Search NASA⌕ Search

SEARCH · Search NASA

Results for “high-concentration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Locally Confined Polysulfide-Reactive Electrolytes for Shuttle-Free Sodium–Sulfur Batteries

Sodium-sulfur batteries promise high-energy-density and sustainable electrochemical energy storage but suffer from uncontrolled polysulfides dissolution and high sodium reactivity. These challenges fundamentally originate from poor electrolyte-electrode compatibility. Current electrolyte research inadequately addresses the trade-off between minimal polysulfides solvation and stabilizing sodium interfaces. Here, we present a locally-confined polysulfide-reactive electrolyte strategy that mediates the polysulfide dissolution dynamics and sodium stability by leveraging an electrophilic solvating species with a localized high-concentration electrolyte. This design enables shuttle-free cell operation by synergistically restricting the global solvating power of the electrolyte through intermolecular interactions and locally scavenging sparingly dissolved polysulfides via electrolyte electrophilicity. The precisely confined surface reaction facilitates a protective cathode-electrolyte interface, realizing a quasi-solid-state sulfur conversion in our liquid ether-based electrolyte, which crucially avoids crossover-induced catastrophic sodium-metal degradation. The proposed electrolyte demonstrates long-term cycling of high-mass-loading sulfur cathodes (> 3 mg S cm −2 with commercial carbon host and 70 wt% sulfur content), which afford 710 mA h g −1 over 400 cycles in coin cells and steady pouch cell operation over 180 cycles. Furthermore, this work establishes a scalable electrolyte design protocol that regulates the reaction chemistry of highly reactive electrodes, offering a pathway toward sustainable renewable energy storage.

25 ENERGY STORAGE↗

Mass Spectrometric Determination of Site-Specific O -Acetylation in Rhamnogalacturonan I Oligomers

O-acetylation, a common modification in rhamnogalacturonan I (RG-I), is critical for various biological processes, including plant growth, stress responses, and pathogen defense. Precise determination of the degree and specific positions of acetylation is therefore essential. To date, nuclear magnetic resonance (NMR) and tandem mass spectrometry have been employed to identify O-acetyl positions in pectin oligosaccharides. Although NMR is effective, it requires pure, high-concentration samples. Tandem mass spectrometry (MS), which uses smaller sample amounts, faces challenges due to O-acetyl migration between monosaccharide positions. The multiple steps in pectin sample analysis can further promote O-acetyl migration, especially near free hydroxyl groups. Moreover, during tandem MS, O-acetyl groups may detach, complicating the accurate tracking. This study presents an approach to lock O-acetyl groups by introducing trideuteroacetyl and propionyl substituents onto free hydroxyls of RG-I or partially acetylated RG-I. By combining matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS and electrospray ionization (ESI) MS with MS/MS or tandem mass spectrometry (MSn), we devised a way to determine the monosaccharide sequence in the oligomer and the precise positions of O-acetyl groups in partially acetylated RG-I. This method enables the study of the regiospecificity of recombinant pectin O-acetyltransferases and can be applied to other oligosaccharides to determine acyl positions.

O-acetylation↗

Hydrotrope-enabled high concentration aqueous electrolytes for reversible and sustainable iron metal anodes

Iron metal-based energy storage devices hold great potential in stationary grid-scale sustainable energy due to the high theoretical specific capacity, ultralow cost, and abundance of iron. However, their practical deployment is limited by the poor reversibility of iron plating and stripping, as well as competitive hydrogen evolution. Here we introduce the concept of hydrotropy into iron electrolytes by developing an environmentally friendly and cost-effective high-concentration ferrous sulfate electrolyte using urea as a hydrotropic agent. The designed electrolyte increases the Coulombic efficiency of iron metal electrodes to approximately 96.5%, compared with ~84.6% for the dilute electrolyte. Molecular dynamics simulations and Raman spectroscopy illustrate that urea regulates the competitive coordination of anions and urea in the iron solvation sheath, while reconstructing the hydrogen-bond network in free water molecules. This reduces the activity of both solvated and free water, thereby alleviating hydrogen evolution. Moreover, the coordinated anions and urea molecules facilitate the in-situ formation of an organic-inorganic hybrid protective layer on the metallic iron, establishing a physical barrier against water and promoting homogeneous interfacial reactions. This work demonstrates an appealing opportunity to design cost-effective and high-performance electrolytes and propels the practical application of iron metal-based energy storage devices.

Feng, Guangxia [Stanford Univ., CA (United States)↗

Single-phase local-high-concentration solid polymer electrolytes for lithium-metal batteries

Solid polymers are promising electrolytes for Li-metal batteries, but they have limitations: they cannot simultaneously achieve high ionic conductivity, good mechanical strength and compatibility with high-voltage cathodes while suppressing Li dendrites. Here, we design a class of locally high-concentration solid polymer electrolytes based on polymer blends, which are termed Li-polymer in F diluter (LPIFD). The Li-polymer (polymer-in-salt) ensures continuous Li-ion conduction channels and contributes to the solid electrolyte interphase (SEI), and the F diluter (inert fluorinated polymer) adds mechanical strength. Studies reveal that a single-phase LPIFD, which is based on a miscible polymer blend, lacks phase boundaries and forms an organic-less and LiF-rich SEI, effectively suppressing lithium dendrites. The single-phase LPIFD delivers ionic conductivity of 3.0 x 10 -4 S cm -1 and enables the Li anode to reach a high coulombic efficiency of 99.1% and a critical current density of 3.7 mA cm -2 . Furthermore, the ability to form an F-rich cathode electrolyte interphase allows LiNi 0.8 Co 0.1 Mn 0.1 O 2 ||Li cells to achieve a cycle life of 450 cycles at a high operating voltage of 4.5 V. In conclusion, this design will inspire efforts to commercialize polymer electrolytes for high-energy Li-metal batteries.

25 ENERGY STORAGE↗

Quantitative insights for diagnosing performance bottlenecks in lithium–sulfur batteries

Lithium–sulfur (Li–S) batteries hold significant promise for electric vehicles and aviation due to their high energy density and cost-effectiveness. However, understanding the root causes of performance degradation remains a formidable challenge, as the interplay of multiple factors obscures key failure mechanisms. A major limitation has been the inability to quantify soluble sulfur species within practical detection limits accurately and to correlate electrochemical processes with associated physical inventory changes. Here, we introduce the high-performance liquid chromatography-ultraviolet spectroscopy and gas chromatography sequential characterization (HUGS) toolkit, capable of precisely quantifying seven distinct sulfur and polysulfide species at concentrations as low as 40 ppb. HUGS has been successfully applied to practical coin and pouch cells without requiring cell modification. Furthermore, our self-developed software, Dr HUGS, enhanced the data analysis speed by over 30 times, enabling multi-source data integration and delivering comprehensive analysis results within minutes. Using HUGS, we identify significant capacity losses from inactive lithium and sulfur during initial cycles and sulfide-rich solid–electrolyte interphase (SEI) formation on the anode during later cycles. Notably, our findings reveal that soluble polysulfides have minimal contributions to capacity loss, challenging long-standing assumptions. Moreover, HUGS demonstrates that constant-pressure setups in Li–S pouch cells improve compositional uniformity compared to constant-gap configurations. For sulfurized polyacrylonitrile (SPAN) cathodes, unique issues such as non-sulfide SEI formation and lithium pulverization are observed, which can be mitigated through localized high-concentration electrolytes to enhance lithium inventory retention. By enabling precise quantification of critical inventory components, HUGS provides transformative insights into failure mechanisms across various electrolytes and cathode chemistries, guiding rational design strategies for next-generation energy storage systems.

25 ENERGY STORAGE↗

Reexpansion of charged nanoparticle assemblies in concentrated electrolytes

Electrostatic forces in solutions are highly relevant to a variety of fields, ranging from electrochemical energy storage to biology. However, their manifestation in concentrated electrolytes is not fully understood, as exemplified by counterintuitive observations of colloidal stability and long-ranged repulsions in molten salts. Highly charged biomolecules, such as DNA, respond sensitively to ions in dilute solutions. Here, we use non-base-pairing DNA-coated nanoparticles (DNA-NP) to analyze electrostatic interactions in concentrated salt solutions. Despite their negative charge, these conjugates form colloidal crystals in solutions of sufficient divalent cation concentration. We utilize small-angle X-ray scattering (SAXS) to study such DNA-NP assemblies across the full accessible concentration ranges of aqueous CaCl 2 , MgCl 2 , and SrCl 2 solutions. SAXS shows that the crystallinity and phases of the assembled structures vary with cation type. For all tested salts, the aggregates contract with added ions at low salinities and then begin expanding above a cation-dependent threshold salt concentration. Wide-angle X-ray scattering (WAXS) reveals enhanced positional correlations between ions in the solution at high salt concentrations. Complementary molecular dynamics simulations show that these ion–ion interactions reduce the favorability of dense ion configurations within the DNA brushes below that of the bulk solution. Measurements in solutions with lowered permittivity demonstrate a simultaneous increase in ion coupling and decrease in the concentration at which aggregate expansion begins, thus confirming the connection between these phenomena. Our work demonstrates that interactions between charged objects continue to evolve considerably into the high-concentration regime, where classical theories project electrostatics to be of negligible consequence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of Acid Etching Time in Ti 3 C 2 MXene’s Interlayer Spacing and Conductivity

Materials with sheet-like morphologies often form interconnected networks of layers or flakes, offering continuous channels for electron and ion transport in electrochemical energy storage applications. One such material is the recently discovered class of 2-D transition metal carbides/nitrides, called MXene, whose general formula is M n+1 X n T x (where M = transition metal; n = 1, 2, or 3; X = carbon or nitrogen; and T x = termination group such as –F, –OH, and/or =O). Ti 3 C 2 , one of the most studied MXene, can be synthesized by selectively etching the aluminum layer in Ti 3 AlC 2 (also called MAX phase). The most straightforward technique to exfoliate this layer is by wet-chemical etching with high-concentration hydrofluoric acid (HF). In this study, the effect of etching time on the morphology, interlayer spacing, and electrical conductivity of the resultant MXene was studied.

25 ENERGY STORAGE↗

A round-robin approach provides a detailed assessment of biomolecular small-angle scattering data reproducibility and yields consensus curves for benchmarking

Through an expansive international effort that involved data collection on 12 small-angle X-ray scattering (SAXS) and four small-angle neutron scattering (SANS) instruments, 171 SAXS and 76 SANS measurements for five proteins (ribonuclease A, lysozyme, xylanase, urate oxidase and xylose isomerase) were acquired. From these data, the solvent-subtracted protein scattering profiles were shown to be reproducible, with the caveat that an additive constant adjustment was required to account for small errors in solvent subtraction. Further, the major features of the obtained consensus SAXS data over the q measurement range 0–1 Å −1 are consistent with theoretical prediction. The inherently lower statistical precision for SANS limited the reliably measured q -range to <0.5 Å −1 , but within the limits of experimental uncertainties the major features of the consensus SANS data were also consistent with prediction for all five proteins measured in H 2 O and in D 2 O. Thus, a foundation set of consensus SAS profiles has been obtained for benchmarking scattering-profile prediction from atomic coordinates. Additionally, two sets of SAXS data measured at different facilities to q > 2.2 Å −1 showed good mutual agreement, affirming that this region has interpretable features for structural modelling. SAS measurements with inline size-exclusion chromatography (SEC) proved to be generally superior for eliminating sample heterogeneity, but with unavoidable sample dilution during column elution, while batch SAS data collected at higher concentrations and for longer times provided superior statistical precision. Careful merging of data measured using inline SEC and batch modes, or low- and high-concentration data from batch measurements, was successful in eliminating small amounts of aggregate or interparticle interference from the scattering while providing improved statistical precision overall for the benchmarking data set.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments

The goal of our activities in FY24 was to enable advanced materials accountancy for molten salt reactors (MSRs) through the development and optimization of robust flow-enhanced electrochemical sensors (FEES) using a safeguards-focused sensor testing platform called the modular flow instrumentation testbed (MFIT). Flow-enhanced electrochemical sensors are a type of electroanalytical sensor that have been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. This year, the FEES technical readiness was increased by (1) demonstrating the use of optimized sensor techniques to achieve measurements in very high-concentration MSR-relevant salts, (2) leveraging new multimodal sensors and automation approaches to reduce measurement uncertainties, and (3) fabricating and deploying sensors to industrial partners to improve their ability to make measurements in challenging environments. Additionally, we also ran the sensors during complex system operations involving combined flow and purification activities to demonstrate safeguards-relevant measurements during online processing for MSRs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Vertical Characterization of Flow and Contaminant Concentration in New Hanford Extraction Wells

Effective groundwater remediation should focus on high-concentration, low-permeability zones within the aquifer, as these areas often present significant challenges to contaminant removal. Characterizing the vertical distribution of contamination in an aquifer is therefore critical for optimizing and monitoring pump-and-treat (P&T) systems to meet target cleanup timelines. Flow patterns driven by hydraulic gradients and variations in permeability are described to provide insight into contaminant mass removal from long-screened wells. The objective of this multi-phase work is to provide actionable recommendations for improving remedy performance monitoring and P&T operations, which ongoing evaluations will address. This report summarizes the preliminary results of vertical flow and contaminant distribution monitoring in new extraction wells at the Hanford Site.

54 ENVIRONMENTAL SCIENCES↗

Solvated Ionic Liquid-based Electrolytes: Experimental Characterization, Atomistic Modeling and Applications in Energy Storage

This study aimed on understanding the molecular structure and transport mechanisms of high-concentration lithium electrolytes, with a particular focus on solvate ionic liquids (SILs) based on glyme solvents, for use in next-generation, high-voltage energy storage systems. The hypothesis is that the composition of the solvents in these electrolytes can be designed and adjusted to control cation solvation, enabling charge transport via an ion-hopping mechanism. This mechanism resembles Grotthuss conduction of protons in water and is independent of electrolyte viscosity. The experimental studies employed linear and nonlinear infrared spectroscopy (FTIR and 2D IR), electrochemical measurements, and vibrational probes.

25 ENERGY STORAGE↗

Comparison of Sub-Ppm Instrument Response Suggests Higher Detection Limits Could Be Used to Quantify Methane Emissions from Oil and Gas Infrastructure

Quantifying and controlling fugitive methane emissions from oil and gas facilities remains essential for addressing climate goals, but the costs associated with monitoring millions of production sites remain prohibitively expensive. Current thinking, supported by measurement and simple dispersion modelling, assumes single-digit parts-per-million instrumentation is required. To investigate instrument response, the inlets of three trace-methane (sub-ppm) analyzers were collocated on a facility designed to release gas of known composition at known flow rates between 0.4 and 5.2 kg CH 4 h –1 from simulated oil and gas infrastructure. Methane mixing ratios were measured by each instrument at 1 Hertz resolution over nine hours. While mixing ratios reported by a cavity ring-down spectrometer (CRDS)-based instrument were on average 10.0 ppm (range 1.8 to 83 ppm), a mid-infrared laser absorption spectroscopy (MIRA)-based instrument reported short-lived mixing ratios far larger than expected (range 1.8 to 779 ppm) with a similar nine-hour average to the CRDS (10.1 ppm). We suggest the peaks detected by the MIRA are likely caused by a micrometeorological phenomenon, where vortex shedding has resulted in heterogeneous methane plumes which only the MIRA can observe. Further analysis suggests an instrument like the MIRA (an optical-cavity-based instrument with cavity size ≤10 cm3 measuring at ≥2 Hz with air flow rates in the order of ≤0.3 slpm at distances of ≤20 m from the source) but with a higher detection limit (25 ppm) could detect enough of the high-concentration events to generate representative 20 min-average methane mixing ratios. Even though development of a lower-cost, high-precision, high-accuracy instrument with a 25 ppm detection threshold remains a significant problem, this has implications for the use of instrumentation with higher detection thresholds, resulting in the reduction in cost to measure methane emissions and providing a mechanism for the widespread deployment of effective leak detection and repair programs for all oil and gas infrastructure.

03 NATURAL GAS↗

EASTERN NORTH ATLANTIC (ENA) CONDENSATION PARTICLE COUNTER (CPC) with the AEROSOL MASK (ENA-AM) for the YEAR 2017

The Eastern North Atlantic (ENA) central facility is periodically affected by episodes of local aerosols. High-concentration aerosol events associated with potential local aerosol sources are sampled by the Concentration Particle Counter (CPC) and can be observed in the high-time-resolution data. In an effort to remove aerosol data that is not regionally representative from the CPC data, an aerosol mask (ENA-AM) has been previously developed and validated during the ACE-ENA campaing (Gallo et al., 2020). The ENA-AM is a standard deviation algorithm based on the statistically different behavior of adjacent data points used to determine periods when the measurements are impacted by local aerosols. This file contain one-minute time resolution submicron aerosol particle concentration datasets from the CPC for the year 2017, and the corresponding ENA-AM datasets to remove datapoints affected by local aerosol sources.

54 ENVIRONMENTAL SCIENCES↗

EASTERN NORTH ATLANTIC (ENA) CONDENSATION PARTICLE COUNTER (CPC) with the AEROSOL MASK (ENA-AM) for the YEAR 2018

The Eastern North Atlantic (ENA) central facility is periodically affected by episodes of local aerosols. High-concentration aerosol events associated with potential local aerosol sources are sampled by the Concentration Particle Counter (CPC) and can be observed in the high-time-resolution data. In an effort to remove aerosol data that is not regionally representative from the CPC data, an aerosol mask (ENA-AM) has been previously developed and validated during the ACE-ENA campaing (Gallo et al., 2020). The ENA-AM is a standard deviation algorithm based on the statistically different behavior of adjacent data points used to determine periods when the measurements are impacted by local aerosols. This file contain one-minute time resolution submicron aerosol particle concentration datasets from the CPC for the year 2018, and the corresponding ENA-AM datasets to remove datapoints affected by local aerosol sources.

54 ENVIRONMENTAL SCIENCES↗

EASTERN NORTH ATLANTIC (ENA) CONDENSATION PARTICLE COUNTER (CPC) with the AEROSOL MASK (ENA-AM) for the YEAR 2016

The Eastern North Atlantic (ENA) central facility is periodically affected by episodes of local aerosols. High-concentration aerosol events associated with potential local aerosol sources are sampled by the concentration particle counter (CPC) and can be observed in the high-time-resolution data. In an effort to remove aerosol data that is not regionally representative from the CPC data, an aerosol mask (ENA-AM) has been previously developed and validated during the ACE-ENA campaign (Gallo et al. 2020). The ENA-AM is a standard deviation algorithm based on the statistically different behavior of adjacent data points used to determine periods when the measurements are impacted by local aerosols. This file contains one-minute-time-resolution submicron aerosol particle concentration data sets from the CPC for the year 2016, and the corresponding ENA-AM data sets to remove data points affected by local aerosol sources.

54 ENVIRONMENTAL SCIENCES↗

Crossover Effects in Lithium–Metal Batteries with a Localized High Concentration Electrolyte and High–Nickel Cathodes

While crossover effects, such as transition–metal dissolution, are well–understood in lithium–ion batteries, there is a limited understanding of the effect of crossed–over chemical species in cells with oxide cathodes and lithium–metal anodes. In this work, the effects of cathode–to–anode and anode–to–cathode crossover are explored in cells with a high–nickel cathode, lithium–metal anode, and a localized high–concentration electrolyte (LHCE). Dramatic differences are found among cells; a lithium–metal anode paired with a high–nickel cathode has three times less solid–electrolyte interphase growth than a lithium–metal anode paired with lithium metal. Meanwhile, the cathode paired with lithium metal has 2–3 times higher capacity fade than the same cathode paired with graphite. Decomposition and crossover of the FSI salt is identified as the main source of these changes. The fluorine in the salt is first stripped off at the lithium–metal anode, and the remaining sulfur and nitrogen cross over to the cathode. Although the reduction in fluorine content harms the surface stability of the cathode, the lithium–metal anode benefits from the increased fluorine content. Furthermore, because the lithium–metal anode is typically the bottleneck for cells with thin lithium, crossover is a major factor in the enhanced performance of lithium–metal batteries with LHCE.

25 ENERGY STORAGE↗

A Systematic Study on the Effects of Solvating Solvents and Additives in Localized High‐Concentration Electrolytes over Electrochemical Performance of Lithium‐Ion Batteries

Abstract Localized high‐concentration electrolytes (LHCEs) based on five different types of solvents were systematically studied and compared in lithium (Li)‐ion batteries (LIBs). The unique solvation structure of LHCEs promotes the participation of Li salt in forming solid electrolyte interphase (SEI) on graphite (Gr) anode, which enables solvents previously considered incompatible with Gr to achieve reversible lithiation/delithiation. However, the long cyclability of LIBs is still subject to the intrinsic properties of the solvent species in LHCEs. Such issue can be readily resolved by introducing a small amount of additive into LHCEs. The synergetic decompositions of Li salt, solvating solvent and additive yield effective SEIs and cathode electrolyte interphases (CEIs) in most of the studied LHCEs. This study reveals that both the structure and the composition of solvation sheaths in LHCEs have significant effect on SEI and CEI, and consequently, the cycle life of energetically dense LIBs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pressure effects on lithium anode/nickel-manganese-cobalt oxide cathode pouch cells through fixture design

Applying external pressure to a pouch cell results in improved performance, implicating systems-level design of batteries. Here, different formats and amounts of external pressure to Li-Li x Ni 0.8 Mn 0.1 Co 0.1 O 2 (Li-NMC811) pouch cells were studied under lean electrolyte conditions. Due to the more uniform lithium plating/stripping, a constant gap fixture that retains the distance of the frame during cycling performed greater than a constant pressure fixture that retains applied pressure to the cell. In addition, the use of flexible foam in a constant gap fixture revealed enhanced cycle life at 10 psi; however, at 30 psi, the use of a rigid plate extended cycle life to over 250 cycles, while the foam severely shortened cycle life. This discrepancy with pressure was proven to be driven by stress distribution on cell components. The failure mechanisms and the effects of pressure fixture design on cell components were unveiled, shedding light on improving high-energy battery performance through at-scale fixture design.

25 - ENERGY STORAGE↗