Search NASA⌕ Search

SEARCH · Search NASA

Results for “heavy ion beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

High-rate heavy-ion tracking using MWPCs and PPACs with an Anti-Discharge Unit

This work reports on the development of two robust, heavy-ion beam tracking concepts operating at low pressure (< 15 Torr) for high rate applications (> 200 kHz). The first concept consists of a Multi-Wire Proportional Counter (MWPC) with a central anode consisting of 12 μm Au-plated Tungsten wires spaced 1 mm from each other. The anode grid is sandwiched between two segmented cathodes aligned orthogonally in the two dimensions for (x,y) particle localization. The second detector is a Parallel-Plate Avalanche Counter (PPAC) that uses the same readout geometry as the MWPC, but replaces the wire anode with a 150 nm silver layer deposited on both sides of a thin (< 1 mg/cm 2 ) polypropylene foil. Additionally, the bias circuitry for the PPAC anode central foil is equipped with an Anti-Discharge Unit (ADU) to prevent transitions from proportional operation to streamer formation, thereby avoiding damaging discharges. The localization capability of both detectors was tested with a low-rate alpha-particle source (241-Am). A position resolution of < 1 mm (FWHM) was achieved under stable, high-gas-gain (> 1000) operating conditions. Their performance in terms of detection efficiency as a function of the isotope charge (Z) was determined by irradiating the detectors with a cocktail beam (Z ≤ 15) with energy of ∼ 100 MeV/u. Full detection efficiency is maintained for all available fragments under optimal operational conditions (i.e., voltage bias). Full detection efficiency was achieved at rates above 200 kHz by irradiating the detectors with a 1 cm diameter 238 U beam at an energy of 143 MeV/u.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DESIGN AND MEASUREMENT OF THE 1.4 GHZ CAVITY FOR LEReC LINAC

The Low Energy RHIC electron Cooler (LEReC) is the first electron cooler based on rf acceleration of electron bunches. To further improve RHIC luminosity for heavy ion beam energies below 10 GeV/nucleon, a normal conducting RF cavity at 1.4 GHz was designed and fabricated for the LINAC that will provide longer electron bunches for the LEReC. It is a single cell cavity with effective cavity length shorter than half of the 1.4 GHz wavelength. This cavity was fabricated and tested on site at BNL to verify RF properties, i.e. the resonance frequency, fundamental power coupler (FPC) coupling strength, tuner system performance, and high-power tests. In this paper, we report the RF test results for this cavity.

43 PARTICLE ACCELERATORS↗

Ion Generation Using Frozen Xenon Target for Laser Ion Source

A frozen laser target that is in the gaseous phase at room temperature is advantageous for a laser ion source because it can avoid the accumulation of damage from laser irradiation by regeneration of the target surface by additional gas freezing. In this study, the possibility of forming a xenon ion beam with a current sufficient for heavy-ion inertial fusion (HIF) was investigated. The relationship between the frozen target growth and resulting ion current was analyzed to determine the optimal condition of laser irradiation that ensures stable supply of ion beams for a long time. A frozen target of xenon was formed on a mount cooled to 20 K using a Gifford McMahon cryocooler, and plasma was generated using a Nd:YAG laser. Here, the results showed that it is possible to supply a sufficient ion current for application of singly charged ions as a driver for HIF. Additionally, it was indicated that the xenon responsible for forming the plasma existed only at a certain depth from the target surface. The results imply that it is possible to obtain a stable ion supply for a long time by irradiating the target with a laser after the frozen xenon grows to a sufficient thickness.

43 PARTICLE ACCELERATORS↗

Image mapping for multiple charge state beams using a beam induced fluorescence profile monitors

Work continues on a minimally invasive, nitrogen fluorescence gas sheet at the Facility for Rare Isotope Beams (FRIB). A low density gas sheet may be used to observe the 2D transverse beam profile of high intensity, multiple charge state beams with minimal interference. Spatially and temporally correlated profiles are of particular interest in locations where there is significant charge state spread, such as the FRIB linac folding segments. A low-density gas sheet measurement system offers advantages for gas handling in nitrogen sensitive areas, however signal intensity is significantly lower than techniques using higher density gas sheets and jets. This work discusses measurement considerations for photon distributions generated by several spatially separated interaction points and design considerations for a high-sensitivity optics system for handling the expected low signal intensity.

Accelerator Physics↗

AI-assisted transport of radioactive ion beams

Beams of radioactive heavy ions allow researchers to study rare and unstable atomic nuclei, shedding light into the internal structure of exotic nuclei and on how chemical elements are formed in stars. However, the extraction and transport of radioactive beams rely on time-consuming expert-driven tuning methods, where hundreds of parameters are manually optimized. Here, in this study, we introduce a system that employs Artificial Intelligence (AI), specifically utilizing Bayesian Optimization, to assist in the transport process of radioactive beams. We apply our methodology to real-life scenarios showing advantages when compared with standard tuning methods. This AI-assisted approach can be extended to other radioactive beam facilities around the world to improve operational efficiency and enhance scientific output.

43 PARTICLE ACCELERATORS↗

Monte Carlo simulation analysis for radiation damage on Glidcop Al-15 caused by 17-20 MeV/u heavy ions

The Facility for Rare Isotope Beams (FRIB) SRF linear heavy-ion accelerator is designed to accelerate all ions up to uranium to a maximum beam power of 400 kW. Several beam intercepting devices (BIDs) are essential to the successful operation of the accelerator, including a low power charge selector (LPCS) made of copper containing 0.15% precipitated aluminum oxide by weight called Glidcop Al-15. As FRIB ramps up the primary beam power beyond the current 20 kW level, the charge selector must withstand higher radiation damage rates, typically measured in displacements per atom (dpa). Significant beam induced radiation damage including significant deformation, like swelling, blistering, and cracking has been observed on a recently removed LPCS. We also observed physical features up to about 5.5 mm wide and appear to be deeper than the projected range of any ions. This paper presents the results of Monte Carlo simulations carried out using the Particle and Heavy Ion Transport code System (PHITS), quantifying the total damage dose and ion concentration, etc. Simulating an accurate irradiation history is essential to determining the scope of post irradiation examination (PIE) work.

Fletcher, Ethan [Michigan State U.]↗

Advanced Design for the WIQ Magnet With Steering Corrector Function

The Facility for Rare Isotopes Beams (FRIB) delivers heavy-ion primary beams at energies of up to 300 MeV/u at 10 kW of beam power to generate rare isotope beams for experiments and will eventually operate at beam power of 400 kW. The preseprator of the Advanced Rare Isotope Separator (ARIS) is equipped with six warm-iron quadrupole (WIQ) singlets and two dipoles integrated right after the production target. They have a compact structure and operate in a high radiation vacuum environment within a hot cell having remote handling capabilities for installation and maintenance. Due to asymmetry with respect to the quadrupole poles, nested sextupole excitations in WIQs induce vertical dipoles that offset the centroid trajectory; Magnet misalignments also result in trajectory offsets. Such offsets degrade separator performance but can be minimized by changing the current distribution on sextupole and octupole coils. In this work, we show how modifications to the WIQ coil design can allow superimposed dipole fields to be included to the octupole and sextupole windings, as well as addition of dipole components by splitting coil currents over groups with separator power supplies. Adjusting the group currents can cancel the sextupole-induced vertical dipole component which can be as high as 0.012 Tm. Octupole coil changes may superimpose a horizontal dipole integrated strength as high as 0.0332 Tm. Unwanted higher harmonics induced as a side effect of the new design are kept to a minimum such that separator performance is preserved as much as possible.

Accelerator magnets↗

Helium bubble nucleation and growth in alloy HT9 through the use of in situ TEM: Sequential he-implantation and heavy-ion irradiation versus dual-beam irradiation

The formation of He bubbles in Ferritic/Martensitic steel HT9 is investigated through the use of in situ Transmission Electron Microscopy coupled with He implantation and heavy ion irradiation. Of particular interest is the effect of increasing He appm/dpa ratio on the formation and growth of the bubbles, as well as the effect of the sequential order of ion irradiation i.e. He-pre-implantation followed by heavy-ion irradiation versus true dual-beam irradiation. Finally, the role of He is discussed.

Duemmler, Kai↗

Considerations on the design of a rare isotope beam facility based on superconducting heavy ion linacs

To establish an accelerator facility based on superconducting linear accelerator (linac) for nuclear and applied sciences in Korea, the rare isotope science project started in December 2011 under the auspices of the Institute for Basic Science (IBS). The layout of the facility has been mostly frozen since 2013 and civil construction began in 2016. On the other hand, an alternative linac design option was recently investigated in collaboration with the linac development group of Argonne National Lab in search of a further optimized configuration. A new linac lattice was developed and evaluated against realistic machine errors using TRACK. The beam optics simulations and error analysis then proved the soundness of this alternative design. In addition, beam optics of the injector was studied for simultaneous acceleration of both stable and rare isotope beams with the use of an electron beam ion source (EBIS). Additionally considered are alternative options of high-power cyclotrons as ISOL driver in order to enhance the capability of rare isotope beam production and fully exploit the superconducting linac facility built at high cost.

07 ISOTOPE AND RADIATION SOURCES↗

Viscosities of the Baryon-Rich Quark-Gluon Plasma from Beam Energy Scan Data

Here, this work presents the first Bayesian inference study of the (3 + 1)D dynamics of relativistic heavy-ion collisions and quark-gluon plasma viscosities using an event-by-event (3 + 1)D hydrodynamics + hadronic transport theoretical framework and data from the Relativistic Heavy Ion Collider Beam energy scan program. Robust constraints on initial state nuclear stopping and the baryon chemical potential-dependent shear viscosity of the produced quantum chromodynamic (QCD) matter are obtained. The specific bulk viscosity of the QCD matter is found to exhibit a preferred maximum around $\sqrt{s_{NN}}$ = 19.6 GeV . This result allows for the alternative interpretation of a reduction (and/or increase) of the speed of sound relative to that of the employed lattice-QCD based equation of state for net baryon chemical potential μ B ~0.2(0.4) GeV .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Halo removal experiments with hollow electron lens in the BNL Relativistic Heavy Ion Collider

A hollow electron beam has been proposed as an active control tool to remove the beam halo from high-energy, high-current hadron or ion machines (such as the High-Luminosity Large Hadron Collider). To study the halo removal rate and assess the effect on the ion beam core, one of the two electron lenses in the Relativistic Heavy Ion Collider was changed from a Gaussian beam profile to a hollow profile. We describe the design and verification of the hollow electron beam parameters as well as the methods to minimize the hollow beam profile distortions, which can result in an ion beam emittance increase. The hollow beam alignment with the ion beam by using a backscattered electron detector has been demonstrated. Furthermore, experiments were carried out to explore the efficiency of the halo removal by scanning the current and inner radius of the hollow electron beam, which is pulsed either every turn or every nth turn. The effects of the hollow electron beam on the ion beam emittance and luminosity were also assessed experimentally by scanning the inner radius of the electron beam.

43 PARTICLE ACCELERATORS↗

Commissioning of Extended Electron Beam Ion Source at Brookhaven National Laboratory

Here, the Extended Electron Beam Ion Source (EEBIS) has been installed and commissioned at Brookhaven National Laboratory (BNL) hadron accelerator complex in the spring of 2023. EEBIS has replaced its predecessor, RhicEBIS, which provided ions for BNL hadron facilities for over a decade since 2009. The motivations for the source upgrade are to provide higher intensities of the Au 32+ ion beam for the Relativistic Heavy Ion Collider (RHIC) and to provide of an intense source of polarized 3 He 2+ ions for the future Electron Ion Collider (EIC) at BNL. EEBIS is and will continue to be the primary source for a variety of different ion species for the NASA Space Radiation Laboratory (NSRL) at BNL. EEBIS utilizes two identical, two-meter-long unshielded 5T warm bore superconducting solenoids, and it is operated with electron beam current up to 10 A, providing a high-capacity ion traps to fulfill the requirement for high intensity ion beams. The upstream solenoid contains a “short ion trap” with a length of 95 cm, while the “long ion trap” with a length of 178 cm is located inside the downstream solenoid bore. The main features of EEBIS are: * A Gas injection and ionization cell equipped with a Lorenz pulse valve * High-capacity ZAO non-evaporable getter (NEG) custom linear pumping units * In situ apparatus for pumping speed measurements to monitor NEG activation and saturation * “External drift tube” construction with differential pumping stages to provide space for Lorentz pulse valve and 3 He high-field polarization cell * A Ba oxide electron gun cathode. The design of EEBIS as well as the results of its commissioning and first-year operation are presented and discussed.

43 PARTICLE ACCELERATORS↗

New proxies for second-order cumulants of conserved charges in heavy-ion collisions within the EPOS4 framework

Proxies for cumulants of baryon number 𝐵, electric charge 𝑄, and strangeness 𝑆 are usually measured in heavy-ion collisions via moments of net-number distribution of given hadronic species. Since these cumulants of conserved charges are expected to be sensitive to the existence of a critical point in the phase diagram of nuclear matter, it is crucial to ensure that the proxies used as substitutes are as close to them as possible. Hence, we use the EPOS 4 framework to generate Au + Au collisions at several collision energies of the BNL Relativistic Heavy Ion Collider beam energy scan. We compute second-order net cumulants of 𝜋, 𝐾, and 𝑝, for which experimental data have been published as well as the corresponding conserved charge cumulants. We then compare them with proxies, defined in previous lattice QCD and hadron resonance gas model studies, which are shown to reproduce more accurately their associated conserved charge cumulants. We investigate the impact of hadronic rescatterings occurring in the late evolution of the system on these quantities, as well as the amount of signal actually originating from the bulk medium which endures a phase transition.

Physics↗

Controlling superconductivity of CeIrIn 5 microstructures by substrate selection

Superconductor/metal interfaces are usually fabricated in heterostructures that join these dissimilar materials. A conceptually different approach has recently exploited the strain sensitivity of heavy-fermion superconductors, selectively transforming regions of the crystal into the metallic state by strain gradients. The strain is generated by differential thermal contraction between the sample and the substrate. Here, we present an improved finite-element model that reliably predicts the superconducting transition temperature in CeIrIn 5 even in complex structures. Different substrates are employed to tailor the strain field into the desired shapes. Using this approach, both highly complex and strained as well as strain-free microstructures are fabricated to validate the model. This enables a high degree of control over the microscopic strain fields and forms the basis for more advanced structuring of superconductors as in Josephson junctions yet also finds natural use cases in any material class in which a modulation of the physical properties on a chip is desirable.

36 MATERIALS SCIENCE↗

Global polarization of Λ and $\overline{Λ}$ hyperons in Au + Au collisions at $\sqrt{s_{NN}}$ = 19.6 and 27 GeV

In relativistic heavy-ion collisions, a global spin polarization, 𝑃 H , of Λ and $\overline{Λ}$ hyperons along the direction of the system angular momentum was discovered and measured across a broad range of collision energies and demonstrated a trend of increasing 𝑃 H with decreasing $\sqrt{s_{NN}}$. A splitting between Λ and $\overline{Λ}$ polarization may be possible due to their different magnetic moments in a late-stage magnetic field sustained by the quark-gluon plasma which is formed in the collision. The results presented in this study find no significant splitting at the collision energies of $\sqrt{s_{NN}}$ = 19.6 and 27 GeV in the BNL Relativistic Heavy Ion Collisions Beam Energy Scan Phase II using the STAR detector, with an upper limit of 𝑃 $\overline{Λ}$ – 𝑃 Λ < 0.24% and 𝑃 $\overline{Λ}$ – 𝑃 Λ < 0.35%, respectively, at a 95% confidence level. We derive an upper limit on the naive extraction of the late-stage magnetic field of 𝐵 < 9.4 × 10 12 T and 𝐵 < 1.4 × 10 13 T at $\sqrt{s_{NN}}$ = 19.6 and 27 GeV, respectively, although more thorough derivations are needed. Differential measurements of 𝑃 H were performed with respect to collision centrality, transverse momentum, and rapidity. With our current acceptance of |𝑦| < 1 and uncertainties, we observe no dependence on transverse momentum and rapidity in this analysis. Furthermore, these results challenge multiple existing model calculations following a variety of different assumptions which have each predicted a strong dependence on rapidity in this collision-energy range.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Demagnetization analysis of an 18 GHz electron cyclotron resonance ion source permanent magnet hexapole

An upgrade of ECR2 at the Argonne Tandem Linac Accelerator System is under way, focusing on increasing the intensity capabilities of the facility. ECR2 is a room temperature electron cyclotron resonance ion source, and the upgrade has strict requirements to retain radial access to the plasma chamber and keep the ion source operating without the use of superconducting magnets. The upgrade design with respect to the magnet arrangement and magnetization vectors has recently been presented [R. C. Vondrasek, J. McLain, and R. H. Scott, J. Phys.: Conf. Ser. 2743 , 012044 (2024)] using the same magnetic material as the current ECR2 hexapole. A thorough exploration of the demagnetization potential of this hexapole was carried out, and the risk of demagnetization was deemed too high, despite the magnetic performance meeting the requirements for the upgrade. Additional permanent magnet materials are considered with their respective performance evaluated. Magnet strength and demagnetization resistance are investigated and optimized with the final room temperature design demonstrating a high temperature transient demagnetization resistance and a radial magnetic field of 1.18 T at the plasma chamber wall. Finally, the simulations of this hexapole suggest that it will be sufficient to optimize intensity with a 14.5 GHz driving frequency and will allow 18 GHz operation, while keeping a high safety margin for maintaining magnet performance.

Argonne Tandem Linac Accelerator System↗

Embedding a Critical Point in a Hadron to Quark–Gluon Crossover Equation of State

It is shown how to embed a critical point in a smooth background equation of state so as to yield the critical exponents and critical amplitude ratios expected of a transition in the same universality class as the liquid–gas phase transition and the 3D Ising model. There are only two independent critical exponents; the relations α + 2β + $\gamma$ = 2 and β(δ - 1) = $\gamma$ arise automatically, as does a new relation between the two critical amplitudes. The resulting equation of state has parameters which may be inferred by hydrodynamic modeling of heavy-ion collisions in the Beam Energy Scan II at the Relativistic Heavy Ion Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗