Effect of Non-unity Power Factor Operation in Photovoltaic Inverters Employing Grid Support Functions.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
To ensure high penetration of renewable energy sources into power grids, their interfacing inverters need to be designed to provide grid support functions. Important grid support functions include frequency and voltage support. To this end, the research community has recently invested heavily on grid-forming control pilot projects. Grid forming control aims to replace traditional grid following control, which is based on phase-locked loop and can achieve decoupled real and reactive power control. Here, in this article, we review the state-of-the-art grid following and forming technology and point out some deficiencies in dynamic performance in the widely adopted grid-forming control design. We also examine how to ensure that the vector control capable of decoupled real and reactive power regulation can also be achieved in the grid forming design. This type of design has been prototyped and shown great potential to enable retrofitting of large amounts of grid-following controllers through purely software algorithm update. The technology ensures reliable operation of power grids with high penetration of IBRs, thereby further reducing fossil fueled energy sources and cut down carbon emission.
Penetration of solar photovoltaic (PV) installations into the grid has increased in recent years. In the past, photovoltaic installations have not included grid-support functionality. Grid support functions including Volt-VAR (VVAR), Frequency-Watt (FW), Volt-Watt (VW), frequency/voltage-ride through, as well as other inverter functions such as anti-islanding are recommended by standards such as IEEE 1547 to allow PV inverters to contribute to acceptable operation and stability of distribution systems with high penetrations of PV and to ensure predictable response of the PV inverters. First, low-level and high-level grid support inverter control functions were developed and tested in simulation. The developed controller is able to integrate advanced controller functions in a coordinated approach, avoiding any conflict between the different control objectives. The algorithms were then programmed on an off-the-shelf embedded controller that included a dual-core CPU and FPGA. The details of the high-level grid support function and the lower level switching control will be presented. Second, this programmed controller is tested using a controller-hardware-in-the-loop (CHIL) test bed setup using an FPGA-based real-time simulator. The CHIL setup has the capability to run at a 500 nano-second time-step to accommodate the 20 kHz switching frequency of the developed controller. The advanced control function and CHIL test bed details provided here will aide future researchers to design, implement, and test advanced inverter functions for PV inverters.
The project was a collaboration between Clemson University and TECO Westinghouse Motor Company. The goal of the project was to develop a medium voltage commercial grid-tied system with advanced grid support functions. Current state-of-the-art in medium voltage, multi-megawatt power electronic systems do not support advanced grid functions, traditionally due to power electronic limitations and required applications. The developed system is capable of interacting with the power system at the distribution level to efficiently integrate gas turbine generation systems or any other ac generation system with up to 20MWe of power production capacity. This project demonstrated a high level of technical readiness of the 1MW, 500Hz, 15000 RPM high frequency Combined Heat and Power (CHP) generator and electric machine system, utilizing advanced grid support functions required by IEEE Std. 1547-2018.
In this paper, we propose a Hardware-in-the-Loop (HIL) simulation testbed suitable for the implementation and testing of realistic cyberattacks on grid-tied smart inverter systems integrated with Distributed Energy Resources (DER) that use the Distributed Network Protocol-3 (DNP3) protocol for communications between grid components. Specifically, our testbed combines a Real-Time Digital Simulator (RTDS) NovaCor device, outfitted with GNETx2 network interface cards, a gridtied DER topology implemented via the RTDS software package RSCAD, and a custom virtual network that emulates a man in the middle attacker. The Man-in-the-Middle (MITM) attacker captures DNP3 traffic and falsifies telemetry data in DNP3 packets to trigger unwarranted commands from a DNP3 controller that exploit smart inverter grid support functions. We choose DNP3 and implement grid support functions according to the IEEE Std. 1547-2018 mandated for the interconnection and interoperability of DER power systems with associated power components. Furthermore, we develop a protocol payload agnostic attack detection framework that leverages the round-trip time (RTT) anomalies between DNP3 requests and responses and can detect the presence of attacks without having to analyze the payload’s contents, while balancing trade-offs between false alarm counts, missed detections, and time to detection. To facilitate further research, we publicly release benign and attack network traffic exchanged between various sensors, controllers, and actuators in our grid-tied inverter testbed.
An increasing number of jurisdictions are adopting Distributed Energy Resource (DER) interconnection standards which require photovoltaic (PV) inverters, energy storage systems, and other DER to include interoperable grid-support functionality. These functions provide grid operators the nobs to support local and bulk power system operations with DER equipment, but the associated grid operator-to-DER communications networks must be deployed with appropriate cybersecurity features. In some situations, additional security features may prevent control system scalability or increase communication latencies and dropouts. These unintentional consequences of the security features would therefore hinder the ability of the grid operator to implement specific control algorithms. This project evaluated the tradeoffs between power system performance and cybersecurity metrics for several grid services.