Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluxgate magnetometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The Magnetospheric Multiscale Magnetometers

The success of the Magnetospheric Multiscale mission depends on the accurate measurement of the magnetic field on all four spacecraft. To ensure this success, two independently designed and built fluxgate magnetometers were developed, avoiding single-point failures. The magnetometers were dubbed the digital fluxgate (DFG), which uses an ASIC implementation and was supplied by the Space Research Institute of the Austrian Academy of Sciences and the analogue magnetometer (AFG) with a more traditional circuit board design supplied by the University of California, Los Angeles. A stringent magnetic cleanliness program was executed under the supervision of the Johns Hopkins University,s Applied Physics Laboratory. To achieve mission objectives, the calibration determined on the ground will be refined in space to ensure all eight magnetometers are precisely inter-calibrated. Near real-time data plays a key role in the transmission of high-resolution observations stored onboard so rapid processing of the low-resolution data is required. This article describes these instruments, the magnetic cleanliness program, and the instrument pre-launch calibrations, the planned in-flight calibration program, and the information flow that provides the data on the rapid time scale needed for mission success.

Magnetosphere↗

Psyche Magnetometer Engineering Model Test and Thermal Model Correlation to Validate Operational Thermal Requirement

Psyche Fluxgate Magnetometer candidate fabricated by UCLA has a critical temperature gradient requirement inside the magnetometer sensor head. Since the temperature gradient requirement is a driving factor for the magnetometer operation and science data collection at 16 Psyche, it is critical to validate and verify this requirement via modeling and test. In this work, a thermal vacuum test was completed for Psyche flight-like magnetometer engineering model. Flight-like environments were simulated for a hot operational case (after launch), a cold survival case (cruise), and two cold operational cases to characterize thermal performance of the instrument. An additional, non-flight, steady-state test case was completed to better correlate the magnetometer thermal model. During the test, sensitive Cernox temperature sensors with accuracy of ±0.1°C were used to precisely characterize the temperature gradient and correlate the model to the best accuracy. Collected test data indicated power consumption of 28% lower than predicted. The temperature gradient measured met the expected value and the requirement. Test data indicated the magnetometer also met the AFTs in relevant hot and cold environments. Test Results were used to correlate the thermal model. The correlated thermal model will be integrated to the spacecraft thermal model to predict magnetometer thermal performance while collecting science data in Psyche orbits.

Caron, Ryan↗

The Juno Magnetic Field Investigation

The Juno Magnetic Field investigation (MAG) characterizes Jupiter's planetary magnetic field and magnetosphere, providing the first globally distributed and proximate measurements of the magnetic field of Jupiter. The magnetic field instrumentation consists of two independent magnetometer sensor suites, each consisting of a tri-axial Fluxgate Magnetometer (FGM) sensor and a pair of co-located imaging sensors mounted on an ultra-stable optical bench. The imaging system sensors are part of a subsystem that provides accurate attitude information (to approx. 20 arcsec on a spinning spacecraft) near the point of measurement of the magnetic field. The two sensor suites are accommodated at 10 and 12 m from the body of the spacecraft on a 4 m long magnetometer boom affixed to the outer end of one of 's three solar array assemblies. The magnetometer sensors are controlled by independent and functionally identical electronics boards within the magnetometer electronics package mounted inside Juno's massive radiation shielded vault. The imaging sensors are controlled by a fully hardware redundant electronics package also mounted within the radiation vault. Each magnetometer sensor measures the vector magnetic field with 100 ppm absolute vector accuracy over a wide dynamic range (to 16 Gauss = 1.6 x 10(exp. 6) nT per axis) with a resolution of approx. 0.05 nT in the most sensitive dynamic range (+/-1600 nT per axis). Both magnetometers sample the magnetic field simultaneously at an intrinsic sample rate of 64 vector samples per second. The magnetic field instrumentation may be reconfigured in flight to meet unanticipated needs and is fully hardware redundant. The attitude determination system compares images with an on-board star catalog to provide attitude solutions (quaternions) at a rate of up to 4 solutions per second, and may be configured to acquire images of selected targets for science and engineering analysis. The system tracks and catalogs objects that pass through the imager field of view and also provides a continuous record of radiation exposure. A spacecraft magnetic control program was implemented to provide a magnetically clean environment for the magnetic sensors, and residual spacecraft fields andor sensor offsets are monitored in flight taking advantage of Juno's spin (nominally 2 rpm) to separate environmental fields from those that rotate with the spacecraft.

Juno spacecraft↗

A Web Server for MACCS Magnetometer Data

NASA Grant NAG5-3719 was provided to Augsburg College to support the development of a web server for the Magnetometer Array for Cusp and Cleft Studies (MACCS), a two-dimensional array of fluxgate magnetometers located at cusp latitudes in Arctic Canada. MACCS was developed as part of the National Science Foundation's GEM (Geospace Environment Modeling) Program, which was designed in part to complement NASA's Global Geospace Science programs during the decade of the 1990s. This report describes the successful use of these grant funds to support a working web page that provides both daily plots and file access to any user accessing the worldwide web. The MACCS home page can be accessed at http://space.augsburg.edu/space/MaccsHome.html.

Engebretson, Mark J.↗

Method of Using Power Grid as Large Antenna for Geophysical Imaging

A high-voltage power transmission system is used as an extremely large antenna to extract spatiotemporal space, physical, and geological information from geomagnetically induced currents (GIC). A differential magnetometer method is used to measure GIC and involves acquiring line measurements from a first fluxgate magnetometer under a high-voltage transmission line, acquiring natural field measurements from a reference magnetometer nearby but not under the transmission line, subtracting the natural field measurements from the line measurements, and determining the GIC-related Biot-Savart field from the difference. NASA warning and alarm systems can be triggered based on determinations of GIC amplitude levels that exceed a set threshold value.

Pulkkinen, Antti A.↗

The UOSAT magnetometer experiment

The magnetometer aboard the University of Surrey satellite (UOSAT) and its associated electronics are described. The basic fluxgate magnetometer employed has a dynamic range of plus or minus 8000 nT with outputs digitized by a 12-bit successive approximation A-D converter having a resolution of plus or minus 2 nT. Noise in the 3-13 Hz bandwidth is less than 1 nT. A bias field generator extends the dynamic range to plus or minus 64,000 nT with quantization steps of 8000 nT. The magnetometer experiment is expected to provide information on the secular variation of the geomagnetic field, and the decay rate of the dipole term. Special emphasis will be placed on the acquisition of real time and memory data over the poles which can be correlated with that from Magsat.

Acuna, M. H.↗

A reexamination of ATS 6 magnetometer data for radially polarized Pc 3 magnetic pulsations

The polarization of Pc 3 (22-100 MHz) magnetic pulsations measured by the ATS 6 fluxgate magnetometer at synchronous orbit has been examined by using dynamic autospectral analysis. In contrast to the result obtained by Arthur et al. (1977) using the same data set, very few cases of radially polarized Pc 3 pulsations are found. It is suggested that satellite noise in the radial component, which depends on frequency f as 0.015/f (nT-squared/Hz), is responsible for this disagreement. In the presence of this type of noise, diagonalization of the spectral matrix can produce an erroneous major axis of polarization. Most Pc 3 pulsations classified as radially polarized by Arthur et al. appear to be a consequence of small amplitude azimuthal pulsations contaminated by satellite noise.

Takahashi, K.↗

The MJS-77 magnetometer actuator

A two-position (0 deg and 180 deg) actuating mechanism (flipper) driven by alternately-heated wax motors (pellets) used to rotate the low field triaxial fluxgate magnetometer experiment on the 1977 Mariner Jupiter-Saturn spacecraft to its 0 deg and 180 deg positions is described. The magnetic field, power requirements, weight and volume of this device are discussed. The problems encountered in design and development of this mechanism are presented.

Stange, W. C.↗

The MJS-77 magnetometer actuator

A two-position (0 deg and 180 deg) actuating mechanism (flipper) driven by alternately-heated wax motors (pellets) will be used to rotate the low field triaxial fluxgate magnetometer experiment on the 1977 Mariner Jupiter-Saturn spacecraft to its 0 deg and 180 deg positions. The magnetic field, power requirements, weight and volume of this device are very restrictive. The problems encountered in design and development of this mechanism are presented.

Stange, W. C.↗

The Magsat precision vector magnetometer

This paper examines the Magsat precision vector magnetometer which is designed to measure projections of the ambient field in three orthogonal directions. The system contains a highly stable and linear triaxial fluxgate magnetometer with a dynamic range of + or - 2000 nT (1 nT = 10 to the -9 weber per sq m). The magnetometer electronics, analog-to-digital converter, and digitally controlled current sources are implemented with redundant designs to avoid a loss of data in case of failures. Measurements are carried out with an accuracy of + or - 1 part in 64,000 in magnitude and 5 arcsec in orientation (1 arcsec = 0.00028 deg).

Acuna, M. H.↗

Preliminary calibration plan for the Advanced Particles and Field Observatory (APAFO) magnetometer experiment

Prelaunch and postlaunch calibration plans for the APAFO magnetometer experiment are presented. A study of tradeoffs between boom length and spacecraft field is described; the results are summarized. The prelaunch plan includes: calibration of the Vector Fluxgate Magnetometer (VFM), Star Sensors, and Scalar Helium Magnetometer (SHM); optical bench integration; and acquisition of basic spacecraft field data. Postlaunch calibration has two phases. In phase one, SHM data are used to calibrate the VFM, total vector magnetic field data are used to calibrate a physical model of the spacecraft field, and both calibrations are refined by iteration. In phase two, corrected vector data are transformed into geocentric coordinates, previously undetected spacecraft fields are isolated, and initial geomagnetic field models are computed. Provided the SHM is accurate to the required 1.0 nT and can be used to calibrate the VFM to the required 3.0- nT accuracy, the tradeoff study indicates that a 12 m boom and a spacecraft field model uncertainty of 5 percent together allow the 1.0 nT spacecraft field error requirement to be met.

Voorhies, C. V.↗

Maryland Space Weather UnderGround (SWUG) Educational Outreach Program for Solar Eclipse Study

Space Weather UnderGround (SWUG) is an educational outreach program that provides hands-on experiences in Science, Technology, Engineering, and Mathematics (STEM) to high school and undergraduate students. It has three ultimate goals: 1. Educating the future STEM workforce. 2. Building a cost-effective, research-capable ground 3. magnetometer array across the United States. Collecting geomagnetic field data at high spatial resolution for heliophysics research. SWUG students build, test, and deploy the Simple Aurora Monitor (SAM)-III kit, purchased by Reeve Engineers. The SAM-III kit is a fluxgate magnetometer that measures geomagnetic field changes at a resolution of 1 nT/sec. Dr. Charles Smith initiated the SWUG program at the University of New Hampshire, and it has since expanded to Alaska and Maryland. This presentation introduces the Maryland SWUG activities. The MD-SWUG program was started in the Fall of 2022 with the goal of deploying magnetometers to the solar eclipse sites in 2023 and 2024. Two student-built magnetometers were deployed to the Southwest Research Institute and the Los Alamos National Laboratory for the 2023 annular solar eclipse, with plans to deploy at least four magnetometers to the 2024 total solar eclipse sites, including the University of Texas at Dallas. During a solar eclipse, reduced solar irradiance weakens ionospheric currents and reduces geomagnetic fields by up to 30 nT at the eclipse sites. A recent study suggested that solar eclipses impact geomagnetic fields not only along the eclipse path but also at their magnetic conjugate locations. The SWUG program will help us understand this electrodynamic coupling between the conjugate locations during a solar eclipse by providing better data coverage along the solar eclipse path.

Hyunju Connor↗

The Z3 model of Saturns magnetic field and the Pioneer 11 vector helium magnetometer observations

Magnetic field observations obtained by the Pioneer 11 vector helium magnetometer are compared with the Z(sub 3) model magnetic field. These Pioneer 11 observations, obtained at close-in radial distances, constitute an important and independent test of the Z(sub 3) zonal harmonic model, which was derived from Voyager 1 and Voyager 2 fluxgate magnetometer observations. Differences between the Pioneer 11 magnetometer and the Z(sub 3) model field are found to be small (approximately 1%) and quantitatively consistent with the expected instrumental accuracy. A detailed examination of these differences in spacecraft payload coordinates shows that they are uniquely associated with the instrument frame of reference and operation. A much improved fit to the Pioneer 11 observations is obtained by rotation of the instrument coordinate system about the spacecraft spin axis by 1.4 degree. With this adjustment, possibly associated with an instrumental phase lag or roll attitude error, the Pioneer 11 vector helium magnetometer observations are fully consistent with the Voyager Z(sub 3) model.

Connerney, J. E. P.↗

The Z3 model of Saturn's magnetic field and the Pioneer 11 vector helium magnetometer observations

Magnetic field observations obtained by the Pioneer 11 vector helium magnetometer are compared with the Z(sub 3) model magnetic field. These Pioneer 11 observations, obtained at close-in radial distances, constitute an important and independent test of the Z(sub 3) zonal harmonic model, which was derived from Voyager 1 and Voyager 2 fluxgate magnetometer observations. Differences between the Pioneer 11 magnetometer and the Z(sub 3) model field are found to be small (approximately 1 percent) and quantitatively consistent with the expected instrumental accuracy. A detailed examination of these differences in spacecraft payload coordinates shows that they are uniquely associated with the instrument frame of reference and operation. A much improved fit to the Pioneer 11 observations is obtained by rotation of the instrument coordinate system about the spacecraft spin axis by 1.4 degree. With this adjustment, possibly associated with an instrumental phase lag or roll attitude error, the Pioneer 11 vector helium magnetometer observations are fully consistent with the Voyager Z(sub 3) model.

Connerney, J. E. P.↗

Observations of Electromagnetic Whistler Precursors at Supercritical Interplanetary Shocks

We present observations of electromagnetic precursor waves, identified as whistler mode waves, at supercritical interplanetary shocks using the Wind search coil magnetometer. The precursors propagate obliquely with respect to the local magnetic field, shock normal vector, solar wind velocity, and they are not phase standing structures. All are right-hand polarized with respect to the magnetic field (spacecraft frame), and all but one are right-hand polarized with respect to the shock normal vector in the normal incidence frame. They have rest frame frequencies f(sub ci) < f much < f(sub ce) and wave numbers 0.02 approx < k rho (sub ce) approx <. 5.0. Particle distributions show signatures of specularly reflected gyrating ions, which may be a source of free energy for the observed modes. In one event, we simultaneously observe perpendicular ion heating and parallel electron acceleration, consistent with wave heating/acceleration due to these waves. Al though the precursors can have delta B/B(sub o) as large as 2, fluxgate magnetometer measurements show relatively laminar shock transitions in three of the four events.

Wilson, L. B., III↗