Search NASA⌕ Search

SEARCH · Search NASA

Results for “group testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

UAS remote sensing (Osprey platform): Red-green-blue (RGB) imagery, thermal infrared (TIR) imagery, and canopy reflectance, Seward Peninsula, Alaska, 2018

Airborne remote sensing data collected using the Brookhaven National Laboratory's (BNL) heavy-lift unoccupied aerial system (UAS) octocopter platform - the Osprey - operated by the Terrestrial Ecosystem Science and Technology (TEST) group. This package includes data from 34 flights flown over the NGEE-Arctic Council Mile Maker 72 (MM72), Kougarok MM64, Kougarok MM80, and Teller MM27 sites in July, 2018. The Osprey is a multi-sensor UAS platform that simultaneously measures very high spatial resolution optical red/green/blue (RGB) and thermal infrared (TIR) surface "skin" temperature imagery, as well as surface reflectance at 1 nm intervals in the visible to near-infrared spectral range from ~350-1000 nm measured at regular intervals along each flight path. This package provide the Level 0 (raw, unprocessed) data collected by the Osprey platform. Ancillary aircraft data, flight mission parameters, and general flight conditions provided by the onboard flight and data collection computers are also included. Data and metadata are provided as text (*.txt, *.json), tabular (*.dat, *.csv, *.waypoint), and image (*.jpg) formats. This metadata document contains flight campaign, instrument and file metadata, along with a description of the L0 data, and file naming scheme. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

UAS remote sensing (Osprey platform): Red-green-blue (RGB) imagery, thermal infrared (TIR) imagery, and canopy reflectance, Seward Peninsula, Alaska, 2019

Airborne remote sensing data collected using the Brookhaven National Laboratory's (BNL) heavy-lift unoccupied aerial system (UAS) octocopter platform - the Osprey - operated by the Terrestrial Ecosystem Science and Technology (TEST) group (https://www.bnl.gov/testgroup). This package includes data from 17 flights flown over the NGEE-Arctic Council Mile Maker 64 (MM64) and Teller MM27 sites in July, 2019. The Osprey is a multi-sensor UAS platform that simultaneously measures very high spatial resolution optical red/green/blue (RGB) and thermal infrared (TIR) surface "skin" temperature imagery, as well as surface reflectance at 1 nm intervals in the visible to near-infrared spectral range from ~350-1000 nm measured at regular intervals along each flight path. This package provide the Level 0 (raw, unprocessed) data collected by the Osprey platform. Ancillary aircraft data, flight mission parameters, and general flight conditions provided by the onboard flight and data collection computers are also included. Data and metadata are provided as text (*.txt, *.json), tabular (*.dat, *.csv, *.waypoint), and image (*.jpg) formats. This metadata document contains flight campaign, instrument and file metadata, along with a description of the L0 data, and file naming scheme. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Digital camera imagery for vegetation phenology, Seward Peninsula, Alaska, 2022-2023

Timelapse camera images from Council Mile Marker (MM) 71, Kougarok MM 64, Kougarok Fire Complex (KFC), and Teller MM 27 NGEE-Arctic field sites on the Seward Peninsula, Alaska, captured from July 2022 to July 2023. Eight Wingscape Timelapse Pro cameras, and thirty-one Power-interval Camera Automation Modules (PiCAMs) designed by Brookhaven National Laboratory?s Terrestrial Ecosystem Science and Technology (TEST) group were deployed targeting patches of low and tall shrubs (including Alnus sp. and Salix sp.) and general vegetation and landscape views. Images from Wingscape cameras were recorded at hourly intervals from 11 AM to 2 PM, and images from PiCAMs were recorded at 5 hourly intervals from 12 AM to 8 PM, continuously for 12 months and capture vegetation phenology, snow accumulation and snow melt events. This data package includes images (*.jpg), organized by site and camera ID, and metadata with details of the cameras used, number of images recorded, start and end dates, GPS locations and example fields of view. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

A Multi-Sample Standoff Multimodal Biometric System

Abstract The data captured by existing standoff biometric systems typically has lower biometric recognition performance than their close range counterparts due to imaging challenges, pose challenges, and other factors. To assist in overcoming these limitations systems typically perform in a multi-modal capacity such as Honeywell s Combined Face and Iris (CFAIRS) [21] system. While this improves the systems performance, standoff systems have yet to be proven as accurate as their close range equivalents. We will present a standoff system capable of operating up to 7 meters in range. Unlike many systems such as the CFAIRS our system captures high quality 12 MP video allowing for a multi-sample as well as multi-modal comparison. We found that for standoff systems multi-sample improved performance more than multi-modal. For a small test group of 50 subjects we were able to achieve 100% rank one recognition performance with our system.

Barstow, Del R↗

XRD Analysis of Cement Paste Samples Exposed to the Simulated Environment of a Deep Repository - 12239

Portland cement materials are widely used as engineered barriers in repositories for radioactive waste. The capacity of such barriers to avoid the disposed of radionuclides to entering the biosphere in the long-term depends on the service life of those materials. Thus, the performance assessment of structural materials under a series of environmental conditions prevailing at the environs of repositories is a matter of interest. The durability of cement paste foreseen as backfill in a deep borehole for disposal of disused sealed radioactive sources is investigated in the development of the repository concept. Results are intended to be part of the body of evidence in the safety case of the proposed disposal technology. This paper presents the results of X-Ray Diffraction (XRD) Analysis of cement paste exposed to varying temperatures and simulated groundwater after samples received the radiation dose that the cement paste will accumulate until complete decay of the radioactive sources. The XRD analysis of cement paste samples realized in this work allowed observing some differences in the results of cement paste specimens that were submitted to different treatments. The cluster analysis of results was able to group tested samples according to the applied treatments. Mineralogical differences, however, are tenuous and, apart from ettringite, are hardly observed. The absence of ettringite in all the seven specimens that were kept in dry storage at high temperature had hardly occurred by natural variations in the composition of hydrated cement paste because ettringite is observed in all tested except the seven specimens. Therefore this absence is certainly the result of the treatments and could be explained by the decomposition of ettringite. Although the temperature of decomposition is about 110-120 deg. C, it may be initially decomposed to meta-ettringite, an amorphous compound, above 50 deg. C in the absence of water. Influence of irradiation on the mineralogical composition was not observed when the treatment was analyzed individually or when analyzed under the possible synergic effect with other treatments. However, the radiation dose to which specimens were exposed is only a fraction of the accumulated dose in cement paste until complete decay of some sources. Therefore, in the short term, the conditions deemed to prevail in the repository environment may not influence the properties of cement paste at detectable levels. Under the conditions presented in this work, it is not possible to predict the long term evolution of these properties. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initial mechanical stability of cementless highly-porous titanium tibial components

Cementless fixation in total knee replacement has seen limited use since reports of early failure surfaced in the late 80s and early 90s. However the emergence of improved biomaterials, particularly porous titanium and tantalum, has led to a renewed interest in developing a cementless tibial component to enhance long-term survivorship of the implants. Cement is commonly employed to minimize micromotion in new implants but represents a weak interface between the implant and bone. The elimination of cement and application of these new biomaterials, which theoretically provide improved stability and ultimate osseointegration, would likely result in greater knee replacement success. Additionally, the removal of cement from the procedure would help minimize surgical durations and get rid of the time needed for curing, thereby the chance of infection. The purpose of this biomechanical study was twofold. The first goal was to assess whether vibration analysis techniques can be used to evaluate and characterize initial mechanical stability of cementless implants more accurately than the traditional method of micromotion determination, which employs linear variable differential transducers (LVDTs). Second, an evaluative study was performed to determine the comparative mechanical stability of five designs of cementless tibial components under mechanical loading designed to simulate in vivo forces. The test groups will include a cemented Triathlon Keeled baseplate control group, three different 2-peg cementless baseplates with smooth, mid, and high roughnesses and a 4-peg cement/ess baseplate with mid-roughness.

56↗

Characterization, Leaching, and Filtration Testing for Bismuth Phosphate Sludge (Group 1) and Bismuth Phosphate Saltcake (Group 2) Actual Waste Sample Composites

A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan.() The test program was subdivided into logical increments. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. The actual waste-testing program included homogenizing the samples by group, characterizing the solids and aqueous phases, and performing parametric leaching tests. Two of the eight defined groups—bismuth phosphate sludge (Group 1) and bismuth phosphate saltcake (Group 2)—are the subjects of this report. The Group 1 waste was anticipated to be high in phosphorus and was implicitly assumed to be present as BiPO4 (however, results presented here indicate that the phosphate in Group 1 is actually present as amorphous iron(III) phosphate). The Group 2 waste was also anticipated to be high in phosphorus, but because of the relatively low bismuth content and higher aluminum content, it was anticipated that the Group 2 waste would contain a mixture of gibbsite, sodium phosphate, and aluminum phosphate. Thus, the focus of the Group 1 testing was on determining the behavior of P removal during caustic leaching, and the focus of the Group 2 testing was on the removal of both P and Al. The waste-type definition, archived sample conditions, homogenization activities, characterization (physical, chemical, radioisotope, and crystal habit), and caustic leaching behavior as functions of time, temperature, and hydroxide concentration are discussed in this report. Testing was conducted according to TP-RPP-WTP-467.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization, Leaching, and Filtration Testing for Tributyl Phosphate (TBP, Group 7) Actual Waste Sample Composites

.A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. The actual waste-testing program included homogenizing the samples by group, characterizing the solids and aqueous phases, and performing parametric leaching tests. The tributyl phosphate sludge (TBP, Group 7) is the subject of this report. The Group 7 waste was anticipated to be high in phosphorus as well as aluminum in the form of gibbsite. Both are believed to exist in sufficient quantities in the Group 7 waste to address leaching behavior. Thus, the focus of the Group 7 testing was on the removal of both P and Al. The waste-type definition, archived sample conditions, homogenization activities, characterization (physical, chemical, radioisotope, and crystal habit), and caustic leaching behavior as functions of time, temperature, and hydroxide concentration are discussed in this report. Testing was conducted according to TP-RPP-WTP-467.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization and Leach Testing for PUREX Cladding Waste Sludge (Group 3) and REDOX Cladding Waste Sludge (Group 4) Actual Waste Sample Composites

A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan.(a) The testing program was subdivided into logical increments. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. The actual wastetesting program included homogenizing the samples by group, characterizing the solids and aqueous phases, and performing parametric leaching tests. Two of the eight defined groups—plutonium-uranium extraction (PUREX) cladding waste sludge (Group 3, or CWP) and reduction-oxidation (REDOX) cladding waste sludge (Group 4, or CWR)—are the subjects of this report. Both the Group 3 and 4 waste composites were anticipated to be high in gibbsite, requiring caustic leaching. Characterization of the composite Group 3 and Group 4 waste samples confirmed them to be high in gibbsite. The focus of the Group 3 and 4 testing was on determining the behavior of gibbsite during caustic leaching. The waste-type definition, archived sample conditions, homogenization activities, characterization (physical, chemical, radioisotope, and crystal habit), and caustic leaching behavior as functions of time, temperature, and hydroxide concentration are discussed in this report. Testing was conducted according to TP-RPP-WTP-467.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AAPM Task Group 128: Quality assurance tests for prostate brachytherapy ultrasound systems

While ultrasound guided prostate brachytherapy has gained wide acceptance as a primary treatment tool for prostate cancer, quality assurance of the ultrasound guidance system has received very little attention. Task Group 128 of the American Association of Physicists in Medicine was created to address quality assurance requirements specific to transrectal ultrasound used for guidance of prostate brachytherapy. Accurate imaging guidance and dosimetry calculation depend upon the quality and accuracy of the ultrasound image. Therefore, a robust quality assurance program for the ultrasound system is essential. A brief review of prostate brachytherapy and ultrasound physics is provided, followed by a recommendation for elements to be included in a comprehensive test phantom. Specific test recommendations are presented, covering grayscale visibility, depth of penetration, axial and lateral resolution, distance measurement, area measurement, volume measurement, needle template/electronic grid alignment, and geometric consistency with the treatment planning computer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data and Insights for the KRUSTY Nuclear-Powered Tests

This document, and the associated files, describe all of the data from the KRUSTY warm criticals and the KRUSTY nuclear system test. The warm criticals were a group of tests where fission power heated the core and the feedback response was studied. There were 3 experiments, the 15-cent run (which was a true “free run”), followed by 30-cent and 60-cent runs, where reactivity was added to heat the core to higher temperatures. The nuclear system test (often referred to as the full-run or the final-run), engaged the power conversion system and evaluated system performance. These experiments are described in a pair of NUCLEAR TECHNOLOGY papers, which includes plots of the data that this document-set includes. Note that a lot of information in this document is based on my interpretation and could be wrong, but I’ve included it to potentially save some people a lot of time and headaches by trying to figure out which instrumentation to believe, but beware treating anything I say as fact. I’ve also included several post-irradiation photos, to show some thermocouple locations and indicate possible changes in emissivity and/or geometry (although no changes in geometry were indicated).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental Procedure and Results for Contact Thermal Conductance Measurements performed during FY 2021

Weapons Test Engineering groups at LANL are responsible for testing and simulating weapon assemblies and subassemblies in support of qualification and certification of nuclear weapon systems. The complex nature of the assemblies themselves coupled with the loading environments, gives rise to low confidence and high uncertainties in the interpretation of both experimental and simulated results. In an effort to reduce these uncertainties, a project was started at LANL to perform focused and systematic experiments combined with simulations to increase confidence in both arenas. A key goal of the work performed under the Delivery Environments (DE) Testbeds to Reduce Uncertainties in Simulations and Tests TRUST program, focuses on identifying and minimizing sources of uncertainty associated with experimental and computational techniques. Specifically, with the above as motivation, a measurement procedure was developed by MST-8 to perform thermal conductivity measurements on cylinders of both similar and dissimilar metallic systems as a function of loading conditions and varying material interface morphologies between these components.

36 MATERIALS SCIENCE↗

Initial Experience with Balloon-Occluded Trans-catheter Arterial Chemoembolization (B-TACE) for Hepatocellular Carcinoma

PurposeThis study was performed to evaluate the accumulation of lipiodol emulsion (LE) and adverse events during our initial experience of balloon-occluded trans-catheter arterial chemoembolization (B-TACE) for hepatocellular carcinoma (HCC) compared with conventional TACE (C-TACE).MethodsB-TACE group (50 cases) was compared with C-TACE group (50 cases). The ratio of the LE concentration in the tumor to that in the surrounding embolized liver parenchyma (LE ratio) was calculated after each treatment. Adverse events were evaluated according to the Common Terminology Criteria for Adverse Effects (CTCAE) version 4.0.ResultsThe LE ratio at the level of subsegmental showed a statistically significant difference between the groups (t test: P < 0.05). Only elevation of alanine aminotransferase was more frequent in the B-TACE group, showing a statistically significant difference (Mann–Whitney test: P < 0.05). While B-TACE caused severe adverse events (liver abscess and infarction) in patients with bile duct dilatation, there was no statistically significant difference in incidence between the groups. Multivariate logistic regression analysis suggested that the significant risk factor for liver abscess/infarction was bile duct dilatation (P < 0.05).ConclusionThe LE ratio at the level of subsegmental showed a statistically significant difference between the groups (t test: P < 0.05). B-TACE caused severe adverse events (liver abscess and infarction) in patients with bile duct dilatation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pore-scale and Continuum Simulations of Solute Transport Micromodel Benchmark Experiments

Four sets of micromodel nonreactive solute transport experiments were conducted with flow velocity, grain diameter, pore-aspect ratio, and flow focusing heterogeneity as the variables. The data sets were offered to pore-scale modeling groups to test their simulators. Each set consisted of two learning experiments, for which all results was made available, and a challenge experiment, for which only the experimental description and base input parameters were provided. The experimental results showed a nonlinear dependence of the dispersion coefficient on the Peclet number, a negligible effect of the pore-aspect ratio on transverse mixing, and considerably enhanced mixing due to flow focusing. Five pore-scale models and one continuum-scale model were used to simulate the experiments. Of the pore-scale models, two used a pore-network (PN) method, two others are based on a lattice-Boltzmann (LB) approach, and one employed a computational fluid dynamics (CFD) technique. The learning experiments were used by the PN models to modify the standard perfect mixing approach in pore bodies into approaches to simulate the observed incomplete mixing. The LB and CFD models used these experiments to appropriately discretize the grid representations. The continuum model use published non-linear relations between transverse dispersion coefficients and Peclet numbers to compute the required dispersivity input values. Comparisons between experimental and numerical results for the four challenge experiments show that all pore-scale models were all able to satisfactorily simulate the experiments. The continuum model underestimated the required dispersivity values and, resulting in less dispersion. The PN models were able to complete the simulations in a few minutes, whereas the direct models needed up to several days on supercomputers to resolve the more complex problems.

benchmark↗

Health-Related Quality of Life 2 Years After Treatment With Radical Prostatectomy, Prostate Brachytherapy, or External Beam Radiotherapy in Patients With Clinically Localized Prostate Cancer

Purpose: To compare treatment impact on health-related quality of life (HRQL) in patients with localized prostate cancer, from before treatment to 2 years after the intervention. Methods and Materials: This was a longitudinal, prospective study of 614 patients with localized prostate cancer treated with radical prostatectomy (134), three-dimensional external conformal radiotherapy (205), and brachytherapy (275). The HRQL questionnaires administered before and after treatment (months 1, 3, 6, 12, and 24) were the Medical Outcomes Study 36-Item Short Form, the Functional Assessment of Cancer Therapy (General and Prostate Specific), the Expanded Prostate Cancer Index Composite (EPIC), and the American Urological Association Symptom Index. Differences between groups were tested by analysis of variance and within-group changes by univariate repeated-measures analysis of variance. Generalized estimating equations (GEE) models were constructed to assess between-group differences in HRQL at 2 years of follow-up after adjusting for clinical variables. Results: In each treatment group, HRQL initially deteriorated after treatment with subsequent partial recovery. However, some dimension scores were still significantly lower after 2 years of treatment. The GEE models showed that, compared with the brachytherapy group, radical prostatectomy patients had worse EPIC sexual summary and urinary incontinence scores (-20.4 and -14.1; p < 0.001), and external radiotherapy patients had worse EPIC bowel, sexual, and hormonal summary scores (-3.55, -5.24, and -1.94; p < 0.05). Prostatectomy patients had significantly better EPIC urinary irritation scores than brachytherapy patients (+4.16; p < 0.001). Conclusions: Relevant differences between treatment groups persisted after 2 years of follow-up. Radical prostatectomy had a considerable negative effect on sexual functioning and urinary continence. Three-dimensional conformal radiotherapy had a moderate negative impact on bowel functioning, and brachytherapy caused moderate urinary irritation. These results provide relevant information for clinical decision making.

62 RADIOLOGY AND NUCLEAR MEDICINE↗