Search NASA⌕ Search

SEARCH · Search NASA

Results for “hexapod”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Installation of the Dark Energy Spectroscopic Instrument at the Mayall 4-meter telescope

The Dark Energy Spectroscopic Instrument (DESI) is a Stage IV ground-based dark energy experiment that will measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 square degrees will be measured during the life of the experiment. We describe the installation of the major elements of the instrument at the Mayall 4m telescope, completed in late 2019. The previous prime focus corrector, spider vanes, and upper rings were removed from the Mayall’s Serrurier truss and replaced with the newlyconstructed DESI ring, vanes, cage, hexapod, and optical corrector. The new corrector was optically aligned with the primary mirror using a laser tracker system. The DESI focal plane system was integrated to the corrector, with each of its ten 500-fiber-positioner petal segments installed using custom installation hardware and the laser tracker. Ten DESI spectrographs with 30 cryostats were installed in a newly assembled clean room in the Large Coude Room. The ten cables carrying 5000 optical fibers from the positioners in the focal plane were routed down the telescope through cable wraps at the declination and hour angle axes, and their integral slitheads were integrated with the ten spectrographs. The fiber view camera assembly was installed to the Mayall’s primary mirror cell. Servers for the instrument control system replaced existing computer equipment. The fully integrated instrument has been commissioned and is ready to start its operations phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and evaluation of a prototype tracking system using the treatment couch

Purpose: Tumor motion increases safety margins around the clinical target volume and leads to an increased dose to the surrounding healthy tissue. The authors have developed and evaluated a one-dimensional treatment couch tracking system to counter steer respiratory tumor motion. Three different motion detection sensors with different lag times were evaluated. Methods: The couch tracking system consists of a motion detection sensor, which can be the topometrical system Topos (Cyber Technologies, Germany), the respiratory gating system RPM (Varian Medical Systems) or a laser triangulation system (Micro Epsilon), and the Protura treatment couch (Civco Medical Systems). The control of the treatment couch was implemented in the block diagram environment Simulink (MathWorks). To achieve real time performance, the Simulink models were executed on a real time engine, provided by Real-Time Windows Target (MathWorks). A proportional-integral control system was implemented. The lag time of the couch tracking system using the three different motion detection sensors was measured. The geometrical accuracy of the system was evaluated by measuring the mean absolute deviation from the reference (static position) during motion tracking. This deviation was compared to the mean absolute deviation without tracking and a reduction factor was defined. A hexapod system was moving according to seven respiration patterns previously acquired with the RPM system as well as according to a sin{sup 6} function with two different frequencies (0.33 and 0.17 Hz) and the treatment table compensated the motion. Results: A prototype system for treatment couch tracking of respiratory motion was developed. The laser based tracking system with a small lag time of 57 ms reduced the residual motion by a factor of 11.9 ± 5.5 (mean value ± standard deviation). An increase in delay time from 57 to 130 ms (RPM based system) resulted in a reduction by a factor of 4.7 ± 2.6. The Topos based tracking system with the largest lag time of 300 ms achieved a mean reduction by a factor of 3.4 ± 2.3. The increase in the penumbra of a profile (1 × 1 cm{sup 2}) for a motion of 6 mm was 1.4 mm. With tracking applied there was no increase in the penumbra. Conclusions: Couch tracking with the Protura treatment couch is achievable. To reliably track all possible respiration patterns without prediction filters a short lag time below 100 ms is needed. More scientific work is necessary to extend our prototype to tracking of internal motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Dark Energy Spectrographic Instrument (DESI) Guide-Focus Assembly

The specific research of the DESI project is to study in detail the expansion history of the Universe over the past 10 billion years. In order to do this, the project designed, fabricated, tested and commissioned the DESI instrument which has been deployed at the Mayall Telescope at the Kitt Peak National Observatory near Tucson, Arizona. The DESI project was conducted by approximately 30 US and foreign national laboratories. Our CRADA with the The Institut de Física d’Altes Energies (IFAE) in Barcelona (Spain) involved both research planning for eventual observing on the DESI telescope; and in providing hardware jointly designed by LBNL and IFAE; ten guide and focus sensor systems (GFAs) that either provide feedback to the Mayall telescope tracking system or provide focus position information to the DESI corrector hexapod. The key major goals of this CRADA were achieved.For survey planning, Drs. Fernandez, Fosalba, Garcia-Bellido, and Gaztañaga were all important contributors to the working groups to which they were assigned. Their application of redshift techniques, development of simulations to support target selection, exploration of the use of alternative observables to extract cosmological information like AP and void statistics, and the use of PAU data to assist in the optimization of targeting selections have been vital in the early planning for targets during commissioning. The major role in the project involved Drs. Castander, Miquel, Padilla, and Sànchez. They were all directly involved with the development of the Guide-Focus Assembly (GFA) hardware, software and filter validation. In order to accomplish the goals of the DESI Project, the Mayall telescope must track DESI targeted galaxies for up to 15 minutes and the DESI corrector must be repositioned on its hexapod system for different telescope orientations. The guide and focus assemblies (GFA) provide in this information. There are ten GFA modules on the focal plane, six providing tracking information and four providing focus information. A common GFA design supports both functions by a simple switching of its operating mode. IFAE designed, fabricated, tested and delivered twelve GFAs. Once received at LBNL, the GFAs were integrated with the focal plane. This was an iterative process as the GFA’s were delivered as they were made. Our working relationship with the IFAE scientists and engineers was remarkable given the distance and time zone issues. The GFAs have performed extremely well during the commissioning phase of the instrument.

79 ASTRONOMY AND ASTROPHYSICS↗

The application of linear actuators for telescope pointing control

A study team at MSFC has conceptually designed two lunar-based telescopes, a 16 m aperture Large Lunar Telescope (LLT) and a 4 m Cluster Telescope Experiment (CTE). The CTE serves as a technology tested for the LLT. The CTE utilizes a hexapod telescope mount to obtain a small gimbal angle that significantly extends the viewing space and observation time from that of a stationary transit telescope. This paper addresses the applicability of six linear actuators to provide limited gimbal rotation of the CTE telescope assembly. Kinematic constraint equations for the hexapod mount have been applied to a six degree-of-freedom rigid body model. Static equilibrium equations have been solved to address configuration design issues, and a feedback tracking control system has been designed and simulated.

Carrington, C. K.↗

The 4-meter lunar engineering telescope

The 16-meter diffraction limited lunar telescope incorporates a primary mirror with 312 one-meter segments; 3 nanometer active optics surface control with laser metrology and hexapod positioners; a space frame structure with one-millimeter stability; and a hexapod mount for pointing. The design data needed to limit risk in this development can be obtained by building a smaller engineering telescope on the moon with all of the features of the 16-meter design. This paper presents a 4.33-meter engineering telescope concept developed by the Summer 1990 Student Program of the NASA/JHU Space Grant Consortium Lunar Telescope Project. The primary mirror, made up of 18 one-meter hexagonal segments, is sized to provide interesting science as well as engineering data. The optics are configured as a Ritchey-Chretien with a coude relay to the focal plane beneath the surface. The optical path is continuously monitored with 3-nanometer precision interferometrically. An active optics processor and piezoelectric actuators operate to maintain the end-to-end optical configuration established by wave front sensing using a guide star. The mirror segments, consisting of a one-centimeter thick faceplate on 30-cm deep ribs, maintain the surface figure to a few nanometers under lunar gravity and thermal environment.

Peacock, Keith↗

Design of a support and foundation for a large lunar optical telescope

Design analysis and considerations are presented for the support structure and the foundation of the 16-m large lunar telescope (LTT). The proposed graphite/magnesium composite hexapod structure will support the 16-m mirror through a gimbal and trunnion assembly, with each hexapod leg consisting of seven 51-mm diameter 2-mm thick tubes bundled together. The foundation consists of three 152-cm diameter spud-can type footings. Results of the finite element analysis of the load-displacement characteristics of the support structure and the foundation are reported.

Chua, Koon M.↗

Arthropod phylogeny based on eight molecular loci and morphology

The interrelationships of major clades within the Arthropoda remain one of the most contentious issues in systematics, which has traditionally been the domain of morphologists. A growing body of DNA sequences and other types of molecular data has revitalized study of arthropod phylogeny and has inspired new considerations of character evolution. Novel hypotheses such as a crustacean-hexapod affinity were based on analyses of single or few genes and limited taxon sampling, but have received recent support from mitochondrial gene order, and eye and brain ultrastructure and neurogenesis. Here we assess relationships within Arthropoda based on a synthesis of all well sampled molecular loci together with a comprehensive data set of morphological, developmental, ultrastructural and gene-order characters. The molecular data include sequences of three nuclear ribosomal genes, three nuclear protein-coding genes, and two mitochondrial genes (one protein coding, one ribosomal). We devised new optimization procedures and constructed a parallel computer cluster with 256 central processing units to analyse molecular data on a scale not previously possible. The optimal 'total evidence' cladogram supports the crustacean-hexapod clade, recognizes pycnogonids as sister to other euarthropods, and indicates monophyly of Myriapoda and Mandibulata.

Non-NASA Center↗

Granular Media-Based Tunable Passive Vibration Suppressor

and vibration suppression device is composed of statically compressed chains of spherical particles. The device superimposes a combination of dissipative damping and dispersive effects. The dissipative damping resulting from the elastic wave attenuation properties of the bulk material selected for the granular media is independent of particle geometry and periodicity, and can be accordingly designed based on the dissipative (or viscoelastic) properties of the material. For instance, a viscoelastic polymer might be selected where broadband damping is desired. In contrast, the dispersive effects result from the periodic arrangement and geometry of particles composing a linear granular chain. A uniform (monatomic) chain of statically compressed spherical particles will have a low-pass filter effect, with a cutoff frequency tunable as a function of particle mass, elastic modulus, Poisson fs ratio, radius, and static compression. Elastic waves with frequency content above this cutoff frequency will exhibit an exponential decay in amplitude as a function of propagation distance. System design targeting a specific application is conducted using a combination of theoretical, computational, and experimental techniques to appropriately select the particle radii, material (and thus elastic modulus and Poisson fs ratio), and static compression to satisfy estimated requirements derived for shock and/or vibration protection needs under particular operational conditions. The selection of a chain of polymer spheres with an elastic modulus .3 provided the appropriate dispersive filtering effect for that exercise; however, different operational scenarios may require the use of other polymers, metals, ceramics, or a combination thereof, configured as an array of spherical particles. The device is a linear array of spherical particles compressed in a container with a mechanism for attachment to the shock and/or vibration source, and a mechanism for attachment to the article requiring isolation (Figure 1). This configuration is referred to as a single-axis vibration suppressor. This invention also includes further designs for the integration of the single-axis vibration suppressor into a six-degree-of-freedom hexapod "Stewart"mounting configuration (Figure 2). By integrating each singleaxis vibration suppressor into a hexapod formation, a payload will be protected in all six degrees of freedom from shock and/or vibration. Additionally, to further enable the application of this device to multiple operational scenarios, particularly in the case of high loads, the vibration suppressor devices can be used in parallel in any array configuration.

Dillon, Robert P.↗

Effects of Different Heave Motion Components on Pilot Pitch Control Behavior

The study described in this paper had two objectives. The first objective was to investigate if a different weighting of heave motion components decomposed at the center of gravity, allowing for a higher fidelity of individual components, would result in pilot manual pitch control behavior and performance closer to that observed with full aircraft motion. The second objective was to investigate if decomposing the heave components at the aircraft's instantaneous center of rotation rather than at the center of gravity could result in additional improvements in heave motion fidelity. Twenty-one general aviation pilots performed a pitch attitude control task in an experiment conducted on the Vertical Motion Simulator at NASA Ames under different hexapod motion conditions. The large motion capability of the Vertical Motion Simulator also allowed for a full aircraft motion condition, which served as a baseline. The controlled dynamics were of a transport category aircraft trimmed close to the stall point. When the ratio of center of gravity pitch heave to center of gravity heave increased in the hexapod motion conditions, pilot manual control behavior and performance became increasingly more similar to what is observed with full aircraft motion. Pilot visual and motion gains significantly increased, while the visual lead time constant decreased. The pilot visual and motion time delays remained approximately constant and decreased, respectively. The neuromuscular damping and frequency both decreased, with their values more similar to what is observed with real aircraft motion when there was an equal weighting of the heave of the center of gravity and heave due to rotations about the center of gravity. In terms of open- loop performance, the disturbance and target crossover frequency increased and decreased, respectively, and their corresponding phase margins remained constant and increased, respectively. The decomposition point of the heave components only had limited effects on pilot manual control behavior and performance.

manual control↗

Refinement of Objective Motion Cueing Criteria Investigation Based on Three Flight Tasks

The objective of this paper is to refine objective motion cueing criteria for commercial transport simulators based on pilots' performance in three flying tasks. Actuator hardware and software algorithms determine motion cues. Today, during a simulator qualification, engineers objectively evaluate only the hardware. Pilot inspectors subjectively assess the overall motion cueing system (i.e., hardware plus software); however, it is acknowledged that pinpointing any deficiencies that might arise to either hardware or software is challenging. ICAO 9625 has an Objective Motion Cueing Test (OMCT), which is now a required test in the FAA's part 60 regulations for new devices, evaluating the software and hardware together; however, it lacks accompanying fidelity criteria. Hosman has documented OMCT results for a statistical sample of eight simulators which is useful, but having validated criteria would be an improvement. In a previous experiment, we developed initial objective motion cueing criteria that this paper is trying to refine. Sinacori suggested simple criteria which are in reasonable agreement with much of the literature. These criteria often necessitate motion displacements greater than most training simulators can provide. While some of the previous work has used transport aircraft in their studies, the majority used fighter aircraft or helicopters. Those that used transport aircraft considered degraded flight characteristics. As a result, earlier criteria lean more towards being sufficient, rather than necessary, criteria for typical transport aircraft training applications. Considering the prevalence of 60-inch, six-legged hexapod training simulators, a relevant question is "what are the necessary criteria that can be used with the ICAO 9625 diagnostic?" This study adds to the literature as follows. First, it examines well-behaved transport aircraft characteristics, but in three challenging tasks. The tasks are equivalent to the ones used in our previous experiment, allowing us to directly compare the results and add to the previous data. Second, it uses the Vertical Motion Simulator (VMS), the world's largest vertical displacement simulator. This allows inclusion of relatively large motion conditions, much larger than a typical training simulator can provide. Six new motion configurations were used that explore the motion responses between the initial objective motion cueing boundaries found in a previous experiment and what current hexapod simulators typically provide. Finally, a sufficiently large pilot pool added statistical reliability to the results.

motion simulation↗

Alignment and Test of the Wide Field Infrared Survey Telescope (WFIRST) Engineering Design Unit (EDU) Grism

The WFIRST wide field instrument (WFI) includes a slitless spectrometer, which plays an important role in the WFIRST mission for the survey of emission-line galaxies. WFI is building engineering design and environmental test (EDU and ETU) units to reduce risk for the flight grism unit. We report here on successful build and test of the EDU grism. The four-element EDU grism consists of two prism elements and two diffractive elements that provide R700 dispersion. The elements were fabricated with alignment fiducials and integral flats to allow opto-mechanical alignment in six-degrees of freedom. Each element in turn, was installed onto a hexapod and positioned to its nominal orientation relative to the grism deck, then bonded into individual cells. Alignment measurements were performed in situ using theodolites to set tip/tilt and a Micro-vu non-contact Multisensor Measurement System was used to set despace, decenter and clocking of each element using the hexapod. After opto-mechanical alignment, the grism wavefront was measured using an Infrared ZYGO interferometer at various field points extending over a 20 by 14- degree (local) field of view. Using modeled alignment sensitivities, we determined the alignment correction required on our Element 2 prism compensator and successfully minimized the field dependent wavefront error and confocality. This paper details the alignment and testing of the EDU grism at ambient and cold operating temperatures.

Hagopian, John↗

Effects of Motion Fidelity on Pilot Performance Using Mixed-Reality Visuals

This paper investigates the effects of simulator motion fidelity on pilot performance using mixed-reality visuals. In NASA’s Vertical Motion Simulator, eleven pilots flew a lift-plus-cruise electric vertical takeoff and landing vehicle in a vertiport approach and landing task with four different motion conditions: no motion, small hexapod motion, large hexapod motion, and full motion. The simulator motion condition statistically significantly affected: 1) the severity of cybersickness, 2) motion ratings, 3) final approach and take-off boundary crossing groundspeed, 4) longitudinal touchdown point, and 5) battery time remaining after landing. The findings suggest that motion systems are essential in simulators with virtual- or mixed-reality visuals when it is required to have pilot flying performance similar to that in real flight.

mixed reality↗

Effects of Motion Fidelity on Pilot Performance Using Mixed-Reality Visuals

This paper investigates the effects of simulator motion fidelity on pilot performance using mixed-reality visuals. In NASA’s Vertical Motion Simulator, eleven pilots flew a lift-plus-cruise electric vertical takeoff and landing vehicle in a vertiport approach and landing task under four different motion conditions: no motion, small hexapod motion, large hexapod motion, and full motion. The simulator motion condition statistically significantly affected: 1) the severity of cybersickness, 2) motion ratings, 3) final approach and take-off boundary crossing groundspeeds, 4) longitudinal touchdown point, and 5) battery time remaining after landing. These results suggest that the use of motion systems in simulators with virtual- or mixed-reality visuals is warranted.

simulation↗

Momentum-resolved resonant inelastic soft X-ray scattering (qRIXS) endstation at the ALS

A momentum resolved resonant inelastic X-ray scattering (qRIXS) experimental station with continuously rotatable spectrometers and parallel detection is designed to operate at different beamlines at synchrotron and free electron laser (FEL) facilities. This endstation, currently located at the Advanced Light Source (ALS), has five emission ports on the experimental chamber for mounting the high-throughput modular soft X-ray spectrometers (MXS). Coupled to the rotation from the supporting hexapod, the scattered X-rays from 27.5° (forward scattering) to 152.5° (backward scattering) relative to the incident photon beam can be recorded, enabling the momentum-resolved RIXS spectroscopy. The components of this endstation are described in details, and the preliminary RIXS measurements on highly oriented pyrolytic graphite (HOPG) reveal the low energy vibronic excitations from the strong electron-phonon coupling at C K edge around σ* band. Lastly, the grating upgrade option to enhance the performance at low photon energies is presented and the potential of this spectroscopy is discussed in summary.

36 MATERIALS SCIENCE↗

Accuracy of Real-time Couch Tracking During 3-dimensional Conformal Radiation Therapy, Intensity Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy for Prostate Cancer

Purpose: To evaluate the accuracy of real-time couch tracking for prostate cancer. Methods and Materials: Intrafractional motion trajectories of 15 prostate cancer patients were the basis for this phantom study; prostate motion had been monitored with the Calypso System. An industrial robot moved a phantom along these trajectories, motion was detected via an infrared camera system, and the robotic HexaPOD couch was used for real-time counter-steering. Residual phantom motion during real-time tracking was measured with the infrared camera system. Film dosimetry was performed during delivery of 3-dimensional conformal radiation therapy (3D-CRT), step-and-shoot intensity modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT). Results: Motion of the prostate was largest in the anterior-posterior direction, with systematic ( N-Ary-Summation ) and random ({sigma}) errors of 2.3 mm and 2.9 mm, respectively; the prostate was outside a threshold of 5 mm (3D vector) for 25.0%{+-}19.8% of treatment time. Real-time tracking reduced prostate motion to N-Ary-Summation =0.01 mm and {sigma} = 0.55 mm in the anterior-posterior direction; the prostate remained within a 1-mm and 5-mm threshold for 93.9%{+-}4.6% and 99.7%{+-}0.4% of the time, respectively. Without real-time tracking, pass rates based on a {gamma} index of 2%/2 mm in film dosimetry ranged between 66% and 72% for 3D-CRT, IMRT, and VMAT, on average. Real-time tracking increased pass rates to minimum 98% on average for 3D-CRT, IMRT, and VMAT. Conclusions: Real-time couch tracking resulted in submillimeter accuracy for prostate cancer, which transferred into high dosimetric accuracy independently of whether 3D-CRT, IMRT, or VMAT was used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Versatile Multilayer Polarimeter for the Soft X-Ray Region

As modern undulators can generate light with arbitrary polarization states, experiments exploiting this feature in the range of soft x-rays have become increasingly widespread. For the success of these experiments characterising the polarization at the sample position is vital. Therefore a versatile, multi-purpose, UHV compatible, multilayer polarimeter has been designed and developed for measuring the Stokes vector of a soft x-ray beam. This high-precision, ultra high vacuum compatible instrument is supported by a Hexapod to simplify its alignment. Furthermore, the instrument has its own independent control system and has been designed for portability so that it can be moved with relative ease between different synchrotron facilities. The polarization analysis requires the rotation of a phase retarder and a polarization analyser, both about a common axis of the photon beam. The polarimeter employs reflection / transmission multilayers as phase retarders / analysers. Several sets of multilayers are installed inside the UHV chamber so that they may be exchanged in-situ without breaking the vacuum. The polarimeter doubles-up as a reflectometer / ellipsometer that enable determination of the polarization properties of optical elements including multilayers with very small surface roughness and several hundred bi-layers. The design details of the polarimeter and the results of first experiments to characterise the polarization of a beamline will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multilayer based soft-x-ray polarimeter at MAX IV Laboratory

A high precision five rotation-axes polarimeter using transmission multilayers as polarizers and reflection multilayers as analyzers has been designed and manufactured. To cover the extreme ultraviolet regime, Mo/Si, Cr/C, Sc/Cr, and W/B{sub 4}C multilayers for transmission and reflection have also been designed and produced. The polarimeter mechanics is supported on a hexapod to simplify the alignment relative to photon beam. The instrument is designed so that it can be easily transferred between different beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The chemoreceptor genes of the waterflea Daphnia pulex: many Grs but no Ors

Background: Chemoreception is vitally important for all animals, yet little is known about the genetics of chemoreception in aquatic organisms. The keystone species Daphnia pulex, a well known crustacean, is the first aquatic invertebrate to have its genome sequenced. This has allowed us the initial investigation of chemoreceptor genes in an aquatic invertebrate, and to begin the study of chemoreceptor evolution across the arthropod phylum. Results: We describe 58 Grs (gustatory receptors), belonging to the insect chemoreceptor superfamily, which were identified bioinformatically in the draft genome of the crustacean waterflea Daphnia pulex. No genes encoding proteins similar to the insect odorant receptors (Ors) were identified. These 58 Grs form 3 distinctive subfamilies of 37, 12, and 5 genes, as well as a highly divergent singleton (Gr58). In addition, Grs55–57 share distinctive amino acid motifs and cluster with the sugar receptors of insects, and may illuminate the origin of this distinctive subfamily. ESTs, tiling array, and PCR amplification results support 34 predicted gene models, and preliminary expression data comparing the sexes indicates potential female-biased expression for some genes. Conclusion: This repertoire of 58 chemoreceptors presumably mediates the many chemoperception abilities of waterfleas. While it is always possible that the entire Or gene lineage was lost at some point in the history of Daphnia pulex, we think it more likely that the insect Or lineage is indeed a relatively recently expanded gene lineage concomitant with the evolution of terrestriality in the insects or their hexapod ancestors.

59 BASIC BIOLOGICAL SCIENCES↗