Search NASA⌕ Search

SEARCH · Search NASA

Results for “grating array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Pushing the Boundaries of X-ray Grating Spectroscopy in a Suborbital Rocket

Developments in grating spectroscopy are paramount for meeting the soft X‐ray science goals of future NASA X‐ray Observatories. While developments in the laboratory setting have verified the technical feasibility of using off‐plane reflection gratings to reach this goal, flight heritage is a key step in the development process toward large missions. To this end we have developed a design for a suborbital rocket payload employing an Off‐Plane X‐ray Grating Spectrometer. This spectrometer utilizes slumped glass Wolter‐1 optics, an array of gratings, and a CCD camera. We discuss the unique capabilities of this design, the expected performance, the science return, and the perceived impact to future missions.

McEntaffer, Randall L.↗

Large-scale cascading of first-order FBG array in a highly multimode coreless fiber using femtosecond laser for distributed thermal sensing

This research focuses on the performance analysis and characterization of a fiber Bragg gratings (FBGs) array, consisting of 10 first-order FBGs inscribed by a femtosecond (FS) laser in a highly multimode coreless fiber. The study evaluates the FBG array's ability to function as a distributed thermal sensing (DTS) platform, with the coreless fiber chosen as the sensing element due to its immunity to dopant migration at high temperatures. The design of a large cascaded first-order FBG array effectively eliminates unwanted harmonic peaks across a wide spectrum range. In contrast, higher-order FBGs introduce limitations due to the overlapping of Bragg peaks with harmonics. The FBG array's performance is evaluated by measuring the reflection spectrum of each grating at different temperatures, showing a high temperature sensitivity of 15.05 pm/°C at a Bragg wavelength of 1606.3 nm, with a linear response in the temperature range of 24 - 1100 °C. The FBG array was designed for a spatial resolution of 5 mm. A mode scrambler in the sensing network is employed, which suppresses multimodal interference, characterizes FBG peak visibility, and stabilizes the interference spectrum. The stability of the FBG array is also assessed over 24 hrs at 1100 °C, and it is observed to be stable during thermal treatment. Heat treatment at 1100°C improves the signal to noise ratio of the FBG array, demonstrating the robustness and suitability of the proposed FBG array on highly multimode coreless fiber as a potential sensing platform for DTS applications in harsh environmental conditions, overcoming the issues of dopant migration presented by dopes silica optical fibers at high temperatures.

47 OTHER INSTRUMENTATION↗

The optomechanical design for the Off-plane Grating Rocket Experiment (OGRE)

The Off-plane Grating Rocket Experiment (OGRE) is a sounding rocket payload designed to obtain a high-resolution soft X-ray spectrum of Capella. OGRE’s optical system uses new technologies including state-of-the-art X-ray optics, custom arrays of reflection gratings, and an array of EM-CCDs. Many of these technologies will be tested for the first time in flight with OGRE. To achieve the high performance that these new technologies are capable of, the payload components must be properly aligned to meet high tolerances. This paper will outline OGRE’s opto-mechanical design for achieving alignment within these tolerances. Specifically, the design of the X-ray grating arrays will be discussed.

Bridget C. O’Meara↗

Ultrafast Annealing Improves SNR and Long-Term Stability of a Highly Multiplexed Line-by-Line FBG Array Inscribed by Femtosecond Laser in a Coreless Fiber for Extreme-Temperature Applications

This study reports the fabrication of a fourth-order line-by-line fiber Bragg grating (FBG) array using femtosecond laser inscription within a highly multimode coreless optical fiber, with a particular focus on achieving substantial multiplexing capabilities. An ultrafast annealing procedure is employed, resulting in an impressive enhancement of the FBG sensor’s fringe visibility by approximately 13 dB, signifying a notable improvement of approximately ~4 dB. This substantial enhancement contributes to the long-term stability and performance of the multiplexed FBG array in extreme-temperature conditions. The systematic fabrication approach employed for the multiplexed FBG array guarantees a high signal-to-noise ratio (SNR) for each individual FBG within the array. This FBG array is intended for extreme-temperature applications, addressing limitations associated with traditional FBGs based on doped optical fibers, including SNR degradation and temperature-induced fringe drift. Testing at temperatures up to 1120 °C demonstrates the FBG array’s stability without fluctuations in readings. Furthermore, it endures seven heat cycles, spanning from 500 °C to 1120 °C, over 60 h, exhibiting outstanding thermal stability. Furthermore, this highly multiplexed FBG array with an ultrafast annealing approach holds promise for extreme-temperature environments, such as steelmaking, where precise and reliable distributed temperature monitoring is imperative.

47 OTHER INSTRUMENTATION↗

The high energy transmission grating spectrometer for AXAF

Attention is given to a high energy transmission grating spectrometer that operates over the range 0.4-8 keV, giving resolving powers of 100-1000 and effective areas of 10-200 sq cm. The instrument, which is part of the MIT high resolution X-ray spectroscopy investigation, consists of a single array of grating facets of two types: medium energy gratings of 0.6-micron period, 0.5-micron thick silver mounted behind the outer three AXAF mirrors, and high energy gratings of 0.2-micron period, 1.0-micron thick gold mounted behind the inner three mirrors. The gratings are oriented so as to correct for coma and so that the medium and high energy spectra form a shallow 'X' at the AXAF focal plane. Likely targets include normal stars, binary X-ray sources, active galactic nuclei and quasars. The HETGS can also be used to give moderate resolution spectra of slightly extended sources and monochromatic images of sources with strong lines, such as supernova remnants in nearby galaxies.

Canizares, C. R.↗

Compact Two-Dimensional Spectrometer Optics

The figure is a simplified depiction of a proposed spectrometer optical unit that would be suitable for incorporation into a remote-sensing instrumentation system. Relative to prior spectrometer optical assemblies, this unit would be compact and simple, largely by virtue of its predominantly two-dimensional character. The proposed unit would be a combination of two optical components. One component would be an arrayed-waveguide grating (AWG) an integrated-optics device, developed for use in wavelength multiplexing in telecommunications. The other component would be a diffraction grating superimposed on part of the AWG. The function of an AWG is conceptually simple. Input light propagates along a single-mode optical waveguide to a point where it is split to propagate along some number (N) of side-by-side waveguides. The lengths of the optical paths along these waveguides differ such that, considering the paths in a sequence proceeding across the array of waveguides, the path length increases linearly. These waveguides launch quasi-free-space waves into a planar waveguide-coupling region. The waves propagate through this region to interfere onto an array of output waveguides. Through proper choice of key design parameters (waveguide lengths, size and shape of the waveguide coupling region, and lateral distances between waveguides), one can cause the input light to be channeled into wavelength bins nominally corresponding to the output waveguides.

Hong, John↗

The AXAF CCD imaging spectrometer

The AXAF CCD Imaging Spectrometer (ACIS) is currently being defined as a possible focal plane instrument to be flown on the Advanced X-ray Astrophysics Facility (AXAF). The imaging spectrometer consists of an array of charge coupled devices (CCD's) to be placed at the focus of the AXAF mirrors. The array will provide high angular resolution (0.5 arc seconds), moderate spectral resolution (150 eV) over the energy range 0.1 to 10 keV, temporal resolution down to 60 microseconds, and single photon quantum detection efficiencies of up to 90 percent. X-ray sensitivity for a point source exceeds 10 to the -15th ergs/sq cm sec for a 10 to the 5th sec exposure. When used in conjunction with the objective gratings, the array will yield wavelength resolution of up to 200.

Garmire, G. P.↗

X-ray wavefront sensor development at the Advanced Light Source

At Lawrence Berkeley National Laboratory's Advanced Light Source, we are developing x-ray wavefront sensors to support the creation and operation of beamlines with diffraction-limited quality. Our new approach to rapid, intermittent wavefront sensing operates in reflection at glancing incidence angles and is compatible with the high-power densities of modern beamlines. For soft x-ray applications especially, the wavefront sensor can operate upstream of the exit slit in a vertically dispersed beam. This single-shot technique supports lateral shearing interferometry and Hartmann wavefront sensing; it can be adapted to speckle-based techniques as well. The reflected beam is directed to an off-axis YAG crystal that produces scintillated visible light. A small mirror reflects the light to a microscope and camera, and the measured wavefront shape information can be used as feedback to adaptive x-ray mirror elements. A compact array of gratings enables measurement across a broad range of photon energies or wavefront curvatures. We describe recent demonstrations at soft x-ray and hard x-ray wavelengths measuring an adaptive x-ray mirror, and a toroidal focusing mirror.

Goldberg, Kenneth A↗

INTREPID program: technology and architecture for next-generation, energy-efficient, hyper-scale data centers [Invited]

The INTREPID program is developing power-efficient coherent optics for package-level integration with future switch integrated circuits as a path to realizing higher-radix switches for flatter networks. The link architecture is underpinned by coherent quadrature phase-shift keying (QPSK) polarization-multiplex transceivers at 200 Gb/s per λ <#comment/> , further enhanced with wavelength division multiplexing (WDM) to enable energy-efficient 800 or 1600 Gb/s inter-switch fiber connections. The technology is compatible with conventional three-level data center designs as well as a two-level data center design introduced here, which includes an added layer of passive, arrayed waveguide grating routers (AWGRs) or WDM circuit switches to further improve the cost, energy efficiency, and latency of the network.

Saleh, Adel A. M. (ORCID:0000000182451136)↗

Development of Optical Fiber-Based Sensors for Nuclear Microreactor Structural Health Monitoring

This report provides an experimental assessment of two different optical fiber–based acoustic sensors that are being investigated for application in nuclear microreactors to enhance structural health monitoring capabilities. Optical fibers are resilient in high-temperature and high-radiation environments, have a small sensor footprint, are immune to electromagnetic interference, and are capable of spatially distributed sensing. The two sensors investigated here are (1) Fabry–Pérot Cavities (FPCs) between two copper-coated fibers, embedded in nickel capillary tubes and (2) type-I fiber Bragg grating (FBG) arrays contained within metal capillary tubes. These sensors can be interrogated using low-coherence interferometry or swept wavelength interferometry, respectively, to measure the resonant frequencies of the components or systems to which these sensors are bonded. The FPC developed herein has been subjected to temperatures up to nearly 800°C while tack-welded to a tubular test specimen. Even at the highest temperatures, the measured resonant frequencies compared well with those obtained using an accelerometer that was bonded to an unheated portion of the specimen. The FBG array was tested in multiple bonding configurations to a tubular test specimen, all at room temperature, with the understanding that high temperature (i.e., type II) FBGs could be used to obtain similar data at high temperatures; the FBG array data were validated with noncontact laser vibrometry, which is being used at Los Alamos National Laboratory to relate acoustic signatures to component stresses and/or structural defects. The goal of this work is to identify the most promising techniques that are also compatible with operation in a microreactor environment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Laser-Induced Incandescence Calibration via Gravimetric Sampling

Various beam imaging and/or sheet forming optics delivered light at 1064 nm from a pulsed Nd:YAG laser for use either as a beam of 3 mm radius or as a laser sheet. Imaging measurements were performed with a grated intensified array camera equipped with an ultraviolet f4.5 lens and a 40 mm extension tube. Point measurements were performed using an ultraviolet 250 mm focal length lens to collect and focus the laser induced incandescence (LII) signal into a 1 meter long quartz optical fiber which directed the LII signal to a 1/4 meter monochromator. An aperture preceding the lens restricted the signal collection region to 1 cm along the laser beam at the center of the gravimetric chimney. Signals from the PMT were processed by a boxcar integrator whereas the images were captured digitally using a frame-grabber with 16 MByte of on-board memory. Both 'point' and planar measurements were made with detector gates of 250 ns to minimize possible morphology bias in collection of the LII signal. Additionally, the imaging measurements were performed with broadband spectral collection of the LII signal to maximize the signal and again minimize any potential effects of morphology dependent heating and/or cooling rates. Digital delay generators controlled the firing of he laser, detector gates and data acquisition. Neutral density filters were used for both sets of measurements to maintain signal levels within linear dynamic ranges of the detectors, the range being determined prior to experiments.

VanderWal, R. L.↗

Level-1C Product from AIRS: Principal Component Filtering

The Atmospheric Infrared Sounder (AIRS), launched on the EOS Aqua spacecraft on May 4, 2002, is a grating spectrometer with 2378 channels in the range 3.7 to 15.4 microns. In a grating spectrometer each individual radiance measurement is largely independent of all others. Most measurements are extremely accurate and have very low noise levels. However, some channels exhibit high noise levels or other anomalous behavior, complicating applications needing radiances throughout a band, such as cross-calibration with other instruments and regression retrieval algorithms. The AIRS Level-1C product is similar to Level-1B but with instrument artifacts removed. This paper focuses on the "cleaning" portion of Level-1C, which identifies bad radiance values within spectra and produces substitute radiances using redundant information from other channels. The substitution is done in two passes, first with a simple combination of values from neighboring channels, then with principal components. After results of the substitution are shown, differences between principal component reconstructed values and observed radiances are used to investigate detailed noise characteristics and spatial misalignment in other channels.

Noise Equivalent delta Temperature (NEdT)↗

Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE)

The mid-infrared (MIR) spectral range (3-5 μm) is of particular interest for remotely sensing gaseous molecules such as H2O, CO2, CH4, N2O, CO, NH3, and other compounds. The infrared spectra of planets, moons, comets, and asteroids are rich in information, including gas composition and surface mineralogy. Significant advances in technology have emerged for ground-based telescopes, including the higher spectral resolution permitted by cross-dispersed instruments and heterodyne techniques. New technologies offer the opportunity to break this barrier, by using solid- state photonics. In the past three years, under the NASA ROSES PICASSO program, we have been developing key components for a revolutionary MIR spectrometer: Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE), which is based on integrated photonics technology that offers ultra-small size, weight, and power (SWaP) with non-moving parts and low cost for future planetary missions. In this paper, we will describe our science and technology development progress leading to demonstrating the concept and functionalities of the PICTURE instrument. The photonic integrated circuit spectrometer (PICS) of the PICTURE instrument uses an integrated heterodyne detection scheme to significantly reduce SWaP and improve sensitivity. Our program goals are to advance the building blocks needed for the PICS, which include arrayed waveguide gratings (AWGs), quantum cascade lasers (QCLs) as local oscillators, and quantum cascade detectors (QCDs) as heterodyne detectors. In addition, we are leveraging a NASA SBIR program to develop the toolsets needed to fabricate MIR photonics lanterns (PL). The PL is a critical component that enables PICTURE to bring a signal from the collecting telescope to the PICS, which requires single optical mode inputs. PICTURE focuses on the CO spectral band at 4.6-4.8 μm that is of key importance to cometary science. We also continue to explore future instrument concepts that exploit the broad wavelength potential of the PICS design to perform spectroscopy spanning the full MIR and longwave IR (LWIR) bands. This will have wide applicability in planetary science, for example, to probe the strongest CO2, H2O, and CH4 transitions that are difficult (CH4) or impossible (CO2, H2O) to detect using Earth-based telescopes due to atmospheric opacity. Each integrated-photonics-spectrometer chip will feature a single heterodyne room-temperature laser with a wide wavelength tuning range, or multiple local-oscillator lasers for much broader spectral coverage. The fully developed PICTURE instrument will provide a cost-effective, high-resolution spectrometer for future space applications.

Anthony W Yu↗

Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE)

The mid-infrared (MIR) spectral range (3-5 μm) is of particular interest for remotely sensing gaseous molecules such as H2O, CO2, CH4, N2O, CO, NH3, and other compounds. The infrared spectra of planets, moons, comets, and asteroids are rich in information, including gas composition and surface mineralogy. Significant advances in technology have emerged for ground-based telescopes, including the higher spectral resolution permitted by cross-dispersed instruments and heterodyne techniques. New technologies offer the opportunity to break this barrier, by using solid-state photonics. In the past three years, under the NASA ROSES PICASSO program, we have been developing key components for a revolutionary MIR spectrometer: Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE), which is based on integrated photonics technology that offers ultra-small size, weight, and power (SWaP) with non-moving parts and low cost for future planetary missions. In this paper, we will describe our science and technology development progress leading to demonstrating the concept and functionalities of the PICTURE instrument. The photonic integrated circuit spectrometer (PICS) of the PICTURE instrument uses an integrated heterodyne detection scheme to significantly reduce SWaP and improve sensitivity. Our program goals are to advance the building blocks needed for the PICS, which include arrayed waveguide gratings (AWGs), quantum cascade lasers (QCLs) as local oscillators, and quantum cascade detectors (QCDs) as heterodyne detectors. In addition, we are leveraging a NASA SBIR program to develop the toolsets needed to fabricate MIR photonics lanterns (PL). The PL is a critical component that enables PICTURE to bring a signal from the collecting telescope to the PICS, which requires single optical mode inputs. PICTURE focuses on the CO spectral band at 4.6-4.8 μm that is of key importance to cometary science. We also continue to explore future instrument concepts that exploit the broad wavelength potential of the PICS design to perform spectroscopy spanning the full MIR and longwave IR (LWIR) bands. This will have wide applicability in planetary science, for example, to probe the strongest CO2, H2O, and CH4 transitions that are difficult (CH4) or impossible (CO2, H2O) to detect using Earth-based telescopes due to atmospheric opacity. Each integrated-photonics-spectrometer chip will feature a single heterodyne room-temperature laser with a wide wavelength tuning range, or multiple local-oscillator lasers for much broader spectral coverage. The fully developed PICTURE instrument will provide a cost-effective, high-resolution spectrometer for future space applications.

Anthony W Yu↗

Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE)

The mid-infrared (MIR) spectral range (3-5 μm) is of particular interest for remotely sensing gaseous molecules such as H2O, CO2, CH4, N2O, CO, NH3, and other compounds. The infrared spectra of planets, moons, comets, and asteroids are rich in information, including gas composition and surface mineralogy. Significant advances in technology have emerged for ground-based telescopes, including the higher spectral resolution permitted by cross-dispersed instruments and heterodyne techniques. New technologies offer the opportunity to break this barrier, by using solid-state photonics. In the past three years, under the NASA ROSES PICASSO program, we have been developing key components for a revolutionary MIR spectrometer: Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE), which is based on integrated photonics technology that offers ultra-small size, weight, and power (SWaP) with non-moving parts and low cost for future planetary missions. In this paper, we will describe our science and technology development progress leading to demonstrating the concept and functionalities of the PICTURE instrument. The photonic integrated circuit spectrometer (PICS) of the PICTURE instrument uses an integrated heterodyne detection scheme to significantly reduce SWaP and improve sensitivity. Our program goals are to advance the building blocks needed for the PICS, which include arrayed waveguide gratings (AWGs), quantum cascade lasers (QCLs) as local oscillators, and quantum cascade detectors (QCDs) as heterodyne detectors. In addition, we are leveraging a NASA SBIR program to develop the toolsets needed to fabricate MIR photonics lanterns (PL). The PL is a critical component that enables PICTURE to bring a signal from the collecting telescope to the PICS, which requires single optical mode inputs. PICTURE focuses on the CO spectral band at 4.6-4.8 μm that is of key importance to cometary science. We also continue to explore future instrument concepts that exploit the broad wavelength potential of the PICS design to perform spectroscopy spanning the full MIR and longwave IR (LWIR) bands. This will have wide applicability in planetary science, for example, to probe the strongest CO2, H2O, and CH4 transitions that are difficult (CH4) or impossible (CO2, H2O) to detect using Earth-based telescopes due to atmospheric opacity. Each integrated-photonics-spectrometer chip will feature a single heterodyne room-temperature laser with a wide wavelength tuning range, or multiple local-oscillator lasers for much broader spectral coverage. The fully developed PICTURE instrument will provide a cost-effective, high-resolution spectrometer for future space applications.

Anthony W. Yu↗

High density optical waveguide using hybrid spiral pattern

A hybrid spiral waveguide geometry is proposed that exhibits essentially zero curvature (i.e., infinite bend radius) at the center of the spiral (similar to a Fermat spiral), with the curvature then increasing in value as the spiral moves outward. Advantageously, as the spiral moves away from the center, the spacing between adjacent waveguides quickly approaches a constant value (similar to an Archimedean spiral). This hybrid spiral structure has been found to allow for a high density waveguide to be created with lower loss and requiring a smaller size than many conventional spiral configurations and finds use in optical delay lines, amplifiers and arrayed waveguide gratings.

42 ENGINEERING↗

Optical design of Lyman/FUSE

The optical system for the proposed Lyman/Far UV Spectroscopic Explorer (FUSE) orbiting observatory is described and illustrated with drawings and graphs of predicted performance. The system comprises (1) an FUV channel based on a 1.84-m-diameter Rowland circle spectrograph with five high-density modified ellipsiodal near-normal-incidence gratings and an array of four MAMA detectors; (2) an EUV channel with ellipsoidal mirror, planar varied-line-space grating, microchannel-plate array, and wedge-and-strip anode detector; (3) a 70-cm Wolter II glancing-incidence telescope; and (4) a CCD-detector fine-error sensor to provide accurate pointing (within 200 marcsec rms). The resolving powers of the spectrographs are 30,000 in the FUV and 300-600 (wavelength-dependent) in the EUV.

Content, D. A.↗