Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency 1.3 GHz”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Evaluation of Anisotropic Magnetoresistive (AMR) Sensors for a Magnetic Field Scanning System for SRF Cavities

One of the significant causes of residual losses in superconducting radio-frequency (SRF) cavities is trapped magnetic flux. The flux trapping mechanism depends on many factors that include cool-down conditions, surface preparation techniques, and ambient magnetic field orientation. Suitable diagnostic tools are not yet available to quantitatively correlate such factors’ effect on the flux trapping mechanism. A magnetic field scanning system (MFSS) consisting of AMR sensors, fluxgate magnetometers, or Hall probes is recently commissioned to scan the local magnetic field of trapped vortices around 1.3 GHz single-cell SRF cavities. In this contribution, we will present results from sensitivity calibration and the first tests of AMR sensors in the MFSS.

Parajuli, I. P.↗

Improving the Performance of Mid-T Baked Niobium Cavities through Post-Bake Surface Treatment

he Medium temperature (mid-T) baking of niobium superconducting radio-frequency cavities at 300 350 C in a vacuum furnace is known to enhance the quality factor (Q₀). However, despite this improvement, cavities treated with this process often exhibit premature quench at relatively low accelerating fields. This limitation is suspected to arise from the formation of surface contaminants, such as niobium carbides, during the furnace bake at 350 C for 3 h. To investigate the influence of potential surface contamination, this study applied an ultralight chemical removal to 1.3 GHz and 650 MHz single-cell cavities that had undergone medium-temperature baking. The removal of the top RF surface layer led to a notable improvement in the quench field and Q₀, indicating a beneficial effect of eliminating possible surface residues introduced during the bake.

Chouhan, Vijay [Fermilab]↗

Improving the performance of mid-T baked niobium cavities through post-bake surface treatment

The Medium temperature (mid-T) baking of niobium superconducting radio-frequency cavities at 300 350 C in a vacuum furnace is known to enhance the quality factor (Q₀). However, despite this improvement, cavities treated with this process often exhibit premature quench at relatively low accelerating fields. This limitation is suspected to arise from the formation of surface contaminants, such as niobium carbides, during the furnace bake at 350 C for 3 h. To investigate the influence of potential surface contamination, this study applied an ultralight chemical removal to 1.3 GHz and 650 MHz single-cell cavities that had undergone medium-temperature baking. The removal of the top RF surface layer led to a notable improvement in the quench field and Q₀, indicating a beneficial effect of eliminating possible surface residues introduced during the bake.

Chouhan, V. [Fermilab] (ORCID:0000000282004931)↗

Results of High Order Modes Spectra Measurements in 1.3 GHz Cavities for LCLS-II

Fermilab recently completed production and testing of 1.3 GHz cryomodules for the LCLS-II project. Each cryomodule consists of eight TESLA-shaped superconducting elliptical cavities equipped with two High Order Mode (HOM) coupler ports. Measurement of the HOM spectrum is part of the incoming quality control of cavities at room temperature and the final qualification cold test of cryomodules at the Cryomodule Test Facility (CMTF). In this paper we describe the procedure for measuring the HOM spectrum along with further data processing. Finally, we present accumulated statistics of individual HOM frequencies and quality factors related to various cavity vendors and discuss the possible contribution of HOMs to heat loads and beam dynamics.

43 PARTICLE ACCELERATORS↗

MAGNETIC FLUX EXPULSION IN SUPERCONDUCTING RADIO-FREQUENCY NIOBIUM CAVITIES MADE FROM COLD WORKED NIOBIUM

Trapped residual magnetic field during the cool down of superconducting radio frequency (SRF) cavities is one of the primary sources of RF residual losses leading to lower quality factor. Historically, SRF cavities have been fabricated from high purity fine grain niobium with grain size ~50 to 100 µm as well as large grain with grain size of the order of few centimeters. Non-uniform recrystallization of fine-grain Nb cavities after the post fabrication heat treatment leads to higher flux trapping during the cool down, and hence the lower quality factor. We fabricated two 1.3 GHz single cell cavities from cold-worked niobium from different vendors and processed along with cavities made from SRF grade Nb. The flux expulsion and flux trapping sensitivity were measured after successive heat treatments in the range 800 to 1000°C. The flux expulsion from cold-worked fine-grain Nb cavities improves after 800°C/3h heat treatments and it becomes similar to that of standard fine-grain Nb cavities when the heat treatment temperature is higher than 900°C.

Khanal, B. D.↗

MAGNETIC FLUX EXPULSION IN SUPERCONDUCTING RADIO-FREQUENCY NIOBIUM CAVITIES MADE FROM COLD WORKED NIOBIUM

Trapped residual magnetic field during the cool down of superconducting radio frequency (SRF) cavities is one of the primary sources of RF residual losses leading to lower quality factor. Historically, SRF cavities have been fabricated from high purity fine grain niobium with grain size ~50 to 100 µm as well as large grain with grain size of the order of few centimeters. Non-uniform recrystallization of fine-grain Nb cavities after the post fabrication heat treatment leads to higher flux trapping during the cool down, and hence the lower quality factor. We fabricated two 1.3 GHz single cell cavities from cold-worked niobium from different vendors and processed along with cavities made from SRF grade Nb. The flux expulsion and flux trapping sensitivity were measured after successive heat treatments in the range 800 to 1000°C. The flux expulsion from cold-worked fine-grain Nb cavities improves after 800°C/3h heat treatments and it becomes similar to that of standard fine-grain Nb cavities when the heat treatment temperature is higher than 900°C.

Khanal, B. D.↗

Event Horizon Telescope observations of the jet launching and collimation in Centaurus A

AbstractVery-long-baseline interferometry (VLBI) observations of active galactic nuclei at millimetre wavelengths have the power to reveal the launching and initial collimation region of extragalactic radio jets, down to 10–100 gravitational radii (rg ≡ GM/c2) scales in nearby sources1. Centaurus A is the closest radio-loud source to Earth2. It bridges the gap in mass and accretion rate between the supermassive black holes (SMBHs) in Messier 87 and our Galactic Centre. A large southern declination of −43° has, however, prevented VLBI imaging of Centaurus A below a wavelength of 1 cm thus far. Here we show the millimetre VLBI image of the source, which we obtained with the Event Horizon Telescope at 228 GHz. Compared with previous observations3, we image the jet of Centaurus A at a tenfold higher frequency and sixteen times sharper resolution and thereby probe sub-lightday structures. We reveal a highly collimated, asymmetrically edge-brightened jet as well as the fainter counterjet. We find that the source structure of Centaurus A resembles the jet in Messier 87 on ~500 rg scales remarkably well. Furthermore, we identify the location of Centaurus A’s SMBH with respect to its resolved jet core at a wavelength of 1.3 mm and conclude that the source’s event horizon shadow4 should be visible at terahertz frequencies. This location further supports the universal scale invariance of black holes over a wide range of masses5,6.

79 ASTRONOMY AND ASTROPHYSICS↗

HOM Spectra Measurements in 1.3 GHz Cavities for LCLS-II

Fermilab recently completed production and testing of 1.3 GHz cryomodules for the LCLS-II project. Each cryomodule consists of eight TESLA-shaped super-conducting elliptical cavities equipped with two High Order Mode (HOM) coupler ports. Measurement of the HOM spectrum is part of the incoming quality control of cavities at room temperature and the final qualification cold test of cryomodules at the Cryomodule Test Facility (CMTF). In this paper we describe the procedure for measuring the HOM spectrum along with further data processing. Finally, we present accumulated statistics of individual HOM frequencies and quality factors related to various cavity vendors and dis-cuss the possible contribution of HOMs to heat loads and beam dynamics.

Lunin, A.↗

Role of microstructure on flux expulsion of superconducting radio frequency cavities

The trapped residual magnetic flux during the cool-down due to the incomplete Meissner state is a significant source of radio frequency losses in superconducting radio frequency cavities. Here, in this study, we clearly correlate the niobium microstructure in elliptical cavity geometry and flux expulsion behavior. In particular, a traditionally fabricated Nb cavity half-cell from an annealed poly-crystalline Nb sheet after an 800 °C heat treatment leads to a bi-modal microstructure that ties in with flux trapping and inefficient flux expulsion. This non-uniform microstructure is related to varying strain profiles along the cavity shape. A novel approach to prevent this non-uniform microstructure is presented by fabricating a 1.3 GHz single cell Nb cavity with a cold-worked sheet and subsequent heat treatment leading to better flux expulsion after 800 °C/3 h. Microstructural evolution by electron backscattered diffraction-orientation imaging microscopy on cavity cutouts, and flux pinning behavior by dc-magnetization on coupon samples confirms a reduction in flux pinning centers with increased heat treatment temperature. The heat treatment temperature-dependent mechanical properties and thermal conductivity are reported. The significant impact of cold work in this study demonstrates clear evidence for the importance of the microstructure required for high-performance superconducting cavities with reduced losses caused by magnetic flux trapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First Very Long Baseline Interferometry Detections at 870μm

The first very long baseline interferometry (VLBI) detections at 870$\mu$m wavelength (345$\,$GHz frequency) are reported, achieving the highest diffraction-limited angular resolution yet obtained from the surface of the Earth, and the highest-frequency example of the VLBI technique to date. These include strong detections for multiple sources observed on inter-continental baselines between telescopes in Chile, Hawaii, and Spain, obtained during observations in October 2018. The longest-baseline detections approach 11$\,$G$\lambda$ corresponding to an angular resolution, or fringe spacing, of 19$\mu$as. The Allan deviation of the visibility phase at 870$\mu$m is comparable to that at 1.3$\,$mm on the relevant integration time scales between 2 and 100$\,$s. The detections confirm that the sensitivity and signal chain stability of stations in the Event Horizon Telescope (EHT) array are suitable for VLBI observations at 870$\mu$m. Operation at this short wavelength, combined with anticipated enhancements of the EHT, will lead to a unique high angular resolution instrument for black hole studies, capable of resolving the event horizons of supermassive black holes in both space and time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of the ASME Boiler and Pressure Vessel Code in the Design of SRF Cavities at Fermilab

Jacketed Superconducting Radio Frequency (SRF) cavities structurally comprise of an inner niobium vessel surrounded by a liquid helium containment vessels. The pressure of the helium bath and/or its volume might be such that a jacketed SRF cavity shall be considered a system of pressure vessels. Thus, methods described in the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (BPVC) should be used to analyze the structural soundness of jacketed SRF cavities. This paper will report the use of the set of rules developed at Fermilab for the design of SRF cavities, such as jacketed 1.3 GHz cavities for LCLS-II HE and jacketed Single Spoke Resonator type~2 (SSR2) for PIP-II, to ensure a similar level of safety as prescribed by the ASME BPVC.

43 PARTICLE ACCELERATORS↗

Modeling of Thermal Quench in Superconducting RF Cavities

Superconducting radio frequency (SRF) cavities are often limited by thermal quench, which is an excessive electromagnetic heating that occurs in the high magnetic field area and expands thereafter forcing the cavity to lose its superconducting state. In this paper, we demonstrate how the quench phenomena can be modeled using a coupled electromagnetic thermal analysis. The proposed model takes into account the nonlinearity of the material properties at cryogenic temperature and the effect of Kapitza resistance. The proposed approach is used to compute the thermal quench field of a 3.9 GHz 9-cell accelerating cavity, a 2.815 GHz deflecting cavity, and a 1.3GHz 9-cell accelerating cavity. Here, the computed values of quenchfield are in good agreement with the measured ones observedduring vertical testing at 2 K. Without loss of generality, theproposed methodology can be applied to other cavity geometries.

43 PARTICLE ACCELERATORS↗

Insight to the Duration of 120 °C Baking on the Performance of SRF Niobium Cavities

Low-temperature baking at 100 °C - 140 °C in ultra-high vacuum for several hours is the final cavity processing technique to achieve the highest accelerating gradient cavity by eliminating the high field Q-slope, typically on cavities made of high purity fine grain niobium and subjected to electropolishing. The temperature and duration of baking control the onset of the high field Q-slope and overall quality factor over the baseline measurements. The increase in quality factor is generally related to the reduction in the temperature-dependent surface resistance, which refers to BCS surface resistance due to the reduction in the electronic mean free path and elimination of high field Q-slope is still being actively investigated. Here, we present the results of a series of measurements on 1.3 GHz TESLA shape single-cell cavities with successive low-temperature baking at 120 °C up to 96 hours. The rf loss related to the trapping of residual magnetic field refer to flux trapping sensitivity was measured with respect to the duration of 120 °C bake.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Residual loss due to magnetic flux trapping in niobium superconducting microwave cavities

One of the significant source of radio frequency loss in superconducting microwave cavities is the trapped residual magnetic field during the cooldown due to the incomplete Messier effect. The sensitivity of flux trapping depends on the distribution of impurities, network of dislocations and defects which pin vortices. Recent advancement in cavity processing techniques resulted in very high quality factors with impurity doping, however the rf loss related to the flux trapping increases. High quality factor in SRF cavities is not only limited to particle accelerators but also emerging as an application to quantum computing and quantum information science. In this presentation, we present the results of measurements of flux trapping sensitivity on several 1.3 GHz elliptical accelerating cavities with different grain size, impurity content and surface preparations.

Dhakal, P.↗

IMPACT OF MEDIUM TEMPERATURE HEAT TREATMENT ON FLUX TRAPPING SENSITIVITY IN SRF CAVITIES

The effect of mid-T heat treatment on flux trapping sensitivity was measured on several 1.3 GHz single cell cavities subjected to medium temperature vacuum annealing at temperature of 150 - 400 ?C for a duration of 3 hours. The cavity was cooldown with residual magnetic field ?0 and ?20 mG in Dewar with cooldown condition of full flux trapped. The quality factor as a function of accelerating gradient was measured. The results show the correlation between the treatment temperature, quality factor, and sensitivity to flux trapping. Sensitivity increases with increasing heat treatment temperatures within the range of (200 - 325 ?C/3h).Moreover, variations in the effective penetration depth ofthe magnetic field and the density of quasi-particles can occur,influencing alterations in the cavity?s electromagneticresponse and resonance frequency.

Dhakal, P.↗

Magnetic field mapping of superconducting radio frequency cavities

Superconducting radio frequency (SRF) cavities are the fundamental building blocks of modern particle accelerators. Niobium is the material of choice to build such cavities. These cavities require a cryogenic cool-down to ~2 ? 4 K for optimum performance minimizing RF losses on the inner cavity surface. However, temperature-independent residual losses in SRF cavities cannot be prevented entirely. One of the major sources of residual losses is trapped magnetic flux. The flux trapping mechanism depends on different factors, such as surface preparations and cool-down conditions. We have developed a diagnostic magnetic field scanning system (MFSS) using Hall probes and anisotropic magneto-resistance sensors to study the spatial distribution of trapped flux in 1.3 GHz single-cell cavities. The first result from this newly commissioned system revealed that the trapped flux on the cavity surface might redistribute with increasing RF power. The MFSS was also able to capture significant magnetic field enhancement at specific cavity locations after a quench.

Parajuli, Ishwari↗

Characterization of Losses in Superconducting Radio-Frequency Cavities by Combined Temperature and Magnetic Field Mapping

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 -10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two novel diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system (MFSS) which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. The second setup is a stationary, combined magnetic and temperature mapping system which uses AMR sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. The MFSS system revealed a non-uniform distribution of trapped flux on the cavities' surface, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature. The MFSS shows that magnetic field scanning as a function of the RF field indicates redistribution of trapped flux at some locations. About ~ 33% of hot-spots observed by temperature mapping during high power RF tests overlapped with the high B-field spots. Almost all high B-field spots observed after field-cool were found to be overlapped on grain boundaries. A clear correlation between the hot- spot formed after quench and local trapped flux was found, providing insight on the RF dissipation of trap vortices. The combined B&T map system showed that the T-map system is capable of detecting hot-spots and quench location on the surface of the 3 GHz SRF cavity. Different distribution of trapped flux was measured after different cool-down and residual B-field, but, no variation in magnetic field distribution was observed during quench, possibly due to magnetic sensors being far from the quench location.

Parajuli, Ishwari↗

High resolution diagnostic tools for superconducting radio frequency cavities

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 –10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two high-resolution diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system, which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. This setup has a spatial resolution of ~ 13 μm in the azimuthal direction and ~ 1 cm along the cavity contour. The second setup is a stationary, combined magnetic and temperature mapping system, which uses anisotropic magnetoresistance sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. This system has a spatial resolution of 5 mm close to the iris and 11 mm at the equator. Initial results show a non-uniform distribution of trapped flux on the cavities’ surfaces, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗