Full-Scale Assembly 30 cm Drop Test

Can Spent Nuclear Fuel withstand the shocks and vibrations experienced during normal conditions of transport? This question was the motivation for the multi-modal transportation test (MMTT) (Summer 2017), 1/3-scale cask 30 cm drop test (December 2018), and full-scale assembly 30 cm drop tests (June 2019). The full-scale ENSA ENUN 32P cask with 3 surrogate 17x17 PWR assemblies was used in the MMTT. The 1/3-scale cask was a mockup of this cask. The 30 cm drop tests provided the accelerations on the 1/3-scale dummy assemblies. These data were used to design full-scale assembly drop tests with the goal to quantify the strain fuel rods experience inside a cask when dropped from a height of 30 cm. The drop tests were first done with the dummy and then with the surrogate assembly. This paper presents the preliminary results of the tests.

Transportation↗

Introduction of the PELICAN loop, a Full-Scale Pressure Drop Test Facility

The Versatile Test Reactor (VTR) is a test reactor currently under development by the US Department of Energy. This reactor will rely on fast neutrons enabling novel and wide-ranging experiment to support the development of the various advanced reactor technologies. With the high flux achievable, accelerated testing of fluid and materials will be made possible. To support VTR design efforts [1], an experimental facility has been designed and constructed at Argonne National Laboratory to recreate the hydraulic flow conditions within the VTR’s primary heat transport system (PHTS). This facility, the Pressure drop Experimental Loop for Investigations of Core Assemblies in advanced Nuclear reactors, PELICAN, measures the pressure drop across a full-scale fuel assembly containing prototypic axial reflectors, fuel, and plena components. Here, we first describe the design considerations required to recreate aspects of the VTR. Then we discuss the design and construction of PELICAN to address these design requirements, the design and construction of the test articles placed inside PELICAN’s test section, and finally present some of the first experimental results.

Grannan, A. M.↗

Using Ionic Liquid Additive to Enhance Lubricating Performance for Low-Viscosity Engine Oil

Energy efficient lubricants are essential for sustainable transportation, and the trend is to develop and implement lower viscosity lubricants with more effective additives. Ionic liquids (ILs) have been reported as candidate additives with superior friction and wear reducing capabilities. Unlike most literature relying on bench-scale testing of simple oil–IL blends, this study produced low-viscosity (SAE 0W-12) fully formulated engine oils using a phosphonium-organophosphate IL as an antiwear additive and evaluated them in both bench-scale tribological testing and full-scale fired engine dynamometer testing. The experimental formulation containing a combination of ZDDP and IL outperformed the formulations using either ZDDP or IL alone, as well as a commercial SAE 0W-20 engine oil in terms of mitigating boundary friction, wear, and contact fatigue-induced micropitting. Furthermore, racing engine dynamometer tests demonstrated 3–4 °C lower oil temperature, 4–5 ft-lbs higher horsepower output, and up to 9.9% better fuel economy for the IL-containing SAE 0W-12 experimental oil compared with selected commercial SAE 5W-30 and 0W-20 engine oils.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rates along with the average and maximum qualified stack flow rates for each of the LAB facility stacks. For each stack, the operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10°, except for the LB-C2 Fan A results, which were an average of 13.7°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 4.1% COV, which were all within the range of the target percent coefficient of variation values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAB stacks are 625 to 47,237 scfm for LB-C2, 1,704 to 103,131 scfm for LB-S1, and 467 to 18,088 scfm for LB-S2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10 degrees, except for the LB-C2 Fan A results, which were an average of 17.6 degrees; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 3.5% COV, which were all within the range of the target %COV values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring - Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant low activity waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAW stacks are 815–55,758 scfm for LV-S1, 980–112,078 scfm for LV-S2, 264–22,901 scfm for LV-S3, and 981–79,832 scfm for LV-C2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAW facility. Flow angle results were primarily less than 10°, except for one LV-S2 Fan A result, which was 13.2°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 1.5 COV and 9.2% COV, which were all within the range of the target % COV values from the scale model tests. Based on these stack verification test results, the four LAW filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan operating conditions for LV-S1 and LV-S2, dual-fan operations for LV-S3 at both the continuous air monitor and record sampler locations, and both the single-fan as well as the dual-fan operations for LV-C2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management Facility (EMF) stack monitor location was qualified using a combination of scale model stacks to mitigate the risk of identifying that the sampling location does not meet the qualification criteria on the full-scale stack. The LV-S1 scale model stack was used as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling locations were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. The LV-S1, LB-S1, and LV-S2 scale model stack tests have met the criteria of the ANSI/HPS N13.1-1999 standard to demonstrate the stack sampling locations are well mixed. Verification tests of the EMF stack were performed at normal operating conditions. The minimum 1/6 DV value and the maximum 6 DV value from the scale model testing determine the range of stack flow rates for which the full-scale stack may be operated while remaining in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rate along with the average and maximum qualified stack flow rate based on the LV-S1 scale model DV values. The operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were <5°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, all of which were within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all planned fan operating configurations. This includes each combination of ACV fans with DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A methodology for selection of solid desiccants in energy recovery ventilators

Controlling indoor humidity levels is essential for maintaining acceptable indoor air quality in buildings. The use of energy recovery ventilators (ERVs) is an energy-efficient way to regulate indoor air humidity. Fixed-bed regenerators and rotary wheels are widely used ERVs because of their high sensible and latent effectiveness. These ERVs are made of desiccant-coated substrates, which enable them to transfer moisture between the supply and exhaust air streams. However, the moisture transfer ability of ERVs depends on the physiochemical and sorption properties of desiccants. Extensive, full-scale experiments are required to determine the best desiccant material for these systems. This paper presents a simplified method of selecting suitable desiccant materials for ERVs. The methodology involves important characterization methods, literature correlations for performance prediction, and cost-effective testing methods prior to full-scale testing, and full-scale test methods are discussed in detail. Furthermore, the performance of a few newly derived materials is evaluated and compared with that of conventional desiccants such as silica gel and molecular sieves. The highest latent effectiveness was obtained for composite of super absorbent polymer (SAP) with potassium formate (SAP-HCO2K-50 %), all-polymer porous solid desiccant (APPSD) and metal organic framework (MOF)–MIL–101 (Cr), followed by activated carbon fibre felt (ACFF) Silica sol-LiCl30, SAP, silica gel, MOF–303, and molecular sieve. Researchers and manufacturers would benefit from the proposed methodology and presented data in developing new desiccant materials for ERV applications.

Energy recovery↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management facility (EMF) stack monitor location was qualified using the LV-S1 scale model stack as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale models and its sampling locations were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the EMF stack was performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of stack flow rates for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on the LV-S1 scale model test DV values, the corresponding stack flow rates for the EMF stack are as listed in Table S1. Table S1. Effluent Management Facility Stack Qualified Flow Range. Stack Parameter EM-1 Minimum Qualified Stack Flow (scfm) 781 Maximum Qualified Stack Flow (scfm) 53,432 The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were less than 5°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, which were all within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes each combination of ACV fan with the DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AN ESTIMATE OF SPENT NUCLEAR FUEL MECHANICAL LOADS IN THE GENERAL 30 CM PACKAGE DROP SCENARIO

The US Department of Energy Spent Fuel and Waste Science and Technology (SFWST) program is performing research to determine the mechanical loading conditions applied to spent nuclear fuel (SNF) during normal conditions of transport to inform mechanical tests of SNF and close an important knowledge gap related to the practical disposition of SNF in the US. Researchers at Pacific Northwest National Laboratory (PNNL) have completed an extensive finite element study to characterize and estimate the potential mechanical loads on SNF during a hypothetical 30 cm drop of an SNF transportation package. This modeling study is validated with test data collected by the SFWST program during a physical test campaign that included one-third scale package drop tests and full-scale single fuel assembly drop tests. The test campaign was led by Sandia National Laboratories (SNL) and included international collaboration with Equipos Nucleares S.A, S.M.E (ENSA) and Bundesanstalt für Materialforschung und -prüfung (BAM). The key contribution of the modeling study is to go beyond the limitations of the limited number of physical tests to estimate the impact response to variations in impact angle, initial gap conditions, fuel assembly design, burnup and other parameters that affect the mechanical loads. The methodology of this study included a classic parametric study to calculate the impact response of highly detailed fuel assemblies over many combinations of parameters. Models of a 17x17 pressurized water reactor fuel assembly and a generic 10x10 boiling water reactor fuel assembly were both used in this study to cover the major fuel assembly types in the US inventory. Over 2,000 impact responses were calculated. The results of the parametric study were evaluated using traditional methods and basic statistics. The results were also used to construct a damage model using multiple nonlinear regression techniques to predict the mechanical loads over the full range of all input parameters. The damage model was found to work very well for all impact angle cases where the cask came to rest on its side. It was concluded that end drop cases where the cask remained vertical (instead of tipping over onto its side) were not sufficiently characterized by the current set of parametric study cases to include in the damage model, but it was not a priority to fully investigate that range because the highest mechanical loads were observed in the broader range of side impact cases. This modeling work provides sufficient insight into the mechanical loads on SNF during a hypothetical 30 cm package drop that, when considered along with the physical test data collected by the SNL-led team, the SFSWT program can consider the knowledge gap closed.

Klymyshyn, Nicholas A.↗

Package Performance Study: A Historical Perspective and Planning for a Path Forward

The topic of spent nuclear fuel (SNF) transportation often draws public attention and concerns regarding safety, and with large-scale shipping campaigns expected in the future, public interest is anticipated to substantially increase. In 1999, the U.S. Nuclear Regulatory Commission (NRC) began an initiative called the Package Performance Study (PPS) that initially focused on SNF transportation cask responses to severe transportation accidents. A public participation approach was to be used to help guide the scope and parameters of the study, which was also to consider using full-scale physical testing of a SNF transportation cask, where appropriate. In 2010, the NRC decided not to go forward with physical testing as proposed. In 2006, the National Academy of Sciences (NAS) conducted a study on SNF and high-level radioactive waste transportation in the United States. The NAS study recommended that full-scale cask testing, as well as other accepted methodologies, continue to be used as part of the package performance evaluation. In 2012, the Blue Ribbon Commission on America’s Nuclear Future (BRC) recommended conducting the PPS with a full-scale rail transportation cask for the purpose of building public trust and confidence in the safety of SNF transport. In 2021, the U.S. Department of Energy (DOE) restarted a consent-based siting process, focusing on how to site federal facilities for the interim consolidated storage of SNF using a consent-based approach. Large-scale SNF transportation would be necessary for any such interim storage facility. As the planning activities begin for future large-scale shipping campaigns, the DOE is considering options for conducting a DOE-led PPS to help build public trust and confidence in the transportation of SNF. Therefore, the DOE is gathering information related to the previous NRC-led PPS efforts, as well as applicable international experience with the testing of SNF packages. This paper discusses previous NRC efforts, as well as the current status of a DOE-led PPS, which is in the early planning stages.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design of Modular Test Facility for Particle/sCO2 Heat Exchanger Evaluation

Heliogen has designed a 1.3 MW particle and supercritical carbon dioxide (sCO2) test loop to retire technical and manufacturing risks. The data from this facility will be used to validate near commercial-scale particle heat exchanger modules. The heat exchanger is scaled to capture all features of the full-scale modules. Testing will be conducted with CARBOBEAD HSP 16/30, a larger particle size than other recent testing. The system was designed to ASME codes with the constraint that sCO2 piping and other major components are stainless steels.

14 SOLAR ENERGY↗

Experimental Validation of Exact Burst Pressure Solutions for Thick-Walled Cylindrical Pressure Vessels

Burst pressure is one of the critical strength parameters used in the design and operation of pressure vessels because it represents the maximum pressure that a vessel can withstand before failing. Historically, the Barlow formula was used as a design base for estimating burst pressure. However, it does not consider the plastic flow response for ductile steels and is applicable only to thin-walled cylinders (i.e., the diameter to thickness ratio D/t ≥ 20). A new multiaxial plastic yield theory was developed to consider the plastic flow response, and the associated theoretical (i.e., Zhu–Leis) solution of burst pressure was obtained and has gained extensive applications in the pipeline industry because it was validated by different full-scale burst test datasets for large-diameter, thin-walled pipelines in a variety of steel grades from Grade B to X120. The Zhu–Leis flow theory of plasticity was recently extended to thick-walled pressure vessels, and the associated exact flow solution of burst pressure was obtained and is applicable to both thin and thick-walled cylindrical shells. Many full-scale burst tests are available for thin-walled line pipes in the pipeline industry, but limited pressure burst tests exist for thick-walled vessels. To validate the newly developed exact solutions of burst pressure for thick-walled cylinders, this paper conducts a series of burst pressure tests on small-diameter, thick-walled pipes. In particular, six burst tests are carried out for three thick-walled pipes in Grade B carbon steel. These pipes have a nominal diameter of 2.375 inches (60.33 mm) and three nominal wall thicknesses of 0.154, 0.218, and 0.344 inches (3.91, 5.54, and 8.74 mm), leading to D/t = 15.4, 10.9, and 6.9, respectively. With the burst test data, comparisons show that the Zhu–Leis flow solution of burst pressure matches well the burst test data for thick-walled pipes. Thus, these burst tests validate the accuracy of the Zhu–Leis flow solution of burst pressure for thick-walled cylindrical vessels.

42 ENGINEERING↗

EBS Task Force: Task 9/FEBEX Modeling Final Report: Thermo-Hydrological Modeling with PFLOTRAN

This report outlines Sandia National Laboratories modeling studies applied to Stage 1 and Stage 2 of the Full-scale Engineered Barriers Experiment in Crystalline Host Rock (FEBEX) in situ test for the SKB EBS Task Force Task 9. The FEBEX test was a full-scale test conducted over ~18 years at the Grimsel, Switzerland Underground Research Laboratory (URL) managed by NAGRA. It involved emplacing simulated waste packages, in the form of welded cylindrical heaters, inside a tunnel in crystalline granitic rock and surrounded by a bentonite barrier and cement plug. Sensors emplaced within the bentonite monitored the wetting-up, heating, and drying out of the bentonite barrier, and the large resulting data set provides an excellent opportunity for validation of multiphysics Thermal-Hydrological (TH), Thermal-Hydrologic-Chemical (THC), and Thermal-Hydrological-Mechanical (THM) modeling approaches for underground nuclear waste storage and the performance of engineered bentonite barriers. The present status of the EBS Task Force is finalizing Task 9, which follows years of modeling studies of the FEBEX test, by many notable modeling teams (Gens et al., 2009; Sanchez et al. 2010; 2012; Samper et al., 2018). These modeling studies generally use two-dimensional axisymmetric meshes, ignoring threedimensional effects, gravity and asymmetric wetting and dry out of the bentonite engineered barrier. This study investigates these effects with use of the PFLOTRAN THC code with massively parallel computational methods in modeling FEBEX Stage 1 and Stage 2 results. The PFLOTRAN numerical code is an open source, state-of-the-art, massively parallel subsurface flow and reactive transport code operating in a high-performance computing environment (Hammond et al., 2014). Section 2 describes the applied partial differential equations describing mass, momentum and energy balance used in this study, considerations derived by assuming phase equilibrium between gas and liquid phases, constitutive equations for granite, cement plug, and bentonite domains, and specific approaches for use inthe PFLOTRAN code. Section 3 describes the geometry, meshing, and model set-up. Section 4 describes modeling results, Section 5 compares modeling results to field testing data, and Section 6 gives conclusions. The Appendix provides detailed information required by the EBSTask Force for final reporting.

42 ENGINEERING↗

Design and Implementation of Full-Scale Industrial Control System Test Bed for Assessing Cyber-Security Defenses

In response to the increasing awareness of the Ethernet-based threat surface of industrial control systems (ICS), both the research and commercial communities are responding with ICS-specific security solutions. Unfortunately, many of the properties of ICS environments that contribute to the extent of this threat surface (e.g. age of devices, inability or unwillingness to patch, criticality of the system) similarly prevent the proper testing and evaluation of these security solutions. Production environments are often too fragile to introduce unvetted technology and most organizations lack test environments that are sufficiently consistent with production to yield actionable results. Cost and space requirements prevent the creation of mirrored physical environments leading many to look towards simulation or virtualization. Examples in literature provide various approaches to building ICS test beds, though most of these suffer from a lack of realism due to contrived scenarios, synthetic data and other compromises. In this paper, we provide a design methodology for building highly realistic ICS test beds for validating cybersecurity defenses. We then apply that methodology to the design and building of a specific test bed and describe the results and experimental use cases.

Gillen, Rob↗

Video, photos capture first full-scale H-bomb test 70 years ago

This collection of images was curated by the National Security Research Center in recognition of the 70 th anniversary of the nuclear test codenamed “Mike” of Operation Ivy. The NSRC is the Lab’s classified library, which also houses unclassified artifacts from the Lab’s history. The NSRC has archived photos of nuclear tests from over the years to preserve our history.

99 GENERAL AND MISCELLANEOUS↗