Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluidic experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Jet Noise Reduction Potential from Emerging Variable Cycle Technologies

Acoustic and flow-field experiments were conducted on exhaust concepts for the next generation supersonic, commercial aircraft. The concepts were developed by Lockheed Martin (LM), Rolls-Royce Liberty Works (RRLW), and General Electric Global Research (GEGR) as part of an N+2 (next generation forward) aircraft system study initiated by the Supersonics Project in NASA s Fundamental Aeronautics Program. The experiments were conducted in the Aero-Acoustic Propulsion Laboratory at the NASA Glenn Research Center. The exhaust concepts utilized ejectors, inverted velocity profiles, and fluidic shields. One of the ejector concepts was found to produce stagnant flow within the ejector and the other ejector concept produced discrete-frequency tones that degraded the acoustic performance of the model. The concept incorporating an inverted velocity profile and fluid shield produced overall-sound-pressure-level reductions of 6 dB relative to a single stream nozzle at the peak jet noise angle for some nozzle pressure ratios. Flow separations in the nozzle degraded the acoustic performance of the inverted velocity profile model at low nozzle pressure ratios.

Henderson, Brenda↗

Jet Noise Reduction Potential From Emerging Variable Cycle Technologies

Acoustic and flow-field experiments were conducted on exhaust concepts for the next generation supersonic, commercial aircraft. The concepts were developed by Lockheed Martin (LM), Rolls-Royce Liberty Works (RRLW), and General Electric Global Research (GEGR) as part of an N+2 (next generation forward) aircraft system study initiated by the Supersonics Project in NASA s Fundamental Aeronautics Program. The experiments were conducted in the Aero-Acoustic Propulsion Laboratory at the NASA Glenn Research Center. The exhaust concepts utilized ejectors, inverted velocity profiles, and fluidic shields. One of the ejector concepts was found to produce stagnant flow within the ejector and the other ejector concept produced discrete-frequency tones that degraded the acoustic performance of the model. The concept incorporating an inverted velocity profile and fluid shield produced overall-sound-pressure-level reductions of 6 dB relative to a single stream nozzle at the peak jet noise angle for some nozzle pressure ratios. Flow separations in the nozzle degraded the acoustic performance of the inverted velocity profile model at low nozzle pressure ratios.

Source record↗

Fiber-Shaped Fluidic Nanogenerator with High Power Density for Self-Powered Integrated Electronics

Flow-based hydrovoltaic nanogenerators have attracted particular attention as efficient and facile miniature energy-harvesting devices. However, they deliver relatively low output power density and limited power conversion efficiency owing to inefficient charge separation and poor charge accumulation. Here, we report the fabrication of high-performance, fiber-shaped fluidic nanogenerators (FFNGs) that use MoS 2 -encapsulated C fibers. The FFNGs deliver stable output voltages of 540 mV and an ultrahigh power density of 10.8 W m -2 . With experiments and density functional theory calculations, improvements in output performance can be attributed to smaller energy requirements for Na + cation adsorption, increased charge separation, and diffusion layer formations on the near surface. Moreover, self-powered, integrated devices achieve a maximum total power conversion-storage efficiency of ~11% and stable output voltage up to 3.1 V, which is applicable for use in consumer electronics devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of Mixing Characteristics for Several Fuel Injectors at Mach 8, 12, and 15 Hypervelocity Flow Conditions

CFD analysis is presented of the mixing characteristics and performance of three fuel injectors at flight Mach numbers of 8, 12, and 15. The Reynolds-averaged simulations (RAS) were carried out using the VULCAN-CFD solver. The high Mach number flow conditions match those of the experiments conducted as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. The EIMP aims to investigate scramjet fuel injection and mixing physics, improve the understanding of underlying physical processes, and develop enhancement strategies relevant to flight Mach numbers greater than 8. The injectors include a fuel placement device, a strut, and a fluidic vortical mixer, a ramp. These fuel injectors accomplish the necessary task of distributing and mixing fuel into the supersonic cross-flow, albeit via different strategies. For comparison, a flush-wall injector is also included. This type of injector generally represents the simplest method of introducing fuel into a scramjet combustor. The three injectors represent the baseline configurations of the EIMP experiments. The mixing parameters of interest, such as mixing efficiency and total pressure recovery, are computed from the RAS and compared for the three flight conditions and injector configurations. In addition to mixing efficiency and total pressure recovery, the combustion efficiency and thrust potential are also computed for the reacting simulations. Plotting the total pressure recovery and thrust potential as a function of mixing efficiency provides added insight into critical aspects of combustor performance as the flight condition and injector type are varied.

Shenoy, Rajiv R.↗

Simulation of Sweep-Jet Flow Control, Single Jet and Full Vertical Tail

This work is a simulation technology demonstrator, of sweep jets used to suppress boundary layer separation and increase maximum achievable load coefficients. A sweep jet is a discrete Coanda jet that oscillates in the plane parallel to an aerodynamic surface. It injects mass and momentum in the approximate stream wise direction. It also generate turbulent eddies at the oscillation frequency, which are typically large relative to boundary layer turbulence, and which augmenting mixing across the boundary layer to attack flow separation. Simulations of a fluidic oscillator, the sweep jet emerging from the oscillator, and the suppression of boundary layer separation by an array of sweep jets are performed. Simulation results are compared to data from a dedicated CFD validation experiment of a single oscillator and its sweep jet, and from a study of a full-scale Boeing 757 vertical tail augmented with an array of sweep jets.2, 20 A critical step in the work is the development of realistic time-dependent sweep-jet in flow boundary conditions, derived from the results of the single-oscillator simulations, which create the sweep jets in the full-tail simulations. Simulations were performed using the Over flow CFD solver, with high-order spatial discretization and a range of turbulence modeling. Good results were obtained for all flows simulated, when suitable turbulence modeling was used.

flow control↗

Simulation of Sweep-Jet Flow Control, Single Jet and Full Vertical Tail

This work is a simulation technology demonstrator, of sweep jet flow control used to suppress boundary layer separation and increase the maximum achievable load coefficients. A sweep jet is a discrete Coanda jet that oscillates in the plane parallel to an aerodynamic surface. It injects mass and momentum in the approximate streamwise direction. It also generates turbulent eddies at the oscillation frequency, which are typically large relative to the scales of boundary layer turbulence, and which augment mixing across the boundary layer to attack flow separation. Simulations of a fluidic oscillator, the sweep jet emerging from a nozzle downstream of the oscillator, and an array of sweep jets which suppresses boundary layer separation are performed. Simulation results are compared to data from a dedicated validation experiment of a single oscillator and its sweep jet, and from a wind tunnel test of a full-scale Boeing 757 vertical tail augmented with an array of sweep jets. A critical step in the work is the development of realistic time-dependent sweep jet inflow boundary conditions, derived from the results of the single-oscillator simulations, which create the sweep jets in the full-tail simulations. Simulations were performed using the computational fluid dynamics (CFD) solver Overow, with high-order spatial discretization and a range of turbulence modeling. Good results were obtained for all flows simulated, when suitable turbulence modeling was used.

flow control↗

Sample Processor for Life on Icy Worlds (SPLIce): Design and Test Results

We report the design, development, and testing of the Sample Processor for Life on Icy Worlds (SPLIce) system, a microfluidic sample processor to enable autonomous detection of signatures of life and measurements of habitability parameters in Ocean Worlds. This monolithic fluid processing-and-handling system (Figure 1; mass 0.5 kg) retrieves a 50-L-volume sample and prepares it to supply a suite of detection instruments, each with unique preparation needs. SPLIce has potential applications in orbiter missions that sample ocean plumes, such as found in Saturns icy moon Enceladus, or landed missions on the surface of icy satellites, such as Jupiters moon Europa. Answering the question Are we alone in the universe? is captivating and exceptionally challenging. Even general criteria that define life very broadly include a significant role for water [1,2]. Searches for extinct or extant life therefore prioritize locations of abundant water whether in ancient (Mars), or present (Europa and Enceladus) times. Only two previous planetary missions had onboard fluid processing: the Viking Biology Experiments [3] and Phoenixs Wet Chemistry Laboratory (WCL) [4]. SPLIce differs crucially from those systems, including its capability to process and distribute L-volume samples and the integration autonomous control of a wide range of fluidic functions, including: 1) retrieval of fluid samples from an evacuated sample chamber; 2) onboard multi-year storage of dehydrated reagents; 3) integrated pressure, pH, and conductivity measurement; 4) filtration and retention of insoluble particles for microscopy; 5) dilution or vacuum-driven concentration of samples to accommodate instrument working ranges; 6) removal of gas bubbles from sample aliquots; 7) unidirectional flow (check valves); 8) active flow-path selection (solenoid-actuated valves); 9) metered pumping in 100 nL volume increments. The SPLIce manifold, made of three thermally fused layers of precision-machined cyclo-olefin polymer, supports all fluidic components (Figure 1) and integrated microchannels (125 x 250 m). Fluid is pumped by a stepper-motor-driven pump (Lee Co.). The functionality of the integrated MEMS pressure sensor (Honeywell) and passive check valves (Figure 2) were tested in conjunction with our newly designed integral bubble traps (Figure 3) and hydrophobic membrane-based concentrator (Figure 4). The concentrator (initially tested as a standalone component) demonstrated 5-fold vacuum-evaporative concentration. Polyethylene fused bead beds (PEFBBs; 50 porosity) store drylyophilized buffers, calibrants, and fluorescent dyes, and also promote mixing of sample with calibrant, dye, or H2O. Software-controlled automated tests demonstrated successful 1) fluid delivery to each component 2) valve and pump synchronization 3) sample aliquot delivery to instrument interface ports, and 4) rehydration of vacuum-dried fluorescent dye. In Figure 5, fluorescein on PEFBBs was rehydrated for 15 min using a pump-delivered water aliquot; it is displaced as H2O enters the bottom of the channel and pushes the dye into a check valve. Ultimately, SPLIce will fluorescently label amino acids in the sample for microchip-based electrophoretic (MCE) chiral separation and detection to seek and quantify key organic bio-signatures [5]; it will also deliver sample to a microfluidic version of WCL (mWCL) to measure soluble ions and redox-active species.

Life detection↗

BioSentinel/Mars: Interplanetary Space Radiation Biosensor Experiment in Martian Transit on Mars 2020

Despite significant progress understanding biological radiation effects via terrestrial studies, no terrestrial source duplicates space’s unique radiation environment. Furthermore, no biological experiments have been conducted beyond low Earth orbit since Apollo. Understanding space’s fundamental biological effects requires overcoming these limitations. The BioSentinel 4U payload, under development for flight aboard Exploration Mission-1, measures biological responses to deep space radiation. Traveling to more than 1AU from Earth, BioSentinel/EM-1 will record DNA double-strand breaks (DSBs) repaired using a pathway common to humans and BioSentinel’s bioengineered yeast model organism, responding to as few as one biologically repaired DSB. The BioSentinel/Mars 4U instrument (6-8kg; 5-8W; 0.2-1MB/week) would include eighteen 16-well biosensor fluidic cards, activated biweekly during Mars 2020’s cruise phase, to provide a dose-dependent rate of DSB/repair. The instrument, which includes solid-state sensors for total ionizing dose and linear-energy-transfer spectra, addresses MEPAG SKG-B3 by simultaneously measuring both spectra and biological effects of space radiation. Biological measurements are rendered reliable by independent replicate experiments. The spatio-temporal uniformity of interplanetary galactic cosmic radiation makes BioSentinel/EM1 and BioSentinel/Mars approximate replicates, except for any major differences in solar particle events. Results will be compared to Earth and ISS controls to characterize the radiation/reduced-gravity parameter space by its biological impact.

BioSentinel↗

Biona-C Cell Culture pH Monitoring System

Sensors 2000! is developing a system to demonstrate the ability to perform accurate, real-time measurements of pH and CO2 in a cell culture media in Space. The BIONA-C Cell Culture pH Monitoring System consists of S2K! developed ion selective sensors and control electronics integrated with the fluidics of a cell culture system. The integrated system comprises a "rail" in the Cell Culture Module (CCM) of WRAIR (Space Biosciences of Walter Read Army Institute of Research). The CCM is a Space Shuttle mid-deck locker experiment payload. The BIONA-C is displayed along with associated graphics and text explanations. The presentation will stimulate interest in development of sensor technology for real-time cell culture measurements. The transfer of this technology to other applications will also be of interest. Additional information is contained in the original document.

Friedericks, C.↗

Evolution of Biological Satellites: From Low Earth Orbit to NASA’s BioSentinel Deep Space Mission

NASA has set its sights on human exploration in deep space with the Artemis missions, with an ambitious plan to put astronauts back on the Moon and to eventually land human missions on Mars. Such missions will require significant countermeasures, likely both technological and biomedical, to protect biology from chronic radiation exposure. Small satellites like CubeSats can inform these countermeasures by querying relevant space environments with model organisms over relevant durations. NASA has launched five biological CubeSats into low Earth orbit (LEO) from GeneSat in 2006 to EcAMSat in 2017. Each one of these missions increased our understanding of the effects of spaceflight, while refining technologies and imparting valuable lessons to the next generation of CubeSats. The Artemis I rocket will carry ten CubeSats, each of them with its own objective. One in particular, BioSentinel, will conduct the first study of the biological response to interplanetary space radiation beyond LEO since Apollo 17. Once it reaches its heliocentric orbit – after a short lunar fly-by – BioSentinel will measure the DNA damage response to ambient radiation in a model organism, the budding yeast Saccharomyces cerevisiae, which will be compared to information provided by an onboard radiation sensor and to data obtained in LEO (on ISS) and on Earth. Once in interplanetary space, fluidic cards containing desiccated yeast cells will be activated by growth medium addition at different time points throughout the mission. Growth and metabolic activity will be tracked continuously via optical density. BioSentinel is a complete, autonomous spacecraft capable of conducting experiments in deep space. Its 4U BioSensor payload is a fully automated and adaptable platform that can perform biological measurements with a range of microorganisms in multiple space environments, including the ISS, free flyers, and other platforms like the Lunar Gateway and lander vehicles.

Sergio R Santa Maria↗

Two-dimensional hydrodynamic viscous electron flow in annular Corbino rings

The concept of fluidic viscosity is ubiquitous in condensed-matter systems hosting a continuum where macroscopic properties can emerge. While an important property of liquids and some solids, only recently was the viscosity of an electron shown to play a role in electronic transport experiments. In this Letter, we present nonlocal electronic transport measurements in concentric annular rings formed in high-mobility two-dimensional electron gases, and the resulting data show that viscous hydrodynamic flow can occur far away from the source-drain current region. Our conclusion of viscous electronic transport is further corroborated by simulations of the Navier-Stokes equations that are found to be in agreement with our measurements below T = 1 K . Finally, this work emphasizes the key role played by viscosity via electron-electron ( e − e ) interaction even when the electronic transport is restricted radially, and for which it should have played no major role. Published by the American Physical Society 2025

Vijayakrishnan, Sujatha (ORCID:0009000080933182)↗

A Review of Recent Advances in Heat Exchanger Technology and Future Applications

This talk describes current and historical efforts concerning the development of condensing heat exchangers for use in space systems. These devices are used for a wide range of applications, including humidity/environmental control and multiphase fluid systems in Earth and in space. Therefore, keeping these systems running consistently and with minimal downtime/repairs is a high priority for exploration life support. Recent advances in low gravity capillary fluidics can be applied to newer systems and offer continuous operation in the event of a system pump failure or blockage. Additionally, new methods in femtosecond laser processing have been used to create microbial resistant surfaces with unique wetting characteristics. This research builds on experiments at both Glenn Research Center and Johnson Space Center. Future applications of this work will also be discussed, including water processing and plant growth systems.

heat exchanger↗

CFD Analysis of Mixing Characteristics of Several Fuel Injectors at Hypervelocity Flow Conditions

CFD analysis is presented of the mixing characteristics and performance of three fuel injectors at hypervelocity flow conditions. The calculations were carried out using the VULCAN-CFD solver and Reynolds-Averaged Simulations (RAS). The high Mach number flow conditions match those proposed for the planned experiments conducted as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. The EIMP aims to investigate scramjet fuel injection and mixing physics, improve the understanding of underlying physical processes, and develop enhancement strategies and functional relationships relevant to flight Mach numbers greater than eight. Because of the high Mach number flow considered, the injectors consist of a fuel placement device, a strut; and a fluidic vortical mixer, a ramp. These devices accomplish the necessary task of distributing and mixing fuel into the supersonic cross-flow albeit via different strategies. Both of these devices were previously studied at lower flight Mach numbers where they exhibited promising performance in terms of mixing efficiency and total pressure recovery. For comparison, a flush-wall injector is also included. This type of injector generally represents the simplest method of introducing fuel into a scramjet combustor, however, at high flight Mach number conditions, the dynamic pressure needed to induce sufficient fuel penetration may be difficult to achieve along with other requirements such as achieving desired levels of fuel-to-air mixing at the required equivalence ratio. The three injectors represent the baseline configurations planned for the experiments. The current work discusses the mixing flow field behavior and differences among the three fuel injectors, mixing performance as described by the mixing efficiency and the total pressure recovery, and performance considerations based on the thrust potential.

Drozda, Tomasz G.↗

Wind Tunnel Testing of AFC over a Deflected Aileron on the High-Lift Common Research Model

Active flow control (AFC) using discrete fluidic actuators distributed along the span, just upstream of the deflected aileron of the 10% scale high-lift version of the Common Research Model (CRM-HL), was evaluated during a wind tunnel test in the NASA Langley 14- by 22-Foot Subsonic Tunnel. For this set of experiments, a new outboard section was fabricated incorporating a deflectable aileron. Aileron deflection angles of 0, 7.5, 16, and 25 were investigated. This experimental investigation is in response to a recent study by Boeing potential to use AFC with a drooped aileron during takeoff to improve lift-to-drag ratio (L/D) by as much as 5%, depending on AFC mass flow rate. AFC is used at deflection angles above the nominal deflection of 7.5 to control the resulting flow separation that occurs and potentially improve L/D. Improvements in aircraft low-speed L/D can affect vehicle range and/or payload. Tuft flow visualization data, steady and unsteady surface pressure data, and force and moment data are used to compare the flowfields with and without AFC. Parameters varied include actuator momentum coefficient and aileron deflection angle. The surface pressure and tuft flow visualization results indicate that without AFC, the flow over a majority of the aileron upper surface is separated for aileron deflection angles larger than 7.5. When AFC is applied, the flow is reattached to the aileron. Force and moment results show that a local increase in lift leads to an increase in L/D of at least 3.5% using mass flow rates thought to be available from air sources onboard a commercial transport.

AFC↗

Wind Tunnel Testing of AFC over a Deflected Aileron on the High-Lift Common Research Model

Active flow control (AFC) using discrete fluidic actuators distributed along the span, just upstream of the deflected aileron of the 10% scale high-lift version of the Common Research Model (CRM-HL), was evaluated during a wind tunnel test in the NASA Langley 14- by 22-Foot Subsonic Tunnel. For this set of experiments, a new outboard section was fabricated incorporating a deflectable aileron. Aileron deflection angles of 0, 7.5, 16, and 25 were investigated. This experimental investigation is in response to a recent study by Boeing potential to use AFC with a drooped aileron during takeoff to improve lift-to-drag ratio (L/D) by as much as 5%, depending on AFC mass flow rate. AFC is used at deflection angles above the nominal deflection of 7.5 to control the resulting flow separation that occurs and potentially improve L/D. Improvements in aircraft low-speed L/D can affect vehicle range and/or payload. Tuft flow visualization data, steady and unsteady surface pressure data, and force and moment data are used to compare the flowfields with and without AFC. Parameters varied include actuator momentum coefficient and aileron deflection angle. The surface pressure and tuft flow visualization results indicate that without AFC, the flow over a majority of the aileron upper surface is separated for aileron deflection angles larger than 7.5. When AFC is applied, the flow is reattached to the aileron. Force and moment results show that a local increase in lift leads to an increase in L/D of at least 3.5% using mass flow rates thought to be available from air sources onboard a commercial transport.

AFC↗

Virtual Shaping of a Two-dimensional NACA 0015 Airfoil Using Synthetic Jet Actuator

The Aircraft Morphing Program at NASA Langley envisions an aircraft without conventional control surfaces. Instead of moving control surfaces, the vehicle control systems may be implemented with a combination of propulsive forces, micro surface effectors, and fluidic devices dynamically operated by an intelligent flight control system to provide aircraft maneuverability over each mission segment. As a part of this program, a two-dimensional NACA 0015 airfoil model was designed to test mild maneuvering capability of synthetic jets in a subsonic wind tunnel. The objective of the experiments is to assess the applicability of using unsteady suction and blowing to alter the aerodynamic shape of an airfoil with a purpose to enhance lift and/or to reduce drag. Synthetic jet actuation at different chordwise locations, different forcing frequencies and amplitudes, under different freestream velocities are investigated. The effect of virtual shape change is indicated by a localized increase of surface pressure in the neighborhood of synthetic jet actuation. That causes a negative lift to the airfoil with an upper surface actuation. When actuation is applied near the airfoil leading edge, it appears that the stagnation line is shifted inducing an effect similar to that caused by a small angle of attack to produce an overall lift change.

Chen, Fang-Jenq↗

Microfluidic Mixing Technology for a Universal Health Sensor

A highly efficient means of microfluidic mixing has been created for use with the rHEALTH sensor an elliptical mixer and passive curvilinear mixing patterns. The rHEALTH sensor provides rapid, handheld, complete blood count, cell differential counts, electrolyte measurements, and other lab tests based on a reusable, flow-based microfluidic platform. These geometries allow for cleaning in a reusable manner, and also allow for complete mixing of fluid streams. The microfluidic mixing is performed by flowing two streams of fluid into an elliptical or curvilinear design that allows the combination of the flows into one channel. The mixing is accomplished by either chaotic advection around micro - fluidic loops. All components of the microfluidic chip are flow-through, meaning that cleaning solution can be introduced into the chip to flush out cells, plasma proteins, and dye. Tests were performed on multiple chip geometries to show that cleaning is efficient in any flowthrough design. The conclusion from these experiments is that the chip can indeed be flushed out with microliter volumes of solution and biological samples are cleaned readily from the chip with minimal effort. The technology can be applied in real-time health monitoring at patient s bedside or in a doctor s office, and real-time clinical intervention in acute situations. It also can be used for daily measurement of hematocrit for patients on anticoagulant drugs, or to detect acute myocardial damage outside a hospital.

Chan, Eugene Y.↗

FLUTE: Fluidic Telescope

The future of space-based UV/optical/IR astronomy requires ever larger telescopes. The highest priority astrophysics targets (including Earth-like exoplanets, first generation stars, and early galaxies) are all extremely faint, which presents an ongoing challenge for current missions and is the opportunity space for next generation telescopes: larger telescopes are the primary way to address this issue. The FLUTE project aims to revolutionize space astronomy (and in-space manufacturing of high-precision optics for a variety of other applications) by leveraging the physics of wetting and hydrostatic phenomena in microgravity. The approach being developed by the team uses surface tension to shape a liquid into a desired optical form with sub-nanometer surface quality. A liquid with appropriate optical properties is brought into contact with a high affinity bounding frame, resulting in pinning of the liquid to the frame. In microgravity, the shape of the free surface is dictated solely by surface tension, thus assuming the shape of a spherical cap. Further dynamic control over the shape is possible through changing the liquid volume, the frame geometry, and — if desired — with the addition of external forces (e.g., electromagnetic forces). The approach is scale-invariant and is expected to enable space telescopes with optical apertures measuring in tens or even hundreds of meters, allowing, for instance, direct imaging of extra-solar planets. Both refractive and reflective optical components can be created using this approach. If the liquid’s properties enable solidification (e.g., a liquid metal), the resulting component can then become an optical-grade solid object, without post-processing steps. The approach has been successfully validated in a laboratory neutral buoyancy environment, in parabolic microgravity flights, and in experiments aboard the International Space Station (ISS). FLUTE is a collaboration between NASA Ames Research Center, NASA Goddard Space Flight Center, and Technion – Israel Institute of Technology. More on information on FLUTE can be found at https://www.nasa.gov/science-research/astrophysics/what-is-the-fluidic-telescope/. This presentation provides an update on the project's accomplishments to-date and discusses next steps.

Space observatory↗