SEARCH · Search NASA
Results for “grade”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Emission pattern control and polarized light emission through patterned graded-refractiveindex coatings on GaInN light-emitting diodes
Explore the source record for details and available documents.
Transport of minority-carriers in graded-composition semiconductors and its impact on graded-band-gap base transistors operated at high currents
Explore the source record for details and available documents.
Grade Inflation in Medical Student Radiation Oncology Clerkships: Missed Opportunities for Feedback?
Purpose: To test the hypothesis that medical student radiation oncology elective rotation grades are inflated and cannot be used to distinguish residency applicants. Methods and Materials: The records of 196 applicants to a single radiation oncology residency program in 2011 and 2012 were retrospectively reviewed. The grades for each rotation in radiation oncology were collected and converted to a standardized 4-point grading scale (honors, high pass, pass, fail). Pass/fail grades were scored as not applicable. The primary study endpoint was to compare the distribution of applicants' grades in radiation oncology with their grades in medicine, surgery, pediatrics, and obstetrics/gynecology core clerkships. Results: The mean United States Medical Licensing Examination Step 1 score of the applicants was 237 (range, 188-269), 43% had additional Masters or PhD degrees, and 74% had at least 1 publication. Twenty-nine applicants were graded for radiation oncology rotations on a pass/fail basis and were excluded from the final analysis. Of the remaining applicants (n=167), 80% received the highest possible grade for their radiation oncology rotations. Grades in radiation oncology were significantly higher than each of the other 4 clerkships studied (P<.001). Of all applicants, 195 of 196 matched into a radiation oncology residency. Higher grades in radiation oncology were associated with significantly higher grades in the pediatrics core clerkship (P=.002). However, other medical school performance metrics were not significantly associated with higher grades in radiation oncology. Conclusions: Although our study group consists of a selected group of radiation oncology applicants, their grades in radiation oncology clerkships were highly skewed toward the highest grades when compared with grades in other core clerkships. Student grading in radiation oncology clerkships should be re-evaluated to incorporate more objective and detailed performance metrics to allow for meaningful feedback to trainees and to better evaluate residency applicants to radiation oncology.
Can MRI be used to diagnose histologic grade in T1a (< 4 cm) clear cell renal cell carcinomas?
Objective: To assess whether MRI can differentiate low-grade from high-grade T1a cc-RCC. Materials and methods: With IRB approval, 49 consecutive solid < 4 cm cc-RCC (low grade [Grade 1 or 2] N = 38, high grade [Grade 3] N = 11) with pre-operative MRI before nephrectomy were identified between 2013 and 2018. Tumor size, apparent diffusion coefficient (ADC) histogram analysis, enhancement wash-in and wash-out rates, and chemical shift signal intensity index (SI index) were assessed by a blinded radiologist. Subjectively, two blinded Radiologists also assessed for (1) microscopic fat, (2) homogeneity (5-point Likert scale), and (3) ADC signal (relative to renal cortex); discrepancies were resolved by consensus. Outcomes were studied using Chi square, multivariate analysis, logistic regression modeling, and ROC. Inter-observer agreement was assessed using Cohen’s kappa. Results: Tumor size was 24 ± 7 (13–39) mm with no association to grade (p = 0.45). Among quantitative features studied, corticomedullary phase wash-in index (p = 0.015), SI index (p = 0.137), and tenth-centile ADC (p = 0.049) were higher in low-grade tumors. 36.8% (14/38) low-grade tumors versus zero high-grade tumors demonstrated microscopic fat (p = 0.015; Kappa = 0.67). Microscopic fat was specific for low-grade disease (100.0% [71.5–100.0]) with low sensitivity (36.8% [21.8–54.6]). Other subjective features did not differ between groups (p > 0.05). A logistic regression model combining microscopic fat + wash-in index + tenth-centile-ADC yielded area under ROC curve 0.98 (Confidence Intervals 0.94–1.0) with sensitivity/specificity 87.5%/100%. Conclusion: The combination of microscopic fat, higher corticomedullary phase wash-in and higher tenth-centile ADC is highly accurate for diagnosis of low-grade disease among T1a clear cell RCC.
Geological Modeling of Gold Deposit Based on Grade Domaining Using Plurigaussian Simulation Technique
Mineral resource evaluation requires defining grade domains of an ore deposit. Common practice in mineral resource estimation consists of partitioning the ore body into several grade domains before the geostatistical modeling and estimation at unsampled locations. Many ore deposits are made up of different mineralogical ensembles such as oxide and sulfide zone: being able to model the spatial layout of the different grades is vital to good mine planning and management. This study addresses the application of the plurigaussian simulation to Sivas (Turkey) gold deposits for constructing grade domain models that reproduce the contacts between different grade domains in accordance with geologist's interpretation. The method is based on the relationship between indicator variables from grade distributions on the Gaussian random functions chosen to represent them. Geological knowledge is incorporated into the model by the definition of the indicator variables, their truncation strategy, and the grade domain proportions. The advantages of the plurigaussian simulation are exhibited through the case study. The results indicated that the processes are seen to respect reproducing complex geometrical grades of an ore deposit by means of simulating several grade domains with different spatial structure and taking into account their global proportions. The proposed proportion model proves as simple to use in resource estimation, to account for spatial variations of the grade characteristics and their distribution across the studied area, and for the uncertainty in the grade domain proportions. The simulated models can also be incorporated into mine planning and scheduling.
Initial Comparison of Baseline Physical and Mechanical Properties for the VHTR Candidate Graphite Grades
High-purity graphite is the core structural material of choice in the Very High Temperature Reactor (VHTR) design, a graphite-moderated, helium-cooled configuration capable of producing thermal energy for power generation as well as process heat for industrial applications that require temperatures higher than the outlet temperatures of present nuclear reactors. The Baseline Graphite Characterization Program is establishing accurate as-manufactured mechanical and physical property distributions in nuclear-grade graphites by providing comprehensive data that captures the level of variation in measured values. In addition to providing a thorough comparison between these values in different graphite grades, the program is also carefully tracking individual specimen source, position, and orientation information in order to provide comparisons both in specific properties and in the associated variability between different lots, different billets, and different positions from within a single billet. This report is a preliminary comparison between each of the grades of graphite that are considered “candidate” grades from four major international graphite producers. These particular grades (NBG-18, NBG-17, PCEA, IG-110, and 2114) are the major focus of the evaluations presently underway on irradiated graphite properties through the series of Advanced Graphite Creep (AGC) experiments. NBG-18, a medium-grain pitch coke graphite from SGL from which billets are formed via vibration molding, was the favored structural material in the pebble-bed configuration. NBG-17 graphite from SGL is essentially NBG-18 with the grain size reduced by a factor of two. PCEA, petroleum coke graphite from GrafTech with a similar grain size to NBG-17, is formed via an extrusion process and was initially considered the favored grade for the prismatic layout. IG-110 and 2114, from Toyo Tanso and Mersen (formerly Carbone Lorraine), respectively, are fine-grain grades produced via an isomolding process. An analysis of the comparison between each of these grades will include not only the differences in fundamental and statistically-significant individual strength levels, but also the differences in the overall variability in properties within each of the grades that will ultimately provide the basis for predicting in-service performance. The comparative performance of the different types of nuclear-grade graphites will naturally continue to evolve as thousands more specimens are fully characterized with regard to strength, physical properties, and thermal performance from the numerous grades of graphite being evaluated.
Geometrical Sparing Factors for the Rectum and Bladder in the Prediction of Grade 2 and Higher Complications After High-Dose-Rate Brachytherapy for Cervical Cancer
Purpose: This study aimed to assess the predictive values of geometrical sparing factors for the rectum and bladder in high-dose-rate intracavitary brachytherapy (HDRICB) for Grade 2 and higher late sequelae in patients with cervical cancer. Methods: A total of 392 patients were enrolled in this study. They were treated with external beam radiotherapy to the pelvis, after which HDRICB was performed using Ir-192 remote after-loading at 1-week intervals for three or four sessions. The geometrical sparing factor (GSF) was defined as the average of the ratios between the reference doses and the Point A dose. Results: A total of 46 patients (11.7%) had Grade 2 or higher late rectal complications (36 Grade 2, 9 Grade 3, and 1 Grade 4). In all, 32 patients (8.2%) had Grade 2 or higher late bladder complications (14 Grade 2, 16 Grade 3, and 2 Grade 4). Multivariate analysis demonstrated a high risk of rectal sequelae in patients who developed bladder complications (p = 0.0004, hazard ratio 3.54) and had a rectal GSF greater than 0.7 (p = 0.01, hazard ratio 1.99). The high risk factors for bladder complications were development of rectal complications (p = 0.0004, hazard ratio 3.74), concurrent chemotherapy (p = 0.0001, relative risk 3.94), and a bladder GSF greater than 0.9 (p = 0.01, hazard ratio, 2.53). Conclusion: This study demonstrates the predictive value of GSFs in HDRICB for cervical cancer. Patients with rectal GSFs greater than 0.7 or bladder GSFs greater than 0.9 are at risk for Grade 2 and higher late sequelae.
Low Interrater Reliability in Grading of Rectal Bleeding Using National Cancer Institute Common Toxicity Criteria and Radiation Therapy Oncology Group Toxicity Scales: A Survey of Radiation Oncologists
Purpose: To measure concordance among genitourinary radiation oncologists in using the National Cancer Institute Common Toxicity Criteria (NCI CTC) and Radiation Therapy Oncology Group (RTOG) grading scales to grade rectal bleeding. Methods and Materials: From June 2013 to January 2014, a Web-based survey was sent to 250 American and Canadian academic radiation oncologists who treat prostate cancer. Participants were provided 4 case vignettes in which patients received radiation therapy and developed rectal bleeding and were asked for management plans and to rate the bleeding according to NCI CTC v.4 and RTOG late toxicity grading (scales provided). In 2 cases, participants were also asked whether they would send the patient for colonoscopy. A multilevel, random intercept modeling approach was used to assess sources of variation (case, respondent) in toxicity grading to calculate the intraclass correlation coefficient (ICC). Agreement on a dichotomous grading scale (low grades 1-2 vs high grades 3-4) was also assessed, using the κ statistic for multiple respondents. Results: Seventy-two radiation oncologists (28%) completed the survey. Forty-seven (65%) reported having either written or been principal investigator on a study using these scales. Agreement between respondents was moderate (ICC 0.52, 95% confidence interval [CI] 0.47-0.58) when using NCI CTC and fair using the RTOG scale (ICC 0.28, 95% CI 0.20-0.40). Respondents who chose an invasive management were more likely to select a higher toxicity grade (P<.0001). Using the dichotomous scale, we observed moderate agreement (κ = 0.42, 95% CI 0.40-0.44) with the NCI CTC scale, but only slight agreement with the RTOG scale (κ = 0.19, 95% CI 0.17-0.21). Conclusion: Low interrater reliability was observed among radiation oncologists grading rectal bleeding using 2 common scales. Clearer definitions of late rectal bleeding toxicity should be constructed to reduce this variability and avoid ambiguity in both reporting and interpretation.
Evaluating the Impact of Road Grade on Simulated Commercial Vehicle Fuel Economy Using Real-World Drive Cycles
Commercial vehicle fuel economy is known to vary significantly with both positive and negative road grade. Medium- and heavy-duty vehicles operating at highway speeds require incrementally larger amounts of energy to pull heavy payloads up inclines as road grade increases. Non-hybrid vehicles are then unable to recapture energy on descent and lose energy through friction braking. While the on-road effects of road grade are well understood, the majority of standard commercial vehicle drive cycles feature no climb or descent requirements. Additionally, existing literature offers a limited number of sources that attempt to estimate the on-road energy implications of road grade in the medium- and heavy-duty space. This study uses real-world commercial vehicle drive cycles from the National Renewable Energy Laboratory's Fleet DNA database to simulate the effects of road grade on fuel economy across a range of vocations, operating conditions, and locations. Drive-cycles are matched with vocation-specific vehicle models and simulated with and without grade. Fuel use due to grade is presented, and variation in fuel consumption due to drive cycle and vehicle characteristics is explored through graphical and statistical comparison. The results of this study suggest that road grade accounts for 1%-9% of fuel use in commercial vehicles on average and up to 40% on select routes.
Residual Stresses in Explosively Welded Plates Made of Titanium Grade 12 and Steel with Interlayer
Distributions of residual stress components in explosively welded three-layer plate composed of titanium Grade 12, titanium Grade 1 and SA516 Grade 70 steel are investigated in this paper. The study applied the sectioning and the hole-drilling strain gage methods for residual stress measurement. The results have shown an inhomogeneous residual stress distribution, approximated by fourth-order polynomial along the thickness of a three-layer plate. Biaxial compressive residual stress state is observed in titanium Grade 12 and Grade 1 layers which change to tensile type in the vicinity of the interface between titanium Grade 1 and steel. Microstructure observation reveals the presence of the adiabatic shear bands in titanium Grade 12 layer at the interface with titanium Grade 1 interlayer. The observed distribution of residual stress components is justified by the occurrence of the shock wave phenomena.
SU-D-207B-02: Early Grade Classification in Meningioma Patients Combining Radiomics and Semantics Data
Purpose: The clinical management of meningioma is guided by its grade and biologic behavior. Currently, diagnosis of tumor grade follows surgical resection and histopathologic review. Reliable techniques for pre-operative determination of tumor behavior are needed. We investigated the association between imaging features extracted from preoperative gadolinium-enhanced T1-weighted MRI and meningioma grade. Methods: We retrospectively examined the pre-operative MRI for 139 patients with de novo WHO grade I (63%) and grade II (37%) meningiomas. We investigated the predictive power of ten semantic radiologic features as determined by a neuroradiologist, fifteen radiomic features, and tumor location. Conventional (volume and diameter) imaging features were added for comparison. AUC was computed for continuous and χ{sup 2} for discrete variables. Classification was done using random forest. Performance was evaluated using cross validation (1000 iterations, 75% training and 25% validation). All p-values were adjusted for multiple testing. Results: Significant association was observed between meningioma grade and tumor location (p<0.001) and two semantic features including intra-tumoral heterogeneity (p<0.001) and overt hemorrhage (p=0.01). Conventional (AUC 0.61–0.67) and eleven radiomic (AUC 0.60–0.70) features were significant from random (p<0.05, Noether test). Median AUC values for classification of tumor grade were 0.57, 0.71, 0.72 and 0.77 respectively for conventional, radiomic, location, and semantic features after using random forest. By combining all imaging data (semantic, radiomic, and location), the median AUC was 0.81, which offers superior predicting power to that of conventional imaging descriptors for meningioma as well as radiomic features alone (p<0.05, permutation test). Conclusion: We demonstrate a strong association between radiologic features and meningioma grade. Pre-operative prediction of tumor behavior based on imaging features offers promise for guiding personalized medicine and improving patient management.
Proximity Ferroelectricity in Compositionally Graded Structures
Proximity ferroelectricity is a novel paradigm for inducing ferroelectricity in a non-ferroelectric polar material, such as AlN or ZnO that are typically unswitchable with an external field below their dielectric breakdown field. When placed in direct contact with a thin switchable ferroelectric layer (such as Al 1-x Sc x N or Zn 1-x Mg x O), they become a practically switchable ferroelectric. Using the thermodynamic Landau-Ginzburg-Devonshire theory, in this work, we perform the finite element modeling of the polarization switching in the compositionally graded AlN-Al 1-x Sc x N, ZnO-Zn 1-x Mg x O, and MgO-Zn 1-x Mg x O structures sandwiched in both a parallel-plate capacitor geometry as well as in a sharp probe-planar electrode geometry. We reveal that the compositionally graded structure allows the simultaneous switching of spontaneous polarization in the whole system by a coercive field significantly lower than the electric breakdown field of unswitchable polar materials. The physical mechanism is the depolarization electric field determined by the gradient of chemical composition “x”. The field lowers the steepness of the switching barrier in the otherwise unswitchable parts of the compositionally graded AlN-Al 1-x Sc x N and ZnO-Zn 1-x Mg x O structures. In the MgO-like regions of the compositionally graded MgO-Zn 1-x Mg x O structure, a shallow double-well free energy potential emerges. Proximity ferroelectric switching of the compositionally graded structures placed in the probe-electrode geometry occurs due to nanodomain formation under the tip. We predict that a gradient of chemical composition “x” significantly lowers effective coercive fields of the compositionally graded AlN-Al 1-x Sc x N and ZnO-Zn 1-x Mg x O structures compared to the coercive fields of the corresponding multilayers with a uniform chemical composition in each layer. A tip-induced switching further lowers the coercive field, enabling control of ferroelectric domains in otherwise unswitchable compositionally graded structures, which can provide nanoscale domain control for memory, actuation, sensing, and optical applications.
Additive manufacturing of functionally graded transition joints between ferritic and austenitic alloys
Dissimilar metal joints between ferritic and austenitic alloys are susceptible to premature failure due to diffusive carbon loss from the ferritic alloy driven by abrupt changes in carbon chemical potential. Compositional grading of transition joints fabricated using laser-based directed energy deposition additive manufacturing offers a means for limiting carbon diffusion. In this report we fabricate functionally graded transition joints between a ferritic and austenitic alloy, characterize spatial variations of chemical composition, microstructure and hardness, and test their effectiveness to limit carbon loss from the ferritic alloy. Microstructural studies and carbon potential variations in the functionally graded material showed that the length of the joints can be shorter, and there is no benefit to continue compositional grading once the microstructure becomes fully austenitic. Since dissimilar joints have an expected lifetime of several decades, long service times were simulated through accelerated heat treatment experiments at elevated temperatures for both a dissimilar metal weld and a functionally graded transition joint. While the dissimilar weld showed pronounced carbon loss from the ferritic side, there was insignificant change in the carbon concentration profile in the functionally graded joint indicating effectiveness of the graded joints to perform under service conditions.
Compositionally graded Ga 1-x In x P buffers grown by static and dynamic hydride vapor phase epitaxy at rates up to 1 μm/min
Here, we demonstrate Ga 1-x In x P compositionally graded buffers (CGBs) grown on GaAs with lattice constants between GaAs and InP by hydride vapor phase epitaxy (HVPE). Growth rates were up to ~1 μm/min and threading dislocation density (TDD) was as low as 1.0 x 10 6 cm -2 . We studied the effect of substrate offcut direction, growth rate, and strain grading rate on CGB defect structure. We compared the effect of a “dynamic grading” style, which creates compositional interfaces via mechanical transfer of a substrate between two growth chambers, vs. “static grading” where the CGB grows in a single chamber. Dynamic grading yielded smoother grades with higher relaxation, but TDD was not significantly different between the two styles. Substrate offcut direction was the most important factor for obtaining CGBs with low defect density. (001) substrates offcut towards (111)B yielded smoother CGBs with lower TDD compared to CGBs grown on substrates offcut towards (111)A. Transmission electron microscopy of static and dynamic CGBs grown on A and B-offcuts only found evidence of phase separation in a static A-offcut CGB, indicating that the B offcut limits phase separation, which in turn keeps TDD low. Reduced growth rate led to the appearance CuPt-type atomic ordering, which affected the distribution of dislocations on the active glide planes but did not alter TDD. Higher growth rates led to smoother CGBs and did not appreciably increase TDD as otherwise predicted by steady-state models of plastic relaxation. These results show HVPE’s promise for lattice-mismatched applications and low-c ost InP virtual substrates on GaAs
Assessment of work-integrated learning: comparison of the usage of a grading rubric by supervising radiographers and teachers
Introduction: Professional work-integrated learning (WIL) that integrates the academic experience with off-campus professional experience placements is an integral part of many tertiary courses. Issues with the reliability and validity of assessment grades in these placements suggest that there is a need to strengthen the level of academic rigour of placements in these programmes. This study aims to compare the attitudes to the usage of assessment rubrics of radiographers supervising medical imaging students and teachers supervising pre-service teachers. Methods: WIL placement assessment practices in two programmes, pre-service teacher training (Avondale College of Higher Education, NSW) and medical diagnostic radiography (Faculty of Health Sciences, University of Sydney, NSW), were compared with a view to comparing assessment strategies across these two different educational domains. Educators (course coordinators) responsible for teaching professional development placements of teacher trainees and diagnostic radiography students developed a standards-based grading rubric designed to guide assessment of students’ work during WIL placement by assessors. After ∼12 months of implementation of the rubrics, assessors’ reaction to the effectiveness and usefulness of the grading rubric was determined using a specially created survey form. Data were collected over the period from March to June 2011. Quantitative and qualitative data found that assessors in both programmes considered the grading rubric to be a vital tool in the assessment process, though teacher supervisors were more positive about the benefits of its use than the radiographer supervisors. Results: Benefits of the grading rubric included accuracy and consistency of grading, ability to identify specific areas of desired development and facilitation of the provision of supervisor feedback. The use of assessment grading rubrics is of benefit to assessors in WIL placements from two very different teaching programmes. Conclusion: Radiographers appear to need more training in the rubric's use, whereas teachers are found to generally use it appropriately. There are implications drawn from this finding that are applicable to health science and medical education in general.
Influence of frequency, grade, moisture and temperature on Green River oil shale dielectric properties and electromagnetic heating processes
Development of in situ electromagnetic (EM) retorting technologies and design of specific EM well logging tools requires an understanding of various process parameters (applied frequency, mineral phases present, water content, organic content and temperature) on oil shale dielectric properties. In this literature review on oil shale dielectric properties, we found that at low temperatures (<200° C) and constant oil shale grade, both the relative dielectric constant (ε') and imaginary permittivity (ε'') decrease with increased frequency and remain constant at higher frequencies. At low temperature and constant frequency, ε' decreases or remains constant with oil shale grade, while ε'' increases or shows no trend with oil shale grade. At higher temperatures (>200º C) and constant frequency, epsilon' generally increases with temperature regardless of grade while ε'' fluctuates. At these temperatures, maximum values for both ε' and ε'' differ based upon oil shale grade. Formation fluids, mineral-bound water, and oil shale varve geometry also affect measured dielectric properties. This review presents and synthesizes prior work on the influence of applied frequency, oil shale grade, water, and temperature on the dielectric properties of oil shales that can aid in the future development of frequency- and temperature-specific in situ retorting technologies and oil shale grade assay tools.
Grading-System-Dependent Volume Effects for Late Radiation-Induced Rectal Toxicity After Curative Radiotherapy for Prostate Cancer
Purpose: To assess the association between the dose distributions in the rectum and late Radiation Therapy Oncology Group and the European Organisation for Research and Treatment of Cancer (RTOG/EORTC), Late Effects of Normal Tissue SOMA, and Common Terminology Criteria for Adverse Events (CTCAE) version 3.0 graded rectal toxicity among patients with prostate cancer treated with RT. Methods and Materials: Included in the study were 124 patients who received three-dimensional conformal RT for prostate cancer to a total dose of 70 Gy in 2-Gy fractions. All patients completed questionnaires regarding rectum complaints before RT and during long-term follow-up. Late rectum Grade 2 or worse toxicity, according to RTOG/EORTC, LENT SOMA, and CTCAE v3.0 criteria, was analyzed in relation to rectal dose and volume parameters. Results: Dose-volume thresholds (V40 {>=}65%, V50 {>=}55%, V65 {>=}45%, V70 {>=}20%, and a rectum volume {<=}140 cm{sup 3}), significantly discriminated patients with late Grade 0-1 and Grade 2 or worse rectal toxicity, particularly using the LENT SOMA and CTCAE v3.0 systems. The rectum volume receiving {>=}70 Gy (V70) was most predictive for late Grade 2 or worse rectal toxicity with each of the grading systems. The associations were strongest, however, with use of the LENT SOMA system. Conclusions: Volume effects for late radiation-induced rectal toxicity are present, but their clinical significance depends on the grading system used. This should be taken into account in the interpretation of studies reporting on radiation-induced rectal toxicity.