Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluctuation diagnostic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Upgrade of DIII-D radial interferometer–polarimeter for large bandwidth, low noise, and toroidal mode number measurements

Near ion-cyclotron frequency (f ci ) fluctuations, such as those originating from Global and Compressional Alfvén Eigenmodes (GAEs/CAEs), are expected to be present in future fusion reactors but are not well understood due to the limited availability of core measurements in present-day tokamaks. The measurement bandwidth of the Radial Interferometer–Polarimeter (RIP) diagnostic has been upgraded from 1 to 5 MHz to detect these fluctuations in DIII-D. RIP adopts the three-wave technique for simultaneous polarimetric and interferometric measurements. Solid-state microwave sources operating at 650 GHz are used as probe beams and provide 5 MHz bandwidth for both polarimetric and interferometric measurements. Bandwidths of related hardware, including mixer amplifier, signal cable, and digital phase demodulator, are increased correspondingly. Measurement noise is minimized by reducing the time delay between reference and probe signals to nanosecond level and employing correlation-based techniques. Using the upgraded diagnostic, CAE/GAE-like bursting fluctuations are observed in neutral-beam heated plasmas with toroidal magnetic field B φ ≈ 1 T. Current upgrades being undertaken would enable the evaluation of toroidal mode number for these modes. Furthermore, this work opens the possibility of better understanding near ion-cyclotron frequency fluctuations in fusion relevant plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gyrokinetic simulations compared with magnetic fluctuations diagnosed with a Faraday-effect radial interferometer-polarimeter in the DIII-D pedestal

Abstract Experimental data on electromagnetic fluctuations in DIII-D, made available by the Faraday-effect radial interferometer-polarimeter (RIP) diagnostic Chen (2016 Rev. Sci. Instrum. 87 11E108), is examined in comparison with detailed gyrokinetic simulations using gyrokinetic electromagnetic numerical experiment (GENE). The diagnostic has the unique capability of making internal measurements of fluctuating magnetic fields ∫ n e δ B r d R ∫ n e d R . Local linear simulations identify microtearing modes (MTMs) over a substantial range of toroidal mode numbers (peaking at n = 15) with frequencies in good agreement with the experimental data. Local nonlinear simulations reinforce this result by producing a magnetic frequency spectrum in good agreement with that diagnosed by RIP. Simulated heat fluxes are in the range of experimental expectations. However, magnetic fluctuation amplitudes are substantially lower than the experimental expectations. Possible sources of this discrepancy are discussed, notably the fact that the diagnostics are localized at the mid-plane—the poloidal location where the simulations predict the fluctuation amplitudes to be smallest. Despite some discrepancies, several connections between simulations and experiments, combined with general criteria discriminating between potential pedestal instabilities, strongly point to MTMs as the source of the observed magnetic fluctuations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Edge fluctuation measurements in EDA H-mode and QCE plasmas in ASDEX Upgrade using the correlation electron cyclotron emission diagnostic

The requirement of a plasma solution without large edge-localized modes (ELMs) for future fusion devices motivates the study of plasmas without Type I ELMs. The enhanced D–α (EDA) and quasi-continuous exhaust (QCE) scenarios are two such Type I ELM free plasmas, but their underlying physics principles are not fully understood. A database of EDA and QCE plasmas from ASDEX Upgrade was compiled and analyzed using the correlation electron cyclotron emission diagnostic in order to study differences between properties of the quasi-coherent mode (QCM) between these two regimes. Investigations into measured spectral properties of the QCM, radiated temperature fluctuations δT rad /T rad , and radial correlation lengths L c showed no differences between the two regimes. Spectral properties using the cross-power spectral density, G xy were similar between regimes, with the values measured to be a central frequency, $f$ $QCM$ ≈ 20 - 50 kHz; spectral width, Δ $f$ ≈ 5 - 40 kHz; δT rad /T rad ≈ 4-6%; and L c ≈ 1-2 cm. Investigations into a quantity representing the relative bandwidth Δ$f$/$f$ $QCM$ revealed differences between EDA and QCE plasmas when plotted radially, suggesting some type of interaction between the QCM in QCE plasmas with the surrounding broadband turbulence that is not present in EDA phases. Additionally, investigations into various drive terms for hypothesized instability drivers for the QCM are performed showing no difference in the parameter spaces of collisionality and the ion temperature, electron temperature, or electron pressure scale lengths between each regime indicating that there is no observable difference between the drive behind the QCM in each regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion temperature and rotation fluctuation measurements with ultra-fast charge exchange recombination spectroscopy (UF-CHERS) in the DIII-D tokamak

An upgraded detector and several optimizations have significantly improved the Ultra-Fast Charge Exchange Recombination Spectroscopy (UF-CHERS) diagnostic sensitivity to ion temperature and parallel velocity fluctuations at turbulence relevant spatio-temporal scales. Normalized broadband ion temperature and parallel velocity fluctuations down to x̃x∼1% (x = Ti, v∥) and up to ∼450 kHz have been measured in a variety of plasmas. The multi-field nature of the CHERS technique also allows measurements of the cross-phase angles of the fluctuating fields. UF-CHERS is optimized to observe emissions from the electron exchange reaction between intrinsic C6+ and hydrogenic neutral beam injected particles near 529 nm. UF-CHERS consists of two chords separated by ∼1 cm radially, less than the turbulence correlation length in DIII-D plasmas, which enables correlated measurements to suppress incoherent electronic and photon noise. The optical components of the spectrometer include a volume-phase-holographic grating with >90% transmission between 528 and 530 nm and f/2 200-mm lenses, selected to maximize the optical efficiency and photon flux. Diffracted light from each chord is collected in eight spectral bins, each with a bandwidth of ∼0.25 nm, and detected and amplified by chilled avalanche photodiodes and custom high-gain, wide bandwidth low-noise preamplifiers to achieve the optimal signal-to-noise ratio. The resulting signals are digitized at 1 MHz, 103–104× faster than the conventional CHERS diagnostics. Spatial coverage is achieved by repositioning a motorized fiber tray between plasmas. UF-CHERS measurements will advance the understanding of turbulent ion transport and contribute to the validation of transport models and simulations.

Truong, D. D. (ORCID:0000000285732539)↗

The effect of plasma shaping on high density H-mode SOL profiles and fluctuations in TCV

Abstract The impact of plasma shaping on the properties of high density H-mode scrape-off layer (SOL) profiles and transport at the outer midplane has been investigated on Tokamakà configuration variable. The experimental dataset has been acquired by evolving the upper triangularity while keeping the other parameters constant. The scan comprises δ u p values between 0.0 and 0.6, excluding negative triangularity scenarios. Within this study, a transition from type-I edge localised modes to the quasi-continuous exhaust regime takes place from low to high δ u p . The modification of the upstream SOL profiles has been assessed, in terms of separatrix quantities, within the α t turbulence control parameter theoretical framework (Eich et al 2020 Nucl. Fusion 60 056016). The target parallel heat load and the upstream near-SOL density profiles have been shown to broaden significantly for increasing α t . Correspondingly, in the far SOL a density shoulder formation is observed when moving from low to high δ u p . These behaviours have been correlated with an enhancement of the SOL fluctuation level, as registered by wall-mounted Langmuir probes as well as the thermal helium beam diagnostic. Specifically, both the background and the filamentary-induced fluctuating parts of the first wall ion saturation current signal are larger at higher δ u p , with filaments being ejected more frequently into the SOL. Comparison of two pulses at the extremes of the δ u p scan range, but with otherwise same input parameters, shows that the midplane neutral pressure does not change much during the H-mode phase of the discharge. This indicates that indirect effects of the change in geometry, linked to first wall recycling sources, should not play a significant role. The total core radiation increases at high δ u p , on account of a stronger plasma–wall interaction and resulting larger carbon impurity intake from the first wall. This is likely associated to the enhanced first wall fluctuations, as well as a smaller outer gap and the close-to-double-null magnetic topology at high shaping.

Stagni, A. (ORCID:0000000180841544)↗

Pedestal fluctuation measurements with charge exchange imaging at the DIII-D tokamak

A new high radial resolution 2D multichannel Charge eXchange Imaging (CXI) diagnostic is under development for deployment at DIII-D. Here, the diagnostic system will measure low-to-intermediate radial wavenumber carbon density fluctuations by observing the n = 8 – 7 (λ = 529.06 nm) C-VI emission line, resulting from charge exchange collisions between heating neutral beam atoms and the intrinsic carbon ion density. The new CXI diagnostic will provide measurements with ΔR ~ 0.4 cm to access higher k r instabilities (k r < 8 cm –1 ) predicted to arise in the steep-gradient region of the H-mode pedestal. The CXI system will feature 60 fiber bundles in a 12 × 5 arrangement, with each bundle consisting of four 1 mm fibers. A custom optical system has been designed to filter and image incoming signals onto an 8 × 8 avalanche photodiode array. Additionally, a novel electronics suite has been designed and commissioned to amplify and digitize the relatively low-intensity carbon signal at a 2 MHz bandwidth. Forward modeling results of the active C-VI emission suggest sufficient signal to noise ratios to resolve turbulent fluctuations. Prototype measurements demonstrate the ability to perform high frequency pedestal measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reduced fast-ion transport calculations of m = n = 1 fishbone-like instabilities in MAST-U

Fast-ion transport associated with an m = n = 1 fishbone-like burst in MAST-U discharge 47128 is investigated using a reduced guiding-center-based transport model (ORBIT-Kick) constrained by multi-diagnostic measurements. The two-dimensional beam-emission spectroscopy system provides measurements of the core poloidal mode structure and fluctuation amplitude, while EFIT++ reconstructions constrained by the motional Stark effect diagnostic indicate a flat q-profile with q 0 > 1⁠, indicating the absence of a resonant q = 1 surface and supporting a pressure-driven infernal-mode interpretation. Analytic m = n = 1 displacement profiles consistent with the measured core mode structure and equilibrium constraints are used as the mode structure inputs to ORBIT-Kick. The calculations show that the dominant resonances occur between the mode and co-passing fast ions, producing redistribution localized near the magnetic axis. Synthetic neutron camera signals from TRANSP-Kick recover up to 90% of the experimentally observed neutron deficit at the time of peak mode amplitude, indicating that the measured m = n = 1 mode is a dominant contributor to core fast-ion transport. However, the synthetic neutron signals recover rapidly, whereas the measured neutron emission continues to decrease after the peak amplitude. In conclusion, the remaining discrepancy may arise from contributions not included in the present single-harmonic model, including higher-m and higher-n harmonics, multi-harmonic interactions, and additional transport mechanisms, motivating future diagnostic development and modeling efforts to resolve and incorporate these additional contributions.

Wong, Henry H. [University of California, Los Ange↗

Development and preliminary results of 270 GHz microwave forward scattering diagnostic system on the experimental advanced superconducting tokamak (EAST)

To measure localized (intermediate, high) poloidal wavenumber electron density fluctuations, a tangential millimeter-wave collective scattering system has been designed and successfully developed on the experimental advanced superconducting tokamak (EAST). This innovative system employs a 270 GHz mm-wave probe beam, emitted from the mid-plane of Port K and directed towards Port P after passing through a combination of two in-vessel mirrors. Here these two ports are located on the EAST device’s midplane and are 110° apart. The downward scattered signals pass through two in-vessel mirrors, and exit through the P window. The received multi-channel separated scattering signals are arranged along the poloidal direction. This optical arrangement makes the monitored turbulent wave number is poloidal dominant and up to 40 cm −1 . The tangential microwave scattering scheme enables this diagnostic to monitor local density fluctuations, with typically a radial spatial resolution △ R = 5 cm, and a wavenumber resolution of △ k = 0.4 cm −1 . The scattering system underwent comprehensive laboratory testing in 2023, with installation finalized in 2024. The system features steerable launch and receiver optics, allowing remote control to position the scattering volume from normalized radius ρ –0 to the pedestal region on a shot-by-shot basis. Effective experimental data, characterized by distinct off-center spectral peaks, have been successfully obtained in neutral beam-heated plasmas on EAST. The beam tracing forward modeling has been employed for experimental data interpretation. The advanced millimeter-wave scattering system provides fluctuation measurement capability from ion temperature gradient to electron temperature gradient scale on low field side. Preliminary experimental density fluctuation data have been successfully obtained in neutral beam-heated plasmas on EAST. The localized measurement will be used for kinetic turbulence transport numerical simulation validation.

high-k collective scattering↗

Millimeter-wave high-wavenumber scattering diagnostic developments on EAST and NSTX-U

A pioneering 4-channel, high-k poloidal, millimeter-wave collective scattering system has been successfully developed for the Experimental Advanced Superconducting Tokamak (EAST). Engineered to explore high-k electron density fluctuations, this innovative system deploys a 270 GHz mm-wave probe beam launched from Port K and directed toward Port P (both ports lie on the midplane and are 110° part), where large aperture optics capture radiation across four simultaneous scattering angles. Tailored to measure density fluctuations with a poloidal wavenumber of up to 20 cm -1 , this high-k scattering system underwent rigorous laboratory testing in 2023, and the installation is currently being carried out on EAST. Its primary purpose lies in scrutinizing ion and electron-scale instabilities, such as the electron temperature gradient (ETG) mode, by furnishing measurements of the k θ (poloidal wavenumber) spectrum. This advancement significantly bolsters the capacity to probe high-k electron density fluctuations within the framework of EAST. Finally, beam tracing and data interpretation modules developed for both EAST and NSTX-U high-k scattering diagnostics are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation and characterisation of trapped electron modes in Wendelstein 7-X

In the past, quasi coherent (QC) modes were reported for nearly all tokamaks. The general definition describes modes as QC when the magnitude squared coherence is in the range of 0.3 to 0.6. QC modes are observed in the plasma core as well as in the plasma edge and can have quite different physical origins. The one in the core are observed in plasmas with low collisionality, where the electron temperature exceeds the ion temperature in the plasma core. This is the case for electron cyclotron heating in general. The origin of these modes are electrons trapped within a magnetic mirror, as reported in the past from various fusion devices. The so-called trapped-electron modes (TEMs) belong to drift wave instabilities and can be destabilized by electron-temperature gradients in the plasma core. From the diagnostic point of view, QC modes appear as fluctuations in electron density and temperature. Therefore, the microwave reflectometer is very well suited to monitor these modes. This paper describes experiments, conducted at the Wendelstein 7-X stellarator (W7-X), which aim at detecting QC modes at low wave numbers. A poloidal correlation reflectometer installed at W7-X, is able to measure low wave numbers ($k_\perp\unicode{x2A7D}{3.5}\,\textrm{cm}^{-1}$). For medium line-averaged densities ($\int n_\textrm{e}\unicode{x2A7D}{6 \times10^{19}}\,\textrm{m}^{-2}$) the plasma core is accessible for this diagnostic. For different magnetic configurations and plasma parameters, broad QC structures are observed in the coherence spectra. From the analysis of the rotation and the poloidal structure, these QC modes show the properties of electron-temperature-gradient driven TEMs. A linear relation between the mode velocity and the rotation frequency is found. The relation is uniform and confirms the nature of QC-mode observation as TEM in tokamaks, too.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design considerations for an ultrahigh-bandwidth Phase Contrast Imaging system applied to fusion grade devices

Abstract The PCI diagnostic is an internal reference interferometer that creates an image of absolutely calibrated electron density fluctuations integrated along the line of sight of the probing light beam. While conventional PCI diagnostics installed on fusion experiments worldwide employ light of wavelength equal to 10.59 μm, the same system using light at 1.55 μm wavelength would extend the spectral response in wave-number and frequency by factors of seven and over one hundred, respectively, thereby potentially providing quantitative measurements of the internal structure of density perturbations induced by either turbulent or radio-frequency waves, simultaneously covering ion to electron gyro-radius scales up to the GHz frequency region. Based on a previously developed 1.55 μm PCI prototype system, constraints to the design for such a diagnostic in fusion grade devices are presented and compared to those faced with the conventional method.

Instruments & Instrumentation↗

Edge radiated temperature fluctuations across confinement regime transitions in favorable and unfavorable drift configurations at ASDEX Upgrade

Abstract The physics behind the difference in heating power threshold for the low to high confinement (L–H) transition between favorable ion B × ∇ B drift (toward active X -point) and unfavorable ion B × ∇ B drift (away from active X -point) magnetic configurations is a longstanding open question. In this work we show differences in edge ( ρ p o l = 0.95 –1.0) turbulence in matched heating power favorable and unfavorable magnetic configuration discharges using a correlation electron cyclotron emission diagnostic to measure radiated temperature ( T r a d ) fluctuations. During power matched L-mode phases, the edge T r a d fluctuations have higher amplitude in the unfavorable configuration plasma as compared to the favorable configuration plasma. The lower fluctuation amplitude in favorable configuration is observed concomitant with increased E × B shear, as compared to the unfavorable case. Although this turbulence is different in amplitude, it is similar in radial and frequency structure between favorable and unfavorable configurations and grows to the weakly coherent mode during the I-mode phase of the unfavorable configuration discharge. A broadband pedestal fluctuation is seen during an inter-ELM H-mode period of the favorable configuration discharge.

Physics↗

Implementation of heterodyne detection of radio frequency waves using phase contrast imaging

An upgrade to the DIII–D phase contrast imaging (PCI) diagnostic for detection of radio frequency waves has been implemented using low-noise optical heterodyning. Electro-optical modulation allows detection of waves with frequencies up to 500 MHz with wide flexibility restricted only by the driver electronics, with continuous adjustability up to 100 MHz and fixed frequency drivers needed for higher frequencies. The PCI diagnostic images the line-integrated plasma density fluctuations and provides absolutely calibrated measurements with good wavenumber resolution.

Rost, J. C. [Massachusetts Institute of Technology↗

Status of the development and testing of in-vessel and ECH-protection components for the ITER low-field side reflectometer

The ITER Low-Field Side Reflectometer (LFSR) is a critical diagnostic system designed to measure edge electron density profiles, fluctuations, and plasma rotation in ITER. This paper presents the latest developments in the design, testing, and validation of key in-vessel and Electron Cyclotron Heating (ECH) protection components. The LFSR antenna array has been optimized to provide robust coverage over expected plasma vertical displacements and a Doppler measurement for plasma rotation. Further, a comprehensive assessment of a 170-GHz diffraction grating and a novel stray-ECH power monitor demonstrates effectiveness in mitigating the impact of stray ECH power on sensitive microwave electronics. Additionally, an advancement in anti-reflective technology for millimeter waves significantly improves transmission of LFSR's vacuum window while meeting ITER's stringent safety and operational requirements. These results support the continued integration of LFSR into ITER, ensuring its diagnostic capabilities remain resilient under reactor-relevant conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel method for thermal noise reduction, enabling measurements of broadband, low-amplitude electron temperature fluctuations using individual radiometer channels

A new analysis method has been developed for measurements of broadband, low-amplitude turbulent electron temperature fluctuations in fusion plasmas using individual radiometer channels of a correlation electron cyclotron emission diagnostic. This method takes advantage of differences in the correlation time of thermal noise compared to the correlation time of plasma fluctuations in fusion reactors. The validation of this single-channel method is demonstrated using comparisons with the standard dual-channel radiometer spectral decorrelation method for measurements of turbulent electron temperature fluctuations in the core and edge of low confinement (L), improved confinement (I), and high confinement (H)-mode plasmas at the ASDEX Upgrade tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An imaging refractometer for density fluctuation measurements in high energy density plasmas

In this work, we report on a recently developed laser-probing diagnostic which allows direct measurements of ray-deflection angles in one axis, whilst retaining imaging capabilities in the other axis. This allows us to measure the spectrum of angular deflections from a laser beam which passes though a turbulent high-energy-density plasma. This spectrum contains information about the density fluctuations within the plasma, which deflect the probing laser over a range of angles. We create synthetic diagnostics using ray-tracing to compare this new diagnostic with standard shadowgraphy and schlieren imaging approaches, which demonstrates the enhanced sensitivity of this new diagnostic over standard techniques. We present experimental data from turbulence behind a reverse shock in a plasma and demonstrate that this technique can measure angular deflections between 0.06 and 34 mrad, corresponding to a dynamic range of over 500.

47 OTHER INSTRUMENTATION↗

New, improved analysis of correlation ECE data to accurately determine turbulent electron temperature spectra and magnitudes (invited)

Turbulent electron temperature fluctuation measurement using a correlation electron cyclotron emission (CECE) radiometer has become an important diagnostic for studying energy transport in fusion plasmas, and its use is widespread in tokamaks (DIII-D, ASDEX Upgrade, Alcator C-Mod, Tore Supra, EAST, TCV, HL-2A, etc.). The CECE diagnostic typically performs correlation analysis between two closely spaced (within the turbulent correlation length) ECE channels that are dominated by uncorrelated thermal noise emission. This allows electron temperature fluctuations embedded in the thermal noise to be revealed and fluctuation level and spectra determined. We have demonstrated a new, improved CECE coherency-based analysis for calculating the temperature fluctuation frequency spectrum and level, which has been verified both numerically through the simulation of synthetic ECE radiometer data and through analysis of experimental data from the CECE system on DIII-D. The new formulation places coherency-based analysis on a firm foundational footing and corrects some currently published methodologies. This new method accurately accounts for bias error in the coherence function and correctly calculates noise levels for a fixed data record length. It provides excellent accuracy in determining temperature fluctuation level (e.g., <10% error) even for a small realization number in the ensemble average. The method also has a smaller uncertainty (i.e., error bar) in the power spectrum when compared to the more standard cross-power method when evaluated at low coherency. Direct calculation of system noise level using correlation between randomized intermediate frequency signals is recommended.

Wang, G. (ORCID:0000000225739827)↗

Use of diamond sensors for a high-flux, high-rate X-ray pass-through diagnostic

X-ray free-electron lasers (XFELs) deliver pulses of coherent X-rays on the femtosecond time scale, with potentially high repetition rates. While XFELs provide high peak intensities, both the intensity and the centroid of the beam fluctuate strongly on a pulse-to-pulse basis, motivating high-rate beam diagnostics that operate over a large dynamic range. The fast drift velocity, low X-ray absorption and high radiation tolerance properties of chemical vapour deposition diamonds make these crystals a promising candidate material for developing a fast (multi-GHz) pass-through diagnostic for the next generation of XFELs. A new approach to the design of a diamond sensor signal path is presented, along with associated characterization studies performed in the XPP endstation of the LINAC Coherent Light Source (LCLS) at SLAC. Qualitative charge collection profiles (collected charge versus time) are presented and compared with those from a commercially available detector. Quantitative results on the charge collection efficiency and signal collection times are presented over a range of approximately four orders of magnitude in the generated electron–hole plasma density.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗