Search NASA⌕ Search

SEARCH · Search NASA

Results for “force limiting practices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Relationship between student selection criteria and learner success for medical dosimetry students

Medical dosimetry education occupies a specialized branch of allied health higher education. Noted international shortages of health care workers, reduced university funding, limitations on faculty staffing, trends in learner attrition, and increased enrollment of nontraditional students force medical dosimetry educational leadership to reevaluate current admission practices. Program officials wish to select medical dosimetry students with the best chances of successful graduation. The purpose of the quantitative ex post facto correlation study was to investigate the relationship between applicant characteristics (cumulative undergraduate grade point average (GPA), science grade point average (SGPA), prior experience as a radiation therapist, and previous academic degrees) and the successful completion of a medical dosimetry program, as measured by graduation. A key finding from the quantitative study was the statistically significant positive correlation between a student's previous degree and his or her successful graduation from the medical dosimetry program. Future research investigations could include a larger research sample, representative of more medical dosimetry student populations, and additional studies concerning the relationship of previous work as a radiation therapist and the effect on success as a medical dosimetry student. Based on the quantitative correlation analysis, medical dosimetry leadership on admissions committees could revise student selection rubrics to place less emphasis on an applicant's undergraduate cumulative GPA and increase the weight assigned to previous degrees.

61 RADIATION PROTECTION AND DOSIMETRY↗

Magnetic properties of intercalated quasi-2D Fe 3-x GeTe 2 van der Waals magnet

Among several well-known transition metal-based compounds, cleavable van der Waals (vdW) Fe 3-x GeTe 2 (FGT) magnet is a strong candidate for use in two-dimensional (2D) magnetic devices due to its strong perpendicular magnetic anisotropy, sizeable Curie temperature (T C ~154 K), and versatile magnetic character that is retained in the low-dimensional limit. While the T C remains far too low for practical applications, there has been a successful push toward improving it via external driving forces such as pressure, irradiation, and doping. Here we present experimental evidence of a room temperature (RT) ferromagnetic phase induced by the electrochemical intercalation of common tetrabutylammonium cations (TBA+) into quasi-2D FGT. We obtained Curie temperatures as high as 350 K with chemical and physical stability of the intercalated compound. The temperature-dependent Raman measurements, in combination with vdW-corrected ab initio calculations, suggest that charge transfer (electron doping) upon intercalation could lead to the observation of RT ferromagnetism. This work demonstrates that molecular intercalation is a viable route in realizing high-temperature vdW magnets in an inexpensive and reliable manner and has the potential to be extended to bilayer and few-layer vdW magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Proton internal pressure from deeply virtual Compton scattering on collider kinematics

Abstract The unique experimental connection to the QCD energy–momentum tensor offered by generalised parton distributions has been strongly highlighted in the past few years with attempts to extract the pressure and shear forces distributions within the nucleon. If, in principle, this can be performed in a model independent way from experimental data, in practice, the current limited precision and kinematic coverage make such an extraction very challenging. Moreover, the limitation to a leading-order description in the strong coupling of the data has provided only an indirect and weakly sensitive access to gluon degrees of freedom, solely through their mixing to quarks via evolution. In this paper we address this issue by providing a next-to-leading order formalism allowing a reanalysis of global fits with genuine gluonic degrees of freedom. In addition, we provide an estimate of the reduction in uncertainty that could stem from the extended kinematic range relevant for the future Electron Ion Collider. Finally, we stress the connection between the analysis of the dispersion relation in terms of generalised parton distributions and the deconvolution problem.

Dutrieux, H. (ORCID:0000000183344885)↗

A Unified Beam-Dynamics and Hardware Design Framework for Hybrid Nonlinear-Kicker Injection in NSLS-II

Nonlinear kickers (NLKs) enable off-axis injection in ultralow-emittance storage rings by providing a strong kick to the injected beam while remaining nearly transparent to the stored beam. In hybrid schemes, a conventional four-kicker bump defines the injected trajectory, and the NLK reduces the first-turn action under constrained beam offset and optics conditions. Effective operation additionally requires stable and reproducible first-turn injection trajectories. We develop a compact action–angle framework that expresses NLK dynamics in terms of Courant–Snyder invariants and yields an analytical bound on achievable action reduction. This formulation provides direct design rules for NLK placement, phase advance, injected-beam offset, and kicker field profile. Within this framework, we identify the 8-wire NLK as a practical baseline and extend its design by relaxing the square-geometry constraint, enabling inward shifting of the off-axis field peak while preserving on-axis field and gradient cancellation. Application to the NSLS-II lattice shows how aperture, pulsed-power, and mechanical constraints combine to determine a coupled design solution. Multi-turn tracking confirms that candidate NLK locations maintain sufficient stay-clear (aperture-clearance) margin, while the optimized wire geometry reduces the required current and Lorentz force load. The results establish a unified approach for NLK-assisted injection design and provide a practical pathway for upgrades in diffraction-limited storage rings.

36 MATERIALS SCIENCE↗

Hopkinson Bar Impact Force Measurement for Application to Development of an Artificial Bird

A test method has been published for measuring forces from bird cadavers and artificial birds to demonstrate equivalency to support the use of artificial birds in aircraft certification testing. The test method involves a large diameter Hopkinson bar as the technique for measuring and comparing forces. The method involves the assumption that a force on one end of the bar results in a one-dimensional plane wave that travels down the bar. To avoid reflected waves from the end of the bar overlapping the input pulse, and due to practical limitations on the length of the bar, strain transducers are located relatively close to the impacted face of the bar, raising questions about the validity of the assumption of one-dimensional wave propagation. In addition, the large diameter of the bar can introduce dispersion effects in the propagated pulse. These must be assessed to determine the impact on the accuracy of impact force measurements and, if significant, dispersion correction techniques must be used. In this study analytical, experimental, and computational methods are used to analyze the wave propagation characteristics for impact forces expected from realistic bird impacts. While wave dispersion and effects of non-concentric impacts are present, the resulting errors are relatively small. For the response we expect to see in bird impacts up to velocities of approximately 300 m/sec the large diameter Hopkinson bar test appears to be an acceptable method for measuring the impact forces and comparing the response of real and proposed artificial birds.

Birdstrike↗

Active Aerodynamic Load Control for Wind Turbines

The goal of this project was to develop and demonstrate an advanced dielectric barrier discharge (DBD) plasma actuator technology. We set out to demonstrate the efficacy and impact of the new actuator technology as a key component of an active load control system for wind turbines. A DBD plasma actuator consists of a thin layer of dielectric material separating a pair of offset electrodes. One of those electrodes is embedded between the dielectric layer and a non-conductive substrate, while the other is exposed to air. When driven by an appropriate high voltage waveform, the device ionizes the air near the surface of the dielectric and adjacent to the exposed electrode. Collisions between the ions in the plasma and neutral air molecules result in a wall-jet – a region of induced air velocity that can be used to modify the flow around a lifting body. Use of the device near the trailing edge of a wind turbine blade, designed in such a way as to amplify the effects of the flow-modifying device, can result in large changes to the global forces experienced by the blade. Because of the fast response time of the device, it can allow the turbine to react in real time to changes in the wind associated with turbulence, wind shear, gusts, and the like, when paired with appropriate sensors and control algorithms. The goal of this project was to increase the capacity of the device to induce velocity on its surface at the levels required by large, utility-scale wind turbines. The first technical goal was to increase the induced velocity from the current industry-best of about 4 m/s to 10 m/s by modifying the electrical waveform used to drive the device and by introducing a semi-conductive surface coating to control electrostatic charge build-up on the surface. The second goal was to use the device to modify the lift on a representative airfoil in a wind tunnel, demonstrating a reduction in lift coefficient of 0.2 or better. The third goal was to produce an actuator-induced velocity of 20 m/s. Alongside our partners at the University of Texas at Dallas, we also applied modern, advanced design methods to optimize the impact of the technology on the design of wind turbines. We also had planned to install a segmented, active load control system on a test turbine to demonstrate the ability to reduce unsteady aerodynamic forces on the turbine associated with changes in the wind. The highest induced velocity achieved during this research was 11 m/s. However, practical design constraints limited the change in lift coefficient to about 0.12 for a representative airfoil in the wind tunnel at a Reynolds number of 400,000. The primary conclusion is that the plasma actuator control authority remains insufficient for practical purposes when extrapolated to Reynolds numbers over 1 million. The potential impact of the active lift control concept was evaluated through detailed simulations for three wind turbine sizes: a 3.4MW onshore turbine, a 10MW offshore turbine, and a 15MW offshore turbine. A feedback control system was designed for each turbine within two scenarios: one where the active lift control is used as a retrofit capability on the baseline design, and the other where the designers were permitted to “upscale” the turbines in order increase annual energy production. The levelized cost of energy was then evaluated for the range of turbine sizes and design configuration. It was found that the LCOE reduction associated with active lift control fell in the range of 0.7% to 7.2%, with the highest reduction associated with upscaling the 3.4MW turbine.

17 WIND ENERGY↗

Experimental and data analysis techniques for deducing collision-induced forces from photographic histories of engine rotor fragment impact/interaction with a containment ring

An analysis method termed TEJ-JET is described whereby measured transient elastic and inelastic deformations of an engine-rotor fragment-impacted structural ring are analyzed to deduce the transient external forces experienced by that ring as a result of fragment impact and interaction with the ring. Although the theoretical feasibility of the TEJ-JET concept was established, its practical feasibility when utilizing experimental measurements of limited precision and accuracy remains to be established. The experimental equipment and the techniques (high-speed motion photography) employed to measure the transient deformations of fragment-impacted rings are described. Sources of error and data uncertainties are identified. Techniques employed to reduce data reading uncertainties and to correct the data for optical-distortion effects are discussed. These procedures, including spatial smoothing of the deformed ring shape by Fourier series and timewise smoothing by Gram polynomials, are applied illustratively to recent measurements involving the impact of a single T58 turbine rotor blade against an aluminum containment ring. Plausible predictions of the fragment-ring impact/interaction forces are obtained by one branch of this TEJ-JET method; however, a second branch of this method, which provides an independent estimate of these forces, remains to be evaluated.

Yeghiayan, R. P.↗

Truncated Nonlinear Interferometry for Quantum-Enhanced Atomic Force Microscopy

Nonlinear interferometers that replace beam splitters in Mach-Zehnder interferometers with nonlinear amplifiers for quantum-enhanced phase measurements have drawn increasing interest in recent years, but practical quantum sensors based on nonlinear interferometry remain an outstanding challenge. Here, we demonstrate the first practical application of nonlinear interferometry by measuring the displacement of an atomic force microscope microcantilever with quantum noise reduction of up to 3 dB below the standard quantum limit, corresponding to a quantum-enhanced measurement of beam displacement of 1.7 fm/√Hz. Further, we minimize photon backaction noise while taking advantage of quantum noise reduction by transducing the cantilever displacement signal with a weak squeezed state while using dual homodyne detection with a higher power local oscillator. This approach may enable quantum-enhanced broadband, high-speed scanning probe microscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Systematic model researches on the stability limits of the DVL series of float designs

To determine the trim range in which a seaplane can take off without porpoising, stability tests were made of a Plexiglas model, composed of float, wing, and tailplane, which corresponded to a full-size research airplane. The model and full-size stability limits are in good agreement. After all structural parts pertaining to the air frame were removed gradually, the aerodynamic forces replaced by weight forces, and the moment of inertia and position of the center of gravity changed, no marked change of limits of the stable zone was noticeable. The latter, therefore, is for practical purposes affected only by hydrodynamic phenomena. The stability limits of the DVL family of floats were determined by a systematic investigation independent of any particular sea-plane design, thus a seaplane may be designed to give a run free from porpoising.

Sottorf, W.↗

Compliance measurements.

The uses of compliance measurements in linear fracture mechanics are discussed as a technique for determining the crack-extension force vs load, specimen dimensions, and elastic constants. Some practical examples of application are given, including specimen and transducer descriptions, experimental procedure, instrumentation, calculations, measurement precautions, friction effects, and data reduction. The limitations and advantages of compliance measurements are discussed. It is pointed out that good results can be obtained by the compliance method when its measurement precision is not lower than that required for Young's modulus.

Bubsey, R. T.↗

One-step construction of a molybdenum disulfide/multi-walled carbon nanotubes/polypyrrole nanocomposite biosensor for the ex-vivo detection of dopamine in mouse brain tissue

Highlights: • Ex vivo dopamine detection in mouse brain tissues of Parkinson's disease model. • Nanocomposite constructed by one-step electrochemical approach. • The synergetic performance enhancement of the sensor by nanocomposite. We developed a new strategy for construction of a biosensor for the neurotransmitter dopamine. The biosensor was constructed by one-step electrochemical deposition of a nanocomposite in aqueous solution at pH 7.0, consisting of molybdenum disulfide, multi-walled carbon nanotubes, and polypyrrole. A series of analytical methods was performed to investigate the surface characteristics and the improved electrocatalytic effect of the nanocomposite, including cyclic voltammetry, electrochemical impedance spectroscopy, field-emission scanning electron microscopy, atomic force microscopy, and Raman spectroscopy. The constructed biosensor showed high sensitivity (1.130 μAμM{sup −1}cm{sup −2}) with a dynamic linearity range of 25–1000 nM and a detection limit of 10 nM. Additionally, the designed sensor exhibited strong anti-interference ability and satisfactory reproducibility. The practical application of the sensor was manifested for the ex vivo determination of dopamine neurotransmitters using brain tissue samples of a mouse Parkinson's disease model.

60 APPLIED LIFE SCIENCES↗

Ductile adhesive elastomers with force-triggered ultra-high adhesion strength

Elastomers play a vital role in many forthcoming advanced technologies in which their adhesive properties determine materials’ interface performance. Despite great success in improving the adhesive properties of elastomers, permanent adhesives tend to stick to the surfaces prematurely or result in poor contact depending on the installation method. Thus, elastomers with on-demand adhesion that is not limited to being triggered by UV light or heat, which may not be practical for scenarios that do not allow an additional external source, provide a solution to various challenges in conventional adhesive elastomers. Herein, we report a novel, ready-to-use, ultra high-strength, ductile adhesive elastomer with an on-demand adhesion feature that can be easily triggered by a compression force. The precursor is mainly composed of a capsule-separated, two-component curing system. After a force-trigger and curing process, the ductile adhesive elastomer exhibits a peel strength and a lap shear strength of 1.2 × 10 4 N m -1 and 7.8 × 10 3 kPa, respectively, which exceed the reported values for advanced ductile adhesive elastomers. The ultra-high adhesion force is attributed to the excellent surface contact of the liquid-like precursor and to the high elastic modulus of the cured elastomer that is reinforced by a two-phase design. In conclusion, incorporation of such on-demand adhesion into an elastomer enables a controlled delay between installation and curing so that these can take place under their individual ideal conditions, effectively reducing the energy cost, preventing failures, and improving installation processes.

36 MATERIALS SCIENCE↗

Motion and force controlled vibration testing

A technique for controlling both the input acceleration and force in vibration tests is proposed to alleviate the overtesting risks and the problems associated with response limiting in conventional vibration tests of aerospace hardware. Previous research on impedance and force controlled vibration tests is reviewed and a simple equation governing the dual control of acceleration and force is derived. A practical method for implementing the dual control technique in random vibration tests has been demonstrated in JPL's environmental test facility using a conventional digital controller operating in the extremal mode. The dual control technique provides appropriate real-time notching of the input acceleration and a corresponding reduction of the test item response at resonances. Issues concerning the need for force and acceleration phase information, the adequacy of specifying the blocked force, and the derivation of the total force for multipoint supports are discussed.

Scharton, Terry D.↗

Simulation of osmotic pressure in concentrated aqueous salt solutions.

Accurate force fields are critical for meaningful simulation studies of highly concentrated electrolytes. The ion models that are widely used in biomolecular simulations do not necessarily reproduce the correct behavior at finite concentrations. In principle, the osmotic pressure is a key thermodynamic property that could be used to test and refine force field parameters for concentrated solutions. Here we describe a novel, simple, and practical method to compute the osmotic pressure directly from molecular dynamics (MD) simulation of concentrated aqueous solutions by introducing an idealized semipermeable membrane. Simple models for Na+, K+, and Cl- are tested and calibrated to accurately reproduce the experimental osmotic pressure at high salt concentration, up to the solubility limit of 4-5 M. The methodology is general and can be extended to any type of solute as well as nonadditive polarizable force fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scale effects on core design, fuel costs, and spent fuel volume of pressurized water reactors

The desire to improve the economic competitiveness and deployment pace of nuclear energy through modularization, manufacturing, and series production had led to the development of smaller size reactors. As the standard 17x17 fuel technology is mainly maintained in the pressurized water reactors (PWRs) category, this translates into a lower number of fuel assemblies in the core and sometimes a reduced fuel height. To assess the impact of such scale change in core design on fuel cycle cost and spent fuel volume, a scoping analysis tool is developed based on infinite lattice calculations, leakage, fuel management reduced models, and levelized unit cost of electricity (LCOE) estimate. As such, cost dynamics driven by fuel specific power, burnup, core leakage, feed, cycle length, fuel assembly height as well as uranium market data are captured with consistent set of assumptions and analysis methods. A selection of 5 reactor designs representative of leading PWR developers is assessed and compared. Pursuing higher specific powers and optimal burnups are highlighted as the main fuel cost reduction drivers, nevertheless, practical limitations and opportunities must be evaluated to establish the feasibility of such enhanced fuel operation. In consequence, a detailed core design is performed using SIMULATE3 code for 5 PWR variations including natural and forced coolant circulation modes, two reactor scales, power densities of 73, 112, and 123 kW/l and higher discharge burnups. Design and optimization are performed at the lattice level, for the reflector, and at the core loading level. Satisfactory steady-state operation including power distribution, coolant operating limits, and reactivity requirements are analyzed and reported in this paper. The fuel economics of the detailed core designs confirm the scoping analysis findings. Despite the unlocked power uprates in small PWRs, the achievable burnup for a given fuel specific power requires more enrichment and shorter fuel height results in higher fabrication costs per mass of fuel, which makes scaling down core size a more expensive endeavor on the fuel cycle front. Spent fuel volumes are reported for the PWRs designed in this paper. Furthermore, these volumes are driven by the core average discharge burnup regardless of the scale in consideration. Additional cost and core performance aspects related to heavy reflector gains, fuel-reflector substitution, and disposal cost policy in the U.S. are examined.

42 ENGINEERING↗

A boundary integral formalism for stochastic ray tracing in billiards

Determining the flow of rays or non-interacting particles driven by a force or velocity field is fundamental to modelling many physical processes. These include particle flows arising in fluid mechanics and ray flows arising in the geometrical optics limit of linear wave equations. In many practical applications, the driving field is not known exactly and the dynamics are determined only up to a degree of uncertainty. This paper presents a boundary integral framework for propagating flows including uncertainties, which is shown to systematically interpolate between a deterministic and a completely random description of the trajectory propagation. A simple but efficient discretisation approach is applied to model uncertain billiard dynamics in an integrable rectangular domain.

42 ENGINEERING↗

Reward based optimization of resonance-enhanced piezoresponse spectroscopy

Dynamic spectroscopies in scanning probe microscopy (SPM) are critical for probing material properties, such as force interactions, mechanical properties, polarization switching, electrochemical reactions, and ionic dynamics. However, the practical implementation of these measurements is constrained by the need to balance imaging time and data quality. Signal to noise requirements favor long acquisition times and high frequencies to improve signal fidelity. However, these are limited on the low end by contact resonant frequency and photodiode sensitivity and on the high end by the time needed to acquire high-resolution spectra or the propensity for sample degradation under high field excitation over long times. The interdependence of key parameters such as instrument settings, acquisition times, and sampling rates makes manual tuning labor-intensive and highly dependent on user expertise, often yielding operator-dependent results. These limitations are prominent in techniques like dual amplitude resonance tracking in piezoresponse force microscopy that utilize multiple concurrent feedback loops for topography and resonance frequency tracking. Here, a reward-driven workflow is proposed that automates the tuning process, adapting experimental conditions in real time to optimize data quality. Furthermore, this approach significantly reduces the complexity and time required for manual adjustments and can be extended to other SPM spectroscopic methods, enhancing overall efficiency and reproducibility.

47 OTHER INSTRUMENTATION↗