Search NASA⌕ Search

SEARCH · Search NASA

Results for “heat conduction control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Detailed Laboratory Evaluation of Electric Demand Load Shifting Potential of Controlled Heat Pump Water Heaters

The demand profile management of electric end uses is vital research for utilities and policymakers planning greenhouse gas emission reductions. In this study, detailed laboratory research was conducted on the load shifting potential of 4 grid-connected HPWHs and one electric resistance water heaters (ERWH). The testing applied different CTA-2045 shed and critical peak command designs under three water draw profiles. Highly-controlled laboratory experiments were conducted in Florida. One of the four HPWHs was a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load-up above tank setpoint. A three-hour morning (6 – 9 AM) and four-hour evening curtailment (4 – 8 PM) were defined as the shed or critical peak periods reflecting high-value control periods for utility coincident load for system-wide electric demand reductions. Tests were performed under baseline conditions (no load shift) and under varied load-shifting schemes, including load up and advanced load up, ahead of shed and critical peak commands. Data were collected from December 2020 – February 2022 in the laboratory and compared with field experiments in Florida and the Pacific Northwest. Grid-connected HPWHs were found to reduce peak demand by up to 0.47 kW compared to uncontrolled HPWH units, depending on time of day, control scheme, draw profile, and temperature cluster. The load up strategy demonstrated the ability of all units to utilize heat pump mode for extended periods ahead of peak events. Demand reductions for the HPWHs were much larger when compared with the ERWH— up to 1.64 kW with large hot water draws in winter.

Fenaughty, Karen↗

Approaches for effective negative pressure isolation space control to minimize airborne transmission of contaminants in residential homes

Controlling airborne transmission of contaminants including respired viruses such as SARS-CoV-2 is necessary to protect occupants living in the same house with a contagious person. The effectiveness of interventions requiring minor efforts that create a negative pressure isolation zone (IZ) for a contagious person has yet to be systematically tested for residential homes. In this study, ASHRAE Standard 170, which offers guidance for negative pressure isolation space control in healthcare facilities, was used in developing practical and attainable recommendations for residential single-family homes. The relative effectiveness of several control strategies was evaluated through experimentally conducting 17 different test cases in a manufactured single-family house laboratory. These cases were designed based on various heating, ventilation and air-conditioning (HVAC) operating scenarios, intervention measures including closing the IZ door and/or sealing over supply and return air grilles in the IZ, and utilization of bathroom exhaust or portable window fans for pressure control. Four out of 17 test cases were identified as having the potential for strong containment with adequate depressurization in the IZ. The most effective IZ depressurization was achieved through continuously operating the exhaust fan in the bathroom attached to the IZ, by installing a portable window fan that extracted air out of the IZ, and a portable room air conditioner with the AC unit exhaust duct installed in one of the IZ windows.

Construction & Building Technology↗

Optical phonon dominated heat transport: A first-principles thermal conductivity study of BaSn 2

Acoustic phonons with long mean free paths have long been believed to control the lattice thermal conductivity κ L in solids dominantly. In this study, however, we demonstrate an optical phonon dominated κ L in BaSnS 2 . By solving the Peierls-Boltzmann transport equation, we predict a low diagonal lattice thermal conductivity κ L (D) of 0.34 W m -1 K -1 at 850 K, which is less than half the κ L (D) of SnS at the same temperature. Further calculations following the Allen-Feldman model suggest the additional off-diagonal lattice thermal conductivity κ L (OD) contributed by wavelike tunneling phonons. The κ L (OD) becomes pronounced at the high temperature ( 0.17 W m -1 K -1 at 850 K) and leads to a deviation of the temperature dependence of κ L from T -1 to T -0.76 , suggesting the potential lattice anharmonicity in BaSnS 2 . Further analyses indicate BaSnS 2 has over 68% of κ L contributed by optical phonons. We show this uncommon optical phonon dominated κ L is due to the relatively high group velocities of optical phonons in BaSnS 2 . The phonon mode visualization suggests these relatively high-velocity optical phonons correspond to the antiphase vibrations in BaSnS 2 monolayers, which is originated from the unique permutation of SnS 3 tetrahedra. Finally, by investigating the mode-resolved group velocity, relaxation time, and Grüneisen parameter, we attribute the intrinsic low κ L of BaSnS 2 to the soft lattice and the relatively high lattice anharmonicity induced by the Ba-S weak bonding and Sn(II) lone-pair electrons. Our study explicitly analyzes the microscopic mechanism of optical phonon dominated heat transport in BaSnS 2 and suggests it worthy of further experimental studies as an intrinsic low-κ L material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation of solid-state bidirectional thermal conductivity switching in antiferroelectric lead zirconate (PbZrO 3 )

Materials with tunable thermal properties enable on-demand control of temperature and heat flow, which is an integral component in the development of solid-state refrigeration, energy scavenging, and thermal circuits. Although gap-based and liquid-based thermal switches that work on the basis of mechanical movements have been an effective approach to control the flow of heat in the devices, their complex mechanisms impose considerable costs in latency, expense, and power consumption. As a consequence, materials that have multiple solid-state phases with distinct thermal properties are appealing for thermal management due to their simplicity, fast switching, and compactness. Thus, an ideal thermal switch should operate near or above room temperature, have a simple trigger mechanism, and offer a quick and large on/off switching ratio. In this study, we experimentally demonstrate that manipulating phonon scattering rates can switch the thermal conductivity of antiferroelectric PbZrO 3 bidirectionally by –10% and +25% upon applying electrical and thermal excitation, respectively. Our approach takes advantage of two separate phase transformations in PbZrO 3 that alter the phonon scattering rate in different manners. In this study, we demonstrate that PbZrO 3 can serve as a fast (<1 second), repeatable, simple trigger, and reliable thermal switch with a net switching ratio of nearly 38% from ~1.20 to ~1.65 W m –1 K –1 .

25 ENERGY STORAGE↗

Bifunctional Asymmetric Fabric with Tailored Thermal Conduction and Radiation for Personal Cooling and Warming

Personal thermal management is emerging as a promising strategy to provide thermal comfort for the human body while conserving energy. By improving control over the heat dissipating from the human body, personal thermal management can provide effective personal cooling and warming. Here, we propose a facile surface modification approach to tailor the thermal conduction and radiation properties based on commercially available fabrics, to realize better management of the whole heat transport pathway from the human body to the ambient. Additionally, a bifunctional asymmetric fabric (BAF) offering both a cooling and a warming effect is demonstrated. Due to the advantages of roughness asymmetry and surface modification, the BAF demonstrates an effective cooling effect through enhanced heat conduction and radiation in the cooling mode; in the warming mode, heat dissipation along both routes is reduced for personal warming. As a result, a 4.6 °C skin temperature difference is measured between the cooling and warming BAF modes, indicating that the thermal comfort zone of the human body can be enlarged with one piece of BAF clothing. We expect this work to present new insights for the design of personal thermal management textiles as well as a novel solution for the facile modification of available fabrics for both personal cooling and warming.

42 ENGINEERING↗

Automated Control for Nuclear Thermal Propulsion Start-Up using MOOSE-based Applications

This report presents a Griffin/Bison/RELAP-7 numerical model of a prototypical NTP system that features fuel assemblies arranged in rings, and which was designed to simulate rapid startup transients. The physics modeled include full-core neutronics, assembly-wise heat conduction, and conjugate heat transfer, with the balance of plant mainly imposed through boundary conditions. In addition, various forms of automated reactivity control were deployed by using the MOOSE to autonomously drive the model and simulate the reactor transitioning from assumed initial conditions to nominal power in a fraction of a minute. To generate the cross-sections of the neutronics model, and in an effort to simultaneously account for the tremendous axial temperature gradients in the reactor and to limit the number of state points required for cross-section generation, the average component temperatures and hydrogen densities in the cooling channels were correlated to the average fuel and moderator temperatures, and fixed axial profiles were derived for nominal conditions and then used during the transient. With this approximation, a tractable cross-section library tabulated with fuel/moderator temperatures and CD angles was generated using Serpent. The full-core SPH correction procedure and the CD decusping technology in Griffin, respectively, ensure preservation of the multiplication factor and reaction rates at state points, along with a reasonably accurate reactivity worth between tabulated CD angles, despite using a coarse mesh. Feedback from other physics was calculated by modeling one representative fuel assembly per ring, along with the corresponding fuel and moderator cooling channels. To limit power overshoots during startup, another layer of multiphysics coupling was added to the model in order to automatically control the drums. Two different technologies presented herein showed outstanding performance in this regard: (1) a novel hybrid PID controller based on both power and reactivity signals, and (2) a PGC that relies on kinetics parameters and reactivity coefficients to predict future behavior and adjust the desired signal accordingly. A challenging benchmark was devised, featuring a power demand curve that exponentially increases by a factor of 500 within 30 seconds, then levels out after that. Both control approaches create a simulated power curve that closely follows the power demand curve and limits power overshoots to 1% or less. While the former approach requires more tuning of the internal parameters, the latter requires additional knowledge of the reactivity feedback coefficients and rates of change of the corresponding variables, including fuel and moderator temperature, which could be difficult to dynamically measure for a real NTP system. Fortunately, some inaccuracy in these quantities will not drastically degrade the PGC performance. Subsequently, a more realistic startup sequence was considered, in which the mass flow rate and outlet pressures are ramped up to model bootstrap and thrust build-up phases prior to reaching steady-state conditions, demonstrating the ability of the hybrid PID and PGCs to handle such transients, with both types of controllers exhibiting very similar behavior. Nevertheless, a significant chamber temperature overshoot was observed, caused by the demanded power signal and assumed mass flow rate. This issue could be mitigated by deploying a reactor controller that follows the chamber temperature signal and actuates both the control valves and drums (rather than using a power signal based solely on the drums to control reactivity). Enhancement of the hydrogen fluid properties available in MOOSE, as well as a better understanding of prototypical initial conditions, are also needed to further enhance this startup model. Finally, a study was performed to model decay heat post-shutdown, and to prepare for extending this model to predict shutdown behavior and post-shutdown pulsed cooling requirements.

33 ADVANCED PROPULSION SYSTEMS↗

Laboratory Heat Flux Estimates of Seawater Foam for Low Wind Speeds

Laboratory experiments were conducted to measure the heat flux from seafoam continuously generated in natural seawater. Using a control volume technique, heat flux was calculated from foam and foam-free surfaces as a function of ambient humidity (ranged from 40% to 78%), air–water temperature difference (ranged from -9 °C to 0 °C), and wind speed (variable up to 3 m s-1). Water-surface skin temperature was imaged with a calibrated thermal infrared camera, and near-surface temperature profiles in the air, water, and foam were recorded. Net heat flux from foam surfaces increased with increasing wind speed and was shown to be up to four times greater than a foam-free surface. The fraction of the total heat flux due to the latent heat flux was observed for foam to be 0.75, with this value being relatively constant with wind speed. In contrast, for a foam-free surface the fraction of the total heat flux due to the latent heat flux decreased at higher wind speeds. Temperature profiles through foam are linear and have larger gradients, which increased with wind speed, while foam free surfaces show the expected logarithmic profile and show no variation with temperature. The radiometric surface temperatures show that foam is cooler and more variable than a foam-free surface, and bubble-resolving thermal images show that radiometrically transparent bubble caps and burst bubbles reveal warm foam below the cool surface layer, contributing to the enhanced variability.

54 ENVIRONMENTAL SCIENCES↗

Disentangling the Relative Drivers of Seasonal Evapotranspiration Across a Continental-Scale Aridity Gradient

Evapotranspiration (ET) is a significant ecosystem flux, governing the partitioning of energy at the land surface. Understanding the seasonal pattern and magnitude of ET is critical for anticipating a range of ecosystem impacts, including drought, heat-wave events, and plant mortality. Here, in this study, we identified the relative controls of seasonal variability in ET, and how these controls vary among ecosystems. We used overlapping AmeriFlux and PhenoCam time series at a daily timestep from 20 sites to explore these linkages (# site-years >100), and our study area covered a broad climatological aridity gradient in the U.S. and Canada. We focused on disentangling the most important controls of bulk surface conductance (G s ) and evaporative fraction (EF = LE/[H + LE]), where LE and H represent latent and sensible heat fluxes, respectively. Specifically, we investigated how vegetation phenology varied in importance relative to meteorological variables (vapor pressure deficit and antecedent precipitation) as a driver of G s and EF using path analysis, a framework for quantifying and comparing the causal linkages among multiple response and explanatory variables. Our results revealed that the drivers of G s and EF seasonality varied significantly between energy- and water-limited ecosystems. Specifically, precipitation had a much higher effect in water-limited ecosystems, while seasonal patterns in canopy greenness emerged as a stronger control in energy-limited ecosystems. Given that phenology is expected to shift under future climate, our findings provide key information for understanding and predicting how phenology may impact 21st-century hydroclimate regimes and the surface-energy balance.

54 ENVIRONMENTAL SCIENCES↗

Bentonite buffer under high temperature: laboratory experiments and coupled process modeling

Abstract. Bentonite buffer in a geological repository will be simultaneously heated from decaying radioactive waste and hydrated from the surrounding host rock, triggering complex and coupled THMC (thermal–hydrological–mechanical–chemical) processes. Understanding the THMC behavior of bentonite-based engineered barrier system (EBS) is key to the evaluation and prediction of its long-term performance. Studies on the THMC process have been focused on conditions under 100 ∘C, as most design concepts impose a thermal limit of 100 ∘C in bentonite. Recently, studies under high-temperature conditions have been conducted to evaluate the possibility of raising the thermal limit and expanding the data/knowledge base to increase the confidence level. In this abstract, we present a series of bench-scale laboratory experiments at high temperatures (up to 200 ∘C) and the corresponding modeling work. Two sets of column tests were conducted, and each set consisted of two test columns: a control column undergoing only hydration (non-heated) and an experiment column experiencing both heating and hydration (heated). During the experiment, frequent X-ray computed tomography (CT) images were collected to provide a 3D visualization of the density distribution and present the spatiotemporal evolution of (1) hydration/dehydration, (2) clay swelling/shrinkage, (3) displacement, and (4) mineral precipitation. The two sets of tests differ with respect to several experimental conditions, such as bentonite type, compacted density and water content, water chemistry, and hydration pressure, but the important difference is that the first set used bentonite powder with a dry density of 1.28 g cm−3, whereas the second set used granulated bentonite (mixture of pellets and powder) with a dry density of 1.45–1.5 g cm−3. In both sets of experiments, a comprehensive post-dismantling characterization of bentonite samples was carried out after the column tests had been running for 1.5 years. Comparing non-heated and heated columns, the temperature gradient led to lower degree of homogenization of bentonite after bentonite became fully saturated; comparing the first and second sets, granulated and powdered bentonite exhibited drastically different hydration behavior. A THM model with a 2D axisymmetric grid system was used to interpret the data from the first set of tests. The model considers the combined impact of saturation, fluid pressure, and porosity change due to swelling/compression on the spatiotemporal distribution of bulk density and movement of the thermocouple modules. Observations from the tests help us understand the early perturbation of bentonite buffer under high temperature, and data from these tests improve the calibration of key constitutive hydrological and mechanical models and, therefore, enhance the modeling capability with respect to calculating the long-term evolution of bentonite buffer.

Zheng, Liange↗

Deciphering the sensitivity of urban canopy air temperature to anthropogenic heat flux with a forcing-feedback framework

Abstract The sensitivity of urban canopy air temperature ( T a ) to anthropogenic heat flux ( Q A H ) is known to vary with space and time, but the key factors controlling such spatiotemporal variabilities remain elusive. To quantify the contributions of different physical processes to the magnitude and variability of Δ T a / Δ Q A H (where Δ represents a change), we develop a forcing-feedback framework based on the energy budget of air within the urban canopy layer and apply it to diagnosing Δ T a / Δ Q A H simulated by the Community Land Model Urban over the contiguous United States (CONUS). In summer, the median Δ T a / Δ Q A H is around 0.01 K W m − 2 − 1 over the CONUS. Besides the direct effect of Q A H on T a , there are important feedbacks through changes in the surface temperature, the atmosphere–canopy air heat conductance ( c a ), and the surface–canopy air heat conductance. The positive and negative feedbacks nearly cancel each other out and Δ T a / Δ Q A H is mostly controlled by the direct effect in summer. In winter, Δ T a / Δ Q A H becomes stronger, with the median value increased by about 20% due to weakened negative feedback associated with c a . The spatial and temporal (both seasonal and diurnal) variability of Δ T a / Δ Q A H as well as the nonlinear response of Δ T a to Δ Q A H are strongly related to the variability of c a , highlighting the importance of correctly parameterizing convective heat transfer in urban canopy models.

54 ENVIRONMENTAL SCIENCES↗

The first field application of a low-cost MPC for grid-interactive K-12 schools: Lessons-learned and savings assessment

K-12 schools are the largest energy consumers in the public sector, with their HVAC energy consumption representing the largest portion of their total energy use. While transitioning these schools to grid-interactive HVAC system operation through advanced controls offers significant financial and environmental benefits, and model predictive control (MPC) has been identified as a promising solution to achieve that, very few MPCs are affordable and have been deployed in K-12 schools. This situation raises concerns about the unclear real-world benefits of MPC technology among facility managers and industries. To address this gap, this paper presents a low-cost MPC solution that requires minimal control infrastructure costs and a unique field demonstration at a K-12 school, conducted for both cooling and heating seasons. This work adopted a previously developed MPC and extended it for use in the school application. The MPC aims to coordinate multiple packaged units to eliminate unnecessary peaks and shift cooling or heating loads in response to grid signals based on load conditions, while maintaining thermostat temperatures within school-defined bounds. Throughout the field tests, the MPC achieved a 24% reduction in peak demand during the cooling season and shifted cooling or heating loads by up to 16% in response to the school's utility tariff, considering load conditions, while also allowing end-users to override thermostat setpoints. Further, the paper also discusses the limitations of this study and future research directions for better performance of the MPC at K-12 schools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-order aquifer thermal energy storage model for geothermal system simulation

This paper presents a low-order aquifer thermal energy storage (ATES) model for simulation of combined subsurface and above-surface energy systems. The model is included in the Modelica IBPSA Library, which is a free open-source library with basic models for building and district energy and control systems. The model uses a lumped-component method, in which the transient conductive-convective heat and mass transfer equation is radially discretized. To verify the accuracy of the model, we present an inter-model comparison from a simulation test suite. Results show that the Modelica ATES model is in good agreement, with a normalized mean bias error for yearly variation of aquifer temperatures of 1.6×10−2 and 9×10−5 at 1 m and 10 m distance from the well.

Maccarini, Alessandro↗

Seamlessly Fuel Flexible Heat Pump with Optimal Model-based Control Strategies to Reduce Peak Demand, Utility Cost and CO2 Emission

This research develops a novel hybrid fuel heat pump system for space heating of residential and small commercial buildings with built-in optimization and control. Whereas conventional dual fuel systems either run on gas or electricity at any given moment, the proposed seamlessly fuel flexible heat pump (SFFHP) simultaneously consumes gas and electricity and continuously optimizes the proportion of each. The building air flows across the heat pump condenser first and then flows across the furnace coil, and this reduces the heat pump temperature lift. The SFFHP delivers energy savings by allowing each subsystem (gas furnace and electric heat pump) to operate where it performs best to improve energy efficiency, minimize energy cost, and minimize carbon footprint. The capacities of the electric heat pump and gas furnace are continuously adjusted based on ambient conditions, utility price signals, and marginal grid emission signals. An optimal model predictive control strategy was developed with the goal of minimizing utility cost and minimizing CO2 emission. Two case studies were conducted to simulate the performance of SFFHP during the heating season in Chicago and Los Angeles, respectively. Compared with a conventional electric heat pump, SFFHP yields 33% utility cost reduction and 49% CO2 emission reduction in Chicago. Similarly, it achieves 23% utility cost reduction and 17% CO2 emission reduction in Los Angeles. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. Due to the hybrid fuel nature of this novel equipment, user comfort will always be maintained. The fuel flexibility makes it an attractive option for demand response programs.

Li, Zhenning↗

Modular Iron–Bipyridine-Based Conjugated Aerogels as Catalysts for Oxygen Reduction Reaction

Aerogels have a large surface area and a porous structure, which make them an attractive catalyst support materials for fuel cells. Modifying the aerogels’ building blocks and introducing catalytic sites into their backbones allow them to function as both catalysts and supports, thereby increasing the density and distribution of catalyst active sites. In this work, we studied conjugated aerogels containing iron–bipyridine catalytic sites for the oxygen reduction reaction. To demonstrate the variation in physical and electrochemical properties of these aerogels, a series of aerogels were synthesized by a Glaser coupling reaction. Iron salt was added to the three-dimensional gel to produce iron–bipyridine complexes and obtain atomically dispersed catalytic sites. The electrocatalytic activity and electrical conductivity of the aerogels were increased after their heat treatment to yield Fe-doped carbon aerogels. The control of metal loadings was accomplished by changing the bipyridine content during the aerogel synthesis, resulting in 0.9–4.1 wt % Fe. In conclusion, the results show a correlation between Fe loading, aerogel structure, and catalytic activity, achieving high performance for the oxygen reduction reaction in both acidic and alkaline media.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

System and method for thermal emission control using segmented array

The present disclosure relates to a thermal emissivity control system. The system may have a segmented array that makes use of a thermally conductive base layer configured to be connectable to an external heat generating subsystem, with the base layer including a thermally emissive surface. The array may also have a plurality of actuation elements at least one of positioned on or adjacent to the thermally emissive surface. A plurality of movable shutter elements is disposed adjacent one another in a grid pattern, and controlled in movement by the actuation elements to create gaps of controllably varying dimension therebetween. The shutter elements control at least one of a magnitude of, or direction of, thermal radiation through the gaps.

Panas, Robert Matthew↗

Thermal diode and thermal switch for bi-directional heat transfer in building envelopes

The present disclosure relates to a directional heat transfer using thermal control devices, including a dual phase change thermal diode and an active contact-based thermal switch. The thermal diode includes a positive temperature coefficient switching material and a negative temperature coefficient switching material arranged in series. The thermal switch includes two thermally conducting surfaces which may be moved to contact (i.e., having a distance between them of substantially zero) creating minimal thermal contact resistance. Both thermal control devices may be used to control heat flow into and/or out of a building.

Kishore, Ravi Anant↗

Reconfigurable Electrical Networks within a Conductive Hydrogel Composite

Soft materials that exhibit compliance, programmability, and reconfigurability can have a transformative impact as electronic skin for applications in wearable electronics/soft robotics. There has been significant progress in soft conductive materials; however, achieving electrically controlled and reversible changes in conductivity and circuit connectivity remains challenging. To overcome this limitation, a soft material architecture with reconfigurable conductive networks of silver flakes embedded within a hydrogel matrix is presented. The conductive networks can be reversibly created/disconnected through various stimuli, including current, humidity, or temperature. Such stimuli affect electrical connectivity of the hydrogel by controlling its water content, which can be modulated by evaporation under ambient conditions (passive dehydration), evaporation through electrical Joule heating (active dehydration), or absorption of additional water (rehydration). The resulting change in electrical conductivity is reversible and repeatable, endowing the composite with on-demand reconfigurable conductivity. To highlight this material's unique properties, it is shown that conductive traces can be reconfigured after severe damage and revert to lower conductivity after rehydration. Additionally, a quadruped robot is demonstrated that can respond to stimuli by changing direction following exposure to excess water, thereby achieving reprogrammable locomotion behaviors.

36 MATERIALS SCIENCE↗