Updates to USA Structures (Phase 3 Prototype): 2023-2024 Technical Report

The Oak Ridge National Laboratory (ORNL) team has successfully innovated geospatial data feature mapping and postprocessing workflows to support the USA Structures project supported by FEMA. This technical report highlights significant updates, improvements, and innovations for the USA Structures dataset, focusing on nine priority states.

97 MATHEMATICS AND COMPUTING

Hourly dynamic line ratings for existing transmission across the contiguous United States (preliminary results) [Slides]

The thermal rating of a transmission line depends on the rate at which heat generated by current flow through the line can be dissipated into the environment by convective and radiative cooling, keeping the conductor below a maximum operating temperature. Static or seasonal line ratings assume nearly-worst-case weather conditions (high ambient air temperature, high solar irradiance, and low wind speed), resulting in a low risk of "overrating" a line (i.e., allowing more current to flow than the line is designed for) but a high fraction of time when the line is "underrated" (i.e., able to flow more current while staying below the maximum temperature). Dynamic transmission line ratings (DLR) use real-time measurements of weather conditions, line sag, or line temperature to determine the thermal rating of transmission lines at hourly or higher time resolution, allowing for increased ratings during some (cold, windy, and/or dark) periods and correcting for overrating during other (hot, calm, and/or sunny) periods. Many studies have explored the benefits of DLR, but typically for small collections of transmission lines under a limited sample of weather conditions, leaving open the question of how widely applicable the benefits of DLR might be over diverse geographies and weather conditions. Here, we combine geospatial data on tens of thousands of transmission line routes across the contiguous United States with high-resolution hourly historical weather data for 2007-2013 to estimate the impact of DLR and other weather-adjusted rating systems. We compare static and dynamic line ratings to intermediate ratings adjusted by ambient temperature, day/night irradiance, clear-sky irradiance, and/or measured irradiance, illustrating the benefits of incorporating progressively more detailed weather data into the calculated line ratings. Moving from nighttime-adjusted ratings to clear-sky-adjusted ratings provides more benefit than moving from clear-sky-adjusted ratings to measured-irradiance-adjusted ratings. Depending on the assumed static windspeed for irradiance-adjusted-ratings, DLR either corrects for overrated hours or provides substantially increased ratings in the majority of hours on the majority of lines.

14 SOLAR ENERGY

Mapping Support for Targeted Critical Minerals Exploration and Extraction

The United States’ dependency on imported minerals poses significant risks to economic stability and national security due to potential supply disruptions. Recognizing the strategic importance of critical minerals, the Department of Energy (DOE) emphasizes the need for a secure and resilient supply chain to support emissions reduction, technology development, and capitalization on clean energy opportunities. The DOE’s Office of Manufacturing and Energy Supply Chains (MESC), in collaboration with the Office of Policy (OP), addresses these vulnerabilities by focusing on upstream domestic critical minerals production, balancing extraction with social and environmental goals, including conservation, environmental justice, and respect for Tribal sovereignty. This report showcases a collaborative effort involving Idaho National Laboratory (INL), Argonne National Laboratory (Argonne), National Renewable Energy Laboratory (NREL), and the U.S. Geological Survey (USGS) to map mineral development potential along with key social and environmental datasets. A geographical information system (GIS)-based web map application was developed as a preliminary tool for environmental analysis, integrating 158 geospatial data layers such as critical habitat, land ownership, economic indicators, and environmental concerns. Data were sourced from agencies like the Bureau of Land Management (BLM) and USGS and processed using GIS technology to enhance visualization and analysis. The proposed analysis framework categorizes areas into high, mid, and low concern based on withdrawn lands, special status species, the Economic Development Capacity Index (EDCI) Mining Composite Index, and the Climate and Economic Justice Screening Tool (CEJST). While the application provides broad visualizations, it is not a substitute for detailed environmental reviews required under the National Environmental Policy Act (NEPA). Users must conduct further analyses and engage with tribal entities and other stakeholders for comprehensive planning. A case study of the Idaho Cobalt Belt (ICB) in Lemhi County, Idaho, has been provided in the report to illustrate the tool's practical use. This report introduces a GIS application and framework to support stakeholders in identifying and prioritizing areas for critical mineral exploration, promoting secure supply chains, and advancing the nation's energy independence through responsible resource stewardship.

54 ENVIRONMENTAL SCIENCES

Vexcel Imaging's Suitability for Automatic Verification

Accurate, independently verified geospatial data is essential for automated calibration, validation, and operational decision-making. This study evaluated the positional accuracy of Vexcel Imaging™’s UltraCam® Osprey imagery (7.5 cm GSD) using globally distributed Continuously Operating Reference Stations (CORS) as independent control. Despite manufacturer claims of 15 cm horizontal accuracy, residual errors were consistently one to two orders of magnitude larger, with no subset of imagery meeting precision thresholds. These discrepancies cannot be explained by normal photogrammetric or environmental factors and raise concerns about the reliability of the imagery for high-precision tasks. The results demonstrate that Vexcel imagery, in its current form, is unsuitable for workflows requiring rigorous spatial accuracy or automated verification. At the same time, the reproducible validation framework developed in this study establishes a scalable method for assessing commercial imagery, ensuring that future products can be independently and objectively verified before operational adoption.

47 OTHER INSTRUMENTATION

National Modeling of Geothermal District Energy Systems with Ambient-Temperature Loops Using dGeo: Preprint

Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. Using GHEDesigner, a lookup table was created to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on agent energy bills. This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of different costing and pricing future scenarios. While the code is still under development and nationwide simulations are ongoing, initial results for two states are provided. Future work includes expanding the module to consider mixed residential and commercial districts and considering multiple costing scenarios.

ambient temperature loop

National Modeling of Geothermal District Energy Systems with Ambient-Temperature Loops Using dGeo

Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. A lookup table was created using GHEDesigner to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on energy bills for building owners (agents). This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of future cost and price scenarios. Initial results for statewide analysis (for Vermont) and nationwide (for United States) are provided. Future work includes expanding the module to consider mixed residential and commercial districts as well as evaluating multiple cost scenarios.

ambient-temperature loop

GeoGridFusion (Open-Source Geospatial Toolkit for Solar Data Integration​) [SWR-25-19]

GeoGridFusion facilitates the usage and storage of gridded geospatial satellite data by users outside of the National Renewable Lab (NREL), particularly those without access to high-performance computing (HPC) resources. This tool builds on work done by the PVDegradationTools project for DuraMAT, with the goal of making our advancements from this project widely accessible. This repo contains utilities to allow for the storage of user downloaded geospatial weather data by providing a local datastore for storage and spatial queries, supporting large-scale analyses without the need for HPC resources.

Ford, Tobin [National Renewable Energy Laboratory

Scalable and Secure Power Outage Data Reporting: A Hexagonal Geospatial Approach

Power outages disrupt critical infrastructure and cause billions of dollars in economic losses annually in the United States. Accurate and granular outage reporting is vital for effective restoration and mitigation. This paper examines the integration of the Hexagonal Hierarchical Geospatial Indexing System (H3) to enhance power outage reporting, leveraging its uniform grid structure, scalable resolutions, and support for privacy-preserving analysis. Using high-resolution LandScan Global population data and K-anonymization techniques, this work achieves a balance between data granularity and privacy. Results show that lower privacy thresholds (e.g., K-anonymity = 2) enable higher resolution, while stricter thresholds (e.g., >15 people per hex) reduce granularity, potentially affecting localized responses. State-and county-level resolution case studies demonstrate H3’s adaptability and the trade-offs between precision and privacy. The proposed H3-based framework offers a scalable and efficient solution for geospatial data integration within the energy sector, such as outage data, aiding utilities and regulators in improving resilience and response efforts, particularly in disaster-prone regions.

Ahmad, Nasir [ORNL] (ORCID:0000000150677368)

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)

Smart CO2 Transport-Route Planning Tool

NETL has developed the Smart CO2 Transport-Route Planning Tool to help inform energy transport planning and development. The stand-alone, open-source tool applies data-driven, geospatial and machine-learning informed logic to identify potential routes or evaluate existing corridors based on current legislation, best construction practices, and more. Underpinning the interactive tool, is NETL’s CO2 Transport Planning Database (https://edx.netl.doe.gov/dataset/ccs-pipeline-route-planning-database-v1). This geospatial resource contains more than 70 gigabytes of data representing more than 60 critical factors for the spatial routing of CO2 transport, including land use requirements, existing infrastructure, high consequence areas, and natural hazards.

Bipartisan Infrastructure Law

Geospatial Capabilities to Couple Hazard and Social Vulnerability Data in Water Distribution Criticality Analysis

A resilience analysis of a water distribution system is greatly enhanced by the integration of up-to-date geospatial data describing the water system, hazards, and surrounding community. The Water Network Tool for Resilience (WNTR), an open-source Python package designed to simulate and analyze the resilience of water distribution systems, was recently updated to incorporate geographic information system (GIS) data into the resilience analysis. This paper describes the GIS capabilities and includes a case study using the drinking water distribution system model for a large city in Pennsylvania. The case study focuses on potential pipe damage from landslides and on pipes that are particularly difficult to repair. The analysis couples data on hazards, social vulnerability, and the location of emergency services to identify and prioritize high-impact critical infrastructure for mitigation. Results demonstrate that pipes can be prioritized for mitigation based on water shortage and vulnerable populations that are affected. In conclusion, the methods can be adopted for general use and are available as part of the WNTR software.

GIS, landslide

Geospatial characterization of low-temperature heating and cooling demand in residential, commercial, manufacturing, agricultural, and data center sectors for potential geothermal applications in the United States

Thermal demand for heating and cooling has been predominantly supplied by fossil fuel combustion in the United States, although low-carbon alternatives are extensively available including geothermal, solar thermal, and waste heat. Here, this study analyzed end-use energy consumption, fuel expenditure, and data center commissioned power data to geospatially characterize the U.S. low-temperature heating and cooling demand at the county level in residential, commercial, manufacturing, agricultural, and data center sectors and understand potential opportunities for geothermal applications. In the analysis, the regional-scale energy consumption data was incorporated with system efficiencies to address actual demand and was then disaggregated with weighting factors to the county level. The results indicated that total low-temperature heating and cooling demand is 16.7 EJ, combining heating demand of 10.8 EJ and cooling demand of 5.9 EJ. Overall, 59.9 % (10 EJ) of the low-temperature heating and cooling demand occurred in the residential sector. The heating and cooling demand visualized in maps represented that the geospatial distribution of heating and cooling demand in the residential and commercial sectors is governed by the number of housing units and climate zone designations, while heating and cooling demand in the manufacturing, agricultural, and data center sectors is dependent on the number and location of facilities. The results also demonstrated that geothermal heat pumps are broadly used in the residential and commercial sectors for heating and cooling in the U.S. Midwest, South, and Northeast regions but are limited in the West, implying great decarbonization potential in the future.

15 GEOTHERMAL ENERGY

Data and scripts associated with “Non-random processes impacting organic matter chemistry are maximized in mid-order streams”

NOTE: The manuscript associated with this data package is currently in review. The data may be revised based on reviewer feedback. Upon manuscript acceptance, this data package will be updated with the final dataset and additional metadata. This data package is associated with the publication “Non-random processes impacting organic matter chemistry are maximized in mid-order streams” submitted to Limnology and Oceanography (L&O) by Danczak et al. (in review). This package contains data and scripts used to investigate dissolved organic matter (DOM) molecular chemistry and diversification processes across 47 surface-water sampling sites in the Yakima River Basin, Washington, USA, during an August 2021 sampling campaign. The package contains analyses of ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS), geochemical measurements, geospatial attributes, molecular diversity, and meta-metabolome ecological null models needed to reproduce the main manuscript results. The underlying field data were pulled from exising data packages at https://doi.org/10.15485/1892052 (Fulton et al., 2022) and https://doi.org/10.15485/1898914 (Grieger et al., 2022). For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. We thank the following organizations for providing access to field locations for sample collection: the United States Forest Service, Washington Department of Fish and Wildlife, Washington Department of Natural Resources, the Confederated Tribes and Bands of the Yakama Nation, and the Cowiche Canyon Conservatory. Research was conducted under Washington State Parks and Recreation Commission Scientific Research Permit #210901. We are grateful to the Yakama Nation Tribal Council and Yakama Nation Fisheries for their collaboration in facilitating sample collection and ensuring data usage aligns with their values and worldview. This data package contains an R-Markdown file for analyses and five folders: (1) Data, (2) Geospatial Data, (3) Supplemental_Files, (5) Figures_pdf, (4) and src. The Data folder contains tabular inputs and derived files used in the manuscript analysis. The Geospatial Data folder contains climate and water-balance, hydrologic, land-cover, population/regional water-use, stream, topographic, and stream-order attribute CSV files. The src folder contains scripts used to process data, run analyses, and generate figures. The Figures_pdf folder contains manuscript figure outputs. The Supplemental_Files folder contains supplemental analysis products. All files are .csv, .pdf, .html, .png, .R, .Rmd, .svg, or .tre. This data package is associated with the rcfsa-RC2-SPS_Null_Modeling repository found at https://github.com/river-corridors-sfa/rcfsa-RC2-SPS_Null_Modeling.

54 ENVIRONMENTAL SCIENCES

Circularity Futures Workshop Series: Summary Report

The aim of this report is to synthesize key feedback received from the three-part Circularity Futures workshop series held in Spring 2024. The workshop series was conducted by the National Renewable Energy Laboratory (NREL) on behalf of U.S. Department of Energy, Office Energy Efficiency and Renewable Energy (EERE), and was broken into three workshops: Workshop 1 - Circularity Analysis Needs and Priorities; Workshop 2 - Circularity Metrics and Indicators; and Workshop 3 - Circularity Data. Together, the workshops focused on identifying the existing priorities and gaps in the circularity modeling space, understanding different stakeholders' use and interpretation of circularity metrics and indicators, identifying common data gaps and data quality challenges, and assessing the robustness of available solutions. The workshop series brought a diverse group of stakeholders - including representatives from U.S. government offices, national labs, nonprofit organizations, industry, and academia - to collect first-hand feedback on needs, priorities, challenges and opportunities in the circularity modeling and analysis space. The workshop discussions highlighted numerous common needs, priorities and challenges among the interviewed groups. Several topics were frequently discussed, including: 1) Circularity as a pathway for sustainable economic growth: While circularity is generally defined in terms of resource conservation and reducing wasteful disposal of materials, participants agreed that circular strategies should serve broader economic, environmental, and social goals. It is therefore crucial for circularity analysis to look beyond waste reduction and instead evaluate a variety of impact metrics such as cost savings, job creation, air quality, and pollutant emissions. Mutli-criteria decision-making frameworks may be useful for making sense of disparate metrics and evaluating tradeoffs between impact categories.; 2) Economic and social factors are not well understood: Underdevelopment of existing end-of-life (EOL) management infrastructure, inconsistent standardization codes and policy space in reusing recycled content, and suboptimal collection and sorting strategies collectively contribute to uncertainty about the economic potential of circular pathways. The latter observation is consistent among all technologies but more emphasized for renewable energy systems. Social impacts of circularity practices are less understood and less researched than other sustainability aspects.; 3) Inconsistent methods for assessing emerging technologies: LCA and TEA results vary widely depending on the assumptions made with regards to market adoption of new technologies. Emerging technologies suffer limited availability of data needed to conduct a robust circularity analysis. Yet, understanding projected impacts of proposed nascent technology is a key need for different stakeholder groups.; and 4) Lack of temporally and geospatially explicit data: There is a need for open data that represents variations in circularity technologies over time and location. The lack thereof leads to aggregated and potentially misrepresented results in circularity analysis. Sensitivity analyses should be included to verify whether options perceived as more sustainable align with real-world practices.

29 ENERGY PLANNING, POLICY, AND ECONOMY

High Resolution Siting Suitability of Various Power Plant Technologies

Energy sector planning models determine the aggregate need for new generation, but these models are typically at the state or regional scale and are not equipped to address the wide range of location- and technology-specific issues that are increasingly a factor in power plant siting. These animations demonstrate the aggregate siting suitability of various power plant technology configurations, considering technology-specific factors that can prohibit development. The data presented is from the GRIDCERF (Geospatial Raster Input Data for Capacity Expansion Regional Feasibility) data package. GRIDCERF is a harmonized, open-source geospatial product that can be used to evaluate siting suitability for renewable and non-renewable power plants in the conterminous United States. The animations presented here demonstrate a curated selection of the full suite of technology configurations available. GRIDCERF provides the necessary inputs for models that simulate power plant siting for regional capacity expansion planning such as the Capacity Expansion Regional Feasibility (CERF) model.

Mongird, Kendall [Pacific Northwest National Labor

Data Fusion for the Development of a Multimodal Freight Transload Facilities Dataset in the U.S.

To withstand the growing demand of commodity volume and its strain on the transportation infrastructure, it is necessary to identify the flow of commodities by route and mode. However, a national multimodal freight routing model does not exist for the U.S. The development of such model requires multiple building blocks, such as virtual representations of roadway, railway, and waterway networks, transload facilities (TFs), and access/egress links. Most of these blocks have a robust database in the U.S., except for the TFs. Here, this paper presents the fusion of dispersed and heterogeneous representations of multimodal TFs into a single, comprehensive, geospatial freight TF dataset. The TF dataset is derived from several sources, including the U.S. Army Corps of Engineers Master Docks Plus, the National Transportation Atlas Database, the Intermodal Association of North America, industry publications, and other public information. First, individual datasets were queried and reconciled. A geocoding/reverse geocoding process was applied to get the best street address and latitude/longitude location for each terminal. Then, duplicate terminals were identified by a fuzzy match algorithm based on terminal name and location, and removed. Validation was performed by visual inspection of random facilities. The main contributions of this work are: a publicly available version of the TF dataset, including facility location and multimodal transfer capability of 9,003 facilities, and an enterprise-version with the same facilities but including commodity handling capabilities. The main purpose of developing the TF dataset is to inform multimodal routing algorithms. The proposed TF dataset allows for credibly modeling the multimodal transfer of commodities within shipment routes.

Commodity Routing

Wind Turbine Sound Setbacks and Supply Curves: Ordinances and Extrapolated Trends, 110 Hub Height, 130 Rotor Diameter

This dataset provides a comprehensive set of wind turbine sound setbacks from every residential structure in the contiguous United States (CONUS). A sound setback is defined as the minimum required distance between a residential structure and a hypothetical turbine installation site to ensure that modeled sound levels received at the residence do not exceed local sound ordinances, which are commonly expressed in A-weighted decibels (dBA). Therefore, sound setbacks are a local spatial assessment combining multiple factors, including the sound pressure curve as a function of the observer location (distance and direction) relative to the turbine, local sound regulations, and the geographical distribution of residential structures. The dataset is organized into multiple scenario-based products, detailed as follows: 1. Existing and extrapolated sound setbacks. An existing scenario characterizes sound setbacks only in states or counties that have implemented sound regulations as of 2022. The extrapolated scenarios extend a constant sound threshold to counties that lack explicit sound regulations, with thresholds ranging from 35 to 60 dBA, in 5-dBA increments reflecting the variation observed in current sound ordinances. 2. Sound setbacks in directional and worst scenarios. The directional scenario accounts for the distance and orientation of residential structures relative to a hypothetical turbine location, utilizing the turbine's sound emissions in that specific direction. In contrast, the worst scenario takes loudest sound level at each distance step from the turbine, irrespective of directional considerations, which aligns with current industry practice. 3. Supply curves for Open and Reference Access scenarios. This dataset includes supply curves generated by the reV model, which integrates each of the above sound setbacks into both Open and Reference siting scenarios. In addition, two Open and Reference baselines scenarios were included which do not consider sound setbacks for comparative analysis. All sound setback data are stored in TIF files, with partial maps of the data provided in PNG format. The values in the sound setback raster range from 0 to 1, representing the fraction of developable land within a 90 meter by 90 meter pixel due to sound ordinances. A value of 0 indicates areas where wind energy development is prohibited, while a value of 1 signifies areas fully permissible. The wind turbine parameters used in the sound modeling are based on the land-based turbine from International Energy Agency (IEA), featuring a rated electrical power of 3.4 MW, a rotor diameter of 130 meters, and a hub height of 110 meters. The atmospheric conditions, including wind speed/direction, turbulence, air temperature, relative humidity, and air pressure, that drive the sound generation are obtained from the WIND Toolkit dataset.