Search NASA⌕ Search

SEARCH · Search NASA

Results for “heat planning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Mitigating urban climate-energy feedback with citywide building-integrated photovoltaics implementation

Urban heat islands (UHIs) intensify cooling demands, whose waste heat further exacerbates UHI, creating a self-reinforcing feedback loop. Building-integrated photovoltaics (BIPV) can break this cycle by generating electricity and altering urban climate-energy interactions, yet its net impact remains unresolved. Using a cross-scale modeling framework for 118,521 buildings in Hong Kong, we demonstrate that BIPV glazing reduces cooling demand through improved insulation and lower solar heat gain, while inducing diurnal thermal asymmetry of daytime warming (up to +1.9°C) and nighttime cooling (up to −2.5°C). This microclimate regulation indirectly contributes to a 0.6% reduction in citywide building energy use. Cumulative savings from electricity generation and reduced energy use reach 4.7% (2,060.2 GWh) and 10.1% (4,401.3 GWh) under low- and high-coverage deployment, respectively, with building-level savings of −20.1% ± 11.7% (mean ± SD) at high coverage. We establish BIPV as a configurable climate-energy regulator that enables net-zero, heat-resilient planning and quantifies deployment trade-offs in cooling-dominated cities worldwide.

Building-integrated photovoltaics (BIPV)↗

A review of challenges, barriers, and opportunities for large-scale deployment of cool surfaces

Major urban centers are warming due to a combination of global and local phenomena. City governments are increasingly adopting strategies to mitigate the causes and impacts of extreme heat on their populations. Among these strategies are high solar-reflectance (cool) surfaces installed on building roofs and walls. Use of cool surfaces is a cost-effective and simple strategy that replaces conventional darker surfaces with surfaces that have a high reflectance to shortwave (solar) energy. This report reviews the recent history of cool-surface deployment efforts. This includes peer-reviewed literature, conference proceedings, and grey literature to identify challenges and barriers to wide-scale deployment of cool surfaces. We have also researched heat action plans and programs from cities and different codes and standards, as well as available incentive and rebate programs. The review identifies challenges, barriers, and opportunities associated with large-scale deployment of cool surfaces and categorize them broadly as being related to product development & performance or policies & mandates. It provides a foundation upon which we intend to build a roadmap for rapidly accelerating future deployments of cool surfaces. Finally, this roadmap will address identified challenges and incorporate lessons learned from historical efforts to generate a practical and actionable plan.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of Mk-IV and EBR-II X441A Metallic Fuel Pins for the THOR-C-2 and THOR-M-TOP-1 Experiments: Results from Post-Transient Neutron Tomography of THOR-C-2 Capsule and Pre-transient Non-Destructive and Destructive Examination of DP 36 and DP 40 (Rev.1)

Current interest in sodium-cooled fast reactor designs, such as TerraPower’s Natrium Reactor, has highlighted the need for advanced-reactor fuel technology development. A Fuel Safety Research and Development (FSRD) program for metallic fast reactor fuels has been created to achieve comprehensive safety testing within the re-commissioned Transient Reactor Test (TREAT) facility at the Idaho National Laboratory. Despite over 60 years of metallic fuel irradiation, uncertainties exist in the performance of the fuel system, particularly under anticipated operational occurrences and severe accident scenarios. Throughout historical testing within the Experimental Breeder Reactor (EBR)-II and the Fast Flux Test Facility, fuel behavior has demonstrated benign response to transient reactor conditions; however, accurate predictions of failure thresholds rely heavily on fuel composition and irradiation history. In advancing the FSRD program, two planned transient heating experiments are at various stages of completion. The Temperature Heat sink Overpower Response (THOR)-C-2, fueled with an unirradiated Mk IV U-10Zr pin, has undergone transient irradiation in TREAT and post-transient three-dimensional neutron tomography. Additionally, pre-transient characterization of test and sibling U-19Pu-10Zr pins for THOR-M-TOP-1 was evaluated by both non-destructive and destructive methods. The test and sibling pins were selected from previously irradiated EBR-II experiment X441A. Both pins underwent visual examination, precise gamma spectrometry, two-dimensional neutron radiography, and element contact profilometry while the sibling pin was additionally subjected to sectioning and optical microscopy. THOR-C-2 radiography captured the fuel and cladding relocation during the intermediate transient at the top and bottom of the THOR capsule, allowing key features to be linked to the pin’s measured thermal response. For THOR M TOP 1, a solid baseline for steady-state behavior has been established. No anomalous features were identified in either the test or sibling pin. Defining characteristics and features were recorded for further comparisons.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal test plan for large variable conductance heat pipe

The procedure to be followed in determining the thermal performance of a variable conductance heat pipe is documented. The nominal one-inch-diameter aluminum pipe is of a cold reservoir type whose overall length is nine feet. It has a capacity of 2 to 4 kW's equivalent to 8 to 16 kW-ft and an overall temperature control range of 50 to 95 F. Initial tests will be conducted with the pipe charged with ammonia to determine its capacity limits. Following introduction of the noncondensible gas (nitrogen), the variable conductance features of the pipe will be used.

Edelstein, F.↗

Sub-Kelvin Cooling Systems for Quantum Computers

Future large-scale quantum processors (i.e. 100s of qubits), especially those based on superconducting circuits, will require large cooling powers (~10s of microW) at very low temperatures (<50 mK) with stringent temperature stabilities to avoid quantum decoherence and thus guarantee successful operation of such systems. One attractive option for providing this cooling is through Continuous Adiabatic Demagnetization Refrigerators (CADR). Scalable state-of-the-art CADRs at NASA's Goddard Space Flight Center have successfully shown to lift 6 W of heat at 50 mK with a 1 K temperature stability while rejecting its heat to a cryocooler at 4K. Carefully planned and proper heat sinking of cables, attenuators, and microwave components at various temperature stages (between 4K and base temperature) is critical in the cooling architecture of quantum computers and can be provided through proper staging of each unit within the CADR system. As an alternative method of cooling, dilution refrigerators with the potential to meet cooling requirements of emerging large-scale quantum processors are also discussed.

quantum cooling↗

Informing the planning of rotating power outages in heat waves through data analytics of connected smart thermostats for residential buildings

Abstract With climate change, heat waves have become more frequent and intense. Rotating power outages happen when the power supply is unable to meet the cooling demand increase resulting from extreme high temperatures. Power outages during heat waves expose residents to high risks of overheating. In this study, we propose a novel data-driven inverse modelling approach to inform decision makers and grid operators on planning rotating power outages. We first infer the building thermal characteristics using the connected smart thermostat data, and used the estimated thermal dynamics to simulate the thermal resilience during a heat wave event. Our proposed method was tested for the California power outage in August 2020 by using the open source Ecobee Donate Your Data dataset. We found in California the power outage should not last more than two hours during heat waves to avoid overheating risks. Informing the residents in advance so they can prepare for it through pre-cooling is a simple but effective strategy to expand the acceptable power outage duration. In addition to assisting power outage planning, the proposed method can be used for other applications, such as to evaluate a building energy efficiency policy, to examine fuel poverty, and to estimate the load shifting potential of building stocks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

First heated jettison test on the Centaur standard shroud

The first in a planned series of heated jettison tests on the Centaur Standard Shround was conducted at NASA Plum Brook Station's Space Power Facility on November 19, 1973. The first 250-second portion of the test sequence involved heating the shroud with a specially-built fixture designed to provide a simulation of the heating environment encountered by the shroud during its ascent through the earth's atmosphere. The two heater halves, which were mounted on a rail system, were then retracted. This was followed by the jettison of the two shroud halves into catch nets positioned at 90 deg to the heater rails. The condition which made this test unique compared to the planned subsequent tests was the location of the maximum thermal line at 32 deg from the shroud separation plane. Information on the test hardware, configuration, and sequence is presented. Shroud thermal and deflection data encountered during the heating portion of the test sequence is compared with free-skin design temperatures in various graphical formats.

Source record↗

Asheville Urban Development II: Mapping Urban Heat to Support Cooling Initiatives and Climate Resilience Planning in the Greater Asheville Area

Asheville, North Carolina experiences the urban heat island effect, where temperatures in the city are higher than in surrounding rural areas. This effect intensifies with increased urbanization and less vegetative cover. Asheville’s urban heat island was exacerbated by population increases and tree cover decline, escalating the need for heat mitigation. We partnered with the City of Asheville’s Sustainability Department and Asheville GreenWorks whose actions prioritize sustainable city planning and equitable climate resilience. Using NASA Earth observations and ancillary datasets we spatially mapped urban heat, heat vulnerability, and cooling and adaptive capacity from 2019-2023. To map urban heat, we used Landsat 8 and 9 Operational Land Imager and Thermal Infrared Sensor for land surface temperature and albedo data and the ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station for evapotranspiration data. We assessed heat vulnerability using the urban heat data andthe Centers for Disease Control and Prevention’s Social Vulnerability Index. To evaluate cooling and adaptive capacity we used the InVEST Urban Cooling Model, integrating our heat vulnerability analysis with land use and cover data from Sentinel-1 Synthetic Aperture Rada rand Sentinel-2 Multispectral Instrument. Our results revealed distinct spatial patterns of urban heat, heat vulnerability, and cooling and adaptive capacity in Asheville with downtown as the focal hotspot and an outward decreasing radial pattern. These findings highlight targeted need for interventions to reduce heat impacts, address environmental injustices, and enhance climate resilience. Our project provided research to local organizations that can be used for heat mitigation in the greater Asheville area.

Authors not in NED but are confirmed contractors. ↗

Second heated jettison test on the Centaur standard shroud

The second in a planned series of heated jettison tests on the Centaur Standard Shroud was conducted on January 16, 1974. The first 250-second portion of the test sequence involved heating the shroud with a specially-built fixture designed to provide a simulation of the heating environment encountered by the shroud during its ascent through the earth's atmosphere. The two heater halves, which were mounted on a rail system, were then retracted. This was followed by the jettison of the two shroud halves into catch nets positioned at 90 deg to the heater rails. The condition which made this test unique compared to the others in the test series was the alignment of the maximum thermal line with the shroud separation plane. Information on the test hardware, configuration, and sequence is presented. Shroud thermal and deflection data encountered during the heating portion of the test sequence are compared with free-skin design temperatures in various graphical formats.

Source record↗

Design of Refractory Metal Life Test Heat Pipe and Calorimeter

Heat pipe life tests have seldom been conducted on a systematic basis. Typically, one or more heat pipes are built and tested for an extended period at a single temperature with simple condenser loading. Results are often reported describing the wall material, working fluid, test temperature, test duration, and occasionally the nature of any failure. Important information such as design details, processing procedures, material assay, power throughput, and radial power density are usually not mentioned. We propose to develop methods to generate carefully controlled data that conclusively establish heat pipe operating life with material-fluid combinations capable of extended operation. The test approach detailed in this Technical Publication will use 16 Mo-44.5%Re alloy/sodium heat pipe units that have an approximate12-in length and 5/8-in diameter. Two specific test series have been identified: (1) Long-term corrosion rates based on ASTM-G-68-80 (G-series) and (2) corrosion trends in a cross-correlation sequence at various temperatures and mass fluences based on a Fisher multifactor design (F-series). Evaluation of the heat pipe hardware will be performed in test chambers purged with an inert purified gas (helium or helium/argon mixture) at low pressure (10-100 torr) to provide thermal coupling between the heat pipe condenser and calorimeter. The final pressure will be selected to minimize the potential for voltage breakdown between the heat pipe and radio frequency (RF) induction coil (RF heating is currently the planned method of powering the heat pipes). The proposed calorimeter is constructed from a copper alloy and relies on a laminar flow water-coolant channel design to absorb and transport energy

Martin, J. J.↗

Fairfax County Urban Development: Identifying Urban Heat Mitigation Strategies for Climate Adaptation Planning in Fairfax County, Virginia

Extreme high temperatures lead to increased instances of cardiovascular disease, pulmonary disease, and even death, as well as increased energy consumption and infrastructure costs. People in urbanized areas experience higher temperatures than rural areas due to diminished vegetation and increased impervious surfaces which absorb and radiate heat. Fairfax County, Virginia has embarked on Resilient Fairfax, a program aimed at addressing climate adaptation and resilience. The DEVELOP team partnered with the Fairfax County Office of Environmental and Energy Coordination (OEEC) to assess the extent of the urban heat island effect on the county and its most vulnerable populations. The team used data from Landsat 8 Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS), as well as the ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS) for the years 2013 to 2021 and found that the hottest spots were in densely urbanized areas, with temperatures as much as 47°F above that of undeveloped reference areas. The team used the Integrated Valuation of Ecosystem Services and Tradeoffs (InVEST) urban cooling model and determined that areas with higher tree canopy cover had greater heat mitigation capacity. Estimates from the InVEST model showed that a 4.5% increase in canopy cover across the county could result in a temperature reduction of up to 2.4°F in some areas. The results will allow partners to assess heat distribution across Fairfax County and implement effective mitigation strategies, including locating prime locations for cooling centers and increasing canopy cover.

W. Pierce Holloway↗

Multi-objective Decisions on Integrated Energy Systems Planning and Operation for Industrial Combined Heat and Power Supply

Unlike the power sector—which can transmit electricity over long distances via established grids—the industrial sector poses a unique challenge due to its geographically concentrated large-scale heat processes. Enhancing energy security in such industrial parks provides a dual benefit: reduced exposure to volatile fossil fuel prices and improved economic viability, largely driven by economies of scale in energy supply and distribution. This study presents a comprehensive technoeconomic analysis of a nuclear energy hub, employing a mechanism-focused approach to evaluate uncertainties in operational strategies and capacity optimization. Load profiles from three major energy intesive industries—chemical, refinery, and steelmaking—are examined, each presenting unique challenges and opportunities for nuclear energy integration. We adopt a multi-objective optimization framework, converting multiple objectives into a single objective function through the e-constraint method. The findings highlight clear trade-offs between system conditions and varying levels of energy independence. Overall, this analysis is granular enough to address industry-specific concerns yet sufficiently generalizable to provide actionable insights into the feasibility of nuclear-based clean heat solutions for the industrial sector.

25 - ENERGY STORAGE↗

Radiant Heat Test Facility (RHTF): User Test Planning Guide

Test process, milestones and inputs are unknowns to first-time users of the RHTF. The User Test Planning Guide aids in establishing expectations for both NASA and non- NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

DelPapa, Steven↗

Improving energy efficiency while reducing anthropogenic heat from buildings: how retrofits influence the building stock and urban microclimate in Los Angeles

Anthropogenic heat (AH) from buildings contributes to urban overheating, especially during heat waves, yet building retrofit studies usually evaluate energy savings without assessing impacts on AH. This study quantifies how common building retrofit measures affect both building energy use and AH emissions across the City of Los Angeles. Using a bottom-up urban building energy modeling framework coupled with high-resolution local weather from the Weather Research and Forecasting model with Building Effect Parameterization (WRF-BEP), we evaluate eleven retrofit measures and two multi-measure retrofit packages. HVAC and LED lighting retrofits provide the largest city-wide annual site energy savings, while roof coating is most effective for reducing AH. A package optimized for energy savings reduces summer site energy use by about 32% (2.3 TWh), while a package incorporating AH-focused measures reduces the total AH by over 50% (137 PJ) with minimal difference in energy savings. The AH-aware package produces substantially greater urban cooling, reducing mean near-surface air temperature by up to 0.62 ℃ and peak temperature by up to 3.79 ℃. These results show that retrofit strategies selected only for energy savings may overlook major opportunities for urban heat mitigation. The study provides a framework for integrating AH into building retrofit planning and urban heat resilience policy.

Anthropogenic heat↗

Heat Pump Retrofits for Central Plant Hydronic Heating Systems: A Software Toolkit for Screening and Design

Retrofitting existing central plants with high-efficiency heat pump technologies can play a crucial role in achieving long-term planning goals. Modern heat pump technologies are able to use waste heat recovery to meet a building's heating demand, but there is a lack of accessible tools designed for non-HVAC experts, such as building owners, to quickly and easily conduct what-if analysis, e.g., estimating retrofit costs and payback period for their partial or full equipment replacement. This paper introduces an open-source software toolkit designed to facilitate the initial screening and decision-making of heat pump retrofits in existing central plants using a building's yearly load profile from metered or utility bill data. The toolkit evaluates the technical and economic viability of replacing traditional central plant equipment with various options including water-to-water or air-to-water heat pumps, which can provide efficient and lower-cost heating and cooling. It allows users to compare current central plant configurations with retrofit scenarios, assessing energy consumption, life-cycle costs, and environmental impact. The toolkit offers (1) a web-based tool designed for user-friendly access by a broad audience and (2) Python-based source code for researchers and engineers conducting parametric studies and design parameter optimization. The toolkit compares a typical central plant configuration to a configuration that uses a heat pump to supply hydronic heating and cooling. The output metrics include energy consumption and output of each equipment, life-cycle cost analyses and metrics, and environmental impact of the system.

Excell, L↗