetic simulations of the experimental environments in order to determine wave mode content of the laboratory turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Collaborative Research: Analysis of wave mode content in fully turbulent, moderately collisional plasma laboratory experiment and kinetic simulation

Our major goal for the project is to make magnetic and Langmuir-probe-based density fluctuations measurements using identical diagnostic and acquisition setups on two different laboratory-based turbulent plasma devices: SSX at Swarthmore College and a new plasma source in development at Bryn Mawr College (BMX). We propose to generate single-point correlation and k-filtering metrics using these experimental measurements. These metrics will be compared directly to kinetic simulations of the experimental environments in order to determine wave mode content of the laboratory turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of wave mode content in fully turbulent, moderately collisional plasma laboratory experiment and kinetic simulation

Our major goal for the project was to make magnetic field and plasma density fluctuation measurements using identical diagnostic and acquisition setups on two different laboratory-based turbulent plasma devices: SSX at Swarthmore College and a new plasma source in development at Bryn Mawr College (BMX). We used single-point correlation and k-filtering metrics using these experimental measurements. These metrics were compared to kinetic simulations of the experimental environments in order to determine wave mode content of the laboratory turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Isotope effects on energy transport in the core of ASDEX-Upgrade tokamak plasmas: Turbulence measurements and model validation

Design and operation of future tokamak fusion reactors using a deuterium–tritium 50:50 mix requires a solid understanding of how energy confinement properties change with ion mass. This study looks at how turbulence and energy transport change in L-mode plasmas in the ASDEX Upgrade tokamak when changing ion species between hydrogen and deuterium. For this purpose, both experimental turbulence measurements and modeling are employed. Local measurements of ion-scale (with wavevector of fluctuations perpendicular to the B-field k⊥< 2 cm−1, k⊥ρs< 0.2, where ρs is the ion sound Larmor radius using the deuterium ion mass) electron temperature fluctuations have been performed in the outer core (normalized toroidal flux ρTor=0.65−0.8) using a multi-channel correlation electron cyclotron emission diagnostic. Lower root mean square perpendicular fluctuation amplitudes and radial correlation lengths have been measured in hydrogen vs deuterium. Measurements of the cross-phase angle between a normal-incidence reflectometer and an ECE signal were made to infer the cross-phase angle between density and temperature fluctuations. The magnitude of the cross-phase angle was found larger (more out-of-phase) in hydrogen than in deuterium. TRANSP power balance simulations show a larger ion heat flux in hydrogen where the electron-ion heat exchange term is found to play an important role. These experimental observations were used as the basis of a validation study of both quasilinear gyrofluid trapped gyro-Landau fluid-SAT2 and nonlinear gyrokinetic GENE codes. Linear solvers indicate that, at long wavelengths (k⊥ρs<1), energy transport in the deuterium discharge is dominated by a mixed ion-temperature-gradient (ITG) and trapped-electron mode turbulence while in hydrogen transport is exclusively and more strongly driven by ITG turbulence. The Ricci validation metric has been used to quantify the agreement between experiments and simulations taking into account both experimental and simulation uncertainties as well as four different observables across different levels of the primacy hierarchy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The role of cool-flame fluctuations in high-pressure spray flames, studied using high-speed optical diagnostics and Large-Eddy Simulations

Here this work investigates the low- and high-temperature ignition and combustion processes, applied to the Engine Combustion Network Spray A flame, combining advanced optical diagnostics and large-eddy simulations (LES). Simultaneous high-speed (50 kHz) formaldehyde (CH 2 0) planar laser-induced fluorescence (PLIF) and line-of-sight OH* chemiluminescence imaging were used to measure the low- and high-temperature flame, during ignition as well as during quasi-steady combustion. While tracking the cool flame at the laser sheet plane, the present experimental setup allows detection of distinct ignition spots and dynamic fluctuations of the lift-off length over time, which overcomes limitations for flame tracking when using schlieren imaging. After significant development to improve LES prediction of the low-and high-temperature flame position, both during the ignition processes and quasi-steady combustion, the simulations were analyzed to gain understanding of the mixture variance and how this variance affects formation/consumption of CH 2 0. Analysis of the high-temperature ignition period shows that a key improvement in the LES is the ability to predict heterogeneous ignition sites, not only in the head of the jet, but in shear layers at the jet edge close to the position where flame lift-off eventually stabilizes. The LES analysis also shows concentrated pockets of CH 2 0, in the center of jet and at 20 mm downstream of the injector (in regions where the equivalence ratio is greater than 6), that are of similar length scale and frequency as the experiment (approximately 5–6 kHz). The periodic oscillation of CH 2 0 match the frequency of pressure waves generated during auto-ignition and reflected within the constant-volume vessel throughout injection. The ability of LES to capture the periodic appearance and destruction of CH 2 0 is particularly important because these structures travel downstream and become rich premixed flames that affect soot production.

42 ENGINEERING↗

Density determination from far-infrared lines

We demonstrate that when there are gas density variations within a nebula, various line ratios used to determine electron density (Ne) can give different results. When there are non-constant density conditions, it is shown that by using one (average) Ne, significant, systematic biases may occur in the derived chemical abundance ratios. The abundance ratio of a heavy element (when a collisionally excited line is used) to ionized hydrogen may be subject to a large underestimate in the presence of density fluctuations. The more Ne-diagnostic observations made, the more reliable will be the deciphering of the actual Ne variation throughout a nebula.

Rubin, Robert H.↗

A combined Phase Contrast Imaging and heterodyne interferometer for multiscale fluctuation measurements in tokamak plasmas

An upgrade to the Phase Contrast Imaging (PCI) diagnostic on the DIII-D tokamak has successfully combined PCI with density interferometry to provide electron density fluctuation measurements across an unprecedented range in wavenumber. The combined diagnostic uses a single laser and a single beam path through the tokamak, minimizing machine resources in anticipation of future reactor-scale devices where port access will be at a premium. The PCI multichannel detector provides low-noise, wavenumber-resolved detection of moderate-wavenumber turbulence, while the interferometer channel is sensitive to long-wavelength turbulence, including the peak of ion-scale turbulence and MHD. The overlap in wavenumber range between the two schemes allows for an in situ absolute calibration of the PCI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Upgrade of DIII-D radial interferometer–polarimeter for large bandwidth, low noise, and toroidal mode number measurements

Near ion-cyclotron frequency (f ci ) fluctuations, such as those originating from Global and Compressional Alfvén Eigenmodes (GAEs/CAEs), are expected to be present in future fusion reactors but are not well understood due to the limited availability of core measurements in present-day tokamaks. The measurement bandwidth of the Radial Interferometer–Polarimeter (RIP) diagnostic has been upgraded from 1 to 5 MHz to detect these fluctuations in DIII-D. RIP adopts the three-wave technique for simultaneous polarimetric and interferometric measurements. Solid-state microwave sources operating at 650 GHz are used as probe beams and provide 5 MHz bandwidth for both polarimetric and interferometric measurements. Bandwidths of related hardware, including mixer amplifier, signal cable, and digital phase demodulator, are increased correspondingly. Measurement noise is minimized by reducing the time delay between reference and probe signals to nanosecond level and employing correlation-based techniques. Using the upgraded diagnostic, CAE/GAE-like bursting fluctuations are observed in neutral-beam heated plasmas with toroidal magnetic field B φ ≈ 1 T. Current upgrades being undertaken would enable the evaluation of toroidal mode number for these modes. Furthermore, this work opens the possibility of better understanding near ion-cyclotron frequency fluctuations in fusion relevant plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gyrokinetic simulations compared with magnetic fluctuations diagnosed with a Faraday-effect radial interferometer-polarimeter in the DIII-D pedestal

Abstract Experimental data on electromagnetic fluctuations in DIII-D, made available by the Faraday-effect radial interferometer-polarimeter (RIP) diagnostic Chen (2016 Rev. Sci. Instrum. 87 11E108), is examined in comparison with detailed gyrokinetic simulations using gyrokinetic electromagnetic numerical experiment (GENE). The diagnostic has the unique capability of making internal measurements of fluctuating magnetic fields ∫ n e δ B r d R ∫ n e d R . Local linear simulations identify microtearing modes (MTMs) over a substantial range of toroidal mode numbers (peaking at n = 15) with frequencies in good agreement with the experimental data. Local nonlinear simulations reinforce this result by producing a magnetic frequency spectrum in good agreement with that diagnosed by RIP. Simulated heat fluxes are in the range of experimental expectations. However, magnetic fluctuation amplitudes are substantially lower than the experimental expectations. Possible sources of this discrepancy are discussed, notably the fact that the diagnostics are localized at the mid-plane—the poloidal location where the simulations predict the fluctuation amplitudes to be smallest. Despite some discrepancies, several connections between simulations and experiments, combined with general criteria discriminating between potential pedestal instabilities, strongly point to MTMs as the source of the observed magnetic fluctuations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fan Noise Source Diagnostic Test: Vane Unsteady Pressure Results

To investigate the nature of fan outlet guide vane pressure fluctuations and their link to rotor-stator interaction noise, time histories of vane fluctuating pressures were digitally acquired as part of the Fan Noise Source Diagnostic Test. Vane unsteady pressures were measured at seven fan tip speeds for both a radial and a swept vane configuration. Using time-domain averaging and spectral analysis, the blade passing frequency (BPF) harmonic and broadband contents of the vane pressures were individually analyzed. Significant Sound Pressure Level (SPL) reductions were observed for the swept vane relative to the radial vane for the BPF harmonics of vane pressure, but vane broadband reductions due to sweep turned out to be much smaller especially on an average basis. Cross-correlation analysis was used to establish the level of spatial coherence of broadband pressures between different locations on the vane and integral length scales of pressure fluctuations were estimated from these correlations. Two main results of this work are: (1) the average broadband level on the vane (in dB) increases linearly with the fan tip speed for both the radial and swept vanes, and (2) the broadband pressure distribution on the vane is nearly homogeneous and its integral length scale is a monotonically decreasing function of fan tip speed.

Envia, Edmane↗

Optical Spectrum of the Compact Planetary Nebula IC 5117

High resolution spectroscopic data of the very compact planetary nebula IC 5117 are obtained in the optical wavelengths, 3700A - 10050A, with the Hamilton Echelle Spectrograph at Lick Observatory, and which have been analyzed along with the International Ultraviolet Explorer (IUE) UV archive data. Although a diagnostic diagram shows significant density and temperature fluctuations, our analysis indicates that the nebular gas may be represented by a homogeneous shell of extremely high density gas, N(sub epsilon) approx. 90 000 /cu cm. The average electron temperatures, e.g. indicated by the [OIII] diagnostics, are around 12 000 K. We construct a photoionization model to represent most of the observed line intensities, and the physical condition of this compact nebulosity. Based on the semi-empirical ionization correction approach, and model indications, we derived the elemental abundances: He, C, N, O, Ne, and Ar appear to be normal or marginally depleted compared to the average planetary nebula, while the remaining elements, S, Cl, and K appear to be enhanced. IC 5117 is perhaps a very young compact planetary nebula, slightly more evolved than the other well-known compact planetary nebula IC 4997. The central stellar temperature is likely to be around 120 000 K, evolved from a C-rich AGB progenitor.

Hyung, Siek↗

Edge fluctuation measurements in EDA H-mode and QCE plasmas in ASDEX Upgrade using the correlation electron cyclotron emission diagnostic

The requirement of a plasma solution without large edge-localized modes (ELMs) for future fusion devices motivates the study of plasmas without Type I ELMs. The enhanced D–α (EDA) and quasi-continuous exhaust (QCE) scenarios are two such Type I ELM free plasmas, but their underlying physics principles are not fully understood. A database of EDA and QCE plasmas from ASDEX Upgrade was compiled and analyzed using the correlation electron cyclotron emission diagnostic in order to study differences between properties of the quasi-coherent mode (QCM) between these two regimes. Investigations into measured spectral properties of the QCM, radiated temperature fluctuations δT rad /T rad , and radial correlation lengths L c showed no differences between the two regimes. Spectral properties using the cross-power spectral density, G xy were similar between regimes, with the values measured to be a central frequency, $f$ $QCM$ ≈ 20 - 50 kHz; spectral width, Δ $f$ ≈ 5 - 40 kHz; δT rad /T rad ≈ 4-6%; and L c ≈ 1-2 cm. Investigations into a quantity representing the relative bandwidth Δ$f$/$f$ $QCM$ revealed differences between EDA and QCE plasmas when plotted radially, suggesting some type of interaction between the QCM in QCE plasmas with the surrounding broadband turbulence that is not present in EDA phases. Additionally, investigations into various drive terms for hypothesized instability drivers for the QCM are performed showing no difference in the parameter spaces of collisionality and the ion temperature, electron temperature, or electron pressure scale lengths between each regime indicating that there is no observable difference between the drive behind the QCM in each regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion temperature and rotation fluctuation measurements with ultra-fast charge exchange recombination spectroscopy (UF-CHERS) in the DIII-D tokamak

An upgraded detector and several optimizations have significantly improved the Ultra-Fast Charge Exchange Recombination Spectroscopy (UF-CHERS) diagnostic sensitivity to ion temperature and parallel velocity fluctuations at turbulence relevant spatio-temporal scales. Normalized broadband ion temperature and parallel velocity fluctuations down to x̃x∼1% (x = Ti, v∥) and up to ∼450 kHz have been measured in a variety of plasmas. The multi-field nature of the CHERS technique also allows measurements of the cross-phase angles of the fluctuating fields. UF-CHERS is optimized to observe emissions from the electron exchange reaction between intrinsic C6+ and hydrogenic neutral beam injected particles near 529 nm. UF-CHERS consists of two chords separated by ∼1 cm radially, less than the turbulence correlation length in DIII-D plasmas, which enables correlated measurements to suppress incoherent electronic and photon noise. The optical components of the spectrometer include a volume-phase-holographic grating with >90% transmission between 528 and 530 nm and f/2 200-mm lenses, selected to maximize the optical efficiency and photon flux. Diffracted light from each chord is collected in eight spectral bins, each with a bandwidth of ∼0.25 nm, and detected and amplified by chilled avalanche photodiodes and custom high-gain, wide bandwidth low-noise preamplifiers to achieve the optimal signal-to-noise ratio. The resulting signals are digitized at 1 MHz, 103–104× faster than the conventional CHERS diagnostics. Spatial coverage is achieved by repositioning a motorized fiber tray between plasmas. UF-CHERS measurements will advance the understanding of turbulent ion transport and contribute to the validation of transport models and simulations.

Truong, D. D. (ORCID:0000000285732539)↗

The effect of plasma shaping on high density H-mode SOL profiles and fluctuations in TCV

Abstract The impact of plasma shaping on the properties of high density H-mode scrape-off layer (SOL) profiles and transport at the outer midplane has been investigated on Tokamakà configuration variable. The experimental dataset has been acquired by evolving the upper triangularity while keeping the other parameters constant. The scan comprises δ u p values between 0.0 and 0.6, excluding negative triangularity scenarios. Within this study, a transition from type-I edge localised modes to the quasi-continuous exhaust regime takes place from low to high δ u p . The modification of the upstream SOL profiles has been assessed, in terms of separatrix quantities, within the α t turbulence control parameter theoretical framework (Eich et al 2020 Nucl. Fusion 60 056016). The target parallel heat load and the upstream near-SOL density profiles have been shown to broaden significantly for increasing α t . Correspondingly, in the far SOL a density shoulder formation is observed when moving from low to high δ u p . These behaviours have been correlated with an enhancement of the SOL fluctuation level, as registered by wall-mounted Langmuir probes as well as the thermal helium beam diagnostic. Specifically, both the background and the filamentary-induced fluctuating parts of the first wall ion saturation current signal are larger at higher δ u p , with filaments being ejected more frequently into the SOL. Comparison of two pulses at the extremes of the δ u p scan range, but with otherwise same input parameters, shows that the midplane neutral pressure does not change much during the H-mode phase of the discharge. This indicates that indirect effects of the change in geometry, linked to first wall recycling sources, should not play a significant role. The total core radiation increases at high δ u p , on account of a stronger plasma–wall interaction and resulting larger carbon impurity intake from the first wall. This is likely associated to the enhanced first wall fluctuations, as well as a smaller outer gap and the close-to-double-null magnetic topology at high shaping.

Stagni, A. (ORCID:0000000180841544)↗

Pedestal fluctuation measurements with charge exchange imaging at the DIII-D tokamak

A new high radial resolution 2D multichannel Charge eXchange Imaging (CXI) diagnostic is under development for deployment at DIII-D. Here, the diagnostic system will measure low-to-intermediate radial wavenumber carbon density fluctuations by observing the n = 8 – 7 (λ = 529.06 nm) C-VI emission line, resulting from charge exchange collisions between heating neutral beam atoms and the intrinsic carbon ion density. The new CXI diagnostic will provide measurements with ΔR ~ 0.4 cm to access higher k r instabilities (k r < 8 cm –1 ) predicted to arise in the steep-gradient region of the H-mode pedestal. The CXI system will feature 60 fiber bundles in a 12 × 5 arrangement, with each bundle consisting of four 1 mm fibers. A custom optical system has been designed to filter and image incoming signals onto an 8 × 8 avalanche photodiode array. Additionally, a novel electronics suite has been designed and commissioned to amplify and digitize the relatively low-intensity carbon signal at a 2 MHz bandwidth. Forward modeling results of the active C-VI emission suggest sufficient signal to noise ratios to resolve turbulent fluctuations. Prototype measurements demonstrate the ability to perform high frequency pedestal measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗