Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Toward 100% Renewable Power Grids: A Review

The transition to a 100% renewable power grid remains beset by significant technical challenges. This paper critically examines the obstacles arising from the variability and unpredictability of renewable energy sources (RES), which complicate the real-time balancing of power generation and load demand. In addition to traditional stability concerns (e.g., rotor angle, voltage, and frequency stability), the increasing penetration of inverter-based resources (IBRs) introduces novel challenges, including resonance stability issues and converter-driven dynamics. Moreover, the dynamic behavior and fault response of IBRs diverge markedly from those of conventional synchronous generators, rendering traditional protection schemes increasingly inadequate. This paper reviews state-of-the-art solutions in power balancing, grid flexibility, stability enhancement, and advanced protection strategies, discussing their implications for future grid design. The analysis provides a comprehensive assessment of recent technological advancements, thereby outlining critical research directions essential for achieving a resilient, 100% renewable power grid.

100% renewable power grid↗

Resource Adequacy in Decarbonizing Power Systems

Decarbonization of the power sector is instrumental to reducing emissions worldwide. Following the 13th Clean Energy Ministerial conference (CEM13) in 2022, several governments signaled their intention to develop power sector decarbonization action plans. The 21st Century Power Partnership (21CPP), in coordination with all Clean Energy Ministerial power workstreams and collaborators, is providing technical support on critical focus areas as these countries prepare their action plans. Countries will present the action plans at the upcoming CEM14 in India. Brought to you by the Clean Energy Solutions Center and 21CPP, this webinar will focus on resource adequacy and grid flexibility, key themes in the CEM14 action plans and critical topics for integrating variable renewable energy into the grid while ensuring system reliability. Global energy experts will discuss how grid planners can ensure stable supply while rapidly decarbonizing the power system and how various policies can increase the power grid's flexibility.

emissions↗

An overview of controls research on the NASA Langley Research Center grid

The NASA Langley Research Center has assembled a flexible grid on which control systems research can be accomplished on a two-dimensional structure that has many physically distributed sensors and actuators. The grid is a rectangular planar structure that is suspended by two cables attached to one edge so that out of plane vibrations are normal to gravity. There are six torque wheel actuators mounted to it so that torque is produced in the grid plane. Also, there are six rate gyros mounted to sense angular motion in the grid plane and eight accelerometers that measure linear acceleration normal to the grid plane. All components can be relocated to meet specific control system test requirements. Digital, analog, and hybrid control systems capability is provided in the apparatus. To date, research on this grid has been conducted in the areas of system and parameter identification, model estimation, distributed modal control, hierarchical adaptive control, and advanced redundancy management algorithms. The presentation overviews each technique and presents the most significant results generated for each area.

Montgomery, Raymond C.↗

Representing the Future Role of Hydropower and Pumped Storage Hydropower (PSH) in Electricity Planning Tools

Existing tools for long-term electric sector planning struggle to represent hydropower's nuanced site-specific technical and operating characteristics, which depend on technical specifications as well as water management practices and regulations. As a result, long-term planning models and tools insufficiently characterize hydropower value and incentives, and they cannot fully represent the role hydropower can play in a future electricity system that could include a high penetration of variable wind and solar generation, battery storage, and other low-carbon technologies. This presentation demonstrates the culmination of a multi-year effort to enhance hydropower representations in electricity planning models at the National Renewable Energy Laboratory (NREL), as part of the U.S. Department of Energy (USDOE) HydroWIRES Initiative. New modeling techniques are demonstrated using the NREL Regional Energy Deployment System (ReEDS), an open-access electric sector capacity expansion model used extensively in a wide range of technology deployment and integration analysis, including the 2016 USDOE Hydropower Vision. ReEDS uses a least-cost optimization approach to understand investment and operation of electricity generation, storage, and transmission technologies under future scenarios of electricity technology innovation, demand, policy, and other sectoral drivers. ReEDS was modified to better represent value and opportunities for both pumped storage hydropower (PSH) and hydropower systems without pumping. We incorporated a new national closed-loop PSH resource and cost assessment to explore new PSH deployment opportunities and added plant-level data to better represent the existing PSH fleet. New upgrade pathways enable opportunities for enhanced hydropower flexibility by adding pumps, upgrading dispatchability, increasing capacity, or increasing energy availability. The model was also modified to better represent the value of long-duration energy storage beyond diurnal time scales, allowing both hydropower and PSH to better balance energy supply and demand variations in high-renewable systems. These new features are demonstrated under reference and high-renewable futures and a range of sensitivity scenarios to understand which hydropower and PSH deployment and upgrade opportunities are the most attractive. These scenarios indicate potential for new closed-loop PSH deployment and for hydropower flexibility improvements to have important impacts on long-term electricity system emissions and economic outcomes. Increasing flexibility of the existing hydropower fleet can reduce the need to invest in new flexible grid technologies and help achieve decarbonization goals. Systems with sufficient energy storage could also be valuable for balancing seasonal differences in renewable energy availability, particularly from solar energy. The methods developed for ReEDS and subsequent scenario results reveal important considerations for future hydropower and grid system planning, and all data and code is freely available in a public code repository for use throughout the hydropower industry.

capacity expansion↗

Opportunities for Industry to Provide Flexibility While Increasing Profitability

Supply and demand flexibility will both be needed to ensure the electricity system functions properly as the share from variable renewable generation continues to grow. Industrial manufacturing currently consumes about a third of primary energy worldwide, and electricity is projected to supply an increasing share of this demand as the global economy decarbonizes. Therefore, the ability for industry to flex demand poses an enticing opportunity to enable grid flexibility. However, large capital outlays prevent industry from voluntarily altering demand. Here we show that as battery costs continue to fall, industry will soon be able to profitably alter demand in accordance with electricity price variations. Focusing on two established industries– chlor-alkali and electric arc furnaces – and two industries with large future potential – methane pyrolysis and atmospheric CO 2 capture, we use a linear program (LP) optimization to assess the technoeconomic feasibility of flexible industrial demand across both historical and future-looking wholesale day-ahead marginal prices for the Electricity Reliability Council of Texas (ERCOT). We find positive net present values (NPV) from $\$$400K to $\$$50M using projected 2050 battery prices for industrial purchase of behind-the-meter batteries, using only arbitrage as a source of value. These results indicate that, with projected battery prices, profit-seeking industrial players could voluntarily play a future role in stabilizing a high-renewables grid where electricity prices act as accurate signals of grid needs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Final Technical Report of a Feasibility Investigation of a Hydropower Flexibility Upgrade Kit

The project studied the feasibility of a concept for a flexibility upgrade kit called h-Dynamyk to improve the flexibility of U.S. hydropower plants and assessed its potential impact on the U.S. hydropower industry. This concept addresses the growing need for grid flexibility amid rising renewable energy adoption, such as wind and solar, which often introduce intermittency. The upgrade kit is intended to address challenges posed by aging turbine designs in meeting modern grid demands for flexibility services like frequency response, voltage control, spinning reserve, and black-start capabilities. Key features of the h-Dynamyk kit include siphon turbine assemblies, medium-voltage variable frequency drives (VFDs), and smart controls integrated with plant systems to optimize operations and extend equipment life. This nine-month discovery project successfully achieved its objectives by defining a baseline design and performance metrics for the h-Dynamyk flexibility upgrade kit, analyzing this baseline, and incorporating lessons learned from this analysis into a modified set of metrics and recommendations for future design and testing, which were further guided by field site studies.

13 HYDRO ENERGY↗

Evaluation of smart charging for electric vehicle-to-building integration: A case study

Higher electric vehicle (EV) adoption will stress the importance of demand flexibility to achieve more economic, efficient, and reliable grid operation. Charging technologies will be paramount in shifting temporally to better fit the variable generation of wind and solar. As such, analysis is warranted on the benefits of EV charge scheduling with respect to installation cost, operation cost, difficulty of implementation, and grid flexibility. We tackle this by analyzing the cost savings of implementing an EV charge scheduling infrastructure to reduce demand charges and installation costs. In this paper, we analyze a case study for operation of 16 level 2 chargers and 1 fast charger for two different building types. We then evaluate various test phases for controlling building and charging loads using an adaptive charging network (ACN) algorithm to characterize the ACN’s potential to reduce overall project cost.

30 DIRECT ENERGY CONVERSION↗

Distribution System State Estimation With High Penetration of Demand Response Enabled Loads

Demand-side operations incentivize utility customers to take part in various grid services. A demand response enabled load (DREL) is a flexible grid asset that schedules electricity consumption in response to a time-of-use (TOU) energy price. Consequently, its energy profile differs from that of a conventional load that is insensitive to price. This difference may cause new challenges for distribution system state estimation (DSSE). It is well known that DSSE often needs to use pseudo-measurements based on historic load profiles to increase system observability. However, historic profiles of conventional loads are not representative of DREL behaviors. Additionally, the inaccuracy impacts DSSE results and other DSSE-dependent operations. In this paper, we propose an online pseudo-measurement generation approach for DSSE with DRELs. We formulate an optimization model to represent DRELs self-adjusting actions. Sampling-based stochastic optimization techniques are proposed to account for uncertainties in DRELs. A set of representative DREL behavior data corresponding to the samples are used to characterize DREL pseudo-measurements. Case studies with modified IEEE 123-bus test system verify the validity of the proposed work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Commercial and Residential Hourly Load Profiles for All Typical Meteorological Year 3 (TMY3) Locations in the United States

One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, it is critical to understand how and when energy is used. High-quality end-use load profiles (EULPs) provide this information and can help cities, states, and utilities understand the time-sensitive value of energy efficiency, demand response, and distributed energy resources. Publicly available EULPs have traditionally had limited application because of age and incomplete geographic representation. To help fill this gap, the U.S. Department of Energy funded a 3-year project, End-Use Load Profiles for the U.S. Building Stock, that culminated in this publicly available dataset of calibrated and validated 15-minute-resolution load profiles for all major residential and commercial building types and end uses across all climate regions in the United States. These EULPs were created by calibrating the ResStock and ComStock physics-based building stock models using many different measured datasets, as described in the "Technical Report Documenting Methodology" linked in the submission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing and Evaluating Metrics for Demand Flexibility in Buildings: Comparing Simulations and Field Data

Building demand flexibility (DF) has attracted significant attention in recent years among researchers, technology developers and control companies, aggregators, utilities, and many others. There are numerous challenges with today’s electricity systems such as managing peak demand capacity and integrating variable renewables into the grid. Flexible building loads can provide various grid services to help reduce electricity costs, smooth out renewables intermittency and balance supply and demand. Recognizing this, the US DOE is leading the Grid-interactive Efficient Buildings (GEB) initiative which includes research to evaluate the potential, availability and timing of flexible loads. In this paper we present load shed metrics for three building types – medium office, large office and retail store – and compare prototype simulation results with measured data from 12 actual buildings that participated in hot summertime utility demand response (DR) events. The DR strategies included varying zone temperature and reducing light levels. The magnitude of a key DF metric, “demand decrease intensity” (or “shed intensity”) (W/ft2), between the simulation results and field data are similar (14-32% differences) for both mean and median values, though the field data show much larger variation among DR events. The coefficient p-values from linear regression model tests showed that outside air temperature is a significant variable for the whole building shed intensity when the resetting zone temperature strategy is deployed. These findings support the concept of using prototype building simulation to estimate building DF and expanding future simulation research to additional building types and climate zones.

Liu, Jingjing↗

Grid Planning Impacts of Hydropower Growth and Decline

Hydropower and pumped storage hydropower (PSH) have a complex and uncertain future in the U.S. electricity system. On one hand, existing assets have the potential for an expanded role in integrating variable renewable energy while new deployment, particularly of PSH, can help meet growing needs for grid flexibility and improved reliability. On the other hand, challenging environmental and cost considerations could limit the extent of new investments in hydropower and PSH capacity and flexibility. This technical presentation demonstrates the use of a high-fidelity capacity expansion model of the U.S. electric grid (the National Renewable Energy Laboratory's Regional Energy Deployment System) to understand the impacts of alternative futures for the hydropower and PSH fleet, including scenarios of both growth and decline. Growth scenarios include new PSH deployment or improved hydropower flexibility, while scenarios of decline reduce the capacity or energy production potential of hydropower and PSH. Economic, environmental, and performance outcomes of the grid are compared across these scenarios to reveal the potential contributions of hydropower and PSH in the U.S. electric sector over the next several decades, focusing on changes to the grid technology mix, electric sector costs, electricity prices, and air emissions. This broad scenario approach demonstrates how flexible hydropower and PSH can help reduce air emissions and cost by complementing variable renewables, but the opposite can occur with reduced hydropower availability, particularly in the next decade. It is important to consider a wide range of scenarios and metrics to gain a national and regional understanding of hydropower's future in the United States.

capacity expansion↗

Model predictive control for demand flexibility: Real-world operation of a commercial building with photovoltaic and battery systems

Hundreds of studies have investigated Model Predictive Control (MPC) for the optimal operation of building energy systems in the past two decades. However, MPC field tests are still uncommon, especially for small- and medium-sized commercial buildings and for buildings integrated with onsite renewables. This paper describes the implementation and the long-term performance evaluation of an MPC controller in a small commercial building equipped with behind-the-meter photovoltaics and electrochemical batteries. MPC controls space conditioning, commercial refrigeration, and the battery system. We tested two types of demand flexibility applications in the field: electricity bill minimization under time-of-use tariffs and responses to grid flexibility events. Results show that the proposed controller achieves 12% of annual electricity cost savings and 34% peak demand reduction against the baseline, while respecting thermal comfort and food safety. The field tests also demonstrate the ability of the MPC controller to provide a multitude of grid services including real-time pricing, demand limiting, load shedding, load shifting, and load tracking, using the same optimization framework.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Unstructured viscous grid generation by advancing-front method

A new method of generating unstructured triangular/tetrahedral grids with high-aspect-ratio cells is proposed. The method is based on new grid-marching strategy referred to as 'advancing-layers' for construction of highly stretched cells in the boundary layer and the conventional advancing-front technique for generation of regular, equilateral cells in the inviscid-flow region. Unlike the existing semi-structured viscous grid generation techniques, the new procedure relies on a totally unstructured advancing-front grid strategy resulting in a substantially enhanced grid flexibility and efficiency. The method is conceptually simple but powerful, capable of producing high quality viscous grids for complex configurations with ease. A number of two-dimensional, triangular grids are presented to demonstrate the methodology. The basic elements of the method, however, have been primarily designed with three-dimensional problems in mind, making it extendible for tetrahedral, viscous grid generation.

Pirzadeh, Shahyar↗

Unstructured viscous grid generation by advancing-layers method

A new method of generating unstructured triangular/tetrahedral grids with high-aspect-ratio cells is proposed. The method is based on new grid-marching strategy referred to as 'advancing-layers' for construction of highly stretched cells in the boundary layer and the conventional advancing-front technique for generation of regular, equilateral cells in the inviscid-flow region. Unlike the existing semi-structured viscous grid generation techniques, the new procedure relies on a totally unstructured advancing-front grid strategy resulting in a substantially enhanced grid flexibility and efficiency. The method is conceptually simple but powerful, capable of producing high quality viscous grids for complex configurations with ease. A number of two-dimensional, triangular grids are presented to demonstrate the methodology. The basic elements of the method, however, have been primarily designed with three-dimensional problems in mind, making it extendible for tetrahedral, viscous grid generation.

Pirzadeh, Shahyar↗

Ion accelerator system mounting design and operating characteristics for a 5 kW 30-cm xenon ion engine

Results from a series of experiments to determine the effect of accelerator grid mount geometry on the performance of the J-series ion optics assembly are described. Three mounting schemes, two flexible and one rigid, are compared for their relative ion extraction capability over a range of total accelerating voltages. The largest ion beam current, for the maximum total voltage investigated, is shown to occur using one of the flexible grid mounting geometries. However, at lower total voltages and reduced engine input power levels, the original rigid J-series ion optics accelerator grid mounts result in marginally better grid system performance at the same cold interelectrode gap.

Aston, Graeme↗