Assessment of the Phase-to-Ground Fault Apparent Admittance Method with Phase/Ground Boundaries to Detect Types of Electrical Faults for Protective Relays Using Signature Library and Simulated Events

Protective relays in electric power grids recognize the types of electrical faults in a few seconds. The most common detection method to detect the types of electrical faults is based on measuring the angle between the zero and negative sequence currents. However, it is not completely accurate because the phase-to-phase-ground and phase-to-ground electrical faults could have the same detection conditions. Therefore, engineers need to plot the events after an electrical fault to observe the nature of the incidents in detail. In this study, the phase-to-ground fault apparent (PGFA) admittance method with phase/ground boundaries identified the types of electrical faults located in distribution power lines and feeders. This method was based on measuring the PGFA admittance magnitudes for the faulted and nonfaulted phases, resulting in greater than zero and near zero, respectively. The PGFA admittance algorithm was built with MATLAB/Simulink software and tested with signature library and grid simulation events. The PGFA method with phase/ground boundaries was evaluated with the confusion matrix. The measured and predicted values matched in more than 90% of the tests, and the PGFA admittance method with phase/ground boundaries presented an accuracy of 94.3% and a precision of 100%.

42 ENGINEERING↗

Assessment of the Phase-to-Ground Fault Apparent Admittance Method with Phase/Ground Boundaries to Detect Types of Electrical Faults for Protective Relays Using Signature Library and Simulated Events

Protective relays in electric power grids recognize the types of electrical faults in a few seconds. The most common detection method to detect the types of electrical faults is based on measuring the angle between the zero and negative sequence currents. However, it is not completely accurate because the phase to phase ground and phase to ground electrical faults could have the same detection conditions. Therefore, engineers need to plot the events after an electrical fault to observe the nature of the incidents in detail. In this study, the phase to ground fault apparent (PGFA) admittance method with phase/ground boundaries identified the types of electrical faults located in distribution power lines and feeders. This method was based on measuring the PGFA admittance magnitudes for the faulted and non-faulted phases, resulting in greater than zero and near zero, respectively. The PGFA admittance algorithm was built with MATLAB/ Simulink software and tested with signature library and grid simulation events. The PGFA method with phase/ground boundaries was evaluated with the confusion matrix. The measured and predicted values matched in more than 90% of the tests, and the PGFA admittance method with phase/ground boundaries presented an accuracy of 94.3% and a precision of 100%.

Piesciorovsky, Emilio↗

Phasor-Domain Modeling of Inverter Based Resources Considering Unbalanced Grid Faults

A significant increase in inverter-based distributed energy resources (DERs) is expected in distribution systems of the near future. The latest phasor modeling approach of DERs with emerging control technologies can capture relevant dynamics in large-scale three-phase distribution systems with unbalanced construction. However, there is a lack of appropriate phasor models to deal with unbalanced fault scenarios. As such, this paper describes per-phase phasor modeling approach appropriate for unbalanced grid disturbance studies in distribution systems with high penetration of DERs. The overall modeling performance of representative DERs is simulated in phasor domain GridLAB-D environment and validated against controller hardware-in-the loop (CHIL) testing or electromagnetic transient (EMT) based switching model simulation in PSCAD with test cases including different unbalanced grid faults. The high accuracy retained from the simulation verifies the effectiveness of the proposed phasor modeling approach considering interactions between positive and negative sequence signals.

Chen, Zhe↗

Development of a Configurable DERMS Test System in GridAPPS-D

Distributed Energy Resources and their increased penetration within the power grid are a suitable method to provide essential reliability services. In order to do so, they must operate in aggregate. Aggregation of a wide variety of systems with varying standards and protocols is a complex task, which could benefit from rules and standards to support interoperability. To this end, the Portland State University Power Lab has developed the Energy Grid of Things project, which includes a Distributed Energy Resource Management System to provide aggregation and demonstrate the usage of an Energy Services Interface: a set of rules governing the interface between resource owners and aggregator businesses. This thesis presents a Modeling Environment that provides a simulation and test platform reflecting the complex needs of an aggregator. A grid simulator is required that is able to reflect the effects of thousands of Distributed Energy Resources operating in tandem; furthermore, these effects must be communicated to external actors such as the Grid Operator, which provides grid service requests to the aggregator and requires feedback. The Modeling Environment provides all of this functionality by leveraging the GridAPPS-D platform to develop an interoperable class-based system that provides configurable simulations with modular input and output APIs. The Modeling Environment uses abstractions to allow any feasible type of input to be reflected within the model as a Distributed Energy Resource, and serves as a proof-of-concept for the development of aggregation simulation and testing within GridAPPS-D.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Preliminary Study of Building a Transmission Overlay for Regional US Power Grid

Many European countries have taken steps toward a Supergrid in order to transmit large amount of intermittent and remote renewable energy over long distance to load centers. In the US, as the expected increase in renewable generation and electricity demand, similar problem arises. A potential solution is to upgrade the transmission system at a higher voltage by constructing a new overlay grid. This paper will first address basic requirements for such an overlay grid. Potential transmission technologies will also be discussed. A multi-terminal VSC HVDC model is developed in DSATools to implement the overlay grid and a test case on a regional NPCC system will be simulated. Another test system of entire US power grid, with three different interconnections tied together using back-to-back HVDC, is also introduced in this paper. Building an overlay system on top of this test case is ongoing, and will be discussed in future work.

Lei, Yin↗

Incentive-Based Control and Coordination of Distributed Energy Resources. Final Report

The rapid growth of low-inertia renewable energy resources represents an immense opportunity for the U.S. to minimize its carbon footprint, while presenting a challenge for system operators as traditional “spinning” generation resources are displaced. This transformation requires solutions to robustly and cost-effectively manage dynamic changes on the grid while ensuring quality of service. There is growing recognition that distributed energy resources (DERs – loads, distributed generation, storage, electric vehicles, etc.) represent a great potential to perform this function. This report details a scalable hierarchical control strategy for coordinating thousands of heterogeneous DERs in order to provide three ancillary gird services: 1) frequency response, a rapid (within 2 seconds) service used to maintain the grid at 60 Hz; 2) regulation response, a larger response used to balance on-going differences in supply and demand on the grid; and, 3) ramping reserve, used to bring on capacity to replace lost generation. The developed control architecture consists of 1) a Distribution Reliability Coordinator (DRC), 2) aggregator controllers, and finally, 3) DER controllers. The DRC coordinates all the flexible loads and distributed energy resources on the distribution system and bids the aggregate flexibility into the wholesale market. The DRC also performs resource allocation (deciding how the flexible devices on the distribution system will be dispatched) to meet the requirements for each of the three ancillary services. The aggregators control a collection of devices that are geographically co-located and provide a platform to aggregate their flexibility and mitigate uncertainty associated with a single flexible load by managing a large aggregation of similar loads (so that any stochastic effects average out). Finally, DER controllers (for example, thermostats for air conditioners, chargers for electric vehicles) adjust the power consumption of individual devices to ensure accurate and reliable delivery of the requested grid services. Evaluation and validation of this approach was conducted with a mixture of simulation and hardware testing for a range of DERs in residential (air conditioners and water heaters), commercial HVAC (ventilation fans and central chiller plants), and micro-grids (battery energy storage, solar PV etc.). This culminated in DER hardware and simulation models operating in conjunction with grid simulations as part of a large scale federated test-bed demonstration. Simulations of over 10,000 controllable residential devices (a combination of air conditioners, water heaters, batteries, and electric vehicles) demonstrated that this advanced control approach could simultaneously meet all three grid services. Furthermore, hardware-in-the-loop testing was performed with operational micro-grid and commercial building HVAC equipment. The micro-grid equipment (representing PV, battery storage, and back-up generators) demonstrated the ability to meet all frequency response requirements (except ramping time). The commercial building HVAC ventilation equipment successfully provided the regulating response service. An Industry Advisory Board (IAB) was formed and engaged throughout the project to get feed-back on project risks and potential commercialization barriers. Their input was invaluable in identify key risks stemming from regulatory and market access challenges, financial risks from under-performance, and competitive threats from utility-scale solutions such as integrated storage. A phased commercialization plan was developed that addresses continued risk reduction (value proposition refinement and performance uncertainty assessments), piloting through field demonstrations with key stakeholders, and finally, deployment as an emerging standard for DER control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Self-Organizing Nano Grid (SONG) for Energy Access Clusters

In this paper, a bottom-up dc Self-Organizing Nano Grid (SONG) for rural electrification at ultra-low-cost through a flexible and scalable topology is presented. The proposed nano grid requires no communication and uses dc-bus signaling to convey excess energy in the system through the bus voltage, allowing independent agents to conduct energy transactions based on their needs in a decentralized manner. Moreover, this article proposes a concept that uses a novel multi-source, multi-segment droop control strategy with demand coordination, allowing for dynamic self-balancing of the system under fluctuating operating conditions. The unique use of a surplus photovoltaic (PV) power droop mode precisely estimates energy availability to minimize load chattering that helps in stabilizing the dc-bus. In addition, this architecture uses standard dc/dc converters for a low-cost, modular, Plug and Play ( PnP ) solution with highly automated operation, enabling local assembly, operation, and maintenance by non-technical personnel. The proposed SONG concept was validated in simulation and with a 700W, laboratory-scale, custom made nano grid system. The simulation and experimental test cases show the feasibility of the SONG system by demonstrating the proposed multi-source, multi-segment droop control strategy without load chattering under varying operating conditions.

dc-dc converter↗

15 MW HArdware-in-the-loop Grid Simulation Project

The 15MW Hardware-in-the-loop (HIL) Grid Simulator project was to (1) design, (2) construct and (3) commission a state-of-the-art grid integration testing facility for testing of multi-megawatt devices through a ‘shared facility’ model open to all innovators to promote the rapid introduction of new technology in the energy market to lower the cost of energy delivered. The 15 MW HIL Grid Simulator project now serves as the cornerstone of the Duke Energy Electric Grid Research, Innovation and Development (eGRID) Center. This project leveraged the 24 kV utility interconnection and electrical infrastructure of the US DOE EERE funded WTDTF project at the Clemson University Restoration Institute in North Charleston, SC. Additionally, the project has spurred interest from other technology sectors, including large PV inverter and energy storage testing and several leading edge research proposals dealing with smart grid technologies, grid modernization and grid cyber security. The key components of the project are the power amplifier units capable of providing up to 20MW of defined power to the research grid. The project has also developed a one of a kind solution to performing fault ride-through testing by combining a reactive divider network and a large power converter into a hybrid method. This unique hybrid method of performing fault ride-through analysis will allow for the research team at the eGRID Center to investigate the complex differences between the alternative methods of performing fault ride-through evaluations and will ultimately further the science behind this testing. With the final goal of being able to perform HIL experiments and demonstration projects, the eGRID team undertook a significant challenge with respect to developing a control system that is capable of communicating with several different pieces of equipment with different communication protocols in real-time. The eGRID team developed a custom fiber optical network that is based upon FPGA hardware that allows for communication between the key real-time interfaces and reduces the latency between these interfaces to acceptable levels for HIL experiments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Co-Simulation Platform For Characterizing Cyber Attacks in Cyber Physical Systems

Smart grid is a complex cyber physical system containing a numerous and variety of sources, devices, controllers and loads. Communication/Information infrastructure is the backbone of the smart grid system where different grid components are connected with each other through this structure. Therefore, the drawbacks of the information technology related issues are also becoming a part of the smart grid. Further, smart grid is also vulnerable to the grid related disturbances. For such a dynamic system, disturbance and intrusion detection is a paramount issue. This paper presents a Simulink and OPNET based co-simulated test bed to carry out a cyber-intrusion in a cyber-network for modern power systems and smart grid. The effect of the cyber intrusion on the physical power system is also presented. The IEEE 30 bus power system model is used to demonstrate the effectiveness of the simulated testbed. The experiments were performed by disturbing the circuit breakers reclosing time through a cyber-attack in the cyber network. Different disturbance situations in the proposed test system are considered and the results indicate the effectiveness of the proposed co-simulated scheme.

cyber attack characterization↗

Deep Learning-enhanced Block-Diagram Modeling of Solar Power Systems

Data-driven models of power system inverter-based resources are desired to run simulations faster than with detailed electromagnetic transient models, to hide proprietary design details, to support control system design applications, and to aggregate the effects of distributed energy resources. This paper applies a customized Hammerstein Wiener framework to train block diagram models from thousands of electromagnetic transient simulations or experimental test records. The block diagram models integrate with larger grid simulations as voltagecontrolled current sources or current-controlled voltage sources for several simulators. Guidelines for block architecture and training are presented. Three-phase balanced, three-phase unbalanced, and single-phase examples all achieve an acceptable root mean square error of no more than 0.05 per-unit.

Mcdermott, Thomas E. [Private consulting company]↗

Power Hardware-in-the-Loop (PHIL) Testing Facility for Distributed Energy Storage (Poster)

The growing deployment of distributed, variable generation and evolving end-user load profiles presents a unique set of challenges to grid operators responsible for providing reliable and high quality electrical service. Mass deployment of distributed energy storage systems (DESS) has the potential to solve many of the associated integration issues while offering reliability and energy security benefits other solutions cannot. However, tools to develop, optimize, and validate DESS control strategies and hardware are in short supply. To fill this gap, NREL has constructed a power hardware-in-the-loop (PHIL) test facility that connects DESS, grid simulator, and load bank hardware to a distribution feeder simulation.

25 ENERGY STORAGE↗

Hardware-in-the-Loop Testing of Utility-Scale Wind Turbine Generators

Historically, wind turbine prototypes were tested in the field, which was--and continues to be--a slow and expensive process. As a result, wind turbine dynamometer facilities were developed to provide a more cost-effective alternative to field testing. New turbine designs were tested and the design models were validated using dynamometers to drive the turbines in a controlled environment. Over the years, both wind turbine dynamometer testing and computer technology have matured and improved, and the two are now being joined to provide hardware-in-the-loop (HIL) testing. This type of testing uses a computer to simulate the items that are missing from a dynamometer test, such as grid stiffness, voltage, frequency, rotor, and hub. Furthermore, wind input and changing electric grid conditions can now be simulated in real time. This recent advance has greatly increased the utility of dynamometer testing for the development of wind turbine systems.

17 WIND ENERGY↗

EMT Model Validation of a 2 MVA PV Inverter Using Transient and Frequency-Domain Hardware Testing: Preprint

This paper presents results and new insights gained from a hardware test campaign on a 2 MVA PV inverter for validating its vendor-supplied EMT model. The test campaign was conducted using a 7 MVA grid simulator and a 2 MW PV emulator. It considered both time-domain transient tests and frequency-domain impedance scan tests. The paper highlights the inadequacy of transient tests in capturing all critical resonance modes of the inverter, and the effectiveness of the frequency scan testing in addressing this problem. The paper shows the frequency scan testing as an effective tool for EMT model validation of IBR units which can highlight inaccuracies in the EMT models that are easy to overlook when model validation is performed using only the time-domain transient tests such as voltage ride-through and phase jump tests.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Guidelines for volume force distributions within actuator line modeling of wind turbines on large-eddy simulation-type grids

The objective of this work is to develop and test a set of general guidelines for choosing parameters to be used in the state-of-the-art actuator line method (ALM) for modeling wind turbine blades in computational fluid dynamics (CFD). The actuator line method is being increasingly used for the computation of wake interactions in large wind farms in which fully blade-resolving simulations are expensive and require complicated rotating meshes. The focus is on actuator line behavior using fairly isotropic grids of low aspect ratio typically used for large-eddy simulation (LES). Forces predicted along the actuator lines need to be projected onto the flow field as body forces, and this is commonly accomplished using a volumetric projection. In this study, particular attention is given to the spanwise distribution of the radius of this projection. A new method is proposed where the projection radius varies along the blade span following an elliptic distribution. The proposed guidelines for actuator line parameters are applied to the National Renewable Energy Laboratory's (NREL's) Phase VI rotor and the NREL 5-MW turbine. Results obtained are compared with available data and the blade-element code XTurb-PSU. As a result, it is found that the new criterion for the projection radius leads to improved prediction of blade tip loads for both blade designs.

17 WIND ENERGY↗

CGSim: A Simulation Framework for Large Scale Distributed Computing Environment

Large-scale distributed computing infrastructures such as the Worldwide LHC Computing Grid (WLCG) require comprehensive simulation tools for evaluating performance, testing new algorithms, and optimizing resource allocation strategies. However, existing simulators suffer from limited scalability, hardwired algorithms, lack of real-time monitoring, and inability to generate datasets suitable for modern machine learning approaches. We present CGSim, a simulation framework for large-scale distributed computing environments that addresses these limitations. Built upon the validated SimGrid simulation framework, CGSim provides high-level abstractions for modeling heterogeneous grid environments while maintaining accuracy and scalability. Key features include a modular plugin mechanism for testing custom workflow scheduling and data movement policies, interactive real-time visualization dashboards, and automatic generation of event-level datasets suitable for AI-assisted performance modeling. We demonstrate CGSim’s capabilities through a comprehensive evaluation using production ATLAS PanDA workloads, showing significant calibration accuracy improvements across WLCG computing sites. Scalability experiments show near-linear scaling for multi-site simulations, with distributed workloads achieving 6 × better performance compared to single-site execution. The framework enables researchers to simulate WLCG-scale infrastructures with hundreds of sites and thousands of concurrent jobs within practical time budget constraints on commodity hardware.

Vatsavai, Sairam Sri [Brookhaven National Laborato↗

MIRACL Co‐Simulation platform for control and operation of distributed wind in microgrid

Abstract This paper presents a co‐simulation platform (CSP) developed as a part of the “Microgrids, Infrastructure Resilience and Advanced Controls Launchpad (MIRACL)” project, hereafter called MIRACL‐CSP, to allow simulation‐based testing, demonstration, and evaluations of distributed wind under various grid operating conditions. MIRACL‐CSP provides modular interactions among the power distribution system, distributed wind, and utility decision‐making framework. A hierarchical engine for large‐scale infrastructure co‐simulations (HELICS) is used as the core engine of MIRACL‐CSP to establish time and information coordination among the MIRACL‐CSP modules. In this study, MIRACL‐CSP performance is demonstrated using the IEEE 123‐node test distribution grid modelled in GridLAB‐D and the utility decision support application modelled in Python. The functionality of MIRACL‐CSP is demonstrated through various grid operational scenarios in a microgrid and networked microgrid environment. A co‐simulation study is described that demonstrated MIRACL‐CSP capabilities for the microgrid operational scenario in the IEEE 123‐node test system. MIRACL‐CSP is a generic platform that facilitates distributed wind research for different test systems, applications, and valuation of distributed wind.

17 WIND ENERGY↗

Hardware-in-the-loop grid simulator system and method

A hardware-in-the-loop (HIL) electrical grid simulation system and method that combines a reactive divider with a variable frequency converter to better mimic and control expected and unexpected parameters in an electrical grid. The invention provides grid simulation in a manner to allow improved testing of variable power generators, such as wind turbines, and their operation once interconnected with an electrical grid in multiple countries. The system further comprises an improved variable fault reactance (reactive divider) capable of providing a variable fault reactance power output to control a voltage profile, therein creating an arbitrary recovery voltage. The system further comprises an improved isolation transformer designed to isolate zero-sequence current from either a primary or secondary winding in a transformer or pass the zero-sequence current from a primary to a secondary winding.

17 WIND ENERGY↗