133Xe Noble Gas Mass Spectrometry Measurement for High Purity Germanium Detector Performance Verification

Idaho National Laboratory produces quality control standards for laboratories that operate xenon radionuclide monitoring systems. Activities reported with each quality control standard are quantified using high purity germanium detectors. A collection of measurement capabilities are being set up at Idaho National Laboratory to establish an in-house high purity germanium detector performance verification system, with noble gas mass spectrometry being one of these measurement capabilities. The first noble gas mass spectrometry and high purity germanium measurement comparison is presented here. A Xe-133 gas sample was prepared and the activity was quantified with high purity germanium detectors. The Xe-133 sample was diluted with a known quantity of isotopically enriched Xe-126 gas; the resulting Xe-133 : Xe-126 atom ratio was calculated to be 1.15x10-4 +/- 2% at reference time t. An aliquot of this gas sample containing approximately 10 million Xe-133 atoms was introduced into a ThermoFisher Scientific Helix MC Plus noble gas mass spectrometer for analysis. The measured Xe-133 : Xe-126 atom ratio was determined to be 1.10x10-4 +/- 2% (1-sigma uncertainty) at reference time t, about 4.3% lower than the atom ratio determined with the measured high purity germanium activity.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Gamma Spectroscopy

Gamma Spectroscopy, or the identification of radio-isotopes based on energy, is extraordinarily useful in the Nuclear field. High Purity German (HPGe) gamma detectors along with Sodium Iodine (NaI) gamma detectors are commonly used to identify possible contamination and determine enrichments, among many other applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of FRAM Measurements to Establish Methodology Uncertainty

Qualification measurements were performed at Oak Ridge National Laboratory (ORNL) on a variety of measurement standards. These measurements will be used to qualify the Fixed-Energy, Response Function Analysis with Multiple Efficiency (FRAM) code with a high purity germanium (HPGe) detector for use at ORNL. Measured items include uranium isotopic standards, U 3 O 8 line sources, and a uranium tetrafluoride source. The 235 U enrichment was estimated using the FRAM isotopic analysis software for each source and compared with the declared isotopic values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of ISOCS Measurements to Establish Methodology Uncertainty

Qualification measurements were performed at the US Department of Energy’s (DOE’s) Oak Ridge National Laboratory (ORNL) on a variety of measurement standards. These measurements will be used to qualify the In-Situ Object Counting System (ISOCS) measurement method with a high-purity germanium (HPGe) detector for use at ORNL. Measured items include uranium isotopic standards, filter papers coated with uranium oxide (U 3 O 8 ), U 3 O 8 line sources, and a uranium tetrafluoride (UF 4 ) source. The 235 U mass was estimated using the ISOCS calibration software for each source and compared with the declared isotope mass value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Problems with Re-Os isochron determinations

We have developed closed-system techniques for the equilibration of Os isotopes and for the calibration of Re and Os tracers using high-purity metals. The results show reproducibility of +/- 0.5% for calibrations of Os using different chunks of the same high-purity Os metal produced by vacuum arc melting. On a Re-Os evolution diagram the analyses of Negrillos and of Tocopilla are displaced along horizontal lines and are not consistent with a well-defined isochron. We conclude that is unclear whether whole-rock samples of irons of individual classes of iron meteorites (including the IIA class) define isochrons.In light of these observations, one must consider the evidence for phases in which Re and Os may become redistributed. We note that the IIA irons are composed of large or single kamacite crystals and do not contain taenite. This may hinder redistribution of Re and Os and may allow the IIA irons to define isochrons in preference to other magmatic iron classes. However, the IIA irons also include ubiquitous rhabdites, up to 20 mm in length, and troilite-daubreelite nodules. It has been observed that rhabdites are extremely rich in Pt-group elements. In addition to these considerations, Negrillos and Tocopilla were found in nitrate deposits and show evidence of corrosion. Therefore, it is possible that different samples of these meteorites have been differentially weathered, although our samples appeared fresh. We conclude that it is important to identify the phases in which Re and the PGEs are located and to address in detail the evidence for Re and Os remobilization.

Papanastassiou, D. A.↗

A new highly enriched 233 U reference material for improved simultaneous determination of uranium amount and isotope amount ratios in trace level samples

A highly-enriched 233 U reference material (>0.99987 n( 233 U)/n(U)) has been prepared and characterized for use as an isotope dilution mass spectrometry spike. An ion exchange separation was performed on 1 g of high purity 233 U to further reduce trace amounts of contaminant Pu in the material. The purified 233 U was then prepared as a master solution which was analyzed for molality of uranium by modified Davies and Gray titration. A portion of the master solution was quantitatively diluted and dispensed for reference material units. Selected units were analyzed for verification of uranium amount and to characterize uranium isotope amount ratios by multi-collector inductively couple plasma mass spectrometry. Furthermore, modelling of spike-corrected isotopic data show that the new spike will enable simultaneous measurements of uranium amount and isotope amount ratios with resulting uncertainties that are substantially less sensitive to over spiking than widely used 233 U certified reference materials.

233U↗

Short-lived photofission product yields from 238 U and 232 Th at Bremsstrahlung X-ray endpoint energies of 8, 14, and 20 MeV for nuclear forensics isotope production applications

The existing photofission product yield data sets are often based on nuclear models, and limited experimental measurements of these fission product yields have been performed. These experiments resulted in measured cumulative fission product yields (CFPYs) for 238 U and 232 Th for the bremsstrahlung X-ray endpoint energies of 8, 14, and 20 MeV. The half-lives of the reported fission products range from 1.07–40.8 s. This work is motivated by a demonstrated need for novel isotope production methods for nuclear forensics and improved nuclear data to support the nonproliferation community. A high-purity germanium detector and a pneumatic transfer system were employed for measurements of short-lived fission products, collecting data between cycles of accelerator irradiation and measurement.

07 ISOTOPE AND RADIATION SOURCES↗

Absolute mass calibration of fission product distributions measured with the E-$v$ method

The mass calibration of fission product distributions measured with the energy–velocity (E-v) method constitutes a technical challenge. The energy loss of the fission fragments in the various dead layers of the spectrometer and other sources of pulse-height defects of the energy detectors are a significant source of systematic uncertainty in the mass calculations used to determine the measured fission product yields. Here, in this study, the absolute calibration of the fission mass distributions is accomplished by measuring prompt γ-rays in coincidence with the fission fragments. This allows for the direct calibration of the mass spectra and eliminates any dependence on potentially complicated energy corrections. The first test measurement was performed at the Los Alamos Neutron Science Center employing the SPectrometer for Ion DEtermination in fission Research (SPIDER). SPIDER is a 2E-2v spectrometer designed for measuring independent fission product yields from neutron-induced fission. In this test, the single-arm SPIDER (E-v) system and an array of 252 Cf sources were used. The single-arm system consisted of two time pick-off detectors for measuring the time-of-flight of the fission fragments and a double-sided silicon strip detector (DSSD) for measuring the kinetic energy. Characteristic γ-rays from fission fragments were detected using three high-purity germanium (HPGe) detectors. For the mass calibration, γ–mass coincidence events from twelve product isotopes were used. The measured FPYs from 252 Cf spontaneous fission were found to be in excellent agreement with the evaluated data after applying the absolute mass calibration. From the γ–mass coincidence events, the mass resolution of the system was also extracted. An average mass resolution of ~1.4 AMU (FWHM) for the light fragments and ~2.4 AMU (FWHM) for the heavy fragments were found. This was the first in-situ calibration and characterization of the SPIDER spectrometer, which paves the way for high-quality FPY measurements with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simple separation of technetium from molybdenum for tracer isotope production

A procedure for the separation of technetium isotopes from bulk molybdenum was developed in nitric acid media. After irradiation of nat Mo foils, and dissolution in H 2 O 2 , the solution is acidified to 2 M HNO 3 , and anion exchange resin is used to separate technetium from molybdenum. The procedure is simple, requiring only basic laboratory equipment and, with a two-column separation, the technetium yield is high (~ 85%) with extremely high purity (< 0.1 ppm nat Mo). In conclusion, this is ideally suited for laboratory production of technetium tracer isotopes, particularly 95m Tc.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Improvements to the 115g/115m Cd Nuclear Data

Repeated measurements of the isotope 115m Cd by Los Alamos National Laboratory (LANL), Pacific Northwest National Laboratory (PNNL), and Atomic Weapons Establishment (AWE) have revealed a consistent discrepancy between beta and gamma counting. This suggests that a significant disparity exists between the true value of the isotope’s gamma-ray branching ratios and the values reported by the National Nuclear Data Center (NNDC). Enriched 114 Cd was irradiated using thermal neutrons to produce a high-purity 115m/g Cd source for counting and analysis using traditional singles gamma-ray spectroscopy, liquid scintillation counting, gas-proportional counting, and analysis using the new Gamma-Alpha-Beta-Gamma (GABγ) and Gamma-Alpha-Beta Radio-Isotope EvaLuator (GABRIEL) coincidence detection systems. Using the D-T fusion generated neutrons, reduces the wait time required to let the short-lived 115Cd ground state decay away by leveraging the 1:1 production ratio of the ground and metastable state of 115 Cd from the 115 In (n,p) reaction relative to the 10:1 production ratio of the ground and metastable isotopes of 115 Cd by thermal neutron capture on 114 Cd. However, the much higher flux in from the Washington State University TRIGA reactor is a more rapid method of production of 115m/gCd but requires access to enriched 114 Cd. High purity 115m/g Cd samples were analyzed on regular intervals over a period of 140-days. The activity of 115m Cd measured by beta and gamma show a clear discrepancy using the current best known gamma-ray decay branching ratios. Based on these observations and measurements, a set of new branching ratio recommendations have been produced using conventional counting techniques and the advanced GAB? and GABRIEL instruments.

07 ISOTOPE AND RADIATION SOURCES↗

Monitoring Methods for Early Detection of Inadvertent Fission Product Release at the Advanced Test Reactor

Isotope effluent data obtained during three instances of experiment failures at the Advanced Test Reactor (ATR) are analyzed to provide an overview of the methods used to detect initial signs of unintended fission product release. The data is contextualized with the operational experience, including means of identification and subsequent mitigation strategies, gained during these events. General trends as well as variations in isotopic behavior between the three failures are explored. Background on the Real Time Monitor, a High Purity Germanium detector, and other fission product monitoring systems utilized at the Advanced Test Reactor is also provided. The presented analysis was used to establish administrative action levels which are currently utilized by ATR for early detection of experiment fission product release. Early identification provides time to make programmatic decisions before approaching safety and environmental limits.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Stellar s-process neutron capture cross sections on 78,80,84,86 Kr determined via activation, atom trap trace analysis and decay counting

We present a detailed account of neutron capture experiments of astrophysical relevance on 78,80,84,86 Kr (n, γ) reactions at the border between weak and main s process. The experiments were performed with quasi-Maxwellian neutrons from the Liquid-Lithium Target (LiLiT) and the mA-proton beam at 1.93 MeV (2-3 kW) of the Soreq Applied Research Accelerator Facility (SARAF). The setup yields high-intensity approximate to 40 keV quasi-Maxwellian neutrons (3-5 x10 10 n/s) closely reproducing the conditions of s-process stellar nucleosynthesis. A sample of 100 mg of atmospheric, pre-nuclear-age Kr gas contained in a Ti spherical shell was activated in the LiLiT neutron field. The abundances of long-lived Kr isotopes ( 81,85g Kr) were measured by atom counting via atom trap trace analysis (ATTA) at Argonne National Laboratory and low-level counting (LLC) at University of Bern. This work is the first measurement of a nuclear cross section using atom counting via ATTA. The activities of short-lived Kr isotopes ( 79,85m,87 Kr) were measured by gamma-decay counting with a high-purity germanium detector. Maxwellian-averaged cross sections for s-process thermal energies are extracted. By comparison to reference values, our nucleosynthesis network calculations show that the experimental cross sections have a strong impact on calculated abundances of krypton and neighboring nuclides, in some cases improving agreement between theory and observations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of gas purity on backgrounds of collision reaction cell-equipped MC-ICP-MS

The advent of multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) instruments equipped with collision reaction cells (CRCs) facilitates interference removal/mitigation via online gas phase separations. This approach has proven effective for high intensity ion beams measured on Faraday collectors; however, it has been observed that introduction of gas in the CRC can result in significant background signals relative to the more sensitive ion counters. These backgrounds hinder use of these instruments for low level concentration and isotopic ratio measurements when employing a reaction gas. Here, this work directly evaluates the effect of gas purity on backgrounds of CRC-MC-ICP-MS instruments. Introducing high-purity research grade O 2 (99.999%) into the CRC produces complex background spectra with intensities >10 4 cps observed at most masses across the measured mass range (7-300 m / z ). Some features of the observed spectra (i.e., positive mass defects) can be attributed to molecular compounds comprised of significant hydrogen. Additionally, some specific molecular species can be identified (i.e., MoO x H y + ) and appear to be derived from molybdenum rods comprising the CRC. Further purifying the gas reduces the intensity of these backgrounds by several orders of magnitude, to <10 2 cps in many cases, and reduces complexity of the resulting spectra. This reduction in background appears to be in part driven by removal of impurities (i.e., H 2 O) from the gas. This work demonstrates that additional purification of reaction gases prior to introduction into the CRC significantly reduces backgrounds detected, potentially expanding the utility of CRC-MC-ICP-MS for making low level measurements using inline gas phase ion separations.

Schlieder, Tyler D. [Pacific Northwest National La↗

New approach to precisely measure γ-ray intensities for long-lived fission products, with results for the decay of 95 Zr

For many fission products, the rays emitted following decay provide an easily-detectable signature that can be used to identify their quantities and distributions in a sample. As a result, γ-ray spectroscopy is often exploited to study fission-product yields, provided sufficiently accurate information on the γ-ray intensity is available. However, in many cases, the uncertainties in the existing nuclear data are large enough that they compromise the precision achievable for modern experiments and applications. To address this need, we have developed a new experimental method that is well suited to precisely measure absolute γ-ray intensities in the β decay of long-lived fission products. The approach involves the production of a radiopure sample by implantation of a mass-separated ion beam from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) facility on a thin carbon foil. The emitted β-decay radiation is detected with a 4π gas proportional counter and a meticulously efficiency-calibrated high-purity germanium (HPGe) detector. As a first measurement to demonstrate the approach, we studied the absolute γ-ray intensities of the strongest transitions following the β decay of 95 Zr and its decay-daughter 95 Nb, and determined them to fractional precisions of better than 1–2%. In addition, with a larger sample of activity produced through neutron irradiation of an isotopically-enriched Zr foil, we performed a high-precision measurement of the relative γ-ray intensities following the decay of 95 Zr with just the HPGe detector. Here, the sample-production method at CARIBU and the coincidence detection approach demonstrated here can be applied to study fission products with half-lives longer than a day, which includes isotopes important not only for nuclear-energy and national-security applications, but also for medical-isotope research and environmental monitoring.

4π↗

Hydrogen transport in iron and steel

The permeabilities of protium, deuterium, and tritium in foil specimens of Marz grade iron, 4130 steel, Armco iron, HP-9-4-20, and T-1 steels were studied at hydrogen pressures between 0.02 and 0.5 MPa over the temperature range 260-700 K. The permeability was measured by a pressure-rise method, deuterium counting with a detector, and radioactivity counting. Good agreement is found between the measurement techniques used. It is shown that the permeabilities of protium, deuterium, and tritium in iron and T-1 steel at temperatures as low as 260 K are in good agreement with the equation proposed by Gonzalez (1967). However, the permeabilities of HP-9-4-20 and 4130 steel to hydrogen are typically lower than predicted. The isotope effect on hydrogen permeability of HP-9-4-20, 4130 and T-1 steels, and high-purity iron can be estimated by an inverse square root of mass correction.

Louthan, M. R., Jr.↗

Interstellar-gas experiment (A0038)

The objectives of this experiment are to collect and isotopically analyze interstellar gas atoms around the orbit of the Earth for the purpose of obtaining new data relevant to understanding nucleosynthesis, and to study the dynamics of the interstellar wind inside the heliosphere and the isotopic composition of the interstellar medium outside the heliosphere. The experiment hardware will act as a set of simple cameras with high-purity copper-beryllium collecting foils serving as the film. The experiment housing will mount and thermally control the foils, establish the viewing angles and viewing direction, provide baffling to reject ambient neutral particles, provide a voltage grid to reject ionospheric charged particles, sequence collecting foils, control exposure times, and protect the foils from contamination during the deployment and retrieval of the LDEF. After being returned to Earth, the entrapped atoms can be analyzed by mass spectroscopy to determine the relative abundance of the different isotopes of helium and neon. An attempt will also be made to detect argon.

Lind, D. L.↗

Precise half-life determination of 131 Ba and 125 Xe

Barium-131 and Xenon-125 are valuable radioisotopes with numerous scientific and medical applications. Here, we produced both isotopes via proton irradiation of a cesium iodide (CsI) target at the Brookhaven Tandem Van de Graaff accelerator (BTVG). Following irradiation, we conducted systematic γ-ray spectroscopy measurements at the National Nuclear Data Center (NNDC) decay station using a calibrated High-Purity Germanium (HPGe) detector, collecting data over a 2-month period (spanning approximately 4.5 half-lives for 131 Ba). Through careful analysis of the characteristic γ-ray emissions from both isotopes, we determined the half-life of 131 Ba to be 11.55(6) days, which agrees with the previously evaluated value. For 125 Xe, we measured a half-life of 16.56(8) hours, slightly lower than the evaluated value.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Genesis Mission Solar Wind Collection: Solar-Wind Statistics over the Period of Collection

The NASA Genesis spacecraft was launched August 8, 2001 on a mission to collect samples of solar wind for 2 years and return them to earth September 8, 2004. Detailed analyses of the solar wind ions implanted into high-purity collection substrates will be carried out using various mass spectrometry techniques. These analyses are expected to determine key isotopic ratios and elemental abundances in the solar wind, and by extension, in the solar photosphere. Further, the photospheric composition is thought to be representative of the solar nebula with a few exceptions, so that the Genesis mission will provide a baseline for the average solar nebula composition with which to compare present-day compositions of planets, meteorites, and asteroids. The collection of solar wind samples is almost complete. Collection began for most substrates in early December, 2001, and is scheduled to be complete on April 2 of this year. It is critical to understand the solar-wind conditions during the collection phase of the mission. For this reason, plasma ion and electron spectrometers are continuously monitoring the solar wind proton density, velocity, temperature, the alpha/proton ratio, and angular distribution of suprathermal electrons. Here we report on the solar-wind conditions as observed by these in-situ instruments during the first half of the collection phase of the mission, from December, 2001 to present.