Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

Phasor Measurement Units (PMUs) are critical for the Wide Area Measurement System (WAMS), especially for real-time grid monitoring, disturbance location, and situation awareness. Once they are damaged, the stable operation of the power system will be affected directly and greatly. Therefore, it is urgent and necessary to study their immunity to electromagnetic pulse (EMP) events. In this paper, an effective impedance measurement scheme is proposed for port impedance measurement of PMU. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then circuit of pulsed current generator is established to generate damping sinusoid and double exponential wave applied to the port. Finally, by using measured impedance as a load of the generator, the voltage and current responses of different ports are calculated in the pulsed current injection (PCI) testing simulation. Results show that common-mode impedance is large and differential mode impedance is small. The critical condition will appear in the common mode for voltage and differential mode for current.

Zhang, Liang↗

Convolutional Variational Autoencoder-based Unsupervised Learning for Power Systems Faults

Classification of power system event data is a growing need, particularly where non-protective relaying-based sensors are used to monitor grid performance. Given the high burden of obtaining event data with appropriate labeling, an unsupervised approach is highly valuable. This approach enables using event data without labeling, which is far easier to obtain. This paper presents an unsupervised learning method to classify and label transients observed in the distribution grid. A Convolutional Variational Autoencoder (CVAE) was developed for this purpose. We demonstrate the efficacy of our approach using the transient data generated from the simulations. The simulation data is used to train the CVAE that identifies different faults as different clusters in the latent space. The clusters are then used as the foundation model to categorize the real-world data.

Alam, Maksudul↗

Characterization and equalization of intensity-modulated voltage sensors

We test fiber-optic voltage sensors based on reflection from a piezoelectric transducer. Detailed characterization confirms a 60 dB dynamic range, and our equalization approach accurately recovers transient excitations, indicating the versatility of this sensor design in electric grid monitoring.

Lukens, Joseph↗

Equalization of Intensity-Modulated Fiber-Optic Voltage Sensors for Power Distribution Systems

We test fiber-optic voltage sensors based on optical reflection from a piezoelectric transducer. Our specific devices possess a 2 kHz fundamental resonance, and we verify a readily usable frequency band from approximately 10 Hz to 3 kHz, with a dynamic range of 60 dB for a detection system integrating over this entire band. Additionally, we demonstrate a digital signal processing approach to equalize the measured frequency response, enabling accurate retrieval of short-pulse inputs. These results suggest the value and applicability of intensity-modulated fiber-optic voltage sensors for measuring both steady-state waveforms and broadband transients which, coupled with the straightforward and compact design of the sensors, should make them effective tools in electric grid monitoring.

42 ENGINEERING↗

A New Multi-Scale State Estimation Framework for the Next Generation of Power Grid EMS

Accurate system state information under various operation conditions is a prerequisite for power grid monitoring and efficient control. To achieve that goal, a new multi-scale state estimation framework is proposed, paving the way for the development of next generation of energy management system (EMS). The developed framework consists of three key components, namely the static state estimation (SSE) module, the dynamic state estimation (DSE) module, the interfaces and switching logics between the two modules. Specifically, the singular spectrum analysis (SSA)-based change point detection approach is developed to monitor the system continuously. If no event is detected by the SSA, the robust SSE using both SCADA and PMU measurements is executed. Otherwise, the event is declared and the results from SSE are used to derive the initial condition for DSE. During the transient process, only PMU-based DSE is executed for system monitoring and it will be terminated when SSA does not detect any change point of the system. After that, the DSE results are forwarded for SSE initialization and bus voltage magnitude and angle estimations. Simulation results carried out on the IEEE 39-bus system demonstrate the effectiveness and benefits of the proposed framework.

Power system state estimation, energy management s↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation

Utilities have been installing microgrids because of the increased resilience and reliability advantages they may provide to the distribution system. A microgrid controller is a critical component in microgrids. It is of great benefit to derisk the installation of microgrid controllers before field deployment. Hardware-in-the-loop (HIL) testing is used by controller developers and utilities to evaluate the controllers under stressful conditions. In this work, a microgrid control function developed by the Synchrophasor Grid Monitoring and Automation (SyGMA) laboratory at the University of California, San Diego is tested in a remote HIL (RHIL) setup. The digital real-time simulation of the detailed microgrid system was operated at the National Renewable Energy Laboratory's Energy Systems Integration Facility. Under such RHIL setup, successful controller operation is contingent on understanding and characterizing the communications channel and in particular network latencies. The novelty of this paper is the proposed use of a RHIL setup that leverages existing power system communications protocols to evaluate the controller in conjunction with the simulation capabilities of a remote facility. The work presented here will provide the complete setup of the HIL evaluation platform, the details of the communications protocols used by the setup for data transfer between the two organizations, test cases developed to evaluate the controller, and the results from the experiments.

controller hardware-in-the-loop↗

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

With the increased requirements of real-time grid monitoring, disturbance location, and situation awareness, Phasor Measurement Units (PMUs) have become more critical for the Wide Area Measurement System (WAMS). However, the vulnerability of PMUs has not been well studied, especially under electromagnetic pulse (EMP) scenarios. The stable operation of the power system will be affected directly once EMP damages them. Therefore, studying their immunity to EMP events is urgent and necessary. In this paper, the effective impedance measurement scheme and pulsed current injection (PCI) testing are proposed for the port impedance measurement and immunity levels of PMUs. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then, the circuit of the pulsed current generator is set to generate a damping sinusoid, and the double exponential wave is applied to the port. Finally, using measured impedance as a generator load, the voltage and current responses of different ports are calculated in the PCI testing simulation. In conclusion, results reveal the characteristics of port impedance, waveforms of voltage and current, and distribution of accumulative energy. The relation between port impedance and the waveforms is discussed.

42 ENGINEERING↗

A Clarke Transformation-Based DFT Phasor and Frequency Algorithm for Wide Frequency Range

Despite its wide applications in power grid monitoring, the classic discrete Fourier transform (DFT)-based synchrophasor estimation algorithms suffer from significant errors when the power system operates under off-nominal frequency conditions. This phenomenon is caused by spectral leakage of DFT and becomes even more severe for single-phase synchrophasor estimation. To address this issue, a theory to eliminate the spectral leakage-caused errors is proposed and a Clarke transformation-based DFT synchrophasor estimation algorithm is proposed to implement the theory in this paper. The Clarke transformation constructs a second signal that has exactly 90° phase angle difference from the original single-phase input signal and helps eliminate the estimation errors for a wide frequency range. The proposed algorithm is tested under the conditions required in the phasor measurement unit standard C37.118.1-2011 and C37.118.1a-2014, as well as the harmonic and noise conditions not required in the standard to verify its performance. More importantly, the idea of using Clarke transformation can be used for other DFT-based synchrophasor algorithms in order to achieve higher synchrophasor measurement accuracy under dynamic conditions. An example is presented at last to demonstrate the expandability of the proposed idea.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Final Report: High Energy Physics at the Energy Frontier at Louisiana Tech

The Louisiana Tech University High Energy Physics group has developed a research program aimed at experimentally testing the Standard Model of particle physics and searching for new phenomena through a focused set of analyses in collaboration with the ATLAS experiment at the Large Hadron Collider (LHC) at the CERN laboratory in Geneva. This research program includes involvement in the current operation and maintenance of the ATLAS experiment and full involvement in Phase 1 and Phase 2 upgrades in preparation for future high luminosity (HL-LHC) operation of the LHC. Our focus is solely on the ATLAS experiment at the LHC, with some related detector development and software efforts. We have established important service roles on ATLAS in five major areas: Triggers, especially jet triggers; Data Quality monitoring; grid computing; GPU applications for upgrades; and radiation testing for upgrades. Our physics research is focused on multijet measurements and top quark physics in final states containing tau leptons, which we propose to extend into related searches for new phenomena. Focusing on closely related topics in the jet and top analyses and coordinating these analyses in our group has led to high efficiency and increased visibility inside the ATLAS collaboration and beyond. Based on our work in the DØ experiment in Run II of the Fermilab Tevatron Collider, Louisiana Tech has developed a reputation as one of the leading institutions pursuing jet physics studies. Currently we are applying this expertise to the ATLAS experiment, with several multijet analyses in progress.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diffusion algorithms and data reduction routine for onsite launch predictions for the transport of Titan 3 C exhaust effluents

The NASA/MSFC multilayer diffusion algorithms have been specialized for the prediction of the surface impact for the dispersive transport of the exhaust effluents from the launch of a Titan 3 vehicle. This specialization permits these transport predictions to be made at the launch range in real time so that the effluent monitoring teams can optimize their monitoring grids. Basically, the data reduction routine requires just the meteorology profiles for the thermodynamics and kinematics of the atmosphere as an input. These profiles are graphed along with the resulting exhaust cloud rise history, the center line concentrations and dosages, and the hydrogen chloride isopleths.

Stephens, J. B.↗

Atmospheric diffusion predictions for the exhaust effluents from the launch of a Titan 3C, December 13, 1973

Results for the predictions with the NASA/MSFC Multilayer Diffusion Model for the dispersive transport of the Titan 3C rocket exhaust effluents for the 1857 EST launch on December 13, 1973, from the Eastern Test Range at Cape Canaveral Air Force Station are presented. An atmospheric assessment is made in support of the joint Marshall Space Flight Center, Langley Research Center, and Kennedy Space Center rocket exhaust prediction and measurement program. The predictions are primarily intended to define a monitoring grid and for a postflight assessment of the field measurements in order to improve diffusion prediction techniques.

Stephens, J. B.↗

Diffusion algorithms and data reduction routine for onsite real-time launch predictions for the transport of Delta-Thor exhaust effluents

The National Aeronautics and Space Administration/Marshall Space Flight Center multilayer diffusion algorithms have been specialized for the prediction of the surface impact for the dispersive transport of the exhaust effluents from the launch of a Delta-Thor vehicle. This specialization permits these transport predictions to be made at the launch range in real time so that the effluent monitoring teams can optimize their monitoring grids. Basically, the data reduction routine requires only the meteorology profiles for the thermodynamics and kinematics of the atmosphere as an input. These profiles are graphed along with the resulting exhaust cloud rise history, the centerline concentrations and dosages, and the hydrogen chloride isopleths.

Stephens, J. B.↗

Multibaseline - A precision ground based geodetic measurement technique

The multibaseline geometric measurement system and its capabilities are described. Station inplane coordinates can always be determined to subcentimeter accuracy by use of one- or two-color geodolites as the fundamental measuring devices; for a given station constellation only one station needs to be substantially out of the plane in order to permit determination of the remaining near inplane coordinates. A realistic simulation of the Palmdale, California geodimeter network is presented, and the equivalence between a static multilateration system and the multibaseline system is established. The extension of local networks to wider monitoring grids is considered.

Escobal, P. R.↗

Simulation of Etching in Chlorine Discharges Using an Integrated Feature Evolution-Plasma Model

To better utilize its vast collection of heterogeneous resources that are geographically distributed across the United States, NASA is constructing a computational grid called the Information Power Grid (IPG). This paper describes various tools and techniques that we are developing to measure and improve the performance of a broad class of NASA applications when run on the IPG. In particular, we are investigating the areas of grid benchmarking, grid monitoring, user-level application scheduling, and decentralized system-level scheduling.

Hwang, Helen H.↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation

Utilities have been installing microgrids because of the increased resilience and reliability advantages they may provide to the distribution system. A microgrid controller is a critical component in microgrids. It is of great benefit to derisk the installation of microgrid controllers before field deployment. Hardware-in-the-loop (HIL) testing is used by controller developers and utilities to evaluate the controllers under stressful conditions. In this work, a microgrid control function developed by the Synchrophasor Grid Monitoring and Automation (SyGMA) laboratory at the University of California, San Diego is tested in a remote HIL (RHIL) setup. The digital real-time simulation of the detailed microgrid system was operated at the National Renewable Energy Laboratory's Energy Systems Integration Facility. Under such RHIL setup, successful controller operation is contingent on understanding and characterizing the communications channel and in particular network latencies. The novelty of this paper is the proposed use of a RHIL setup that leverages existing power system communications protocols to evaluate the controller in conjunction with the simulation capabilities of a remote facility. The work presented here will provide the complete setup of the HIL evaluation platform, the details of the communications protocols used by the setup for data transfer between the two organizations, test cases developed to evaluate the controller, and the results from the experiments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Poster: Responsible Adoption of Artificial Intelligence (AI) in Electric Grid Operations

The rapid integration of artificial intelligence (AI) in the utility transmission and distribution (T&D) sector is revolutionizing traditional grid management practices. As utilities encounter complexities from evolving consumer behaviors and energy integration, AI becomes a critical solution for enhancing grid monitoring, fault detection, and operational optimization. However, increased reliance on interconnected technologies introduces significant cybersecurity risks, regulatory compliance challenges, and human factors concerns. This study proposes a strategic, responsible and consequence-driven approach to AI implementation, examining the dual nature of AI adoption by highlighting its transformative benefits for utilities and associated risks. It provides utilities with a framework for evaluating AI integration, enabling them to navigate challenges and capitalize on opportunities to achieve greater reliability, efficiency, and resilience in an increasingly complex energy landscape.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Fault-tolerant grid frequency measurement algorithm during transients

A system determines the frequency of grid signals corresponding to an electrical grid in real time. The system includes a transient detector that monitors a grid signal from a voltage meter or a current meter connected to the electrical grid. The system produces, in real time and at a sampling rate, a deviation signal indicative of a periodicity of the monitored grid signal. The system determines, over one or more cycles of the monitored grid signal, a measurement signal corresponding to the deviation signal. The system determines a frequency signal that corresponds a frequency estimation of the monitored signal by applying a frequency estimation when values of the measurement signal are less than a deviation threshold and maintaining the frequency signal at a constant value when values of the measured signal equal or exceeds the deviation threshold.

Zhan, Lingwei↗

Optical Fiber Sensor Technology Development and Field Validation for Distribution Transformer and Other Grid Asset Health Monitoring

Power transformers are critical pieces of infrastructure in the electric grid that are both extremely expensive and difficult to replace. These transformers often have long lead times for replacement, and failures can create long service disruptions. This project has developed a new suite of sensors designed to give early warning of the impending failure of these important power transformers before it is too late and a major failure occurs. By using novel fiber optic sensors instead of conventional existing technologies, we are able to measure transformer characteristics indicative of impending failures in ways that were not previously possible. These new optical fiber-based sensors are completely immune to the strong magnetic fields present in power transformers, as well as being capable of using distributed measurement techniques. Distributed measurement techniques enable the fiber to return information all along its length as opposed to only collecting data at a single point; as would a thermocouple or standard pressure sensor.

24 POWER TRANSMISSION AND DISTRIBUTION↗