Search NASA⌕ Search

SEARCH · Search NASA

Results for “geometry factor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Temperature-dependent structural studies of mullite-type Bi{sub 2}Fe{sub 4}O{sub 9}

We report on the temperature-dependent structural studies on the mullite-type Bi{sub 2}Fe{sub 4}O{sub 9} compound. The crystal structures were determined using both powder X-ray diffraction and single crystal neutron diffraction. The thermal expansion of the cell parameters from smallest to largest occurred in the order a<c<b; their expansion behavior was fit using either linear or nonlinear regression according to the region of choice. The anisotropic thermal expansion was monitored with respect to the expansion coefficients, anisotropy factor, and polyhedral geometry. At 900 K an abrupt change of the anisotropy factor is observed which correlates with a slope in the BiO{sub 6} polyhedral volume. At the same temperature the FeO{sub 4} tetrahedral distortion starts to increase. The temperature-dependent stereochemically activity of the Bi{sup 3+} 6s{sup 2} lone electron pair was probed by the absolute value of eccentricity parameter. This parameter shows a significant drop at around 773 K. Additionally, the average crystal size and micro-strain of the powder samples were studied. A healing of intrinsic defects is observed with respect to a decreasing micro-strain followed by crystal growth above about 900 K. The temperature-dependent infrared spectra were described in three distinct zones. Deconvolution of the absorption features between 370 cm{sup -1} and 1000 cm{sup -1} required nine fitted bands, and the decomposed Pseudo-Voigt elements were assigned to Fe-O stretching, Fe-O-Fe bending and O-Fe-O bending vibrations. The shift of the observed modes was described with respect to temperature. An effective linewidth parameter {Delta}corr was determined by autocorrelation analysis between 740 cm{sup -1} and 900 cm{sup -1} for each temperature-dependent spectrum. The break of the slope of {Delta}corr at about 773 K was interpreted as the change of some vibrational modes of the FeO{sub 4} tetrahedra. The intrinsic effects observed around 773 K are responsible for extrinsic parameter changes found around 900 K. - Graphical abstract: Temperature-dependent stereochemical activity (eccentricity |{Phi}{sub i}|) of the Bi{sup 3+} 6s{sup 2} lone electron pair directing in the non-bonded region of the Bi-O coordination in the Bi{sub 2}Fe{sub 4}O{sub 9} iron framework (given as polyhedra). Highlights: Black-Right-Pointing-Pointer Complex expansion-contraction mechanism explains anisotropic thermal expansion. Black-Right-Pointing-Pointer Bi 6s{sup 2} lone electron pair sphericity influences analyses by FTIR autocorrelation. Black-Right-Pointing-Pointer Intrinsic effects at 773 K are responsible for extrinsic parameter changes at 900 K.

36 MATERIALS SCIENCE↗

Shielding properties of lead-free protective clothing and their impact on radiation doses

The shielding properties of two different lead-free materials--tin and a compound of 80% tin and 20% bismuth--for protective clothing are compared with those of lead for three typical x-ray spectra generated at tube voltages of 60, 75, and 120 kV. Three different quantities were used to compare the shielding capability of the different materials: (1) Air-kerma attenuation factors in narrow-beam geometry, (2) air-kerma attenuation factors in broad-beam geometry, and (3) ratios of organ and effective doses in the human body for a whole-body irradiation with a parallel beam directed frontally at the body. The thicknesses of tin (0.45 mm) and the tin/bismuth compound (0.41 mm) to be compared against lead correspond to a lead equivalence value of 0.35 mm for the 75 kV spectrum. The narrow-beam attenuation factors for 0.45 mm tin are 54% and 32% lower than those for 0.35 mm lead for 60 and 120 kV; those for 0.41 mm tin/bismuth are 12% and 32% lower, respectively. The decrease of the broad-beam air-kerma attenuation factors compared to lead is 74%, 46%, and 41% for tin and 42%, 26%, and 33% for tin/bismuth and the spectra at 60, 75, and 120 kV, respectively. Therefore, it is recommended that the characterization of the shielding potential of a material should be done by measurements in broad-beam geometry. Since the secondary radiation that is mainly responsible for the shielding reduction in broad-beam geometry is of low penetrability, only more superficially located organs receive significantly enhanced doses. The increase for the dose to the glandular breast tissue (female) compared to being shielded by lead is 143%, 37%, and 45% when shielded by tin, and 35%, 15%, and 39% when shielded by tin/bismuth for 60, 75, and 120 kV, respectively. The effective dose rises by 60%, 6%, and 38% for tin, and 14%, 3% and, 35% for tin/bismuth shielding, respectively.

61 RADIATION PROTECTION AND DOSIMETRY↗

Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging

Purpose: This work applies a cascaded systems model for cone-beam CT imaging performance to the design and optimization of a system for musculoskeletal extremity imaging. The model provides a quantitative guide to the selection of system geometry, source and detector components, acquisition techniques, and reconstruction parameters. Methods: The model is based on cascaded systems analysis of the 3D noise-power spectrum (NPS) and noise-equivalent quanta (NEQ) combined with factors of system geometry (magnification, focal spot size, and scatter-to-primary ratio) and anatomical background clutter. The model was extended to task-based analysis of detectability index (d') for tasks ranging in contrast and frequency content, and d' was computed as a function of system magnification, detector pixel size, focal spot size, kVp, dose, electronic noise, voxel size, and reconstruction filter to examine trade-offs and optima among such factors in multivariate analysis. The model was tested quantitatively versus the measured NPS and qualitatively in cadaver images as a function of kVp, dose, pixel size, and reconstruction filter under conditions corresponding to the proposed scanner. Results: The analysis quantified trade-offs among factors of spatial resolution, noise, and dose. System magnification (M) was a critical design parameter with strong effect on spatial resolution, dose, and x-ray scatter, and a fairly robust optimum was identified at M {approx} 1.3 for the imaging tasks considered. The results suggested kVp selection in the range of {approx}65-90 kVp, the lower end (65 kVp) maximizing subject contrast and the upper end maximizing NEQ (90 kVp). The analysis quantified fairly intuitive results--e.g., {approx}0.1-0.2 mm pixel size (and a sharp reconstruction filter) optimal for high-frequency tasks (bone detail) compared to {approx}0.4 mm pixel size (and a smooth reconstruction filter) for low-frequency (soft-tissue) tasks. This result suggests a specific protocol for 1 x 1 (full-resolution) projection data acquisition followed by full-resolution reconstruction with a sharp filter for high-frequency tasks along with 2 x 2 binning reconstruction with a smooth filter for low-frequency tasks. The analysis guided selection of specific source and detector components implemented on the proposed scanner. The analysis also quantified the potential benefits and points of diminishing return in focal spot size, reduced electronic noise, finer detector pixels, and low-dose limits of detectability. Theoretical results agreed quantitatively with the measured NPS and qualitatively with evaluation of cadaver images by a musculoskeletal radiologist. Conclusions: A fairly comprehensive model for 3D imaging performance in cone-beam CT combines factors of quantum noise, system geometry, anatomical background, and imaging task. The analysis provided a valuable, quantitative guide to design, optimization, and technique selection for a musculoskeletal extremities imaging system under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-gluon correlations in heavy–light ion collisions: Energy and geometry dependence, IR divergences, and k T -factorization

Here, we study the properties of the cross section for two-gluon production in heavy–light ion collisions derived in our previous paper in the saturation/Color Glass Condensate framework. Concentrating on the energy and geometry dependence of the corresponding correlation functions we find that the two-gluon correlator is a much slower function of the center-of-mass energy than the one- and two-gluon production cross sections. The geometry dependence of the correlation function leads to stronger azimuthal near- and away-side correlations in the tip-on-tip U + U collisions than in the side-on-side U + U collisions, an exactly opposite behavior from the correlations generated by the elliptic flow of the quark–gluon plasma: a study of azimuthal correlations in the U + U collisions may thus help to disentangle the two sources of correlations. We demonstrate that the cross section for two-gluon production in heavy–light ion collisions contains a power-law infrared (IR) divergence even for fixed produced gluon momenta: while saturation effects in the target regulate some of the power-law IR-divergent terms in the lowest-order expression for the two-gluon correlator, other power-law IR-divergent terms remain, possibly due to absence of saturation effects in the dilute projectile. Finally we rewrite our result for the two-gluon production cross-section in a k T -factorized form, obtaining a new factorized expression involving a convolution of one- and two-gluon Wigner distributions over both the transverse momenta and impact parameters. Lastly, we show that the two-gluon production cross-section depends on two different types of unintegrated two-gluon Wigner distribution functions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Influence of the nucleon-nucleon collision geometry on the determination of the nuclear modification factor for nucleon-nucleus and nucleus-nucleus collisions

The influence of the underlying nucleon-nucleon collision geometry on evaluations of the nuclear overlap function (TAB) and number of binary collisions (Ncoll) is studied. A narrowing of the spatial distribution of the hard-partons with large light-cone fraction x in nucleons leads to a downward correction for Ncoll and TAB, which in turn, results in an upward correction for the nuclear modification factor RAB. The size of this correction is estimated for several experimentally motivated nucleon-nucleon overlap functions for hard-partons. It is found to be significant in peripheral nucleus-nucleus and nucleon-nucleus collisions, and is much larger at the LHC energy of {radical}s = 5.5 TeV than for the RHIC energy of {radical}s = 200 GeV. The implications for experimental measurements are also discussed.

43 PARTICLE ACCELERATORS↗

Quasi-Random Multimetallic Nanoparticle Arrays

Here, this paper describes a nanofabrication procedure that can generate multiscale substrates with quasi-random microregions of nanoparticle arrays having different periodicities and metals. We combine cycles of large-area nanoparticle array fabrication with solvent-assisted wrinkle lithography to mask and etch quasi-random areas of prefabricated nanoparticles to control the fill factors of the arrays. The approach is highly flexible, and parameters, including nanoparticle size and material, array geometry, and fill factor, can be tailored independently. Multimetallic nanoparticle arrays can support surface lattice resonances at fill factors as low as 20% and can function as nanoscale cavities for lasing action with as few as 10% of the nanoparticles in an array. We demonstrated that multimetallic nanoparticle substrates that combine two or three arrays with different periodicities can exhibit lasing responses over visible and near-infrared wavelengths. Our work showcases the robust optical responses of multimetallic and periodic devices for broadband light manipulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Shape Factor for Pits and Its Impact on Pit Stability

This study employs the finite element method (FEM) to predict the impact of pit shape on pit stability via shape factors of various pit geometries relevant to localized corrosion. Lower values of the shape factor indicate an increased ease in maintaining pit stability. Analyzed geometries include undercut pits, bispherical pit-within-pit structures, and covered pits with perforated (lacy) covers. The effect of the water layer thickness, transport properties of the electrolyte inside and outside the pit, and cathode location on the pit shape factor were also explored. Results show that occluded pits exhibit lower shape factors than open ones, with disk-shaped pits decreasing further as c/r ratio and occlusion angle increase. The findings also suggest minimal influence from a secondary pit if the primary remains active. An equation is presented that quantifies the impact of lacy covers, revealing significant shape factor value reduction. Additionally, high salt concentrations inside pits have a limited stabilizing effect compared to geometry, while thin water layers and adjacent cathodic/sinks reduce pit stability.

Shehi, A. (ORCID:0009000271548041)↗

ROLE OF SCALE FACTOR DURING TENSILE TESTING OF SMALL SPECIMENS

The influence of scale factor (tensile specimen geometry and dimensions) on mechanical test results was investigated for different widely used types of small specimens (SS-1, SS-2, SS-3, and SS-J3) and a set of materials. It was found that the effect of scale factor on the accurate determination of yield stress, ultimate tensile stress, and uniform elongation values was weak; however, clear systematic differences were observed and should be accounted for during interpretation of results. In contrast, total elongation values were strongly sensitive to variations in specimen geometry. Modern experimental methods like digital image correlation allow the impact of scale factor to be reduced. Using these techniques, it was shown that true stress true strain curves describing strain-hardening behavior were very close for different specimen types. The limits of miniaturization are discussed, and an ultra-miniature specimen concept was suggested and evaluated. This type of specimen, as expected, may be suitable for SEM and TEM in situ testing.

Gussev, Maxim N↗

Atomic-scale 3D structural dynamics and functional degradation of Pt alloy nanocatalysts during the oxygen reduction reaction

Pt-based electrocatalysts are the primary choice for fuel cells due to their superior oxygen reduction reaction (ORR) activity. To enhance ORR performance and durability, extensive studies have investigated transition metal alloying, doping, and shape control to optimize the three key governing factors for ORR: geometry, local chemistry, and strain of their surface and subsurface. However, systematic optimization remains incomplete, as it requires an atomic-scale understanding of these factors and their dynamics over potential cycling, as well as their relationship to ORR activity. Here, we implement neural network-assisted atomic electron tomography to measure the 3D atomic structural dynamics and their effects on the functional degradation of PtNi alloy catalysts. Our results reveal that PtNi catalysts undergo shape changes, surface alloying, and strain relaxation during cycling, which can be effectively mitigated by Ga doping. By combining geometry, local chemistry, and strain analysis, we calculated the changes in ORR activity over thousands of cycles and observed that Ga doping leads to higher initial activity and greater stability. These findings offer a pathway to understanding 3D atomic structural dynamics and their relation to ORR activity during cycling, paving the way for the systematic design of durable, high-efficiency nanocatalysts.

Jeong, Chaehwa↗

Development and Validation of Resistance-Capacitance Model (RCM) for Phase Change Material (PCM) Embedded in 3D Periodic Structures

The low thermal conductivity of Phase Change Materials (PCM) can be improved with extended surfaces such as additively manufactured 3D periodic lattice structures. Three different aluminum alloy-based lattices (base sizes 10, 20, and 40 mm) with average porosity of 0.95 filled with paraffin wax, with a nominal phase change temperature of 55°C, were experimentally investigated. In this work, a computationally efficient 2D Resistance Capacitance-based model (RCM) was developed for predicting the thermal characteristics of these geometries. Non-uniform porosity in the PCM-metal domain was estimated using image processing and served as model input. The solver does not solve for higher-order physics as in CFD but still can provide a good prediction of thermal resistance and energy storage at a very low computational cost. The simulation-to-real-time factor for this geometry is of the order of 10-4, while CFD simulations typically have a real-time factor greater than 1. The model was validated against the experimental data for melting under three different heat fluxes (6250 W/m2, 12500 W/m2, and 18750 W/m2). The mean deviation of the predicted average PCM temperature was between 1.34 K-2.81 K for different cases. The maximum average temperature deviation of 5.45 K was observed for the 20 mm geometry at the highest heat flux test condition. The effects of natural convection were neglected in the model, but the predicted PCM temperature and energy storage still showed good agreement with the experimental data.

25 ENERGY STORAGE↗

SU-F-T-67: Correction Factors for Monitor Unit Verification of Clinical Electron Beams

Purpose: Monitor units calculated by electron Monte Carlo treatment planning systems are often higher than TG-71 hand calculations for a majority of patients. Here I’ve calculated tables of geometry and heterogeneity correction factors for correcting electron hand calculations. Method: A flat water phantom with spherical volumes having radii ranging from 3 to 15 cm was created. The spheres were centered with respect to the flat water phantom, and all shapes shared a surface at 100 cm SSD. D{sub max} dose at 100 cm SSD was calculated for each cone and energy on the flat phantom and for the spherical volumes in the absence of the flat phantom. The ratio of dose in the sphere to dose in the flat phantom defined the geometrical correction factor. The heterogeneity factors were then calculated from the unrestricted collisional stopping power for tissues encountered in electron beam treatments. These factors were then used in patient second check calculations. Patient curvature was estimated by the largest sphere that aligns to the patient contour, and appropriate tissue density was read from the physical properties provided by the CT. The resulting MU were compared to those calculated by the treatment planning system and TG-71 hand calculations. Results: The geometry and heterogeneity correction factors range from ∼(0.8–1.0) and ∼(0.9–1.01) respectively for the energies and cones presented. Percent differences for TG-71 hand calculations drop from ∼(3–14)% to ∼(0–2)%. Conclusion: Monitor units calculated with the correction factors typically decrease the percent difference to under actionable levels, < 5%. While these correction factors work for a majority of patients, there are some patient anatomies that do not fit the assumptions made. Using these factors in hand calculations is a first step in bringing the verification monitor units into agreement with the treatment planning system MU.

60 APPLIED LIFE SCIENCES↗

Photonic mesophases from cut rod rotators

The photonic band properties of random rotator mesophases are calculated using supercell methods applied to cut rods on a hexagonal lattice. Inspired by the thermodynamic mesophase for anisotropic building blocks, we vary the shape factor of cut fraction for the randomly oriented basis. We find large, stable bandgaps with high gap isotropy in the inverted and direct structures as a function of cut fraction, dielectric contrast, and filling fraction. Bandgap sizes up to 34.5% are maximized at high dielectric contrast for rods separated in a matrix. The bandgaps open at dielectric contrasts as low as 2.0 for the transverse magnetic polarization and 2.25 for the transverse electric polarization. Additionally, the type of scattering that promotes the bandgap is correlated with the effect of disorder on bandgap size. Slow light properties are investigated in waveguide geometry and slowdown factors up to 5 × 10{sup 4} are found.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of Torque-Tube Parameters on Rear-Irradiance and Rear-Shading Loss for Bifacial PV Performance on Single-Axis Tracking Systems: Preprint

The emergence of cost-competitive bifacial PV modules has raised the question of the additional value of bifacial modules in 1-axis tracking arrays, in particular when considering rear-irradiance losses from the tracker system itself. In this work, the effect of different geometries and materials of torque tubes is evaluated and found to reduce rear-irradiance averages without any torque-tube shading by 0.1 to 12% for metallic and black absorptive torque tubes respectively for a clear-sky day. This paper will compare modeled to measured rear-irradiance profiles, and propose a recommended range of rear-shading loss factors for different geometry conditions. The effect of rear-irradiance distribution into electrical mismatch loss will also be explored.

14 SOLAR ENERGY↗

Heat transfer and friction factor correlations for a solar air heater duct roughened artificially with multiple v-ribs

The use of artificial roughness on the underside of the absorber plate is an effective and economic way to improve the thermal performance of a solar air heater. Several experimental investigations, involving different types of roughness elements, have been carried out to improve the heat transfer from the absorber plate to air flowing in solar air heaters. This paper presents an experimental investigation carried out to study the effect of multiple v-rib roughness on heat transfer coefficient and friction factor in an artificially roughened solar air heater duct. The experiment encompassed Reynolds number (Re) from 2000 to 20000, relative roughness height (e/D) values of 0.019-0.043, relative roughness pitch (P/e) range of 6-12, angle of attack ({alpha}) range of 30-75 and relative roughness width (W/w) range of 1-10. Extensive experimentation has been conducted to collect data on heat transfer and fluid flow characteristics of a rectangular duct roughened with multiple v-ribs. Using these experimental data, correlations for Nusselt number and friction factor in terms of roughness geometry and flow parameters have been developed. (author)

14 SOLAR ENERGY↗

MO-E-17A-05: Individualized Patient Dosimetry in CT Using the Patient Dose (PATDOSE) Algorithm

Purpose: Radiation dose to the patient undergoing a CT examination has been the focus of many recent studies. While CTDIvol and SSDE-based methods are important tools for patient dose management, the CT image data provides important information with respect to CT dose and its distribution. Coupled with the known geometry and output factors (kV, mAs, pitch, etc.) of the CT scanner, the CT dataset can be used directly for computing absorbed dose. Methods: The HU numbers in a patient's CT data set can be converted to linear attenuation coefficients (LACs) with some assumptions. With this (PAT-DOSE) method, which is not Monte Carlo-based, the primary and scatter dose are computed separately. The primary dose is computed directly from the geometry of the scanner, x-ray spectrum, and the known patient LACs. Once the primary dose has been computed to all voxels in the patient, the scatter dose algorithm redistributes a fraction of the absorbed primary dose (based on the HU number of each source voxel), and the methods here invoke both tissue attenuation and absorption and solid angle geometry. The scatter dose algorithm can be run N times to include Nth-scatter redistribution. PAT-DOSE was deployed using simple PMMA phantoms, to validate its performance against Monte Carlo-derived dose distributions. Results: Comparison between PAT-DOSE and MCNPX primary dose distributions showed excellent agreement for several scan lengths. The 1st-scatter dose distributions showed relatively higher-amplitude, long-range scatter tails for the PAT-DOSE algorithm then for MCNPX simulations. Conclusion: The PAT-DOSE algorithm provides a fast, deterministic assessment of the 3-D dose distribution in CT, making use of scanner geometry and the patient image data set. The preliminary implementation of the algorithm produces accurate primary dose distributions however achieving scatter distribution agreement is more challenging. Addressing the polyenergetic x-ray spectrum and spatially dependent scatter fractions will improve algorithm accuracy. Funding Support: UC Davis Clinical and Translational Science Center (CTSC) Award; NIH IMSD Student Fellowship; Saxon Student Fellowship Disclosure: PATENT Royalties from Samsung for dosimetry algorithm.

60 APPLIED LIFE SCIENCES↗

Coiled transmission line pulse generators

Methods and apparatus are provided for fabricating and constructing solid dielectric "Coiled Transmission Line" pulse generators in radial or axial coiled geometries. The pour and cure fabrication process enables a wide variety of geometries and form factors. The volume between the conductors is filled with liquid blends of monomers, polymers, oligomers, and/or cross-linkers and dielectric powders; and then cured to form high field strength and high dielectric constant solid dielectric transmission lines that intrinsically produce ideal rectangular high voltage pulses when charged and switched into matched impedance loads. Voltage levels may be increased by Marx and/or Blumlein principles incorporating spark gap or, preferentially, solid state switches (such as optically triggered thyristors) which produce reliable, high repetition rate operation. Moreover, these Marxed pulse generators can be DC charged and do not require additional pulse forming circuitry, pulse forming lines, transformers, or an a high voltage spark gap output switch. The apparatus accommodates a wide range of voltages, impedances, pulse durations, pulse repetition rates, and duty cycles. The resulting mobile or flight platform friendly cylindrical geometric configuration is much more compact, light-weight, and robust than conventional linear geometries, or pulse generators constructed from conventional components. Installing additional circuitry may accommodate optional pulse shape improvements. The Coiled Transmission Lines can also be connected in parallel to decrease the impedance, or in series to increase the pulse length.

McDonald, Kenneth Fox↗

Loss Factor of Tapered Structures for Short Bunches

Using the electromagnetic simulation code ECHO, we have found a simple phenomenological formula that accurately describes the loss factor for short bunches traversing an axisymmetric tapered collimator. In this paper, we consider tapered collimators with rectangular cross-section and use the GdfidL code to calculate the loss factor dependence on the geometric parameters for short bunches. The results for both axisymmetric and rectangular collimators are discussed. The behaviour of the impedance of tapered structures for very short bunches in the optical regime has been determined in refs. [10,11]. Here, for the loss factors for two particular geometries, we have studied the departure from the optical regime behaviour as bunch length is increased. In both cases, the ratio of the loss factor for the tapered collimator to the loss factor in the optical regime is a function only of the scaling parameter {sigma}L/d{sup 2}. The fact that the bunch length a and the taper length L appear as a product is consistent with the recent scaling derived by Stupakov in ref. [12], since there is only a weak dependence on g. One noteworthy fact that is not a priori expected is that only the larger radius or vertical half-aperture d appears. The reduction factor is independent of b. Moreover, it is striking that the specific form involving the arctan given in Eq. (5) holds for both geometries, with only the coefficient {mu} differing by a factor of {approx}2 for flat vs round. This suggests that there may be a useful phenomenological form for more general geometries which may follow from natural extensions of Eq. (5). This possibility is presently being investigated.

43 PARTICLE ACCELERATORS↗

Compact formulas for bounce/transit averaging in axisymmetric tokamak geometry

Compact formulas for bounce and transit orbit averaging of the fluctuation-amplitude eikonal factor in axisymmetric tokamak geometry, which is frequently encountered in bounce-gyrokinetic description of microturbulence, are given in terms of the Jacobi elliptic functions and elliptic integrals. These formulas are readily applicable to the calculation of the neoclassical susceptibility in the framework of modern bounce-gyrokinetic theory. In the long-wavelength limit for axisymmetric electrostatic perturbations, we recover the expression for the Rosenbluth-Hinton residual zonal flow [M. N. Rosenbluth and F. L. Hinton, Phys. Rev. Lett. 80, 724 (1998)] accurately.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗