Search NASA⌕ Search

SEARCH · Search NASA

Results for “focal planes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Infrared focal plane arrays for planetary missions

Requirements for infrared detector array focal planes suitable for a set of prospective planetary missions are developed. Using the Galileo mission to Jupiter as a starting point, objectives and constraints applicable to outer planet missions are developed. The concept for an advanced mapping spectrometer utilizing 128 x 128 element infrared detector arrays is described. Specific implementations for the Saturn Orbiter Dual Probe mission, a Mars Orbiter mission, and a Titan Orbiter mission are defined. The analysis indicates that within the 1 to 5 micron range, broad scientific objectives for these missions can be met using focal plane arrays with detectivities on the order of 10 to the 14th cm sq root of Hz per W. The realization of such high detectivities in a low background application will necessitate careful development of the method by which the detector signals are multiplexed and read out.

Wellman, J. B.↗

Visible charge-coupled device (CCD) focal plane design considerations for multispectral applications

The typical Multispectral Linear Array (MLA) Instrument mission would be to gather high-resolution, radiometrically accurate earth resources data in several spectral bands over a prolonged period of time. These bands would include the visible (VIS), near infrared (NIR) and short wavelength infrared. Silicon charge-coupled imaging devices (CCDs) can be assembled into contiguous pixel focal planes which will cover the VIS/NIR region and operate reliably for several years in a space environment. A typical MLA focal plane would have approximately 12,000 pixels, with a pixel-to-pixel registration requirement on the order of + or - 0.1 pixel. The technology to assemble such focal planes has been developed and is described. The problem of polarization sensitivity associated with certain types of focal plane assemblies is addressed. Radiation effects on CCDs are also discussed, and a practical solution to the problem through the use of shielding is described.

Sadowski, H.↗

Monolithic in-based III-V compound semiconductor focal plane array cell with single stage CCD output

A monolithic semiconductor imager includes an indium-based III-V compound semiconductor monolithic active layer of a first conductivity type, an array of plural focal plane cells on the active layer, each of the focal plane cells including a photogate over a top surface of the active layer, a readout circuit dedicated to the focal plane cell including plural transistors formed monolithically with the monolithic active layer and a single-stage charge coupled device formed monolithically with the active layer between the photogate and the readout circuit for transferring photo-generated charge accumulated beneath the photogate during an integration period to the readout circuit. The photogate includes thin epitaxial semiconductor layer of a second conductivity type overlying the active layer and an aperture electrode overlying a peripheral portion of the thin epitaxial semiconductor layer, the aperture electrode being connectable to a photogate bias voltage.

Fossum, Eric R.↗

Monolithic in-based III-V compound semiconductor focal plane array cell with single stage CCD output

A monolithic semiconductor imager includes an indium-based III-V compound semiconductor monolithic active layer of a first conductivity type, an array of plural focal plane cells on the active layer, each of the focal plane cells including a photogate over a top surface of the active layer, a readout circuit dedicated to the focal plane cell including plural transistors formed monolithically with the monolithic active layer and a single-stage charge coupled device formed monolithically with the active layer between the photogate and the readout circuit for transferring photo-generated charge accumulated beneath the photogate during an integration period to the readout circuit. The photogate includes thin epitaxial semiconductor layer of a second conductivity type overlying the active layer and an aperture electrode overlying a peripheral portion of the thin epitaxial semiconductor layer, the aperture electrode being connectable to a photogate bias voltage.

Fossum, Eric R.↗

LWIR scene simulator developed for end-to-end performance evaluation of focal planes

The development of a long-wave infrared optical simulator facilitates evaluation of the end-to-end performance of long wavelength infrared (LWIR) focal plane arrays (FPAs) in a system-like environment. This simulator provides selectable structured scene inputs to a focal plane module or array. Background irradiances as low as 10 exp 10 photons/sq cm s are achievable when the simulator is cooled with liquid helium. The optical simulator can generate single or multiple targets of controllable intensities, and uniform or structured background irradiances. The infrared scenes can be viewed in a stationary mode or dynamically scanned across the focal plane.

Thompson, Niels A.↗

Kalman Filter for Calibrating a Telescope Focal Plane

The instrument-pointing frame (IPF) Kalman filter, and an algorithm that implements this filter, have been devised for calibrating the focal plane of a telescope. As used here, calibration signifies, more specifically, a combination of measurements and calculations directed toward ensuring accuracy in aiming the telescope and determining the locations of objects imaged in various arrays of photodetectors in instruments located on the focal plane. The IPF Kalman filter was originally intended for application to a spaceborne infrared astronomical telescope, but can also be applied to other spaceborne and ground-based telescopes. In the traditional approach to calibration of a telescope, (1) one team of experts concentrates on estimating parameters (e.g., pointing alignments and gyroscope drifts) that are classified as being of primarily an engineering nature, (2) another team of experts concentrates on estimating calibration parameters (e.g., plate scales and optical distortions) that are classified as being primarily of a scientific nature, and (3) the two teams repeatedly exchange data in an iterative process in which each team refines its estimates with the help of the data provided by the other team. This iterative process is inefficient and uneconomical because it is time-consuming and entails the maintenance of two survey teams and the development of computer programs specific to the requirements of each team. Moreover, theoretical analysis reveals that the engineering/ science iterative approach is not optimal in that it does not yield the best estimates of focal-plane parameters and, depending on the application, may not even enable convergence toward a set of estimates.

Kang, Bryan↗

Design and test of the Near Infrared Mapping Spectrometer /NIMS/ focal plane for the Galileo Jupiter Orbiter mission

A Near Infrared Mapping Spectrometer (NIMS) will fly past Jupiter on the Galileo spacecraft in 1982. The infrared detector assembly (focal plane) used in the NIMS instrument is to be passively cooled to 80 K by radiation into space. The focal plane contains 15 InSb and two silicon detectors, each with an associated dual J-FET preamp and feedback resistor. Preliminary fabrication and test experience will be described for an experimental five-channel hybrid detector assembly. Measurements of spectral noise density along with a plasma cleaning technique will also be described. The final NIMS focal plane will contain much of the design experience gained from the experimental hybrid detector assembly.

Bailey, G.↗

Smart focal-plane technology for micro-instruments and micro-rovers

It is inevitable that micro-instruments and micro-rovers for space exploration will contain one or more focal-plane arrays for imaging, spectroscopy, or navigation. In this paper, we explore the state-of-the-art in focal-plane technology for visible sensors. Also discussed is present research activity in advanced focal-plane technology with particular emphasis on the development of smart sensors. The paper concludes with a discussion of possible future directions for the advancement of the technology.

Fossum, Eric R.↗

Smart Focal-Plane Technology for Micro-Instruments and Micro-Rovers

It is inevitable that micro-instruments and micro-rovers for space exploration will contain one or more focal-plane arrays for imaging spectroscopy or navigation. In this paper, we explore the state-if-the-art in focal-plane technology for visible sensors. Also discussed is present research activity in advanced focal-plane technology with particular emphasis on the development of smart sensors. The paper concludes with a discussion of possible future directions for the advancement of the technology.

Fossum, Eric R.↗

SIRTF Focal Plane Survey: A Pre-flight Error Analysis

This report contains a pre-flight error analysis of the calibration accuracies expected from implementing the currently planned SIRTF focal plane survey strategy. The main purpose of this study is to verify that the planned strategy will meet focal plane survey calibration requirements (as put forth in the SIRTF IOC-SV Mission Plan [4]), and to quantify the actual accuracies expected. The error analysis was performed by running the Instrument Pointing Frame (IPF) Kalman filter on a complete set of simulated IOC-SV survey data, and studying the resulting propagated covariances. The main conclusion of this study is that the all focal plane calibration requirements can be met with the currently planned survey strategy. The associated margins range from 3 to 95 percent, and tend to be smallest for frames having a 0.14" requirement, and largest for frames having a more generous 0.28" (or larger) requirement. The smallest margin of 3 percent is associated with the IRAC 3.6 and 5.8 micron array centers (frames 068 and 069), and the largest margin of 95 percent is associated with the MIPS 160 micron array center (frame 087). For pointing purposes, the most critical calibrations are for the IRS Peakup sweet spots and short wavelength slit centers (frames 019, 023, 052, 028, 034). Results show that these frames are meeting their 0.14" requirements with an expected accuracy of approximately 0.1", which corresponds to a 28 percent margin.

pointing↗

Short wavelength infrared hybrid focal plane arrays

The employment of area focal plane arrays (FPA) has made it possible to obtain second generation infrared imaging systems with high resolution and sensitivity. The Short Wavelength Infrared (SWIR) region (1-2.5 microns) is of importance for imaging objects at high temperature and under conditions of reflected sunlight. The present investigation is concerned with electrooptical characterization results for 32 x 32 SWIR detector arrays and FPAs which are suitable for use in a prototype imaging spectrometer. The employed detector material is Hg(1-x)Cd(x)Te grown by liquid phase epitaxy on a CdTe transparent substrate. Attention is given to details of processing, the design of the detector array, the multiplexer, the fabrication of the hybrid FPA, and aspects of performance.

Vural, K.↗

The spectral archive of cosmic X-ray sources observed by the Einstein Observatory Focal Plane Crystal Spectrometer

The Einstein Observatory Focal Plane Crystal Spectrometer (FPCS) used the technique of Bragg spectroscopy to study cosmic X-ray sources in the 0.2-3 keV energy range. The high spectral resolving power (E/Delta-E is approximately equal to 100-1000) of this instrument allowed it to resolve closely spaced lines and study the structure of individual features in the spectra of 41 cosmic X-ray sources. An archival summary of the results is presented as a concise record the FPCS observations and a source of information for future analysis by the general astrophysics community. For each observation, the instrument configuration, background rate, X-ray flux or upper limit within the energy band observed, and spectral histograms are given. Examples of the contributions the FPCS observations have made to the understanding of the objects observed are discussed.

Lum, Kenneth S. K.↗

Curved Focal-Plane Arrays Using Back-Illuminated High-Purity Photodetectors

Curved-focal-plane arrays of back-illuminated silicon-based photodetectors are being developed. The basic idea is to improve the performance of an imaging instrument and simplify the optics needed to obtain a given level of performance by making an image sensor (e.g., a photographic film or an array of photodetectors) conform to a curved focal surface, instead of following the customary practice of designing the optics to project an image onto a flat focal surface. Eyes are natural examples of optical systems that have curved focal surfaces on which image sensors (retinas) are located. One prior approach to implementation of this concept involves the use of curved-input-surface microchannel plates as arrays of photodetectors. In comparison with microchannel plates, these curved-focal-plane arrays would weigh less, operate at much lower voltages, and consume less power. It should also be possible to fabricate the proposed devices at lower cost. It would be possible to fabricate an array of photodetectors and readout circuitry in the form of a very-large-scale integrated (VLSI) circuit on a curved focal surface, but it would be difficult and expensive to do so. In a simple and inexpensive alternate approach, a device (see figure) would have (1) a curved back surface, onto which light would be focused; and (2) a flat front surface, on which VLSI circuitry would be fabricated by techniques that are well established for flat surfaces. The device would be made from ultrapure silicon, in which it is possible to form high-resistivity, thick photodetectors that are fully depleted through their thicknesses. (As used here, "thick means having a thickness between a fraction of a millimeter and a few millimeters.) The back surface would be polished to the curvature of the focal surface of the intended application. To enable the collection of charge carriers excited by photons near the back surface or in the bulk of the device, it would be necessary to form a transparent or semitransparent back-surface electrode, possibly by delta doping. [Delta doping is so named because its density-vs.-depth characteristic is reminiscent of the Dirac function (impulse function): the dopant is concentrated in a very thin layer - nominally, a single atomic layer.]

Nikzad, Shouleh↗

Space telescope optical telescope assembly/scientific instruments. Phase B: Preliminary design and program definition study. Volume 2A. focal plane camera

Trade studies were conducted to ensure the overall feasibility of the focal plane camera in a radial module. The primary variable in the trade studies was the location of the pickoff mirror, on axis versus off-axis. Two alternatives were: (1) the standard (electromagnetic focus) SECO submodule, and (2) the MOD 15 permanent magnet focus SECO submodule. The technical areas of concern were the packaging affected parameters of thermal dissipation, focal plane obscuration, and image quality.

Source record↗

Short wavelength 128 by 128 focal plane arrays for remote sensing applications

Short-wavelength (1-2.5-micron) 128x128 focal plane arrays have been fabricated and demonstrated with high pixel yields and dark-current-limited performance. The detector material is HgCdTe grown by LPE on a sapphire substrate which yields high-performance uniform detectors. The detector arrays were characterized at temperatures of 80-150 K; the peak quantum efficiency at 2.4 microns is 80 percent. The multiplexer is a Reticon FET switch with output amplifiers. It is noted that the long-term goal of this project is to develop a 150x1000 mosaicked focal plane for use in the HIRIS instrument on the Earth Observing System.

Bothwell, Mary↗

Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy

Recent advances in coronagraph technologies for exoplanet imaging have achieved contrasts close to 1e10 at 4 lambda/D and 1e-9 at 2 lambda/D in monochromatic light. A remaining technological challenge is to achieve high contrast in broadband light; a challenge that is largely limited by chromaticity of the focal plane mask. The size of a star image scales linearly with wavelength. Focal plane masks are typically the same size at all wavelengths, and must be sized for the longest wavelength in the observational band to avoid starlight leakage. However, this oversized mask blocks useful discovery space from the shorter wavelengths. We present here the design, development, and testing of an achromatic focal plane mask based on the concept of optical filtering by a diffractive optical element (DOE). The mask consists of an array of DOE cells, the combination of which functions as a wavelength filter with any desired amplitude and phase transmission. The effective size of the mask scales nearly linearly with wavelength, and allows significant improvement in the inner working angle of the coronagraph at shorter wavelengths. The design is applicable to almost any coronagraph configuration, and enables operation in a wider band of wavelengths than would otherwise be possible. We include initial results from a laboratory demonstration of the mask with the Phase Induced Amplitude Apodization coronagraph.

Achromatic↗

High performance GaSb/InAs superlattice long-wave infrared focal plane array

We describe the demonstration of a ¼ VGA format long-wavelength infrared focal plane array based on an InAs/GaSb superlattice absorber surrounded by an electron-blocking and a hole-blocking unipolar barrier. An 8.8 μm cutoff focal plane without antireflection coating based on this complementary barrier infrared detector design has yielded noise equivalent differential temperature of 18.6 mK at operating temperature of 80K, with 300 K background and f/2 cold-stop.

Mumolo, J. M.↗

Design of the focal plane array assembly for the Mars Observer/Visual and Infrared Mapping Spectrometer (MO/VIMS)

A unique focal plane array (FPA) assembly combining both electronic and optical components in a single hermetically sealed hybrid package has been designed to meet the performance requirements imposed on the focal plane assembly in the Visual and Infrared Mapping Spectrometer (VIMS) for the Mars Observer (MO) mission. Inside the FPA package is a configuration of three multiplexed linear arrays containing 320 detector elements, a combination of Si and InSb, allowing continuous spectral coverage from 0.35 to 5.14 microns. An optical subassembly consisting of two spectral order-sorting filters with intrinsic field-of-view apertures requiring critical optical alignment is also internal to the hybrid. Several engineering issues arose during the MO/VIMS FPA development phase which had challenging design ramifications. FPA performance requirements, design approach, and critical issues are discussed.

Niblack, Curtiss A.↗