Search NASA⌕ Search

SEARCH · Search NASA

Results for “heat pumps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Techno-Economic Analysis and Market Potential of Geological Thermal Energy Storage (GeoTES) Charged With Solar Thermal and Heat Pumps into Depleted Oil/Gas Reservoirs and Shallow Reservoirs: A Technology Overview: Preprint

Depleted oil/gas reservoirs represent a waste of underground resources and investments of drilling, and also a potential risk to the earth's environment. Geologic thermal energy storage (GeoTES) is proposed as a solution to convert depleted oil/gas reservoirs into long-term seasonal energy storage. GeoTES can be hybridized with other techniques for viable commercial deployment, such as 1) concentrating solar power (CSP) collectors and 2) heat pumps with excess renewable energy. Here, a technology overview is given on the two GeoTES technologies, which includes system overview, techno-economic models, and case study. Both GeoTES technologies show great potential in the economics of individual project deployment and applicability across the US.

concentrating solar power↗

Development and Testing of an Advanced Cascaded Thermoelectric Residential Heat Pump

Electricity-driven heat pumps using vapor compression cycle are an energy-efficient solution to replace fossil fuel burning and reduce greenhouse gas emissions for space heating in residential buildings. However, heating capacity and Coefficient of Performance (COP) of heat pumps degrade significantly with increasing temperature difference between ambient and indoor environments. Residents and building owners are hence reluctant to fully embrace electric heat pumps. The use of conventional all-electric heat pumps also causes concern for electric utilities due to an increased winter peak demand arising from the use of supplemental electric resistance heaters. Our research is an attempt to alleviate these concerns by designing and laboratory testing a thermoelectric (TE) heat pump cascaded with a vapor compression cycle to enhance heating capacity and COP. TE modules increase the subcooling in the refrigerant liquid of the vapor compression cycle to enlarge the evaporating capacity and works at an efficiency greater than a conventional electric resistance strip. This results in a simple, affordable, efficient and highly controllable solution to adequately meet space heating needs in dwellings. The laboratory testing of the 3-stage cascaded TE heat pump performed in this research has exhibited a higher heating capacity by above 15%, while maintaining a heating COP of 2.0-3.6 in the ambient temperature range of -18˚C to 8˚C (0˚F to 47 ˚F), which represents more than 60% of winter temperatures observed in US. If successfully commercialized, this technology can advance space-heating electrification by overcoming consumer cost barrier of heat pumps.

Shen, Bo↗

Field Test and Thermal Performance Comparison of a Novel Underground Thermal Battery with a Single U-tube Borehole Heat Exchanger for Geothermal Heat Pump Application

Geothermal Heat Pumps (GHP) are a proven technology to electrify and decarbonize space heating and cooling by utilizing the thermally consistent underground as a heat sink or source. However, the high drilling costs of conventional borehole heat exchangers (BHEs) associated with GHP systems and subsurface heterogeneity have been two major challenges to their widespread adoption. In this paper, we present results from a field-scale pilot of an Underground Thermal Battery (UTB) as a potential alternative to a conventional BHE. To benchmark the UTB performance, a side-by-side field test was conducted to compare the UTB with a conventional BHE installed at the same site. The UTB was installed in a 7.01-meter-deep borehole having a diameter of 0.9 meter, whereas the conventional BHE (with single U-tube loop) is in a borehole with 36.6-meter depth and 0.15-meter diameter. Both are integrated into a GHP system to meet the thermal energy demands of office space at the Illinois Energy Farm on the University of Illinois Urbana-Champaign campus. The system’s performance is compared in terms of heat transfer rate, outlet temperatures, and contributions to the overall thermal power of the GHP system under varying thermal demands and in different heat pump operation modes: heating only, cooling only, and hybrid (alternative, diurnal heating and cooling). Results to date indicate that the UTB delivers a more consistent response under during a time period of varying thermal demands. Its operational performance is better during short-term with higher thermal demands, while the conventional BHE performs better under continuous, long-term thermal demands.

Pokhrel, Sajjan [ORNL] (ORCID:0000000228523749)↗

Energy Data from Heat Pumps Installed in Juneau, AK

Heat pumps offer a great low carbon emission method to heat homes. Thermalize Juneau 2021 was a clean energy campaign that helped homeowners in Juneau, Alaska install heat pumps into their homes. Juneau is located near the climactic limit of many heat pumps, and we were interested in how well the heat pumps can function in cold climates. This was done by using Sense meters to remotely monitor the energy usage of 10 homes with heat pumps. The Sense meters are small devices that connect to the electrical panel and monitor the energy use of multiple appliances through machine learning. First, we recorded the energy usage of a heat pump in the lab using both the Sense meter and the existing lab datalogger. Both recorded very similar energy usage data which confirmed that the Sense meter can accurately measure the fluctuations in the heat pump energy use. Next, we looked at the energy data from the Sense meters in the homes with heat pumps and paired it with local weather data to see how well the heat pumps functioned in the cold weather.

Alaska↗

Modelling and Simulation of a Thermoelectric Heat Pump with Micro-Channel Heat Transfer

Thermoelectric heat pumps (TEHPs) have advantages of modularity and simple design for heating and cooling in some applications. Models of thermoelectric (TE) heat pumps are widely studied. Nevertheless, most existing modeling work focuses on the TE material or air-sourced TE modules. TEHP modeling, especially the relationship between modules and heat exchangers, has not been comprehensively conducted. This work presents a water-to-water TEHP modeling framework that combines Goldsmid’s approach for TE material performance, Gnielinski’s correlation for convective heat transfer, and thermal balance theory for heat exchange networks. This combined framework provides an accurate theoretical analysis of the water-to-water TEHP system. Subsequently, the framework was used to empirically determine TE material properties (electric resistivity, thermal conductivity, and Seebeck coefficient) that minimize modeling errors versus experimentally observed values from the literature. Finally, an additional set of experimental TEHP data was used to validate the model, all with relative absolute deviations of approximately 10% when predicting heating capacity and 10%–20% when forecasting cooling capacity at a 30 K temperature lift. For future work, people can further develop models of TEHPs with an air-based heat sink on one side and water channels on the other side.

Wan, Hanlong↗

Searching for eco-friendly working fluids for an ejector-driven heat pump for domestic water heating

This study searches for refrigerants with low global warming potential (GWP) and zero ozone depletion potential (ODP) for an ejector heat pump water heater (EHPWH). Several criteria are set, and R1336mzz(Z), R601a, R1233zd(E), R1224yd(Z), R1234ze(Z), and R600a are shortlisted. A theoretical model is built to study the performance of EHPWH and the corresponding ejector design at different operating conditions. For the same ejector design, a refrigerant with a high specific heat ratio produces a high entrainment ratio and heating COP. This is because the expansion wave angle in the ejector is small for refrigerants with a high specific heat ratio, allowing more mass flow rate to be entrained. A higher entrainment ratio does not necessarily correlate to a high COP because the saturation curve of the tested refrigerants is not the same. Results show that the heating COP of R601a is the highest, but it is extremely flammable. R1224yd(Z) and R1234ze(Z) are the most candidates for EHPWH when the trade-off between the COP and safety criteria is considered. The results presented in this work could help building an EHPWH using eco-friendly refrigerants.

Mohammed, Ramy H.↗

Heat Transfer, Refrigeration and Heat Pumps

The Special Issue entitled “Heat Transfer, Refrigeration and heat Pumps” accepted papers covering a wide range of topics related to heat pumps, thermal energy storage, and low-Global Warming Potential (GWP) alternative refrigerants. Heat pumps play a vital role in providing space conditioning and water heating while utilizing the energy of the environment. Since heat pumps use renewable thermal energy from the environs to provide the desired utility, they contribute to the portfolio of technologies that mitigate carbon footprint. The heat pump may be considered a truly renewable technology if the electricity it uses comes entirely from a renewable source. More accurately, a heat pump is a “low carbon technology”. These perspectives make heat pumps an indispensable option for the future in order to reduce the nocuous human impact on the environment. More efficient heat pumping technologies are being developed for the residential, commercial, and industrial sectors of the economy. Another R&D thrust is heat pumps for cold climates. Hardware components, use of low-GWP refrigerants, and identification of systemic inefficiencies are active research areas. This article is a synopsis of the papers submitted to the Special Issue.

42 ENGINEERING↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units

The heat pump rooftop units (RTUs) measure replaces gas furnace and electric resistance RTUs with high-efficiency heat pump rooftop units (HP-RTUs). The HP-RTUs are intended to be top-of-the line, including high-efficiency fans and heat pump systems. The fans are variable speed, allowing the HP-RTUs to operate as single-zone variable air volume systems. The heat pumps are also variable speed, allowing for high part load performance. All schedules in the existing RTUs are transferred to the new HP-RTUs for consistency. Furthermore, any energy efficiency features in the existing baseline RTUs such as energy recovery or economizers are also transferred to the new HP-RTUs for consistency. This measure is applicable to approximately 45% of the ComStock floor area. The HP-RTU measure demonstrates 10.3% total site energy savings (449 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Method and device for controlling heat pump

A method for controlling a heat pump is provided. A working mode of the heat pump is determined. Based on a determination that the working mode of the heat pump is a heating mode, an ambient temperature of the heat pump is determined. Based on a determination that the ambient temperature of the heat pump is higher than a first predetermined temperature, a first compressor of the heat pump is operated. Based on a determination that the ambient temperature of the heat pump is lower than the first predetermined temperature, both the first compressor and a second compressor of the heat pump are enabled to operate, in response to a two-stage thermostat. The first compressor and the second compressor are coupled in parallel. The method allows the heat pump to be suitable for a cold climate.

42 ENGINEERING↗

Model-Based Investigation of Multi-Fault Interactions and Performance Degradation in Residential Heat Pump Systems

Faults in heat pump systems can significantly degrade performance, reduce efficiency, and accelerate component wear, leading to higher operating costs and maintenance demands. While numerous studies have investigated the impact of individual faults, the interactions between multiple concurrent faults remain insufficiently understood, despite their common occurrence in real-world operation. This study conducts a comprehensive simulation analysis of multiple simultaneous faults in a vapor compression heat pump using a validated heat pump design model (HPDM) tool. Detailed component-level modeling methods are implemented to examine performance sensitivity under combinations of refrigerant flow and heat exchanger faults. The results reveal complex fault interactions that can mask or amplify system deviations, challenging conventional diagnostic approaches. Findings from this work provide meaningful insights for the development of more robust fault detection and diagnosis algorithms, supporting improved reliability and energy efficiency in next-generation heat pump technologies.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Model Predictive Control for a Grid-interactive Efficient Thermal Storage-integrated Heat Pump System

Building heating and cooling systems can be used to overcome the mismatch between the intermittent supply of renewable power and the fluctuating demand for electricity. A novel underground thermal energy storage integrated with a dual-source heat pump has been proposed to mitigate the mismatch while meeting the thermal demand of buildings efficiently. Conventional thermostat control with heuristic rules cannot provide intelligent decisions to maximize the thermal efficiency and flexibility of the proposed system. Advanced control strategies like model predictive control (MPC) have provided a new paradigm for grid-interactive efficient building operation with the advancement of computation and sensing. This study developed an MPC for the proposed system to provide grid service for Demand Side Management and minimize the operating cost of building owners. A control-oriented dynamic model of the proposed system has been developed. Given an objective function and proper constraints, an optimization problem is formulated to determine the optimal control strategy of the system. Dynamic Programming is adopted to solve the optimization problem. A rule-based control (RBC) is also developed to achieve similar goals. Short-term simulations are conducted to compare the system performance resulting from the two controls. The simulation results indicate that the MPC performs more intelligently than the RBC in charging thermal energy storage and selecting heat pump sources by taking advantage of the predicted cooling demands of the building and the performance of the integrated system. As a result, the MPC could save energy and reduce operating costs compared with the RBC. A case study shows that, for a 3-day operation, the MPC saves 36.9% energy and reduces 38.5% operating cost compared with the RBC.

Shi, Liang↗

Peak Reduction Using Mode Adjustment of Heat Pump Water Heaters in a Residential Neighborhood

Building electrification is putting pressure on distribution grid worldwide. Peak reduction is an important concern that can help reduce the growing stress and allow to defer investments in new capacity. Water heaters represent a convenient way of reducing peak because they are less dependent on weather, and their storage volume allows for asynchronous water heating and hot water use. Previous empirical studies investigated the ability of water heaters to reduce peak through the adjustment of the temperature setpoint. However, not all equipment vendors offer this option. This study aims at understanding the feasibility of peak reduction with an alternative configuration available in the market - by adjusting the device mode rather than temperature setpoint. The peak reduction methodology is tested in an occupied 46-townhome neighborhood located in Atlanta, GA. We find that peak shifting is possible with the adjustable mode approach, with the change in the peak load by 30-60%.

demand response↗

Energy and Exergy Analysis of Low-Global Warming Potential Refrigerants as Replacement for R410A in Two-Speed Heat Pumps for Cold Climates

Heat pumps (HPs) are being developed with a new emphasis on cold climates. To lower the environmental impact of greenhouse gas (GHG) emissions, alternate low global warming potential (GWP) refrigerants must also replace the exclusive use of the refrigerant R410A, preferably without re-engineering the mechanical hardware. In this paper, we analyze the performance of four low-GWP alternative refrigerants (R32, R452B, R454B, and R466A) relative to the conventional R410A and draw conclusions on the relative performances for providing heating in cold climates based on the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) 210/240 standard for two-speed heat pumps. The simulations are carried using the Department of Energy, Oak Ridge National Laboratory (DOE/ORNL) Heat Pump Design Model (HPDM), a well-known heating, ventilation, and air conditioning (HVAC) modeling and design tool in the public domain and the HVAC research and development community. The results of the simulation are further scrutinized using exergy analysis to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate low-GWP refrigerants to replace R410A using available compressors and system components, without compromising performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗