Search NASA⌕ Search

SEARCH · Search NASA

Results for “full width at half maximum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Elucidating the structural properties and reversible regional texture effect of GdB 6 under high pressure

As hard and refractory materials with high chemical resistance and mechanical strength, lanthanide hexaborides (LnB 6 ) have attracted much attention. Among the family of LnB 6 , gadolinium hexaboride (GdB 6 ) occupies a special position due to the half-filled 4f shell of Gd. Here, using in situ synchrotron radiation angle-dispersive X-ray diffraction in a diamond anvil cell at room temperature, the structural stability and compression behavior of GdB 6 are investigated extensively, GdB 6 is observed to be structurally stable up to 73 GPa, and the bulk modulus of 177 GPa is obtained under hydrostatic compression. In this paper, an interesting observation of pressure-induced spotty diffraction rings of GdB6 is reported, its formation mechanism can be well described by the reversible regional texture effect, which highlights the rearrangement of crystal grains under high pressure. The rearrangement mechanism has been well explained by investigating the pressure dependence of full width at half maximum, macro-differential stress and grain size. Collective grain rotation behavior motivated by stress difference is critical for the rearrangement process, the strong isotropy and strong stability of GdB 6 structure also provide necessary conditions for high-pressure grain rotation behavior. These results will help to promote the understanding of high-pressure structural properties of GdB 6 , and provide novel insights on the high-pressure grain behavior in hard materials with strong isotropy and three-dimensional skeleton constituted of strong covalent bonds.

36 MATERIALS SCIENCE↗

Improved lipid analysis using a 2D-LC-MS system with a novel injection procedure

The aim of this study was to improve analysis of nonpolar lipidomics sample extracts using reversed phase (RP) chromatography. A 4/3/3 (v/v/v) mixture of methanol/methyl tert-butyl ether/chloroform (MeOH/MTBE/CHCl 3 , MMC) was chosen for sample extraction solvent based on its proven extraction capability for several lipid classes. To avoid carry over, loss of analytes and peak distortion the loops and all capillaries of the presented LC system were flushed and filled up with methanol until the analytical column. Here, the choice of methanol was due to its weak elution strength and being infinitely miscible with MMC and several other nonpolar solvents. This allowed injection of a 100 μl sample that was 20 μl nonpolar extraction solvent diluted fivefold with methanol. All lipids of 25 lipid classes were transferred quantitatively to the column head where the online dilution of methanol was carried out with aqueous eluent for focusing the lipid analytes. The weak elution strength of methanol prevented peak distortions. The consecutive reversed phase elution resulted in remarkably narrow peaks (full width at half maximum was 0.07–0.08 min typically) and enhanced sensitivity (limit of detection usually in sub nM region) because of increased sample injection volume and narrow peaks. Calibration and quality control samples made by diluting commercial lipid standards 200–50000 times confirmed the applicability of this approach both for targeted lipid quantification and for untargeted quantitative comparison of lipids from different sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlation between microstructure and residual stress formation in friction stir welded armor steels characterized by neutron diffraction

Friction stir welding (FSW) is a solid-state joining process that minimizes the heat-affected zone (HAZ) compared with fusion-based arc welding, making it well suited for joining martensitic armor steels where hardness and ballistic resistance are critical. This study investigates residual stress formation in three defect-free FSW butt-joint configurations relevant to armored-vehicle fabrication: similar rolled homogeneous armor (RHA–RHA, Case 1), similar high-hardness armor (HHA–HHA, Case 2), and dissimilar HHA–RHA (Case 3) joints produced under temperature-controlled conditions (770 °C). Neutron diffraction was employed to quantify the magnitude and spatial distribution of residual stresses in the longitudinal, transverse, and normal directions and to correlate them with weld microstructure and hardness. Tensile residual stresses were concentrated in the softened HAZ, reaching approximately 300 MPa for Case 2 and 400 MPa for Case 1 (≈50–70 % of the base-metal yield strength; ∼581 MPa for RHA and ∼566 MPa for HHA), while compressive residual stresses dominated the stir zone. The spatial extent of tensile stresses scaled with the width of the softened HAZ, which was largest in the dissimilar HHA–RHA joint and smallest in the HHA–HHA joint. Full-width-at-half-maximum (FWHM) analysis revealed low microstrain in overtempered HAZ regions and high microstrain in the stir zone associated with severe plastic deformation and fresh martensite formation. This work demonstrates that residual stress evolution in FSW of martensitic armor steels is governed not primarily by peak temperature or thermal contraction, as inferred from fusion-welding analogies, but by the competition between transformation-induced volumetric expansion and tempering-induced stress relaxation. The relative dominance of these mechanisms is shown to depend on alloy hardenability and local thermal history, leading to more extensive HAZ softening and broader tensile stress regions in the lower-hardenability RHA steel. These findings establish a transferable mechanistic framework for optimizing solid-state joining strategies in high-strength steels and other transformation-hardening alloys beyond armor applications.

Friction stir welding↗

An in-situ study of low thermal expansion and internal stress evolution in FeMn alloys

The mechanism of low thermal expansion phenomenon in antiferromagnetic FeMn alloys needs to be revealed. In this work, the evolution of lattice thermal expansion and internal stress in FeMn alloys was investigated by in-situ synchrotron X-ray diffraction during thermal cycling. Preceding the martensitic transformation, the coefficient of lattice thermal expansion (CLTE) decreased and the full width at half maximum (FWHM) of the diffraction peaks broadened abnormally. The evolution of the lattice thermal expansion and the FWHM were both reversible and isotropic. The additional reflection spots around the fundamental diffraction spots in the electron diffraction patterns of austenite and the dispersed nano-scale martensite embryos in austenite observed in the dark field TEM images proves the existence of premartensitic transformation. Finally, similar phenomena were found in FeMn Invar alloy, which indicate that the Invar effect is closely related to the internal stress evolution caused by premartensitic transformation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multicycle flash sintering of cubic Y 2 O 3 -stabilized ZrO 2 : An in situ energy dispersive synchrotron x-ray diffraction study with high temporal resolution

The current induced unit cell volume changes, (111) Bragg peak full width at half maximum (FWHM) and its integrated intensity in 8 % Y 2 O 3 stabilized ZrO 2 (8 %YSZ) solid state electrolyte was monitored during a triple-flash sintering experiment by in situ energy dispersive x-ray diffraction using a polychromatic synchrotron probe (max, photon energy 200 keV) with 2 second temporal resolution. The first spontaneous singularity in the unit cell volume (+0.54 %) was observed at 899 °C under 15 V/mm applied field intensity, which was associated with 13 mA/mm 2 current draw and an increase in density to 97 %. Following anelastic relaxation of the unit cell volume under open circuit conditions, the same applied field was applied twice in a row which resulted in additional induced singularities at 925 °C (+0.48 %) and 944 °C (+0.42 %). A floating baseline, which was above the thermal expansion baseline, was observed from 833 to 969 °C and was attributed to Joule heating. In conclusion, the singularity at 899 °C is associated with a sharp change in (111) FWHM and a 34 % decrease in integrated peak area that was attributed to changes in the distribution of oxygen vacancies and the changes in their concentration as induced by the applied field in the spontaneous transient stage of flash sintering.

36 MATERIALS SCIENCE↗

Improved plutonium and americium photon branching ratios from microcalorimeter gamma spectroscopy

Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution - (60–70 eV full-width-at-half-maximum at 100 keV) gamma-ray spectra acquired using microcalorimeter sensors to substantially reduce the uncertainties for 11 plutonium ( 238 Pu, 239 Pu, 241 Pu) and 241 Am branching ratios important for material control and accountability and nuclear forensics in the energy range of 125 keV to 208 keV. Lastly, we show a reduction in uncertainty of over a factor of three for one branching ratio and a factor of 2–3 for four branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impulse response measurements of fast scintillator-based current mode detectors

In this study, experimental measurements were performed to characterize the impulse response of seven different gamma ray detector prototypes being considered to be fielded as a current mode diagnostic for neutron-diagnosed subcritical experiments at the Nevada National Security Site (NNSS). For such experiments, the impulse response of the fielded detector is required to have a full-width half-maximum (FWHM) of approximately 5 ns or less and a low amplitude tail. Each of the detector prototypes evaluated in this work were selected based on the potential to meet this performance requirement. An impulse of bremsstrahlung x-rays created from 2 MeV electrons from the NNSS’s Transformational Diagnostics and Imaging, Los Alamos, linear accelerator was measured with each detector. The measured impulse response was evaluated for each detector configuration. A comparison of these impulse responses revealed a relationship between fast timing performance and scintillator material, geometry, surface reflectivity conditions, and photomultiplier tube (PMT) selection. The detector configuration yielding an impulse response with the shortest FWHM of 3.82 ± 0.11 ns and possessing a low amplitude tail was a 5-inch (12.7-cm) diameter, 5-inch (12.7-cm) height cylindrical EJ-399-17-VI liquid scintillator in a black-painted housing coupled to an Adit D798B 5-inch (12.7-cm) PMT by means of a 0.079-inch (0.2-cm) EJ-560 optical coupling pad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of digital electronics for the search of SHE nuclei using GARIS-II/III at RIKEN

This work describes the implementation of a digital data acquisition system for the search and study of short-lived isotopes or superheavy elements at the GARIS-III separator at the RIKEN Nishina Center. Here a reduction to 26 ± 0.5 keV in the average value of the Full Width at Half Maximum of the alpha spectrum at 7.133 MeV was achieved, combined with a reduction of the dead time of the overall system to around a few tens of nanoseconds for the detection of very fast decay chains. Moreover, we measured a reduction of the background induced by particles crossing the implantation detector using pulse shape analysis techniques. The detail of the optimization and analysis will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Algorithms for coordinate reconstruction in position-sensitive virtual Frisch-grid detectors

Arrays of position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors provide a cost-effective solution for integrating large-area arrays for gamma-ray imaging and spectroscopy. These detectors employ high-aspect ratio CZT crystals (bars) with thicknesses up to 50 mm and cross-sections of up to 10 × 10 mm 2 . Despite the long drift distances of charge carriers in such crystals, the detectors have demonstrated excellent performance, achieving energy resolutions better than 1 % full width at half maximum (FWHM) at 662 keV and 3D position resolutions finer than 1 mm. The high spatial resolution is a critical feature of these detectors, as it enables correction of response non-uniformities caused by crystal defects, which remain present even in the highest-quality CZT material. Dislocations and dislocation walls are the primary defects responsible for variations in charge carrier losses as they drift from the interaction points toward the charge-collecting electrodes. The mechanism by which these defects affect carrier transport is generally well understood. Dislocations and sub-grain boundaries act as sinks for carrier-trapping centers, primarily impurities and secondary phases such as tellurium inclusions and precipitates. Here, these regions exhibit significantly higher carrier-trapping rates, leading to variations in the μτ-products. Because the locations of these micron-sized regions are fixed within the detector volume, fluctuations in the total collected charge arise from the random distribution of interaction sites. This results in non-uniform detector responses and degradation of energy resolution. However, by measuring the interaction-site locations with sufficient precision, charge-loss variations can be accurately corrected, allowing recovery of nearly intrinsic energy resolution.

47 OTHER INSTRUMENTATION↗

Impact of light output on the timing resolution of organic glass scintillator bars in a dual-ended readout configuration

The effectiveness of detector system modeling and validation depends on the quality of characterization performed on the system. For nuclear nonproliferation applications, which require detectors to address complex and variable field conditions, access to accurate system models is essential. This study presents the timing characterization of organic glass scintillator bars used in an imaging system developed at the University of Michigan. 137 Cs and 60 Co gamma-ray sources were used to determine the coincidence time resolution as a function of measured light output for two Compton scatter events between two organic glass scintillator bars. Timing resolution for two events, each with light output ranging from 100 to 1100 keVee were characterized. The resulting data were fit to a parametric function that was validated to agree with experimental results within ±25 ps. Simulations were performed to establish appropriate calibration points for each organic scintillator, thereby ensuring accurate calibration of light output values during analysis. This work successfully characterized the light output dependence of the coincidence timing resolution of a pair of organic glass detectors for use in an imaging system. Depending on the amount of scintillation light output from the events, the full width at half maximum of the measured coincidence time resolution ranged from 653.2 ± 16.1 ps for low light yields, 100 keVee, to 121.0 ± 8.4 ps for higher yields at 1100 keVee. The insights obtained from the timing resolution behavior will allow for accurate simulation capabilities in future security and verification efforts using scatter-based imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electric current-induced precipitation hardening in advanced high-strength steel

Effect of electric current on precipitation hardening for advanced high-strength steel is investigated based on mechanical testing and microscopic observation. Complex-phase steel containing nano-sized Nb-bearing carbides was used. By comparing the flow stress between uniaxial tension with applied electric current (pulsed tension) and without electric current (nonpulsed tension) at various elevated temperatures, the influence of electric current on precipitation hardening was confirmed. A higher values of Vickers hardness and full-width-at-half-maximum were obtained in the pulsed tensile specimen compared to the identically heat treated specimen after the same deformation. Small angle neutron scattering analysis showed that the volume fraction and mean diameter of newly formed precipitates in the pulsed tensile specimen were higher and larger than those in the induction heat treated specimen, respectively. In conclusion, it clearly shows that additional precipitation hardening could be induced by the athermal effect of electric current, which is distinct from the thermal effect of Joule heating.

36 MATERIALS SCIENCE↗

Vibrational spectroscopy of uranium tetrafluoride hydrates

Uranium tetrafluoride (UF 4 ) is an important intermediate in the production of UF6 and nuclear fuel. Historical characterization of UF 4 with Raman spectroscopy was plagued with ambiguity until the first accurate Raman spectrum was published by our group in 2016. Although generally considered to be relatively stable, UF 4 can hydrolyze to form numerous UF 4 hydrates that may play a role in future uranium waste forms. In contrast to anhydrous UF 4 , the hydrates, with their OH stretch and HOH bending modes, can be spectroscopically characterized by the type and degree of water bonding in the crystal lattice, which can yield additional information about their crystal structure. Herein, vibrational spectroscopy (Raman and infrared) was used to characterize three different UF 4 hydrates: UF 4 (H 2 O) 0.33 , U 3 F 12 (H 2 O), and UF 4 (H 2 O) 2.5 . Spectra show the different hydrates vary in the number of observed bands, full-width half-maximum of the bands, and band intensity. These differences are due to varying interactions between the OH stretch and HOH bending modes with UF 4 and the polymeric UF 4 structure in the crystal lattice. These vibrational data, in combination with spectral fitting and crystallographic structures measured with powder X-ray diffraction and single crystal X-ray diffraction, provide unique details on the location of water molecules in the crystal lattice of hydrated UF 4 , and provide an interesting contrast to the vibrational spectra of anhydrous UF 4 .

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

One Pot Synthesis of Cyan Emitting CdZnSSe Quantum Dots for Human Centric Lighting

A one pot synthesis of blue and green emissive CdZnSSe quantum dots (QDs) from thio- and selenoureas and Cd and Zn carboxylates is optimized using high throughput robotic optimization. A large set of spectral data (N = 192) is used to train machine learning models that accurately predict the photoluminescence emission wavelength (λmax) and full-width half-maximum, and the relative photoluminescence quantum yield (PLQY) from the S:Se and Zn:Cd stoichiometries and reaction time. ZnS shells are deposited on the crude QD heterostructures using 4-tert-butylbenzyl mercaptan, a more reactive source of sulfide that enables shell growth below the temperature where ion diffusion in the QD can broaden its optical spectrum (≤275 °C). These optimized procedures provide gram quantities of blue-green emitting QDs (PLQY = 85–99%) in a single reaction vessel. A solid state lighting device (4260 K) that incorporates cyan emissive QDs achieved a higher luminous efficacy of 179 lm/W and melanopic daylight efficiency ratio (0.71) than existing commercial human centric lighting devices.

Jordan, Abraham J↗

Supramolecular assembly of molecular wires alternating crown ethers and metal–halide complexes

Metal–halide complexes serve as key emissive centres in halide perovskites; however, precise control over their spatial organization through bottom-up assembly is challenging. Here we show that a crown-ether-assisted supramolecular assembly strategy can alternatingly connect metal–halide complexes and (crown ether@A) 2+ (where ‘A’ is an alkaline earth metal cation) complexes into a one-dimensional molecular wire, which can then be packed into a hexagonal crystal structure. This process resulted in the creation of an (18C6@Ba)MnBr 4 single crystal with green emission, achieving over 80% photoluminescence quantum yield and a narrow full width at half maximum. In addition, the non-centrosymmetric crystal structure gave rise to strong nonlinear optical responses, including second-harmonic generation. This versatile supramolecular assembly approach could be generalized to create various [M(I)X 2 ] − , [M(I)X 3 ] 2− , [M(II)X 4 ] 2− and [M(III)X 5 ] 2− molecular wires, broadening the potential for diverse emission colours and distinct optical properties. This strategy provides a general design principle for constructing supramolecular metal–halide building blocks with diverse optical functionalities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diffraction data from aerosolized Coliphage PR772 virus particles imaged with the Linac Coherent Light Source

Single Particle Imaging (SPI) with intense coherent X-ray pulses from X-ray free-electron lasers (XFELs) has the potential to produce molecular structures without the need for crystallization or freezing. Here we present a dataset of 285,944 diffraction patterns from aerosolized Coliphage PR772 virus particles injected into the femtosecond X-ray pulses of the Linac Coherent Light Source (LCLS). Additional exposures with background information are also deposited. The diffraction data were collected at the Atomic, Molecular and Optical Science Instrument (AMO) of the LCLS in 4 experimental beam times during a period of four years. The photon energy was either 1.2 or 1.7 keV and the pulse energy was between 2 and 4 mJ in a focal spot of about 1.3 μm x 1.7 μm full width at half maximum (FWHM). The X-ray laser pulses captured the particles in random orientations. The data offer insight into aerosolised virus particles in the gas phase, contain information relevant to improving experimental parameters, and provide a basis for developing algorithms for image analysis and reconstruction.

59 BASIC BIOLOGICAL SCIENCES↗

Deterministic fabrication of highly reproducible monochromatic quantum emitters in hexagonal boron nitride

Quantum emitters in hexagonal boron nitride are important room temperature single-photon sources. However, conventional fabrication methods yield quantum emitters with dispersed and inconsistent spectral profiles, limiting their potential for practical quantum applications, which demand reproducible high quality single-photon sources. Here, we report the deterministic creation of highly reproducible monochromatic quantum emitters by applying carbon-ion implantation on freestanding hexagonal boron nitride flakes, while a carbon mask with suitable thickness was adapted to optimize the implantation results. Quantum emitters fabricated using this approach exhibited thermally limited monochromaticity, with an emission center wavelength of 590.7 ± 2.7 nm, a narrow full width at half maximum of 7.1 ± 1.7 nm, an emission rate of 1 MHz without optical engineering, and exceptional stability under ambient conditions. Density functional theory calculations and scanning transmission electron microscopy suggest that these emitters are comprised of boron centered carbon tetramers. This method provides a reliable single-photon source for optical quantum computing and potential future industry-scale applications.

Hua, Muchuan [Argonne National Laboratory (ANL), A↗

Anomalies in the topology of the temperature fluctuations in the cosmic microwave background: An analysis of the NPIPE and FFP10 data releases

We present a topological analysis of the temperature fluctuation maps from the Planck 2020 Data Release 4 NPIPE dataset and the Planck 2018 Data Release 3 FFP10 dataset. We performed a multiscale analysis in terms of the homology characteristics of the maps, invoking relative homology to account for the analysis in the presence of masks. We performed our analysis for a range of smoothing scales spanning sub- and super-horizon scales corresponding to a full width at half maximum (FWHM) of 5',10',20',40',80',160',320', and 640', and employed simulations based on the standard model for comparison, which assumes the initial fluctuation field to be an isotropic and homogeneous Gaussian random field. Examining the behavior of topological components, represented by the 0D homology group, we find the observations to be approximately 2σ or less deviant from the simulations for all resolutions and scales for the NPIPE dataset. For the FFP10 dataset, we detect a 2.96σ deviation between the observations and simulations at N = 128, FWHM = 80'. For the topological loops, represented by the first homology group, the simulations and observations are consistent within 2σ for most resolutions and scales for both the datasets. However, for the NPIPE dataset, we observe a high deviation between the observation and simulations in the number of loops at FWHM = 320', but at a low dimensionless threshold ν = –2.5. Under a Gaussian assumption, this would amount to a deviation of ~4σ. However, the distribution in this bin is manifestly non-Gaussian and does not obey Poisson statistics either. In the absence of a true theoretical understanding, we simply note that the significance is higher than what may be resolved by 600 simulations, yielding an empirical p-value of at most 0.0016. Specifically in this case, our tests indicate that the numbers arise from a statistically stable regime, despite being based on small numbers. For the FFP10 dataset, the differences are not as strong as for the NPIPE dataset, indicating a 2.77σ deviation at this resolution and threshold. The Euler characteristic, which is the alternating sum of the ranks of relative homology groups, reflects the deviations in the components and loops. To assess the significance of combined levels for a given scale, we employed the empirical and theoretical versions of the χ 2 test as well as the nonparametric Tukey depth test. Although all statistics exhibit a stable distribution, we favor the empirical version of the χ 2 test in the final interpretation, as it indicates the most conservative differences. For the NPIPE dataset, we find that the components and loops differ at more than 95%, but agree within the 99% confidence level with respect to the base model at N = 32, FWHM = 320'. The Euler characteristic at this resolution displays a per mil deviation. In contrast, the FFP10 dataset shows that the observations are consistent with the base model within the 95% confidence level, at this and smaller scales. This is consistent with the observations of the Planck analysis pipeline via Minkowski functionals. For the largest smoothing scale, N = 16, FWHM = 640', both datasets exhibit an anomalous behavior of the loops, where FFP10 data exhibit a deviation that is larger by an order of magnitude than that of the NPIPE dataset. In contrast, the values for the topological components and the Euler characteristic agree between observations and model to within a confidence level of 99%. However, for the largest scales, the statistics are based on low numbers and may have to be regarded with caution. Even though both datasets exhibit mild to significant discrepancies, they also exhibit contrasting behaviors at various instances. Therefore, we do not find it feasible to convincingly accept or reject the null hypothesis. Disregarding the large-scale anomalies that persist at similar scales in WMAP and Planck, observations of the cosmic microwave background are largely consistent with the standard cosmological model within 2σ.

79 ASTRONOMY AND ASTROPHYSICS↗

Delving into the depths of NGC 3783 with XRISM

Using XRISM/Resolve 439 ks time-averaged spectra of the well-known Seyfert-1.5 active galactic nucleus (AGN) in NGC 3783, we investigated the nature of the Fe Kα emission line at 6.4 keV, the strongest and most common X-ray line observed in AGNs. Even the narrow component of the line is resolved with evident Fe Kα 1 (6.404 keV) and Kα 2 (6.391 keV) contributions with a 2:1 flux ratio, fully consistent with a neutral gas with negligible bulk velocity. The narrow and intermediate-width components have a full width at half maximum of 350 ± 50 km/s and 3510 ± 470 km/s, respectively, suggesting that they arise in the outer disk/torus and/or broad line region. We detect a 10% excess flux around 4–7 keV that is not described well by a symmetric Gaussian line but is consistent with a relativistically broadened emission line. In this study we took the simplest approach, modelling the asymmetric line as a single emission line (assuming neutral, He-like, or H-like iron) convolved with a relativistic disk line model. As expected, the inferred inclination angle (i) is highly sensitive to the assumed ionisation state and ranges between 17 and 44°. This model also constrains the black hole spin via the extent of the red wing: the required gravitational redshift in the fitted disk-line profile disfavours a non-spinning (Schwarzschild) black hole. The derived inner radius is close to the radius of the innermost stable circular orbit (rISCO) and is strongly correlated with the black hole spin. To better constrain the spin, we fixed the inner radius to r ISCO and derived a lower limit on the spin of a ≥ 0.29 at the 3σ confidence level. A Compton shoulder is detected in our data as well as a 2–3σ detection of the Cr Kα and Ni Kα lines.

Astronomy and AstroPhysics↗