Search NASA⌕ Search

SEARCH · Search NASA

Results for “gamma correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Studies of a Proton Bunch Phase Monitor for Range Verification in Proton Therapy

A primary subject of the present research in particle therapy is to ensure the precise irradiation of the target volume. The prompt gamma timing (PGT) method provides one possibility for in vivo range verification during the irradiation of patients. Prompt gamma rays with high energies are emitted promptly due to nuclear reactions of protons with tissue. The arrival time of these gammas to the detector reflects the stopping process of the primary protons in tissue and is directly correlated to the range. Due to the time resolution of the detector and the proton bunch time spread, as well as drifts of the bunch phase with respect to the accelerator frequency, timing spectra are smeared out and compromise the accuracy of range information intended for future clinical applications. Nevertheless, counteracting this limitation and recovering range information from the PGT measured spectra, corrections using a bunch phase monitor can be performed. A first prototype of bunch phase monitor was tested at GSI Darmstadt, where measurements of the energy correlation profile of the ion bunches were performed. At the ELBE accelerator at Helmholtz-Zentrum Dresden-Rossendorf (HZDR), set up to provide bremsstrahlung photons in very short pulses, a constant fraction algorithm for the incoming digital signals was evaluated, which is used for optimizing the time resolution. Studies of scattering experiments with different thin targets and detector positions are accomplished at Onco Ray Dresden, where a clinical proton beam is available. These experiments allow a basic characterization of the proton bunch structure and the detection yield. (authors)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of High Count Rate and Gain Shift on Isotope Identification Algorithms

Spectroscopic gamma-ray detectors are used for many research applications, as well as Homeland Security screening applications. Sodium iodide (NaI) scintillator crystals coupled with photomultiplier tubes (PMTs) provide medium-resolution spectral data about the surrounding environment. NaI based detectors, paired with spectral identification algorithms, are often effective in identifying sources of interest by isotope. However, intrinsic limitations exist for NaI systems because of gain shifts and spectral marring (e.g., loss of resolution and count-rate saturation) at high count rates. These effects are hardware dependent, and have strong effects on the radioisotopic identification capability of these systems. In this work, the effects of high count rate on the capability of isotope identification algorithms are explored. It is shown that a small gain shift of a few tens of keV is sufficient to disturb identification. The onset of this and other spectral effects are estimated for several systems., and a mechanism for mitigating these effects by estimating and correcting for them is implemented and evaluated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Spatially Extended Fermi-LAT Sources Using Two Years of Data

Spatial extension is an important characteristic for correctly associating {gamma}-ray-emitting sources with their counterparts at other wavelengths and for obtaining an unbiased model of their spectra. We present a new method for quantifying the spatial extension of sources detected by the Large Area Telescope (LAT), the primary science instrument on the Fermi Gamma-ray Space Telescope (Fermi). We perform a series of Monte Carlo simulations to validate this tool and calculate the LAT threshold for detecting the spatial extension of sources. We then test all sources in the second Fermi -LAT catalog (2FGL) for extension. We report the detection of seven new spatially extended sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reexamining the role of the ( n , γ f ) process in the low-energy fission of U 235 and Pu 239

In this paper, the $(n,{\gamma}f)$ process is reviewed in light of modern nuclear reaction calculations in both slow and fast neutron-induced fission reactions on $^{235}\mathrm{U}$ and $^{239}\mathrm{Pu}$. Observed fluctuations of the average prompt fission neutron multiplicity and average total ${\gamma}$-ray energy below 100-eV incident neutron energy are interpreted in this framework. The surprisingly large contribution of the $M1$ transitions to the prefission ${\gamma}$-ray spectrum of $^{239}\mathrm{Pu}$ is explained by the dominant fission probabilities of ${0}^{+}$ and ${2}^{+}$ transition states, which can only be accessed from compound nucleus states formed by the interaction of $s$-wave neutrons with the target nucleus in its ground state, and decaying through $M1$ transitions. The impact of an additional low-lying $M1$ scissors mode in the photon strength function is analyzed. We review experimental evidence for fission fragment mass and kinetic-energy fluctuations in the resonance region and their importance in the interpretation of experimental data on prompt neutron data in this region. In conclusion, calculations are extended to the fast energy range where $(n,{\gamma}f)$ corrections can account for up to 3% of the total fission cross section and about 20% of the capture cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

N* Resonances and Duality in Deep-Inelastic Scattering

The role of N* resonances will be discussed in the context of quark-hadron duality for inclusive electron-hadron scattering. A review of recent experimental test of duality using data from Jefferson Lab will be given, and prospects for relating N* resonance parameters to inclusive and semi-inclusive scaling cross sections explored. The importance of the resonance region in parity-violating electron scattering will also be discussed in connection with \gamma-Z corrections to the weak charge of the proton.

Melnitchouk, Wolodymyr↗

Cross Sections for Neutron-induced Reactions on Actinide Targets Extracted from Surrogate Experiments: A Status Report

The Surrogate nuclear reactions method, an indirect approach for determining cross sections for compound-nuclear reactions involving difficult-to-measure targets, is reviewed. Focusing on cross sections for neutron-induced reactions on actinides, we review the successes of past and present applications of the method and assess its uncertainties and limitations. The approximations used in the analyses of most experiments work reasonably well for (n,f) cross sections for neutron energies above 1-2 MeV, but lead to discrepancies for low-energy (n,f) reactions, as well as for (n,{gamma}) applications. Correcting for some of the effects neglected in the approximate analyses leads to improved (n,f) results. We outline steps that will further improve the accuracy and reliability of the Surrogate method and extend its applicability to reactions that cannot be approached with the present implementation of the method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Intensity moments by path integral techniques for wave propagation through random media, with application to sound in the ocean

A theory is developed which describes intensity moments for wave propagation through random media. It is shown using the path integral technique that these moments are significantly different from those of a Rayleigh distribution in certain asymptotic regions. The path integral approach is extended to inhomogeneous, anisotropic media possessing a strong deterministic velocity profile. The behavior of the corrections to Rayleigh statistics is examined, and it is shown that the important characteristics can be attributed to a local micropath focusing function. The correction factor gamma is a micropath focusing parameter defined in terms of medium fluctuations. The value of gamma is calculated for three ocean acoustic experiments, using internal waves as the medium fluctuations. It is found that all three experiments show excellent agreement as to the relative values of the intensity moments. The full curved ray is found to yield results that are significantly different from the straight-line approximations. It is noted that these methods are applicable to a variety of experimental situations, including atmospheric optics and radio waves through plasmas.

Bernstein, D. R.↗

Computation of large-scale statistics in decaying isotropic turbulence

We have performed large-eddy simulations of decaying isotropic turbulence to test the prediction of self-similar decay of the energy spectrum and to compute the decay exponents of the kinetic energy. In general, good agreement between the simulation results and the assumption of self-similarity were obtained. However, the statistics of the simulations were insufficient to compute the value of gamma which corrects the decay exponent when the spectrum follows a k(exp 4) wave number behavior near k = 0. To obtain good statistics, it was found necessary to average over a large ensemble of turbulent flows.

Chasnov, Jeffrey R.↗

A Jet Break in the X-ray Light Curve of Short GRB 111020A: Implications for Energetics and Rates

We present broadband observations of the afterglow and environment of the short GRB 111020A. An extensive X-ray light curve from Swift/XRT, XMM-Newton, and Chandra, spanning approx.100 s to 10 days after the burst, reveals a significant break at (delta)t approx. = 2 days with pre- and post-break decline rates of (alpha)X,1 approx. = -0.78 and (alpha)X,2 < or approx. 1.7, respectively. Interpreted as a jet break, we infer a collimated outflow with an opening angle of (theta)j approx. = 3deg - 8deg. The resulting beaming-corrected gamma-ray (10-1000 keV band) and blast-wave kinetic energies are (2-3) x 10(exp 48) erg and (0.3-2) x 10(exp 49) erg, respectively, with the range depending on the unknown redshift of the burst. We report a radio afterglow limit of <39 micro-Jy (3(sigma)) from Expanded Very Large Array observations that, along with our finding that v(sub c) < v(sub X), constrains the circumburst density to n(sub 0) approx.0.01 0.1/cu cm. Optical observations provide an afterglow limit of i > or approx.24.4 mag at 18 hr after the burst and reveal a potential host galaxy with i approx. = 24.3 mag. The subarcsecond localization from Chandra provides a precise offset of 0".80+/-0".11 (1(sigma))from this galaxy corresponding to an offset of 5.7 kpc for z = 0.5-1.5. We find a high excess neutral hydrogen column density of (7.5+/-2.0) x 10(exp 21)/sq cm (z = 0). Our observations demonstrate that a growing fraction of short gamma-ray bursts (GRBs) are collimated, which may lead to a true event rate of > or approx.100-1000 Gpc(sup -3)/yr, in good agreement with the NS-NS merger rate of approx. = 200-3000 Gpc(sup -3)/ yr. This consistency is promising for coincident short GRB-gravitational wave searches in the forthcoming era of Advanced LIGO/VIRGO.

Fong, W.↗

Psychophysical Calibration of Mobile Touch-Screens for Vision Testing in the Field

The now ubiquitous nature of touch-screen displays in cell phones and tablet computers makes them an attractive option for vision testing outside of the laboratory or clinic. Accurate measurement of parameters such as contrast sensitivity, however, requires precise control of absolute and relative screen luminances. The nonlinearity of the display response (gamma) can be measured or checked using a minimum motion technique similar to that developed by Anstis and Cavanagh (1983) for the determination of isoluminance. While the relative luminances of the color primaries vary between subjects (due to factors such as individual differences in pre-retinal pigment densities), the gamma nonlinearity can be checked in the lab using a photometer. Here we compare results obtained using the psychophysical method with physical measurements for a number of different devices. In addition, we present a novel physical method using the device's built-in front-facing camera in conjunction with a mirror to jointly calibrate the camera and display. A high degree of consistency between devices is found, but some departures from ideal performance are observed. In spite of this, the effects of calibration errors and display artifacts on estimates of contrast sensitivity are found to be small.

gamma correction↗

Generation of Precision Stimuli for Web-based and At-home Psychophysics

This oral presentation will present methods for “linearizing” a display to enable the delivery of precisely controlled stimuli in vision experiments, performing colorimetric calibrations using common objects, and testing for spatial and temporal nonlinearities.

visual display calibration↗

Properties of the decay ${{H\to\gamma\gamma}} $ using the approximate ${{\alpha_s^4}}$ corrections and the principle of maximum conformality

The decay channel $ H\to\gamma\gamma $ is an important channel for probing the properties of the Higgs boson. In this paper, we analyze its decay width by using the perturbative QCD corrections up to the $ \alpha_s^4 $ order with the help of the principle of maximum conformality (PMC). PMC has been suggested in literature for eliminating the conventional renormalization scheme-and-scale ambiguities. After applying PMC, we observe that an accurate renormalization scale independent decay width $ \Gamma(H\to\gamma\gamma) $ up to the N 4 LO level can be achieved. Taking the Higgs mass, $ M_{\rm H} = 125.09\pm $ $ 0.21\pm0.11 $ GeV, given by the ATLAS and CMS collaborations, we obtain $ \Gamma(H\to \gamma\gamma)|_{\rm LHC} = 9.364^{+0.076}_{-0.075} $ KeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precise predictions for (nonstandard) W{gamma}+ jet production

We report on a detailed investigation of the next-to-leading-order QCD corrections to W{gamma}+jet production at the Tevatron and the LHC using a fully flexible parton-level Monte Carlo program. We include the full leptonic decay of the W, taking into account all off-shell and finite width effects, as well as nonstandard WW{gamma} couplings. We find particularly sizable corrections for the currently allowed parameter range of anomalous couplings imposed by LEP data. In total, the next-to-leading-order differential distributions reveal a substantial phase-space dependence of the corrections, leaving considerable sensitivity to anomalous couplings beyond scale uncertainty at large momentum transfers in the anomalous vertex.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-C-201-06: Small Field Correction Factors for the MicroDiamond Detector in the Gamma Knife-Model C Derived Using Monte Carlo Methods

Purpose: To determine small field correction factors for PTW’s microDiamond detector in Elekta’s Gamma Knife Model-C unit. These factors allow the microDiamond to be used in QA measurements of output factors in the Gamma Knife Model-C; additionally, the results also contribute to the discussion on the water equivalence of the relatively-new microDiamond detector and its overall effectiveness in small field applications. Methods: The small field correction factors were calculated as k correction factors according to the Alfonso formalism. An MC model of the Gamma Knife and microDiamond was built with the EGSnrc code system, using BEAMnrc and DOSRZnrc user codes. Validation of the model was accomplished by simulating field output factors and measurement ratios for an available ABS plastic phantom and then comparing simulated results to film measurements, detector measurements, and treatment planning system (TPS) data. Once validated, the final k factors were determined by applying the model to a more waterlike solid water phantom. Results: During validation, all MC methods agreed with experiment within the stated uncertainties: MC determined field output factors agreed within 0.6% of the TPS and 1.4% of film; and MC simulated measurement ratios matched physically measured ratios within 1%. The final k correction factors for the PTW microDiamond in the solid water phantom approached unity to within 0.4%±1.7% for all the helmet sizes except the 4 mm; the 4 mm helmet size over-responded by 3.2%±1.7%, resulting in a k factor of 0.969. Conclusion: Similar to what has been found in the Gamma Knife Perfexion, the PTW microDiamond requires little to no corrections except for the smallest 4 mm field. The over-response can be corrected via the Alfonso formalism using the correction factors determined in this work. Using the MC calculated correction factors, the PTW microDiamond detector is an effective dosimeter in all available helmet sizes. The authors would like to thank PTW (Friedberg, Germany) for providing the PTW microDiamond detector for this research.

07 ISOTOPE AND RADIATION SOURCES↗

QCD corrections to associated production of tt{gamma} at hadron colliders

We report on the next-to-leading order (NLO) QCD computation of top-quark pair production in association with a photon at the Fermilab Tevatron RUN II and CERN Large Hadron Collider. We describe the impact of the complete NLO QCD radiative corrections to this process, and provide the predictions of the leading order (LO) and NLO integrated cross sections, distributions of the transverse momenta of the top quark and photon for the LHC and Tevatron, and the LO and NLO forward-backward top-quark charge asymmetries for the Tevatron. We investigate the dependence of the LO and NLO cross sections on the renormalization/factorization scale, and find the scale dependence of the LO cross section is obviously improved by the NLO QCD corrections. The K-factor of the NLO QCD correction is 0.977(1.524) for the Tevatron (LHC)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗