Improving Cathode Testing with a High-Gradient Cryogenic Normal Conducting RF Photogun

Future electron accelerator applications such as X-ray free electron lasers and colliders are dependent on significantly increasing beam brightness. With the observation that linac beam manipulation’s best preservation of max brightness is at the cathode, we are incentivized to create an environment where we can study how to achieve the highest possible photogun brightness. In order to do so, we intend to extract beams from high-brightness photocathodes with the highest achievable accelerating gradients we can manage in a klystron-powered radiofrequency (RF) photogun. We utilize here cryogenic normal conducting cavities to achieve ultra-high gradients via limitation of breakdown rates (BDR). The low temperatures should also reduce cathode emittance by reducing the mean transverse energy (MTE) of electrons near the photoemission threshold. To this end, we have designed and produced a new CrYogenic Brightness-Optimized Radiofrequency Gun (CYBORG) for use in a new beamline at UCLA. We will introduce the enabling RF and photoemission physics as a primer for the new regime of high field low temperature cathodes we intend to enter. We further report the current status of the beamline commissioning, including the cooling of the photogun to 100 K, and producing 0.5 MW of RF feed power, which corresponds to cathode accelerating fields in the range of 80–90 MV/m. We further plan iterative improvements to both to 77 K and 1 MW corresponding to our ultimate goal >120 MV/m. Our discussion will include future beamline tests and the consideration of the initial realization of an ultra-high-gradient photoinjector concept.

Lawler, Gerard Emile (ORCID:0000000160113435)↗

Materials and technological processes for High-Gradient accelerating structures: new results from mechanical tests of an innovative braze-free cavity.

Pure oxygen-free high-conductivity copper is a widely used material for manufacturing accelerating cavities working at room temperature. Several studies attempted to explain limitations associated with the maximum allowed field gradients and the behaviour of vacuum RF breakdown in copper accelerating structures through generation and movement of dislocations under stresses associated with RF electric and magnetic fields. Pure copper and also copper alloys undergo mechanical and thermal treatments to be hardened and strengthened during manufacturing, although their mechanical properties significantly change after heating above 590°C. High temperature brazing and diffusion bonding are assembly methods widely used to manufacture ultra-high vacuum accelerating devices. However, these processes, occurring at about 800–1000°C, significantly affect the mechanical properties of copper and copper alloys. We introduce here a novel Tungsten Inert Gas welding procedure, which is fast and keeps the high-gradient surfaces of the cavity and other components well below the copper annealing temperature. This process may be successfully used to manufacture copper-based accelerating components. This technology further preserves the hardness and cleanliness of copper in order to achieve the maximum accelerating gradient.

47 OTHER INSTRUMENTATION↗

Mechanical properties of high gradient and hot isostatically pressed PWA 1480

This program has been designed to evaluate the potential benefits to alloy 1480 material properties due to high thermal gradient casting, hot isostatic pressing, and alternative heat treatment. Alloy 1480 castings have been obtained from vendors representing the extremes of commercial casting thermal gradients. Quantitative characterization of the dendrite arm spacing (DAS) and pore distributions has been conducted. A hot isostatic pressing (HIP) schedule, which avoids the many pitfalls of single crystal HIP has been devised for alloy 1480. In addition, an alternate heat treatment for alloy 1480 has been devised which provides benefits in mechanical properties. The standard gradient cast test material is being evaluated in the standard heat treat condition as a baseline and in the HIP plus alternate heat treated condition. The fhigh gradient cast material is being evaluated in alternate heat treat and HIP plus alternate heat treated conditions. Evaluations focus on demonstration of the benefits due to the applied processes, especially in the area of cyclic life.

Fritzemeier, L. G.↗

New accelerator capabilities with the high-gradient C-band [Slides]

LANSCE accelerator upgrades: Applications such as pRad desire higher proton beam energy. Material science at LANL will benefit from powerful directional high repetition rate X-ray sources. As it considers itself to be the NNSA accelerator laboratory, LANL should play role in developing compact accelerators for various national security missions.

43 PARTICLE ACCELERATORS↗

Temperature profiles in high gradient furnaces

Accurate temperature measurement of the furnace environment is very important in both the science and technology of crystal growth as well as many other materials processing operations. A high degree of both accuracy and precision is acutely needed in the directional solidification of compound semiconductors in which the temperature profiles control the freezing isotherm which, in turn, affects the composition of the growth with a concomitant feedback perturbation on the temperature profile. Directional solidification requires a furnace configuration that will transport heat through the sample being grown. A common growth procedure is the Bridgman Stockbarger technique which basically consists of a hot zone and a cold zone separated by an insulator. In a normal growth procedure the material, contained in an ampoule, is melted in the hot zone and is then moved relative to the furnace toward the cold zone and solidification occurs in the insulated region. Since the primary path of heat between the hot and cold zones is through the sample, both axial and radial temperature gradients exist in the region of the growth interface. There is a need to know the temperature profile of the growth furnace with the crystal that is to be grown as the thermal load. However it is usually not feasible to insert thermocouples inside an ampoule and thermocouples attached to the outside wall of the ampoule have both a thermal and a mechanical contact problem as well as a view angle problem. The objective is to present a technique of calibrating a furnace with a thermal load that closely matches the sample to be grown and to describe procedures that circumvent both the thermal and mechanical contact problems.

Fripp, A. L.↗

The Role of Oxygen Concentration in Enabling High Gradients in Niobium SRF Cavities

We studied the role of O concentration with depth in the performance of Nb SRF cavities. An ensemble of electropolished 1.3 GHz cavities, which initially showed high field Q-slope (HFQS), was subjected to sequential testing and treatment with in-situ low temperature baking at various temperatures. We find that increasing the bake duration causes (i) an increase in the onset of HFQS until it is absent up to quench (ii) a non-monotonic relationship with the quench field (iii) an evolution of the RBCS toward a non-equilibrium behavior that drives anti-Q slope. Our data is qualitatively explained by assuming an O diffusion model and suggests that the mitigation of HFQS that arises from 120 C in-situ LTB is mediated by the diffusion of O from the native oxide which prevents the precipitation of proximity-coupled Nb nano-hydrides, in turn enabling higher quench fields. The decrease in quench field for cavities in which O has been diffused >90 nm from the RF surface may be due to a reduction of the field limit in the SS bilayer structure. We also suggest that the evolution of the RBCS occurs due to the absence of proximity coupled inclusions, bringing about non-equilibrium effects.

Bafia, D.↗

High gradient research and facilities at Los Alamos National Laboratory [Slides]

A particle accelerator is a scientific instrument that produces a directional stream of electrically charged particles, usually electrons or protons. The accelerator propels particles to high speeds, close to the speed of light. Historically, accelerators play a crucial role in scientific discovery. Nowadays, accelerators produce particle beams for biomedical and material research, manufacturing, energy technology, and Homeland security.

43 PARTICLE ACCELERATORS↗

TESLA's High Gradient March: Thirty years anniversary of TESLA Technology Collaboration (TTC)

In 2020, the TTC (TESLA Technology Collaboration) celebrates 30 years of collaborative efforts on SRF technologies. The first international TESLA workshop on a TeV Energy Superconducting Linear Accelerator was held at Cornell University on July 23-26, 1990. The purpose of the meeting was to work on a parameter list for a superconducting high energy physics collider in the Teravolt energy region and to explore ideas on how to increase the gradients and lower the costs for the accelerator structures. It was clear from the beginning that the needed technological progress would require a large international collaboration. This meeting was indeed the origin of a long preparation effort toward a future ILC (International Linear Collider), which eventually led to the realization of the TTF (TESLA Test Facility, since 2005 operated as the DESY user facility FLASH) and the European XFEL also at DESY, and created the conditions supporting the proposals for several large SRF-based research facilities like SNS, LCLS-II, ESS, PIP-II and SHINE, as well as a growing number of smaller facilities around the world. Highlights of this 30-year international collaboration are presented and celebrated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-Gradient Wien Spin Rotators at Jefferson Lab

Nuclear physics experiments performed in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory (JLab) require spin manipulation of electron beams. Two Wien spin rotators in the injector keV region are essential at CEBAF to establish longitudinal polarization at the end station target, and to flip the polarization direction by ? rad to rule out false asymmetries. In a Wien filter, the homogeneous and independent electric and magnetic fields, along with the velocity vectors of the electrons that traverse it, form a mutually orthogonal system. The magnitude of the electrostatic field, established by biasing two highly-polished electrodes, defines the desired spin angle at the target yet deviates the beam trajectory due to the Lorentz force. The beam trajectory in the Wien is then re-established by adjusting the magnetic field, induced by an electromagnet encasing the device vacuum chamber. This contribution describes the evolution design and high voltage testing of Wien filters for spin manipulation at increased beam energies in the keV injector region, required by high precision parity violation experiments like MOLLER.

Palacios Serrano, G. G.↗

High-Gradient Wien Spin Rotators at Jefferson Lab

Nuclear physics experiments performed in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory (JLab) require spin manipulation of electron beams. Two Wien spin rotators in the injector keV region are essential at CEBAF to establish longitudinal polarization at the end station target, and to flip the polarization direction by ? rad to rule out false asymmetries. In a Wien filter, the homogeneous and independent electric and magnetic fields, along with the velocity vectors of the electrons that traverse it, form a mutually orthogonal system. The magnitude of the electrostatic field, established by biasing two highly-polished electrodes, defines the desired spin angle at the target yet deviates the beam trajectory due to the Lorentz force. The beam trajectory in the Wien is then re-established by adjusting the magnetic field, induced by an electromagnet encasing the device vacuum chamber. This contribution describes the evolution design and high voltage testing of Wien filters for spin manipulation at increased beam energies in the keV injector region, required by high precision parity violation experiments like MOLLER.

Palacios Serrano, G. G.↗

High gradient C-band research at Los Alamos [Slides]

The Los Alamos C-band Test stand (CERF-NM) is operational. We are about to start testing and fabricating cavities using various materials and various fabrication methods for both ours and collaborators’ cavities.