Experimental investigation to simulate propellant heating in the nuclear light bulb engine.
Experiments to heat a simulated propellant to high bulk temperatures by the absorption of thermal radiation are discussed. Argon seeded with micron-sized carbon particles was used as the simulated propellant; a 500 kw d-c arc was used as the radiant energy source. Bulk temperatures up to 3860 K were obtained with greater than 95% of the incident radiation absorbed. The arc radiation source, seed dispersal equipment, techniques used to prevent transparent wall coating by the seeds, and calorimetric measurement of bulk temperature are also discussed.
General Purpose Heat Source Simulator
The General Purpose Heat Source (GPHS) simulator project is designed to replicate through the use of electrical heaters, the form, fit, and function of actual GPHS modules which generate heat through the radioactive decay of Pu238. The use of electrically heated modules rather than modules containing Pu238 facilitates the testing of spacecraft subsystems and systems without sacrificing the quantity and quality of the test data gathered. Previous GPHS activities are centered around developing robust heater designs with sizes and weights that closely matched those of actual Pu238 fueled GPHS blocks. These efforts were successful, although their maximum temperature capabilities were limited to around 850 C. New designs are being pursued which also replicate the sizes and weights of actual Pu238 fueled GPHS blocks but will allow operation up to 1100 C.
Experimental aerodynamic heating to simulated shuttle tiles
The heat transfer to simulated shuttle thermal protection system tiles was investigated experimentally using a highly instrumented metallic thin wall tile arranged with other metal tiles in a staggered tile array. Cold-wall heating rate data for laminar and turbulent flow were obtained in the Langley 8-foot high temperature tunnel at a nominal Mach number of 7, a nominal total temperature of 3300 R, free-stream unit Reynolds number from 3.4 x 10 to the 5th power to 2.2 x 10 to the 6th power per foot, and free-stream dynamic pressure of 1.8 psia to 9.1 psia. Experimental data are presented to illustrate the effects of flow angularity and gap width on both local peak heating and overall heating loads.
Experimental aerodynamic heating to simulated Shuttle tiles
The heat transfer to simulated Shuttle thermal protection system tiles was investigated experimentally using a highly instrumented metallic thin wall tile arranged with other metal tiles in a staggered tile array. Cold-wall heating rate data for laminar and turbulent flow were obtained in the Langley 8-Foot High-Temperature Tunnel at a nominal Mach number of 7, a nominal total temperature of 3300 deg R, free-stream unit Reynolds number from 340,000 to 2,200,000 per foot, and free-stream dynamic pressure of 1.8 to 9.1 psia. Experimental data are presented to illustrate the effects of flow angularity and gap width on both local peak heating and overall heating loads.
Effects of the heat source on the steady-state transport in gradient-driven global gyrokinetic simulations
Heat sources are routinely used in gradient-driven global gyrokinetic simulations to prevent profile relaxation and ensure steady-state turbulence and transport. To have any predictive capability, gradient-driven simulations need to be insensitive to the particular choice of a source. Several forms of the heat source are investigated using gyrokinetic δf particle-in-cell simulations. The ion heat flux is found to be sensitive to the source strength when the source rate is below a fraction (∼1/10) of the linear growth rate.
General Purpose Heat Source Simulator
The General Purpose Heat Source (GPHS) project seeks to combine the development of an electrically heated, single GPHS module simulator with the evaluation of potential nuclear surface power systems. The simulator is designed to match the form, fit, and function of actual GPHS modules which normally generate heat through the radioactive decay of Pu238. The use of electrically heated modules rather than modules containing Pu238 facilitates the testing of the subsystems and systems without sacrificing the quantity and quality of the test data gathered. Current GPHS activities are centered on developing robust heater designs with sizes and weights which closely match those of actual Pu238 fueled GPHS blocks. Designs are being pursued which will allow operation up to 1100 C.
A fast and accurate modeling approach for water and steam thermodynamics with practical applications in district heating system simulation
In U.S. district heating (DH) systems, steam is the most common heat transport medium. Industry demand for new advanced modeling capabilities of complete steam DH systems is increasing; however, the existing models for water/steam thermodynamics are too slow for large system simulations because of computationally expensive algebraic loops that require the solution to nonlinear systems of equations. For practical applications, this work presents a novel split-medium approach that implements numerically efficient liquid water models alongside various water/steam models, breaking costly algebraic loops by decoupling mass and energy balance equations. New component models for steam DH systems are also presented. We implemented the models in the equation based Modelica language and evaluated accuracy and computing speed across multiple scales: from fundamental thermodynamic properties to complete districts featuring 10 to 200 buildings. Compared to district models with the IF97 water/steam model and equipment models from the Modelica Standard Library, the new implementation improves the scaling rate for large districts from cubic to quadratic with negligible compromise to accuracy. Additionally, for an annual simulation with 180 buildings, this translates to a computing time reduction from 33 to 1-1.5 h. These results are critically important for industry practitioners to simulate steam DH systems at large scales.
Coupled Multiphysics Simulations of Heat Pipe Microreactors Using DireWolf
DireWolf is a multiphysics software driver application designed to simulate heat pipe–cooled nuclear microreactors. Developed under the U.S. Department of Energy, Office of Nuclear Energy Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, the DireWolf software application’s objective is to provide the nuclear community with a design and safety analysis simulation capability. Based upon the NEAMS program Multiphysics Object-Oriented Simulation Environment (MOOSE) computational framework, DireWolf tightly couples nuclear microreactor physics, reactor physics, radiation transport, nuclear fuel performance, heat pipe thermal hydraulics, power generation, and structural mechanics to resolve the interdependent nonlinearities. DireWolf is capable of simulating both steady and transient normal reactor operation and several postulated failure scenarios. We will present the fundamental physics of heat pipe–cooled nuclear microreactors and the MOOSE-based software employed in DireWolf. Both steady and transient results for coupled reactor physics, radiation transport, and nuclear fuel performance are demonstrated.
An investigation of some mechanical and thermal properties of lunar simulant materials heated at 2.45 GHz
Lunar simulant material was fabricated to simulate Apollo 11, Apollo 15, and Apollo 16 soils. The approximate compositions which these soils simulate are given. Samples of each soil simulate were fabricated into right circular cylinders, placed into a microwave reaction cavity, and heated using 2.45 GHz radiation to a particular processing temperature at which it was held for a prescribed length of time. Examples are given of two microwave heating programs for these simulant samples. Upon completion of thermal processing, each sample had its top and bottom surfaces polished. A technique was employed which looks at hardness data to determine the fracture toughness of a material and then relates this to thermal shock resistance. Some advantages of this technique are its low cost for analysis and thermal shock resistance as a function of initial sample orientation in the microwave field can be determined. Samples were prepared for testing and results are expected. At the same time, other samples are currently being investigated using scanning electron microscopy to determine their microstructures.
A Radiant Heater to Simulate Aerodynamic Heating in a Wind Tunnel
A recently developed radiant-heating test technique for simulation of aerodynamic heating in wind tunnel is describes. The heating device, which utilized quartz-tube lamps, was operated successfully while exposed directly to a supersonic airstream. Tests were made on a calibration panel, and experimental temperature and pressure data are presented. Results indicate that initial heating rates of about 26 Btu/(sq ft) (sec) are obtainable at a distance of 12 inches from the heater. Further applications of the basic design are discussed briefly.
Isotope heat source simulator for testing of space power systems
A reliable isotope heat source simulator was designed for use in a Brayton power system. This simulator is composed of an electrically heated tungsten wire which is wound around a boron nitride core and enclosed in a graphite jacket. Simulator testing was performed at the expected operating temperature of the Brayton power system. Endurance testing for 5012 hours was followed by cycling the simulator temperature. The integrity of this simulator was maintained throughout testing. Alumina beads served as a diffusion barrier to prevent interaction between the tungsten heater and boron nitride core. The simulator was designed to maintain a surface temperature of 1311 to 1366 K (1900 to 2000 F) with a power input of approximately 400 watts. The design concept and the materials used in the simulator make possible man different geometries. This flexibility increases its potential use.
Simulated nuclear heating of liquid hydrogen in a propellant tank
Simulated nuclear heating of liquid hydrogen in propellant tank
Glenn Heat Transfer Simulation and Solver Graphical User Interface: Development and Testing
In the Tui ine Branch of the Turbomachinery and Propulsion Systems Division, researching and developing efficient turbine aerothermodynamics technologies is the main objective. Creating effective turbines for jet engines is a process which, if based purely on physical experimental testing, would be extremely expensive. It is for this reason, and also for the reasons of speed and ease, that the Turbine Branch spends a large amount of effort working with simulations of turbines. Specifically, they focus their work on two main fields: Computational Field Dynamics (CFD), and Experimental data analysis. The experimental field involves comparing experimental results to simulated results, whereas the CFD field involves running these simulations. The simulations are applied to aerodynamics and heat transfer cases, for both steady and unsteady flow conditions. By and large this work is applied to the domain of flow and heat transfer in axial turbines. The main application used to run these heat flow simulations is GlennHT. This program, recently rewritten in FORTRAN 90, allows the user to input a job file which specifies all the necessary parameters needed to simulate flow through a user-defined grid. There are several other executables used as well, ranging in application from converting grid files to and from particular formats, to merging blocks in a connectivity file, to converting connectivity files to a GlennHT compatible format. All of these executables are run from the command line in a terminal; some of them have interactive prompts where the user must specify the files to be manipulated after the program starts, while others take all of their parameters from the command line. With this amount of variation comes a good deal of commands and formats to memorize, which can cause slower and less efficient work, as users may forget how to execute a certain program, or not remember the pathnames of the files they wish to use. Two years ago, steps were made to expedite this process with a graphical user interface (GUI) that combines the functionality of all the executables along with adding some new functionality, such as residuals graphing and boundary conditions creation. Upon my beginning here at Glenn, many parts of the GUI, which was developed in Java, were nonfunctional. There were also issues with cross-platforming, as systems in the branch were transitioning from Silicon Graphics (SGI) machines to Linux machines. My goals this summer are to finish the parts of the GUI that are not yet completed, fix parts that did not work correctly, expand the functionality to include other useful features, such as grid surface highlighting, and make the system compatible with both Linux and SGI. I will also be heavily testing the system and providing sufficient documentation on how to use the GUI, as no such documentation existed previously.
SIMULATION OF CONVECTIVE AND RADIATIVE ENTRY HEATING
Description of ames entry heating simulator, a facility which is capable of simulating both the convective and radiative modes of heat transfer
A computer program for the simulation of heat and moisture flow in soils
A computer program that simulates the flow of heat and moisture in soils is described. The space-time dependence of temperature and moisture content is described by a set of diffusion-type partial differential equations. The simulator uses a predictor/corrector to numerically integrate them, giving wetness and temperature profiles as a function of time. The simulator was used to generate solutions to diffusion-type partial differential equations for which analytical solutions are known. These equations include both constant and variable diffusivities, and both flux and constant concentration boundary conditions. In all cases, the simulated and analytic solutions agreed to within the error bounds which were imposed on the integrator. Simulations of heat and moisture flow under actual field conditions were also performed. Ground truth data were used for the boundary conditions and soil transport properties. The qualitative agreement between simulated and measured profiles is an indication that the model equations are reasonably accurate representations of the physical processes involved.
Advanced thermal energy management: A thermal test bed and heat pipe simulation
Work initiated on a common-module thermal test simulation was continued, and a second project on heat pipe simulation was begun. The test bed, constructed from surplus Skylab equipment, was modeled and solved for various thermal load and flow conditions. Low thermal load caused the radiator fluid, Coolanol 25, to thicken due to its temperature avoided by using a regenerator-heat-exchanger. Other possible solutions modeled include a radiator heater and shunting heat from the central thermal bus to the radiator. Also, module air temperature can become excessive with high avionics load. A second preoject concerning advanced heat pipe concepts was initiated. A program was written which calculates fluid physical properties, liquid and vapor pressure in the evaporator and condenser, fluid flow rates, and thermal flux. The program is directed to evaluating newer heat pipe wicks and geometries, especially water in an artery surrounded by six vapor channels. Effects of temperature, groove and slot dimensions, and wick properties are reported.
Simulated isotope heat source for use in Brayton power system
Nondestructive tests of simulated isotope heat source for use in Brayton power system