Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Results from extended range SRF cavity tuner tests for LCLS-II-HE

The LCLS-II HE superconducting linac can produce multi-energy beams by supporting multiple undulator lines simultaneously. This could be achieved by using the cavity SRF tuner in the off-frequency detune mode. This off-frequency operation method was tested in 8 cryomodules at Fermilab at 2 K. In all the tests the tuners successfully achieved a frequency shift of -565±80 kHz from the 1.3 GHz value. This study discusses the cavity frequency during each stage of assembly from the cryomodule string to when they are finally tested at 2 K. Monitoring the cavity frequency from this initial stage contributed in reaching this large frequency shift. The specific procedures of tuner setting during assembly will be presented.

43 PARTICLE ACCELERATORS↗

Spectral control of nonclassical light pulses using an integrated thin-film lithium niobate modulator

Abstract Manipulating the frequency and bandwidth of nonclassical light is essential for implementing frequency-encoded/multiplexed quantum computation, communication, and networking protocols, and for bridging spectral mismatch among various quantum systems. However, quantum spectral control requires a strong nonlinearity mediated by light, microwave, or acoustics, which is challenging to realize with high efficiency, low noise, and on an integrated chip. Here, we demonstrate both frequency shifting and bandwidth compression of heralded single-photon pulses using an integrated thin-film lithium niobate (TFLN) phase modulator. We achieve record-high electro-optic frequency shearing of telecom single photons over terahertz range (±641 GHz or ±5.2 nm), enabling high visibility quantum interference between frequency-nondegenerate photon pairs. We further operate the modulator as a time lens and demonstrate over eighteen-fold (6.55 nm to 0.35 nm) bandwidth compression of single photons. Our results showcase the viability and promise of on-chip quantum spectral control for scalable photonic quantum information processing.

Optics↗

Distributed Brillouin fiber laser sensor

Brillouin fiber sensors can provide distributed strain and temperature measurements over long distances in standard off-the-shelf fiber by measuring the Brillouin frequency shift as a function of position along a fiber. The primary drawback of these systems is their limited sensitivity, which results from the challenge in identifying the Brillouin frequency shift to within a small fraction of the Brillouin linewidth. In this work, we introduce a technique that overcomes this fundamental limitation by establishing a series of lasing modes that experience Brillouin amplification at discrete spatial locations in the test fiber. The linewidth narrowing and high intensity associated with the lasing transition enable precise measurements of this lasing frequency. As an initial demonstration, we present a sensor that simultaneously excites 40 lasing modes in a 400 m fiber, providing a measurement of the strain at 40 discrete locations with a spatial resolution of 4 m. Each sensor exhibits a minimum detectable strain as low as 4 nε/Hz 1/2 with a dynamic range of >5 mε and a bandwidth of ~10 kHz. As the first demonstration that Brillouin lasing can be used for distributed fiber sensing, this work establishes an approach that could enable ultra-high strain sensitivity using off-the-shelf fiber.

47 OTHER INSTRUMENTATION↗

Integrated microwave acousto-optic frequency shifter on thin-film lithium niobate

Electrically driven acousto-optic devices that provide beam deflection and optical frequency shifting have broad applications from pulse synthesis to heterodyne detection. Commercially available acousto-optic modulators are based on bulk materials and consume Watts of radio frequency power. Here, we demonstrate an integrated 3-GHz acousto-optic frequency shifter on thin-film lithium niobate, featuring a carrier suppression over 30 dB. Further, we demonstrate a gigahertz-spaced optical frequency comb featuring more than 200 lines over a 0.6-THz optical bandwidth by recirculating the light in an active frequency shifting loop. Our integrated acousto-optic platform leads to the development of on-chip optical routing, isolation, and microwave signal processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Robust Vector BOTDA Signal Processing with Probabilistic Machine Learning

This paper presents a novel probabilistic machine learning (PML) framework to estimate the Brillouin frequency shift (BFS) from both Brillouin gain and phase spectra of a vector Brillouin optical time-domain analysis (VBOTDA). The PML framework is used to predict the Brillouin frequency shift (BFS) along the fiber and to assess its predictive uncertainty. We compare the predictions obtained from the proposed PML model with a conventional curve fitting method and evaluate the BFS uncertainty and data processing time for both methods. The proposed method is demonstrated using two BOTDA systems: (i) a BOTDA system with a 10 km sensing fiber and (ii) a vector BOTDA with a 25 km sensing fiber. The PML framework provides a pathway to enhance the VBOTDA system performance.

47 OTHER INSTRUMENTATION↗

Doppler Lidar (DL) Instrument Handbook

The Doppler lidar (DL) is an active remote sensing instrument that provides range- and time-resolved measurements of radial velocity and attenuated backscatter. The principle of operation is similar to radar in that pulses of energy are transmitted into the atmosphere; the energy scattered back to the transceiver is collected and measured as a time-resolved signal. From the time delay between each outgoing transmitted pulse and the backscattered signal, the distance to the scatterer is inferred. The radial or line-of-sight velocity of the scatterers is determined from the Doppler frequency shift of the backscattered radiation. The DL uses a heterodyne detection technique in which the return signal is mixed with a reference laser beam (i.e., local oscillator) of known frequency. An onboard signal processing computer then determines the Doppler frequency shift from the spectra of the heterodyne signal. The energy content of the Doppler spectra can also be used to determine attenuated backscatter.

99 GENERAL AND MISCELLANEOUS↗

High-fidelity imaging of a band insulator in a three-dimensional optical lattice clock

Here, we report on the observation of a high-density, band insulating state in a three-dimensional optical lattice clock. Filled with a nuclear-spin-polarized degenerate Fermi gas of 87 Sr, the three-dimensional (3D) lattice has one atom per site in the ground motional state, thus guarding against frequency shifts due to contact interactions. At this high density where the average distance between atoms is comparable to the probe wavelength, conventional imaging techniques at saturation intensity suffer from large systematic errors. To spatially probe frequency shifts in the clock and measure thermodynamic properties of this system, accurate imaging techniques at high optical depths are required. Using a combination of highly saturated fluorescence and absorption imaging, we confirm the density distribution in our 3D optical lattice in agreement with a single spin band insulating state. Combining our clock platform with this high filling fraction opens the door to studying new classes of long-lived, many-body states arising from dipolar interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Two-phase accurate multiplexed structured image capture (2pAc-MUSIC)

Multiplexed Structural Image Capture (MUSIC) technique uses modulation of light from a scene prior to imaging to encode the temporal evolution of target into spatial frequency shifts, with each shift corresponding to a unique time and resulting in individual distinct snapshots. Computational-processing of the multiplexed single-shot image can recover the nanosecond-resolution scene evolution. One of the limitations is the loss of spatial resolution of the recovered image due to limitations of the low-pass spatial frequency filtering depth. Here we demonstrated that two images with complementary spatial phases can be used to enhance the spatial resolutions. For this application, 2 Phase Accurate (2pAc)-MUSIC is implemented that a scene is encoded with two complementary phases. The increased spatial information captured reduces the lower frequency noise in the Fourier domain found in single-phase MUSIC. A recovery algorithm combines the 180-degree spatial frequency shifted images into a single scene and applies a spatial filter in the Fourier domain that has a larger depth than previously possible to achieve a scene with increased spatial resolution. The 2pAc-MUSIC can effectively enhance the spatial resolution by removing the overlapping zero-order spatial frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetotropic susceptibility

The magnetotropic susceptibility is the thermodynamic coefficient associated with the rotational anisotropy of the free energy in an external magnetic field and is closely related to the magnetic susceptibility. It emerges naturally in frequency-shift measurements of oscillating mechanical cantilevers, which are becoming an increasingly important tool in the quantitative study of the thermodynamics of modern condensed-matter systems. Here, in this work, we discuss the basic properties of the magnetotropic susceptibility as they relate to the experimental aspects of frequency-shift measurements, as well as to the interpretation of those experiments in terms of the intrinsic properties of the system under study.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Flux-driven algebraic damping of m = 2 diocotron mode

Experiments with pure electron plasmas in a Malmberg–Penning trap have observed linear in time, algebraic damping of m = 2 diocotron modes. Transport due to small field asymmetries produces a low-density halo of electrons moving radially outward from the plasma core, and the mode damping begins when the halo reaches the resonant radius of the mode. The damping rate is proportional to the flux of halo particles through the resonant layer. The damping is related to, but distinct from spatial Landau damping in which a linear wave–particle resonance produces exponential damping. This paper reports an analytic theory that captures the main signatures reported for this novel damping, namely, that the damping begins when the halo particles reach the resonant radius and that the damping is algebraic in time with nearly constant damping rate. The model also predicts a nonlinear frequency shift. The model provides two ways to think about the damping. It results from a transfer of canonical angular momentum from the mode to halo particles being swept by the mode field through the nonlinear cat's eye orbits of the resonant region. More mechanistically, the electric field produced by the perturbed charge density of the resonant particles acts back on the plasma core causing E × B drift that gives rise to the damping and nonlinear frequency shift.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

One- and two-qubit gate infidelities due to motional errors in trapped ions and electrons

In this work, we derive analytic formulas that determine the effect of error mechanisms on one- and two-qubit gates in trapped ions and electrons. First, we analyze and derive expressions for the effect of driving field inhomogeneities on one-qubit gate fidelities. Second, we derive expressions for two-qubit gate errors, including static motional frequency shifts, trap anharmonicities, field inhomogeneities, heating, and motional dephasing. We show that, for small errors, each of our expressions for infidelity converges to its respective numerical simulation; this shows that our formulas are sufficient for determining error budgets for high-fidelity gates, obviating numerical simulations in future projects. All of the derivations are general to any internal qubit state, and any mixed state of the ion crystal's motion that is diagonal in the Fock state basis. Our treatment of static motional frequency shifts, trap anharmonicities, heating, and motional dephasing apply to both laser-based and laser-free gates, while our treatment of field inhomogeneities applies to laser-free systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Time-lens photon Doppler velocimetry (TL-PDV)

Here, we describe a time lens (TL) to expand the dynamic range of photon Doppler velocimetry (PDV) systems. The principle and preliminary design of a TL-PDV system are explained and shown to be feasible through simulations. In a PDV system, an interferometer is used for measuring frequency shifts due to the Doppler effect from the target motion. However, the sampling rate of the electronics could limit the velocity range of a PDV system. A four-wave-mixing (FWM) TL applies a quadratic temporal phase to an optical signal within a nonlinear FWM medium (such as an integrated photonic waveguide or a highly nonlinear optical fiber). By spectrally isolating the mixing product, termed the idler, and with appropriate lengths of dispersion prior to and after this FWM TL, a temporally magnified version of the input signal is generated. Therefore, the frequency shifts of PDV can be “slowed down” with the magnification factor M of the TL. M = 1 corresponds to a regular PDV system without a TL. M = 10 has been shown to be feasible for a TL-PDV system. The use of this effect for PDV can expand the velocity measurement range and allow for the use of lower bandwidth electronics. TL-PDV will open up new avenues for various dynamic material experiments.

47 OTHER INSTRUMENTATION↗

Time Refraction of Spin Waves

Here, we present an experimental study of time refraction of spin waves (SWs) propagating in microscopic waveguides under the influence of time-varying magnetic fields. Using space- and time-resolved Brillouin light scattering microscopy, we demonstrate that the broken translational symmetry along the time coordinate results in a loss of energy conservation for SWs and thus allows for a broadband and controllable shift of the SW frequency. With an integrated design of SW waveguide and microscopic current line for the generation of strong, nanosecond-long, magnetic field pulses, a conversion efficiency up to 39% of the carrier SW frequency is achieved, significantly larger compared to photonic systems. Given the strength of the magnetic field pulses and its strong impact on the SW dispersion relation, the effect of time refraction can be quantified on a length scale comparable to the SW wavelength. Furthermore, we utilize time refraction to excite SW bursts with pulse durations in the nanosecond range and a frequency shift depending on the pulse polarity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resonant four-photon scattering of collinear laser pulses in plasma

Exact four-photon resonance of collinear planar laser pulses is known to be prohibited by the classical dispersion law of electromagnetic waves in plasma. We show here that the renormalization produced by an arbitrarily small relativistic electron nonlinearity removes this prohibition. The laser frequency shifts in collinear resonant four-photon scattering increase with laser intensities. For laser pulses of frequencies much greater than the electron plasma frequency, the shifts can also be much greater than the plasma frequency and even nearly double the input laser frequency at still small relativistic electron nonlinearities. Furthermore, this may enable broad range tunable lasers of very high frequencies and powers. Since the four-photon scattering does not rely on the Langmuir wave, which is very sensitive to plasma homogeneity, such lasers would also be able to operate at much larger plasma inhomogeneities than lasers based on stimulated Raman scattering in plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Microwave Resonant Cavity Transducer Recalibration Procedures

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Inner diameter of the cylindrical cavity is 22.2 mm, and the thin wall is approximately 200µm thick. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Sodium flow rate sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed. From the measurements, we observed significant scatter in high temperature liquid sodium at low flow velocity values. Our hypothesis is that this is caused by temperature drift in the liquid, which results in thermal expansion of the cavity and a drift in the resonator frequency. In this report, we investigate temperature dependence of the resonant frequency through development of analytic models and preliminary analysis of experimental data. In addition, we develop a procedure for compensation for temperature drift during flow sensing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of Zeolitic Imidazolate Framework-8-Functionalized Capacitive Micromachined Ultrasound Transducer Gravimetric Sensors for Gas and Hydrocarbon Vapor Detection

A capacitive micromachined ultrasound transducer (CMUT) was engineered and functionalized with zeolitic imidazolate framework-8 (ZIF-8) dispersed in a photoresist AZ1512HS (AZ) matrix to function as a gravimetric gas sensor. The sensor response was recorded in the presence of nitrogen, argon, carbon dioxide, and methane gases as well as water, acetylene, a propane/butane mixture, n-hexane, gasoline, and diesel vapors. The photoresist matrix alone was found to have a negligible response to all the gases and vapors, except for water vapor. No visible difference in sensor response was detected when switching from nitrogen to methane gas. However, a strong shift in the sensor resonance frequency was observed when exposed to higher hydrocarbons, ranging from 1 kHz for acetylene to 7.5 kHz for gasoline. Even longer-chain hydrocarbons, specifically kerosene and more so diesel, had a significantly reduced sensor frequency shift compared with gasoline. Sensors functionalized with a thin film of AZ+ZIF-8 demonstrated higher sensitivity in their response to a hydrocarbon molecular mass than without functionalization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

BeyondPlanck X. Bandpass and beam leakage corrections

We discuss the treatment of bandpass and beam leakage corrections in the Bayesian BeyondPlanck CMB analysis pipeline as applied to the Planck LFI measurements. As a preparatory step, we first apply three corrections to the nominal LFI bandpass profiles including removal of a known systematic effect in the ground measuring equipment at 61 GHz; smoothing of standing wave ripples; and edge regularization. The main net impact of these modifications is an overall shift in the 70 GHz bandpass of +0.6 GHz; we argue that any analysis of LFI data products, either from Planck or BeyondPlanck, should use these new bandpasses. In addition, we fit a single free bandpass parameter for each radiometer of the form Δ i = Δ 0 + $δ$ i , where Δ 0 represents an absolute frequency shift per frequency band and $δ$i is a relative shift per detector. The absolute correction is only fitted at 30 GHz with a full $\chi$ 2 -based likelihood, resulting in a correction of Δ 30 = 0.24 ± 0.03 GHz. The relative corrections are fitted using a spurious map approach, fundamentally similar to the method pioneered by the WMAP team, but without introducing many additional degrees of freedom. All bandpass parameters are sampled using a standard Metropolis sampler within the main BeyondPlanck Gibbs chain, and bandpass uncertainties are thus propagated to all other data products in the analysis. In total, we find that our bandpass model significantly reduces leakage effects. For beam leakage corrections, we adopt the official Planck LFI beam estimates without additional degrees of freedom, and only marginalize over the underlying sky model. We note that this is the first-time leakage from beam mismatch has been included for Planck LFI maps.

79 ASTRONOMY AND ASTROPHYSICS↗

Significant acceleration of solid-state NMR simulations via three-angle powder averaging

The anisotropic frequency shifts imparted onto the NMR resonance frequency depend on the spherical angular coordinates that describe the orientations of the NMR interaction tensors with respect to the applied magnetic field direction. Experiments performed using magic-angle spinning, however, gain a dependence on a third angle: the rotor phase γ. Traditionally, a carousel average is performed to integrate over γ, which leads to a slow convergence of intensities without contributing to the underlying powder patterns. Herein, we show an order of magnitude acceleration in computation time may be obtained by including the γ-averaging into the main powder average to eliminate redundant calculation of resonance frequencies.

magic-angle spinning↗