Search NASA⌕ Search

SEARCH · Search NASA

Results for “helium irradiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The role of Cr concentration and temperature on cavity swelling with co-injected helium in dual-ion irradiated Fe and Fe-Cr alloys

The level of chromium plays an essential role in irradiation tolerance of Fe-Cr ferritic alloys. However, conflicting results have been reported regarding the dependence of cavity swelling under irradiation on Cr level and temperature. Here, we have performed a comprehensive set of simultaneous dual-ion (Ni + He) irradiations to high dose (~30 displacements per atom, dpa) at 400–550 °C on a series of ultra-high purity Fe and Fe-Cr binary alloys (3–14 wt.%Cr). Helium co-implantation rates of 0.1 and 10 appm He/dpa were selected to examine He synergistic effects relevant for fission and fusion reactor conditions, respectively. Cavities were observed in all irradiated samples by transmission electron microscopy. The results show that higher He implantation rate causes a shift in the swelling peak to higher temperatures in both Fe and Fe-Cr alloys. When assuming smaller cavities as biased sinks, the non-monotonic nature of the cavity swelling behavior is related to the ratio of biased to unbiased point defect sink strengths. Cr-enriched precipitates were observed in Fe-14Cr irradiated at 400 °C by atom probe tomography. Our analysis suggests the formation of Cr-enriched precipitates could suppress cavity swelling for Fe-Cr alloys with Cr content above 10 wt%.

36 MATERIALS SCIENCE↗

Disordering of helium gas bubble superlattices in molybdenum under ion irradiation and thermal annealing

Self-organization of gas bubbles causes the formation of an ordered array of nanoscale gas bubbles (a gas bubble superlattice), a highly efficient mechanism for gas storage under irradiation. Here, the stability of helium (He) gas bubble superlattices in molybdenum (Mo) under krypton (Kr) ion irradiation and thermal annealing has been investigated. The He gas bubble superlattices gradually become disordered under Kr ion irradiation at 300° C, and the order-disorder transformation process completes at 2.5 dpa. Both transmission electron microscopy (TEM) and synchrotron-based small-angle X-ray scattering (SAXS) reveal that the order-disorder transformation of He gas bubble superlattices is associated with a slight increase in the average bubble size. Phase-field modeling indicates that the inhomogeneous growth and coarsening of bubbles/voids cause the disordering of imperfect superlattices under irradiation and implies that highly ordered superlattices could potentially exhibit much stronger resistance to irradiation damage. Under thermal annealing, the He gas bubble superlattices in Mo become unstable and disordered at 1000° C with the bubble size increasing from ~1.1 to ~1.6 nm. The finding in this research provides insights into the disordering mechanisms of defect superlattices as well as guidance for designing stable defect superlattices in harsh environments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Revealing nano-scale lattice distortions in implanted material with 3D Bragg ptychography

Small ion-irradiation-induced defects can dramatically alter material properties and speed up degradation. Unfortunately, most of the defects irradiation creates are below the visibility limit of state-of-the-art microscopy. As such, our understanding of their impact is largely based on simulations with major unknowns. Here we present an x-ray crystalline microscopy approach, able to image with high sensitivity, nano-scale 3D resolution and extended field of view, the lattice strains and tilts in crystalline materials. Using this enhanced Bragg ptychography tool, we study the damage helium-ion-irradiation produces in tungsten, revealing a series of crystalline details in the 3D sample. Our results lead to the conclusions that few-atom-large ‘invisible’ defects are likely isotropic in orientation and homogeneously distributed. A partially defect-denuded region is observed close to a grain boundary. These findings open up exciting perspectives for the modelling of irradiation damage and the detailed analysis of crystalline properties in complex materials.

42 ENGINEERING↗

Flow Induced Vibration Studies in Pressurized Helium Gas Cooling Channels

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process. During irradiation, pressurized helium gas flows through 0.25 mm thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo-100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Longer duration testing will provide more data and verification for the findings presented in this report. The work will be continued in FY 24.

43 PARTICLE ACCELERATORS↗

Synthesis of magnesiowüstite nanocrystallites embedded in an amorphous silicate matrix via low energy multiple ion implantations

The synthesis process is presented for experimentally simulating modifications in cosmic dust grains using sequential ion implantations or irradiations followed by thermal annealing. Cosmic silicate dust analogues were prepared via implantation of 20–80 keV Fe - , Mg - , and O - ions into commercially available p-type silicon (100)wafers. The as-implanted analogues are amorphous with a Mg/(Fe+Mg) ratio of 0.5 tailored to match theoretical abundances in circumstellar dusts. Before the ion implantations were performed, Monte-Carlo-based ion-solid interaction codes were used to model the dynamic redistribution of the implanted atoms in the silicon substrate. 600 keV helium ion irradiation was performed on one of the samples before thermal annealing. Two samples were thermally annealed at a temperature appropriate for an M-class stellar wind, 1000 K, for 8.3 h in a vacuum chamber with a pressure of 1 x 10 -7 torr. The elemental depth profiles were extracted utilizing Rutherford Backscattering Spectrometry (RBS) in the samples before and after thermal annealing. X-ray diffraction (XRD)analysis was employed for the identification of various phases in crystalline minerals in the annealed analogues. Transmission electron microscopy (TEM) analysis was utilized to identify specific crystal structures. RBS analysis shows redistribution of the implanted Fe, Mg, and O after thermal annealing due to incorporation into the crystal structures for each sample type. XRD patterns along with TEM analysis showed nanocrystalline Mg and Fe oxides with possible incorporation of additional silicate minerals.

79 ASTRONOMY AND ASTROPHYSICS↗

Response of mouse epidermal cells to single doses of heavy-particles

The survival of mouse epidermal cells to heavy-particles has been studied In Vivo by the Withers clone technique. Experiments with accelerated helium, lithium and carbon ions were performed. The survival curve for the helium ion irradiations used a modified Bragg curve method with a maximum tissue penetration of 465 microns, and indicated that the dose needed to reduce the original cell number to 1 surviving cell/square centimeters was 1525 rads with a D sub o of 95 rads. The LET at the basal cell layer was 28.6 keV per micron. Preliminary experiments with lithium and carbon used treatment doses of 1250 rads with LET's at the surface of the skin of 56 and 193 keV per micron respectively. Penetration depths in skin were 350 and 530 microns for the carbon and lithium ions whose Bragg curves were unmodified. Results indicate a maximum RBE for skin of about 2 using the skin cloning technique. An attempt has been made to relate the epidermal cell survival curve to mortality of the whole animal for helium ions.

Leith, J. T.↗

Window Cooling Studies and Disk Vibration Testing on a Subset of Mo-100 Disks

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless-steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process, with a smaller percentage adding up to 2.2 kW of heat deposited on the Inconel window. During irradiation, pressurized helium gas flows through thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo 100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. LANL has previously also tested NMR’s Inconel beam window by heating the window, while flowing pressurized helium, using the average heat deposited on the window. However, the NMR beam is pulsed with a duty cycle of 12.5%, which introduces oscillation in temperature around the nominal 600 °C steady state value with each pulse. Available fatigue curves for Inconel are few, established for room temperature, and they are based on mechanical strain cycles not thermally induced strain as in the NMR target. The effect of pulsed beam heating on the Inconel window therefore needs to be quantified. This report details the experiments conducted to assess the factors that lead to mass loss in the NMR target disks as well as to understand the effect of a pulsed beam on NMR’s Inconel window. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 5 to 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Improved target holders significantly reduce disk mass loss to almost negligible quantities. This work finds that the larger window to first disk gap and improved target holder geometry should allow NMR to successfully conduct irradiations with minimal mass loss. The window tests were conducted to understand the effect of a pulsed beam on both the window longevity and to estimate the window temperature and displacement during pulsing. The experiments presented here were performed at significantly low power, due to the limitations of the induction heating system. The window temperature rose to approximately 73 °C with a significantly reduced power of 45 W without beam pulsing. With a 5 Hz pulse rate, 12.5% duty cycle, the window temperature remained constant at 26 °C. These experiments will be repeated with improved coil geometry and reported in upcoming journal papers.

42 ENGINEERING↗

Effects of surface vacancy-adatom pair formation on PFC tungsten surface morphological response

Abstract We report a simulation study of the effect of He-irradiation-induced surface vacancy-adatom pair formation on the surface morphological evolution of plasma-facing component (PFC) tungsten and examine a number of factors that impact such evolution. Our analysis is based on self-consistent dynamical simulations according to an atomistically-informed, continuum-scale surface evolution model that has been developed following a hierarchical multiscale modeling strategy and can access the spatiotemporal scales of relevance to fuzz formation. The model accounts for the flux of surface adatoms generated as a result of the surface vacancy-adatom pair formation effect upon He implantation, which contributes to the anisotropic growth of surface nanostructural features due to the different rates of adatom diffusion along and across step edges of islands on the tungsten surface. We have carried out atomic-scale computations of optimal diffusion pathways along and across island step edges on the W(110) surface and calculated Ehrlich–Schwoebel (ES) barriers in adatom diffusion along and across such step edges. This aspect of surface adatom diffusion contributes to anisotropic surface atomic fluxes, terrace and step diffusive currents, and has been incorporated into our PFC surface evolution model, which predicts the formation of preferentially aligned nanoridge stripe patterns on the PFC surface. We establish that these anisotropic diffusive currents accelerate nanotendril growth on the PFC surface and the onset of surface nanostructure pattern formation. We also explore systematically the dependence of the PFC surface morphological response on the surface temperature and He ion incident flux, characterize in detail the resulting surface topographies and growth kinetics, and compare the predicted surface morphologies with experimental observations. Our simulation predictions for the emerging surface nanostructure patterns under certain plasma exposure conditions are consistent with experimental findings in the literature.

36 MATERIALS SCIENCE↗

A quinary WTaCrVHf nanocrystalline refractory high-entropy alloy withholding extreme irradiation environments

In the quest of new materials that can withstand severe irradiation and mechanical extremes for advanced applications (e.g. fission & fusion reactors, space applications, etc.), design, prediction and control of advanced materials beyond current material designs become paramount. Here, through a combined experimental and simulation methodology, we design a nanocrystalline refractory high entropy alloy (RHEA) system. Compositions assessed under extreme environments and in situ electron-microscopy reveal both high thermal stability and radiation resistance. We observe grain refinement under heavy ion irradiation and resistance to dual-beam irradiation and helium implantation in the form of low defect generation and evolution, as well as no detectable grain growth. The experimental and modeling results—showing a good agreement—can be applied to design and rapidly assess other alloys subjected to extreme environmental conditions.

36 MATERIALS SCIENCE↗

Helium bubble size effects on the surface morphological response of plasma-facing tungsten

Abstract We report a simulation study on the effects of helium (He) bubble size on the morphological evolution and pattern formation on the surface of tungsten used as a plasma-facing component (PFC) in nuclear fusion devices. We have carried out a systematic investigation based on self-consistent dynamical simulations of surface morphological evolution according to an atomistically-informed, 3D continuum-scale model that captures well the relevant length and time scales of surface nanostructure formation in PFC tungsten. The model accounts for PFC surface diffusion, driven by the biaxial compressive stress originating from the over-pressurized He bubbles in the near-surface region of PFC tungsten as a result of He plasma exposure, combined with the formation of self-interstitial atoms in tungsten that diffuse toward the PFC surface and the flux of surface adatoms generated as a result of surface vacancy-adatom pair formation upon He implantation; this transport of surface adatoms contributes to the anisotropic growth of surface nanostructural features due to the different rates of adatom diffusion along and across step edges of islands on the tungsten surface. Our detailed analysis reveals that varying the average He bubble size plays an important role in the PFC surface growth kinetics as well as the resulting surface topography. Specifically, we find that an increase in the He bubble size leads to a deceleration in the growth rate of the tungsten nanotendrils that emanate from the PFC surface. We also find that the separation distance between the resulting surface features increases with increasing He bubble size, as well as over time. This coarsening effect is a thermally activated process resulting in an accurate description of the temperature dependence of the average surface feature separation by an Arrhenius relation.

36 MATERIALS SCIENCE↗

Cost-Effective Thermomechanical Processing of Nanostructured Ferritic Alloys: Microstructure and Mechanical Properties Investigation

Nanostructured ferritic alloys (NFAs), such as oxide-dispersion strengthened (ODS) alloys, play a vital role in advanced fission and fusion reactors, offering superior properties when incorporating nanoparticles under irradiation. Despite their importance, the high cost of mass-producing NFAs through mechanical milling presents a challenge. This study delves into the microstructure-mechanical property correlations of three NFAs produced using a novel, cost-effective approach combining severe plastic deformation (SPD) with the continuous thermomechanical processing (CTMP) method. Analysis using scanning electron microscopy (SEM)-electron backscatter diffraction (EBSD) revealed nano-grain structures and phases, while scanning transmission electron microscopy (STEM)-energy dispersive X-ray spectroscopy (EDS) quantified the size and density of Ti-N, Y-O, and Cr-O fine particles. Atom probe tomography (APT) further confirmed the absence of finer Y-O particles and characterized the chemical composition of the particles, suggesting possible nitride dispersion strengthening. Correlation of microstructure and mechanical testing results revealed that CTMP alloys, despite having lower nanoparticle densities, exhibit strength and ductility comparable to mechanically milled ODS alloys, likely due to their fine grain structure. However, higher nanoparticle densities may be necessary to prevent cavity swelling under high-temperature irradiation and helium gas production. Further enhancements in uniform nanoparticle distribution and increased sink strength are recommended to mitigate cavity swelling, advancing their suitability for nuclear applications.

36 MATERIALS SCIENCE↗

Spacelab 2 - Science in orbit

The success of Spacelab 2 is examined critically. Particular attention is given to the solar telescopes which were mounted on the instrument pointing system; these were designed to study solar irradiance, coronal helium, and exploding granules. Plasma experiments and the cosmic ray experiment (the 'Chicago Egg') are also described.

Page, T. L.↗

Radiation-Resistant Hybrid Lotus Effect for Achieving Photoelectrocatalytic Self-Cleaning Anticontamination Coatings

An experiment involving radiation-resistant hydrophobic coatings is planned for space exposure and experimental testing on the International Space Station (ISS) in 2011. The Lotus biocide coatings are designed for supporting space exploration missions. This innovation is an antibacterial, anti-contamination, and self-cleaning coating that uses nano-sized semiconductor semimetal oxides to neutralize biological pathogens and toxic chemicals, as well as to mitigate dust accumulation (see figure). The Lotus biocide coating is thin (approximately microns thick), lightweight, and the biocide properties will not degrade with time or exposure to biological or chemical agents. The biocide is stimulated chemically (stoichiometric reaction) through exposure to light (photocatalysis), or by an applied electric field (electrocatalysis). The hydrophobic coating samples underwent preliminary high-energy proton and alpha-ray (helium ion) irradiations at the Lawrence Berkeley National Laboratory 88" cyclotron and demonstrated excellent radiation resistance for a portion of the Galactic Cosmic Ray (GRC) and Solar Proton spectrum. The samples will undergo additional post-flight studies when returned to Earth to affirm further the radiation resistance properties of the space exposed coatings.

Taylor, Edward W.↗

Microstructure analysis of laser beam weldments performed on neutron-irradiated 304L steel containing 3 and 8 appm helium

We report that AISI 304 L austenitic stainless steel is one of the major structural materials used in light water reactors (LWRs). In the future, 304 L components may require repair, and several welding techniques have been proposed as candidates. In this study, laser beam welding using the low-energy contribution approach was performed in ~2016 on neutron-irradiated AISI 304 L steel with nominal values of 3 and 8 appm helium (He). The goal was to investigate the impact of helium on the irradiated material weldability and evaluate helium-associated damage. The weld and heat-affected zone (HAZ) microstructure was studied using scanning electron microscopy, electron backscatter diffraction, and transmission electron microscopy (TEM). Analysis of the weldment cross-sections did not reveal severe cracking. Still, evidence of incipient helium-associated damage was observed in the HAZ, manifesting as degraded grain boundaries (GBs) “decorated” by pore chains and mostly small (i.e., ≤ 25-30 µm) scattered cracks. The largest observed crack was ~50 µm in length. Helium-associated damage was localized within ~200-300 µm of the weld pool boundary, and the fraction of the compromised GBs, as a rule, was below ~9-11% of the total GB network. TEM analysis showed significant annealing of the radiation-induced defects at distances up to ~300 µm from the weld pool boundary. Inside the HAZ, the cavities (likely, helium bubbles) tended to form at GBs and inclusions, such as manganese sulfide precipitates in the grain interior. Crystallography analysis of the HAZ damage showed that random high-angle boundaries were most susceptible to helium-associated damage. In contrast, low-angle random boundaries and twin boundaries appeared to be strongly resistant to degradation from the combined effects of helium and welding.

36 MATERIALS SCIENCE↗

Comprehensive Characterization of Helium-Induced Degradation of the Friction Stir Weld on Neutron-Irradiated 304L Stainless Steel

The report describes new experimental results on the mechanical performance of the friction stir welds made on neutron-irradiated 304L stainless steel with helium. The report focuses on helium-related issues (e.g., the helium-induced degradation in the welded joint), aiming at the need to repair irradiated components of nuclear power plants. The friction stir welds analyzed here were previously produced at the US Department of Energy’s Oak Ridge National Laboratory, and initial characterization work was performed, mostly addressing the microstructure and if macroscopic cracks and helium bubbles present. The present work attempts to perform a more comprehensive study to assess mechanical performance (i.e., microhardness distribution, tensile properties, tensile deformation behaviors, and fractography analysis).

36 MATERIALS SCIENCE↗

In situ transmission electron microscopy with dual ion beam irradiation and implantation

To study the helium effects and their interactions with displacement damage in irradiated materials, an in situ dual-ion beam irradiation capability with transmission electron microscopy was recently established at the IVEM-Tandem Facility at Argonne National Laboratory. Pure nickel was irradiated in situ individually with 1 MeV Kr ions for displacement damage study, 16 keV He ions for helium implantation, and simultaneously with 1 MeV Kr ions and 16 keV He ions at the rate of 1 at.% He/dpa to study the interaction of helium and displacement damage at 500 degrees C. Helium bubbles were formed and segregated within dislocation loops during the He implantation experiment and no bubbles were observed outside the loops. The loop size increased with increasing helium concentration. In contrast, helium bubbles were formed uniformly in the matrix when nickel was irradiated simultaneously with 1 MeV Kr ions and 16 keV He ions. Overall, it is suggested that the uniformly-distributed defect clusters formed under 1 MeV Kr ion irradiation serve as trapping sites of helium atoms resulting in homogeneous nucleation of helium bubbles under the dualion beam irradiation in nickel.

36 MATERIALS SCIENCE↗

Helium effects and bubbles formation in irradiated Ti 3 SiC 2

Ti 3 SiC 2 is a potential structural material for nuclear reactor applications. However, He irradiation effects in this material are not well understood, especially at high temperatures. Here, we compare the effects of He irradiation in Ti 3 SiC 2 at room temperature (RT) and at 750 °C. Irradiation at 750 °C was found to lead to extremely elongated He bubbles that are concentrated in the nano-laminate layers of Ti 3 SiC 2 , whereas the overall crystal structure of the material remained intact. In contrast, at RT, the layered structure was significantly damaged and highly disordered after irradiation. Our study reveals that at elevated temperatures, the unique structure of Ti 3 SiC 2 can accommodate large amounts of He atoms in the nano-laminate layer, without compromising the structural stability of the material. The structure and the mechanical tests results show that the irradiation induced swelling and hardening at 750 °C are much smaller than those at RT. Overall, these results indicate that Ti 3 SiC 2 has an excellent resistance to accumulation of radiation-induced He impurities and that it has a considerable tolerance to irradiation-induced degradation of mechanical properties at high temperatures.

36 MATERIALS SCIENCE↗