Search NASA⌕ Search

SEARCH · Search NASA

Results for “high resolution x-ray spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Quantifying the Impact of Metal Population Distribution in MFI-Supported Mo Catalysts for Methane Dehydroaromatization

Precise evaluation of intrinsic kinetic behavior in Mo/MFI catalysts for methane dehydroaromatization (MDA) is confounded by variations in Mo dispersion and speciation, which are influenced by metal loading and zeolite acidity. This work advances the utility of H 2 -temperature programmed reduction (H 2 -TPR) for characterizing Mo/MFI catalysts by enabling quantitative comparison of MoO x populations distinguished by reduction behavior and linked to initial catalytic performance. A comprehensive H 2 reduction pathway is established through systematic H 2 - TPR studies varying catalyst composition (1–10 wt % Mo, Si/Al = 15, 40, ∞), supplemented by UV-Raman spectroscopy, X-ray powder diffraction, N 2 physisorption, NH 3 -TPD, and advanced spectroscopic analysis (in situ XAS with principal component analysis/multivariate curve resolution—alternating least squares). Two low-temperature H 2 -TPR regions capture distinct Mo populations undergoing initial Mo(VI)→Mo(IV) reduction: a lower-temperature population (Mo-RI) associated primarily with highly dispersed, anchored MoO x species expected to predominantly reside within MFI channels, and a higher-temperature population (Mo-RII) corresponding to a broader set of MoO x species that becomes increasingly bulk-like/extrazeolitic at higher Mo loading. Quantification of these populations provides practical, kinetically relevant descriptors for comparing initial MDA rates across catalysts with varying Mo loading, Si/Al ratio, and MoO x heterogeneity. Application of lower-temperature Mo-RI estimates to kinetic measurements reveals a minimum threshold of ∼0.12 × 10 –3 mol Mo-RI/g cat , above which initial forward benzene rates normalized to this population converge despite differences in metal loading and zeolite Brønsted acidity. This threshold coincides with a transition toward a common C 2 -mediated benzene-forming regime, as indicated by approach-to-equilibrium analysis of methane-to-ethane, ethane-to-ethylene, and ethylene-to-benzene reaction steps. Above this threshold, normalized initial benzene rates are nearly invariant with increasing Mo-RII/Mo-RI population ratio, indicating that excess Mo-RII populations, including bulk-like/extrazeolitic MoO x domains present at higher loading, do not measurably suppress benzene formation associated with anchored and mostly channel-confined Mo population under the initial-rate conditions examined.

Mo/MFI↗

Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission

We present an overview of the design and in-flight performance of the Resolve soft X-ray spectrometer on the X-Ray Imaging and Spectroscopy Mission that was successfully launched on September 7, 2023, on a JAXA H-IIA rocket from the Tanegashima Space Center of Japan. The instrument has a 36-pixel array of microcalorimeters, 35 of which are at the focus of a high-throughput grazing-incidence X-ray mirror. The instrument has achieved its required operational base temperature of 0.05 K and a spectral resolution of 4.5 eV (FWHM) at 6 keV. The cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate with and without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications are that the cryogen lifetime may reach 6 years with a cryogen-free mode thereafter. A series of onboard X-ray calibration sources produces energy scale calibration lines simultaneously while observing celestial sources. The overall design and in-flight performance of Resolve are described.

Astronomy and AstroPhysics↗

Resolve instrument onboard XRISM: design, integration, and instrument test results

The Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM) consists of an array of 6 × 6 silicon-thermistor microcalorimeters cooled down to 50 mK and a high-throughput X-ray mirror assembly (XMA) with a focal length of 5.6 m. XRISM is a recovery mission of ASTRO-H/Hitomi, and the Resolve instrument is a rebuild of the ASTRO-H Soft X-ray spectrometer (SXS) and the Soft X-ray Telescope (SXT) that achieved energy resolution of ∼ 5 eV FWHM on orbit, with several important changes based on lessons learned from ASTRO-H. The flight models of the Dewar and the electronics boxes were fabricated, and the instrument test and calibration were conducted in 2021. By tuning the cryocooler frequencies, energy resolution better than 4.9 eV FWHM at 6 keV was demonstrated for all 36 pixels and high-resolution grade events, as well as energy-scale accuracy better than 2 eV up to 30 keV. The immunity of the detectors to microvibration, electrical conduction, and radiation was evaluated. The instrument was delivered to the spacecraft system in April 2022. The XMA was tested and calibrated separately. Its angular resolution is 1.27′, and the effective area of the mirror itself is 570 cm 2 at 1 keV and 424 cm 2 at 6 keV. We report the design and the major changes from the ASTRO-H SXS, the integration, and the results of the instrument test.

X-ray↗

Hyperfusogenic Mutations Destabilize the Postfusion Six-Helix Bundle of the Measles Virus Fusion Glycoprotein

Fusion of the host membrane and viral envelope by class I viral fusion proteins is driven by the assembly of a postfusion six-helix bundle formed through antiparallel interactions between N-terminal (HR1) and C-terminal (HR2) heptad-repeat regions. Although mutations in these regions of the measles virus (MeV) fusion (F) glycoprotein are known to promote neuropathogenic and hyperfusogenic phenotypes, their effects on postfusion core stability have not been systematically examined. Here, we combine peptide biophysics and X-ray crystallography to interrogate how mutations within the HR2 domain, present in native neuropathogenic MeV isolates (e.g., L454W and N462K) and laboratory-generated hyperfusogenic variants (e.g., L454M and T461A), influence postfusion 6HB assembly. Circular dichroism (CD) spectroscopy reveals that, with few exceptions, these mutations decrease postfusion core stability, despite their association with enhanced fusion activity. We also report the first crystal structure of the wild-type MeV postfusion core as well as structures of six hyperfusogenic variants, enabling high-resolution comparison of the molecular basis of destabilization. Structural analysis shows that these effects arise from localized perturbations to steric packing, hydrogen bonding networks, and helix-stabilizing interactions within HR2, while the overall 6HB architecture remains conserved. Together, these results indicate that hyperfusogenic mutations are not associated with stabilization of the postfusion state and are instead consistent with models in which hyperfusogenicity arises from a reduction in the energetic barrier to fusion, potentially through effects on prefusion stability or triggering efficiency. These findings establish key sequence-structure–stability relationships governing coiled-coil assembly and provide a framework for the design of HR1- and HR2-based fusion inhibitors.

Genetics↗

Orbital-Selective Instabilities and Spin Fluctuations at the Verge of Superconductivity in Interlayer-Expanded Iron Selenide

Understanding electron correlation-driven instabilities and their coupling to structural phases is essential for deciphering multiorbital pairing in unconventional superconductors. We investigate Li x (C 5 H 5 N) y Fe 2 Se 2 (x ∼ 0.6; y ∼ 0.7−0.9), a tetragonal β-FeSe intercalate with a superconducting transition temperature (T c = 39 K) closely tied to an expanded Fe-layer spacing (∼11.4 Å). High-resolution synchrotron Xray diffraction and core-level absorption spectroscopy reveal subtle lattice distortions on cooling without a symmetry-breaking transition. Instead, the material exhibits negative thermal expansion (NTE) in the two-dimensional Fe network below T S ∼ 70 K, and stiffening of local Se−Fe−Se bond dynamics near T c . The spatially incoherent rearrangement of FeSe 4 tetrahedra and the site-local fluctuations, signal reduced electron correlations compared to those of parent β-FeSe (T c = 8 K). Complementary X-ray emission spectroscopy, a fast local probe of Fe 3d valence states, detects persistent local Fe spin moments below T S , unlike quenching in related systems. These findings indicate that decoupling of Fe planes leads to an electronically driven lattice instability. The latter emerges as NTE induced from weak, orbital-selective localization of in-plane Fe 3d states rather than conventional transverse vibrations. Governed by Hund’s coupling, this selectivity permits coexistence of local spin fluctuations with itinerant d-electrons critical for enhancing T c . These results suggest that intercalation-driven d-orbital differentiation moderates electron correlations, providing a pathway to optimize the superconductivity in low-dimensional quantum materials.

36 MATERIALS SCIENCE↗

Shake-Down Spectroscopy as State- and Site-Specific Probe of Ultrafast Chemical Dynamics

Tracking the multifarious ultrafast electronic and structural changes occurring in a molecule during a photochemical transformation is a challenging endeavor that benefits from recent experimental and computational progress in time-resolved techniques. Measurements of valence electronic states, which provide a global picture of the bonding structure of the molecule, and core electronic states, which provide insight into the local environment, traditionally require different approaches and are often studied separately. Here, we demonstrate that X-ray pulses from a seeded free-electron laser (FEL) enable the measurement of high-resolution, time-resolved X-ray photoelectron spectra (XPS) that capture weak satellite states resulting from shake-down processes in a valence-excited molecule. This approach effectively combines the advantages of both valence- and core-state investigations. We applied this method to investigate photoexcited CS2 molecules, where the role of internal conversion (IC) and intersystem crossing (ISC) in determining the predissociation dynamics is controversial. We present XPS spectra from photoexcited CS2, obtained at the FERMI FEL. High-resolution measurements, compared to the corresponding spectra obtained from accurate multireference quantum chemical calculations, reveal that shake-down satellite channels are highly sensitive to both valence electronic and geometric changes. Previous studies of the predissociation dynamics have led to uncertain assignments of the branching between singlet and triplet excited states. We derive a propensity rule that demonstrates the spin-selectivity of the shake-downs. This selectivity allows us to unequivocally assign contributions from the bright and dark singlet excited states, with populations tracked along the predissociation dynamic pathway.

Thompson, Henry J. [Univ. of Southampton (United K↗

Demonstration of an AI-driven workflow for dynamic x-ray spectroscopy

X-ray absorption near edge structure (XANES) spectroscopy is a powerful technique for characterizing the chemical state and symmetry of individual elements within materials, but requires collecting data at many energy points which can be time-consuming. While adaptive sampling methods exist for efficiently collecting spectroscopic data, they often lack domain-specific knowledge about the structure of XANES spectra. Here we demonstrate a knowledge-injected Bayesian optimization approach for adaptive XANES data collection that incorporates understanding of spectral features like absorption edges and pre-edge peaks. We show this method accurately reconstructs the absorption edge of XANES spectra using only 15–20% of the measurement points typically needed for conventional sampling, while maintaining the ability to determine the x-ray energy of the sharp peak after the absorption edge with errors less than 0.03 eV, the absorption edge with errors less than 0.1 eV; and overall root-mean-square errors less than 0.005 compared to traditionally sampled spectra. Our experiments on battery materials and catalysts demonstrate the method’s effectiveness for both static and dynamic XANES measurements, improving data collection efficiency and enabling better time resolution for tracking chemical changes. This approach advances the degree of automation in XANES experiments, reducing the common errors of under- or over-sampling points near the absorption edge and enabling dynamic experiments that require high temporal resolution or limited measurement time.

Bayesian optimization↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Probing the local structure of Bi 2 O 3 chemical derivatives: the neglected cation sublattice

High-resolution synchrotron X-ray diffraction data confirm the stabilization of the average structure at ambient temperatures as a defect fluorite structure in ternary and quaternary oxides of Bi 2 O 3 , where some Bi cations are replaced with Dy 3+ and/or Er 3+ , Nb 5+ and W 6+ . Rietveld refinement of the diffraction data indicates that when the larger cation Er 3+ (0.89 Å) is replaced with smaller cations W 6+ (0.42 Å) and/or Nb 5+ (0.48 Å), the unit-cell parameter a, based on the relative ionic radii of the substituents, counterintuitively increases. Total scattering data show that the identity of the cation substituent is important in determining the positions of some Bi cations in the defect fluorite structure. Er 3+ and Dy 3+ cations induce monoclinic-like distortions that extend only locally in the Bi 3+ sublattice. X-ray absorption spectroscopy provides evidence that some Dy cations, in the δ phases, prefer to keep a similar local environment to that in the parent Dy 2 O 3 . W cations are found to be predominantly tetrahedrally coordinated in the δ phases explored in this work.

36 MATERIALS SCIENCE↗

Demonstration of full-scale spatiotemporal diagnostics of solid-density plasmas driven by an ultra-short relativistic laser pulse using an X-ray free-electron laser

Understanding the complex plasma dynamics in ultra-intense relativistic laser–solid interactions is of fundamental importance for applications of laser–plasma-based particle accelerators, the creation of high-energy-density matter, understanding planetary science, and laser-driven fusion energy. However, experimental efforts in this regime have been limited by the lack of accessibility of over-critical densities and the poor spatiotemporal resolution of conventional diagnostics. Over the last decade, the advent of femtosecond brilliant hard X-ray free-electron lasers (XFELs) has opened new horizons to overcome these limitations. Here, for the first time, we present full-scale spatiotemporal measurements of solid-density plasma dynamics, including preplasma generation with tens of nanometer scale length driven by the leading edge of a relativistic laser pulse, ultrafast heating and ionization at the main pulse arrival, the laser-driven blast wave, and transient surface return current-induced compression dynamics up to hundreds of picoseconds after interaction. These observations are enabled by utilizing a novel combination of advanced X-ray diagnostics including small-angle X-ray scattering, resonant X-ray emission spectroscopy, and propagation-based X-ray phase-contrast imaging simultaneously at the European XFEL-HED beamline station.

Huang, Lingen [Helmholtz-Zentrum Dresden-Rossendor↗

Nanotomography for Quantitative 3D Particle Reconstruction

Particulates are ubiquitous across fuel cycle operations and carry critical information about particle formation, processing, and potential proliferation-related activities. Traditional analytical techniques, including micro-Raman spectroscopy and standard electron microscopy, are often limited in spatial resolution or dimensionality, particularly when used to examine metallic or submicron-scale features. Understanding particle morphology, phase distribution, and internal porosity is essential for constraining formation conditions, thermodynamic environments, and material transport behavior. In this report, we demonstrate the application of plasma focused ion beam nanotomography to reconstruct micron-scale particulates at nanoscale resolution. Using high-resolution backscattered electron imaging and Avizo software, we obtained 3D reconstructions that enabled quantitative analysis of particle morphology, phase composition, and internal voids. Representative examples include a Ta particle with a large central void and a composite particle with embedded tetrahedral crystalline structures. These reconstructions reveal structural and compositional details that are inaccessible through conventional 2D imaging. The results demonstrate that nanotomography provides both qualitative and quantitative insights into particle formation and behavior. Using nanotomography, porosity and phase distributions can be quantified to inform models of particle density, transport, and solidification conditions. Beyond technical insights, the workflow developed here establishes a transferable capability for analyzing heterogeneous particles and has potential applications in bulk materials studies via x-ray computed tomography or other volumetric imaging modalities. Ongoing efforts are focused on optimizing the workflow to process multiple particles simultaneously, increasing throughput and statistical robustness. Overall, this work illustrates the power of nanotomography as a tool for connecting particulate morphology to formation mechanisms, composition, and transport, thereby strengthening analytical capabilities for nuclear forensics, fuel cycle analysis, and related scientific investigations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Crystallographic registry in epitaxial V3O5 thin films

Crystallographic orientation plays a central role in determining transport properties in correlated oxides with low-hysteresis metal–insulator transitions. Here, V3O5 thin films were grown on Al2O3 (0001) and their crystallographic registry was evaluated using x-ray diffraction and cross-sectional transmission electron microscopy. θ–2θ measurements show a single out-of-plane orientation defined by the (202) reflection. Azimuthal φ-scans of the V3O5 (310) reflection exhibit twelve discrete maxima over 360°, indicating a finite set of in-plane orientations imposed by the substrate symmetry. High-resolution TEM and fast Fourier transform analysis confirm crystallographic coherence at the film–substrate interface. The electrical conductivity exhibits a metal–insulator transition at TMIT ≈ 423 K with no measurable thermal hysteresis and a total change of ~1.6 orders of magnitude between 300 and 480 K. These results establish crystallographic registry in epitaxial V3O5 thin films and provide a structurally well-defined system for future studies of orientation-dependent transport.\r\nT

36 MATERIALS SCIENCE↗

Chromium-doped uranium dioxide fuels: A review

UO 2 doped with parts per million CR 2 O 3 powder is considered a potential near term accident tolerant fuel candidate. Here, the results of decades of industry and academic research into Cr-doped UO 2 are analyzed and their shortcomings are critiqued. Focusing on the incorporation mechanisms of Cr into the fuel matrix, we explore a mechanistic understanding of the characteristic properties of Cr-doped UO 2 , notably, enhanced fission gas retention attributed to enlarged grain sizes following sintering, along with marginal improvements in the thermophysical properties. The findings of recent X-ray Adsorption Near Edge Spectroscopy studies were compared and put into conversation with historic data regarding the incorporation of Cr in UO 2 . On the basis of defect mechanisms, the case is made for the substitutional incorporation of Cr governing the lattice solubility but not the enhanced U diffusivity. Instead, Cr/CR 2 O 3 redox chemistry in a well-defined oxygen potential explains the differences in the U diffusivity and O/M ratio. The primary mechanism of doping enhanced grain growth is found to be liquid assisted sintering due to a CRO (1) eutectic phase at the grain boundaries. The role of inhomogeneities in Cr concentration in UO 2 at various length scales across the materials microstructure is highlighted and connected to promising experimental and modeling work to fill in the gaps in the current understanding of Cr-doped UO 2 . The review considers both the open scientific questions and engineering applications to illustrate the deep connections between the practice and theory in the design of accident tolerant nuclear fuels. In conclusion, the review ends with an outline of future works that combine meticulous irradiation studies and high resolution experiments with next generation modeling and simulations techniques empowered by machine learning advances to accelerate the fabrication and adoption of Cr-doped UO 2 light water reactors.

Cleveland, Mack Wesley [Massachusetts Inst. of Tec↗

Mapping the Perseus galaxy cluster with XRISM: Gas kinematic features and their implications for turbulence

We present extended gas kinematic maps of the Perseus cluster based on a combination of five new XRISM/Resolve pointings observed in 2025 with four performance verification datasets from 2024, totaling a net exposure of 745 ks. To date, Perseus remains the only cluster that has been extensively mapped out to ≃0.7 r 2500 by XRISM/Resolve, while simultaneously offering sufficient spatial resolution to resolve gaseous substructures driven by mergers and active galactic nucleus (AGN) feedback. Our observations cover multiple radial directions and a broad range of dynamical scales, enabling us to characterize the kinematic properties of the intracluster medium up to a scale of ∼500 kpc. In the measurements, we detected high-velocity dispersions (≃300km s −1 ) in the eastern region of the cluster that are spatially coincident with the extended X-ray surface brightness excess and correspond to a nonthermal pressure fraction of ≃7 − 13%. The velocity field outside the AGN-dominant region can be effectively described by a single, large-scale kinematic driver based on the velocity structure function, which statistically favors an energy injection scale of at least a few hundred kpc. The estimated turbulent dissipation energy is comparable to the gravitational potential energy released by a recent merger, implying a significant role of turbulent cascade in the merger energy conversion. In the bulk velocity field, we observed a dipole-like pattern along the east-west direction with an amplitude of ≃ ± 200 − 300 km s −1 , indicating rotational motions induced by the recent merger event. This feature constrains the viewing direction to ≃30° −50° relative to the normal of the merger plane. Our hydrodynamic simulations suggest that Perseus has experienced at least two energetic mergers since redshift z ∼ 1, the most recent of which is associated with the radio galaxy IC310, in agreement with recent SRG/eROSITA findings. This study showcases exciting scientific opportunities for future missions with high-resolution spectroscopic capabilities (e.g., HUBS, LEM, and NewAthena).

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Pattern-enhanced Resonant Soft X-ray Scattering for Operando monitoring of electrochemical solid-liquid interfaces

Unveiling interfaces at sub-nanometer scales is essential for advancing the understanding of complex chemical transformations. However, characterizing solid-liquid interfaces with high dimensional sensitivity and temporal resolution remains challenging, due to their dynamic nature and inaccessibility by conventional probes. Here we present an approach, Pattern-enhanced Resonant Soft X-ray Scattering, to overcome the challenges. Rooted in a “sample-as-optics” philosophy, this technique utilizes precisely engineered line-grating nanopatterns to modulate near-field X-ray illumination, coherently enhancing scattering signals from the line-gratings. We implement the method using Ni line-grating nanopatterns in electrochemical water oxidation. The periodic nanostructures serve as diffractive optical elements to reveal the Ni oxidation gradients and structural dynamics at the electrode-electrolyte interfaces. Finite-element simulations corroborate the observed trends by modeling variations in compositions and structures during electrocatalysis. Through integrating advanced sample design with coherent wave nature of soft X-rays, our approach opens accessible pathways to operando exploring chemical evolution and sub-nanometer dimensional variations simultaneously in electrochemical systems. This non-destructive method is efficient and element-specific, making it valuable for probing chemical and dimensional dynamics with appropriate modeling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measuring X-Ray Emission Line Shapes in Neutral Species for XRISM Calibration

Space X-ray spectrometers such as the Resolve instrument on XRISM require precise calibration in order to interpret the spectra of astrophysical objects. Key components of the calibration are the energy scale and the core line spread function, both of which vary with photon energy. A major issue in the calibration of high-resolution spectrometers is locating good calibrators with well-known and stable intrinsic line shapes. Neutral fluorescence is widely used, but inner-shell transitions in neutral atoms often exhibit complex, poorly documented line shapes that vary with excitation conditions. Here, in this study, we present empirical measurements of K-shell transitions in neutral O and F below 1 keV using an engineering model XRISM calorimeter array, an electron bombardment modulated X-ray source, and an electron beam ion trap (EBIT) to provide a precise energy reference. In addition, we report measurements of the Mo Lα complex with the transition-edge microcalorimeter spectrometer (TEMS), which reveal strong satellite structure and sensitivity of the line shape to the incident exciting spectrum. Together, these results demonstrate the need for empirical line-shape models, highlight the nonstationary nature of neutral fluorescence features, and define a path toward developing transfer standards for XRISM and future precision instruments such as Athena/X-IFU.

Astronomy and AstroPhysics↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗