Search NASA⌕ Search

SEARCH · Search NASA

Results for “higher harmonics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Advanced Design for the WIQ Magnet With Steering Corrector Function

The Facility for Rare Isotopes Beams (FRIB) delivers heavy-ion primary beams at energies of up to 300 MeV/u at 10 kW of beam power to generate rare isotope beams for experiments and will eventually operate at beam power of 400 kW. The preseprator of the Advanced Rare Isotope Separator (ARIS) is equipped with six warm-iron quadrupole (WIQ) singlets and two dipoles integrated right after the production target. They have a compact structure and operate in a high radiation vacuum environment within a hot cell having remote handling capabilities for installation and maintenance. Due to asymmetry with respect to the quadrupole poles, nested sextupole excitations in WIQs induce vertical dipoles that offset the centroid trajectory; Magnet misalignments also result in trajectory offsets. Such offsets degrade separator performance but can be minimized by changing the current distribution on sextupole and octupole coils. In this work, we show how modifications to the WIQ coil design can allow superimposed dipole fields to be included to the octupole and sextupole windings, as well as addition of dipole components by splitting coil currents over groups with separator power supplies. Adjusting the group currents can cancel the sextupole-induced vertical dipole component which can be as high as 0.012 Tm. Octupole coil changes may superimpose a horizontal dipole integrated strength as high as 0.0332 Tm. Unwanted higher harmonics induced as a side effect of the new design are kept to a minimum such that separator performance is preserved as much as possible.

Accelerator magnets↗

Rapid simulations of hyperspectral near-field images of three-dimensional heterogeneous surfaces

The scattering-type scanning near-field optical microscope (s-SNOM) has emerged as a powerful tool for resolving nanoscale inhomogeneities in laterally heterogeneous samples. However, most analytical models used to predict the scattering near-field signals are assuming homogenous landscapes (bulk materials), resulting in inconsistencies when applied to samples with more complex configurations. In this work, we combine the point-dipole model (PDM) to the finite-element method (FEM) to account for the lateral and vertical heterogeneities while keeping the computation time manageable. Full images, spectra, or hyperspectral line profiles can be simulated by calculating the self-consistent dipole radiation demodulated at higher harmonics of the tip oscillation, mimicking real experimental procedures. Using this formalism, we clarify several important yet puzzling experimental observations in near-field images on samples with rich typography and complex material compositions, heterostructures of two-dimensional material flakes, and plasmonic antennas. The developed method serves as a basis for future investigations of nano-systems with nontrivial topography.

36 MATERIALS SCIENCE↗

Ultracold Storage Ring

The modern ring upgrades aim at reaching beam low emittance while paying little attention to the beam energy spread. The purpose of this note is to conjecture on a possibility of designing a storage ring with ultimately small energy spread. This might be of interest with respect to the following two applications: increasing brightness and coherence of radiation at higher harmonics of undulator radiation and a potential of building a soft X-ray FEL on a storage ring. Throughout the tech note we are taking a 3 GeV storage ring of the NSLS-II size as an example.

43 PARTICLE ACCELERATORS↗

Electron beam emittance at operational intensity in fourth-generation synchrotron light sources

For synchrotron light sources, the brightness of user X-ray beams is primarily determined by the electron beam emittance and energy spread at operational intensity. A common feature of fourth-generation synchrotrons is the short length of electron bunches combined with a very small transverse beam size. Consequently, the particle density is much higher than in machines of previous generations, leading to strong collective effects that significantly increase the emittance and limit the achievable brightness at operational beam intensity. In this article, we summarize our studies of the emittance scaled with the beam energy and intensity, taking into account the effects of intrabeam scattering, beam-impedance interaction, and bunch lengthening provided by higher-harmonic RF systems, to identify optimal combinations of machine and beam parameters.

43 PARTICLE ACCELERATORS↗

Accelerator Physics at NSLS-II: Research Accomplishments in 2023

NSLS-II accelerator physicists provided operation support for user operations and machine start-ups, carried out routine lattice characterization, and produced regular reports on beam dynamics. The commissioning of a superconducting wiggler for the HEX beamline is complete, and the wiggler effects on beam dynamics have been studied. A Facility Improvement Project for absolute lattice characterization has been approved and funded. We implemented and tested a new orbit-based technique of lattice characterization and correction. We developed a theory to calculate the beam-induced power in ceramic vacuum chambers and a new convergence map technique for nonlinear lattice characterization. We continued working on the NSLS-II upgrade including lattice development, commissioning a low-energy complex bend prototype, analyzing beam sensitivity to various errors, implementing higher-harmonic RF cavities, studying collective effects, and assessing FEL options. We also supported lattice optimization and beam diagnostics development for the EIC project. Main research accomplishments achieved in 2023, are summarized in this report.

43 PARTICLE ACCELERATORS↗

Accelerator Physics at NSLS-II: Research Accomplishments in 2024

NSLS-II accelerator physicists advanced the operational performance and scientific capabilities of NSLS-II, providing regular lattice characterization and correction, injec tion optimization, vertical emittance control, and beam dynamics reports with corre lation analysis. We further developed advanced lattice characterization techniques and studies on impedance, beam-induced heating, and higher-harmonic RF cavity effects to support NSLS-II and its high-brightness upgrade. The assessment of free-electron laser options for the NSLS-II upgrade has been completed. We carried out comprehensive studies focused on complex bend magnets and novel efficient injection schemes for next-generation low-emittance synchrotrons. We contributed to the Electron-Ion Collider project, including Electron Storage Ring lattice design, beam diagnostics, and injector studies. The physicists participated in international collaborations, including the development of Python-based Middle Layer software, and participated in key accel erator physics workshops and scientific meetings. The main research accomplishments achieved in 2024 are summarized in this report.

43 PARTICLE ACCELERATORS↗

Extreme Longitudinal Compression of Optimized Beams for MEV Ultrafast Electron Diffraction (Final Technical Report)

We worked out the design of a high repetition rate MeV energy ultrafast electron diffraction instrument based on the existing Cornell photoinjector, which can readily be applied to the presented findings. This example is a blueprint of other similarly arranged UED setups. Using particle tracking simulations in conjunction with multiobjective genetic algorithm optimization, we explored the smallest bunch lengths, emittance, and probe spot sizes achievable. As two limits, we defined stroboscopic conditions (with single electrons per pulse) and operation with 10 5 electrons per bunch which may be suitable for single-shot diffraction images. In the stroboscopic case, the flexibility provided by the many cavity bunching and acceleration allows for longitudinal phase space linearization without a higher harmonic field, providing sub-fs bunch lengths at the sample. Given low emittance photoemission conditions, these small bunch lengths can be maintained with probe transverse sizes at the single micron (1 μm) scale and below. In the case of 10 5 electrons per pulse, we simulated state-of-the-art 5D brightness conditions: rms bunch lengths of 10 fs with 3-nm normalized emittances, while permitting repetition rates as high as 1.3 GHz. We showed that in conjunction with collimating apertures, a novel focusing scheme achieves very high-quality emittance compensation for the central core of the beam composing 40% of particles, for a resulting beam size of 5 μm (rms). Finally, to aid in the design of new SRF-based ultrafast electron diffraction machines, we simulated the trade-off between the number of cavities used and achievable bunch length and emittance. In the longitudinal dimension, we made use of the fact that MeV UED requires much lower energy than the 15-MeV maxi mum energy of Cornell’s CBETA injector, and we may therefore use several of the SRF cavities for bunch length compression. In practice, we used a genetic optimization algorithm to choose the phases and amplitudes of the cavities appropriately for optimal bunching. In the zero space charge case, we found that bunching and acceleration are distributed across the six cavities in a way that produces a linearizing effect. And we showed that the ultimate bunch length can be limited by time-of-flight differences arising from transverse size and transverse momentum spread. The space charge code developed and used for this development is now permanent part of the Bmad accelerator simulation code and has already contributed to other developments, e.g., for the EIC electron cooler design.

43 PARTICLE ACCELERATORS↗

Evidence of Nonlinear Seismic Effects in the Earth from Downhole Distributed Acoustic Sensors

Seismic velocities and elastic moduli of rocks are known to vary significantly with applied stress, which indicates that these materials exhibit nonlinear elasticity. Monochromatic waves in nonlinear elastic media are known to generate higher harmonics and combinational frequencies. Such effects have the potential to be used for broadening the frequency band of seismic sources, characterization of the subsurface, and safety monitoring of civil engineering infrastructure. However, knowledge on nonlinear seismic effects is still scarce, which impedes the development of their practical applications. To explore the potential of nonlinear seismology, we performed three experiments: two in the field and one in the laboratory. The first field experiment used two vibroseis sources generating signals with two different monochromatic frequencies. The second field experiment used a surface orbital vibrator with two eccentric motors working at different frequencies. In both experiments, the generated wavefield was recorded in a borehole using a fiber-optic distributed acoustic sensing cable. Both experiments showed combinational frequencies, harmonics, and other intermodulation products of the fundamental frequencies both on the surface and at depth. Laboratory experiments replicated the setup of the field test with vibroseis sources and showed similar nonlinear combinations of fundamental frequencies. Amplitudes of the nonlinear signals observed in the laboratory showed variation with the saturating fluid. These results confirm that nonlinear components of the wavefield propagate as body waves, are likely to generate within rock formations, and can be potentially used for reservoir fluid characterization.

58 GEOSCIENCES↗

Sensors with Intelligent Measurement Platform and Low-cost Equipment (SIMPLE) – Performance Characterization

Design and performance of a digital signal processing platform for enhancing off-the-shelf voltage and current sensors are presented. The platform was developed for enabling advanced distribution grid applications with existing low-cost sensors. This digital sensor system leverages a variety of off-the-shelf voltage and current sensing technologies, analog-to-digital conversion, and sensor correction algorithms to yield more accurate and reliable digital measurements that support a multitude of applications and use cases. Sample performance and accuracy results are provided, including measurements at power frequency and higher harmonics. The system extends the native performance of the medium voltage sensors used in the system, for example, broadening measurement bandwidth beyond a few kHz, appropriate for measuring switching surges and harmonics on medium voltage distribution systems. The digital sensor system is installed and characterized in the field with a high-bandwidth optical calibration system to determine site-dependent calibration and performance issues.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis: Preprint

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline- based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive- sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

grid following inverter↗

The Ponderomotive Effects of Narrow-band, Superconducting Resonators in Open and Closed Loop

In this work, we present measurements of ponderomotive instabilities in narrow-band, coaxial resonators in open and closed control loop systems. We show an analytical scheme we will use in future studies to examine the dependency of open loop stability on mechanical parameters. Analytical and simulation models are used to predict the onset of the oscillatory instability in half wave resonators with active disturbance rejection control for amplitude and phase stabilization. We demonstrate that for high amplitude controller bandwidths, ponderomotive oscillations can couple with the controller frequency response via higher harmonics and lower the threshold for the oscillatory instability. We reaffirm the superiority of in-phase/quadrature $(I/Q)$ component control in regards to preventing the oscillatory instability, and show how the phase controller can amplify the crosstalk of disturbances in amplitude and phase control. In cases with large disturbances, this effect can lead to instabilities not present in $I/Q$ control.

Brown, Jacob [Michigan State U.; Fermilab] (ORCID:↗

A method to test the coupling strength of the linear and nonlinear contributions to higher-order flow harmonics via event shape engineering

A Multi-Phase Transport (AMPT) model is used to study the efficacy of shape-engineered events to delineate the degree of coupling between the linear and nonlinear contributions to the higher-order flow harmonics v 4 and v 5 . Here, the study shows that the nonlinear contributions are strongly shape-dependent while the linear contributions are shape-independent, indicating little if any, coupling between the linear and nonlinear flow coefficients. The experimental verification of such patterns could be an invaluable tool for robust extraction of the linear and mode-coupled flow coefficients, especially for beam energies where the charged particle multiplicity and the event statistics precludes the use of current methods to establish the coupling strength.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Centrality and transverse-momentum dependence of higher-order flow harmonics of identified hadrons in Au+Au collisions at s N N = 200 GeV

Here we present high-precision measurements of elliptic, triangular, and quadrangular flow v 2 , v 3 , and v 4 , respectively, at midrapidity for identified hadrons π, p, K, φ, K s , Λ as a function of centrality and transverse momentum in Au+Au collisions at the center-of-mass energy √ s NN = 200 GeV. We observe similar v n trends between light and strange mesons which indicates that the heavier strange quarks flow as strongly as the lighter up and down quarks. The number-of-constituent-quark scaling for v 2 , v 3 , and v 4 is found to hold within statistical uncertainty for 0–10%, 10–40%, and 40–80% collision centrality intervals. The results are compared to several viscous hydrodynamic calculations with varying initial conditions, and could serve as an additional constraint to the development of hydrodynamic models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reduced fast-ion transport calculations of m = n = 1 fishbone-like instabilities in MAST-U

Fast-ion transport associated with an m = n = 1 fishbone-like burst in MAST-U discharge 47128 is investigated using a reduced guiding-center-based transport model (ORBIT-Kick) constrained by multi-diagnostic measurements. The two-dimensional beam-emission spectroscopy system provides measurements of the core poloidal mode structure and fluctuation amplitude, while EFIT++ reconstructions constrained by the motional Stark effect diagnostic indicate a flat q-profile with q 0 > 1⁠, indicating the absence of a resonant q = 1 surface and supporting a pressure-driven infernal-mode interpretation. Analytic m = n = 1 displacement profiles consistent with the measured core mode structure and equilibrium constraints are used as the mode structure inputs to ORBIT-Kick. The calculations show that the dominant resonances occur between the mode and co-passing fast ions, producing redistribution localized near the magnetic axis. Synthetic neutron camera signals from TRANSP-Kick recover up to 90% of the experimentally observed neutron deficit at the time of peak mode amplitude, indicating that the measured m = n = 1 mode is a dominant contributor to core fast-ion transport. However, the synthetic neutron signals recover rapidly, whereas the measured neutron emission continues to decrease after the peak amplitude. In conclusion, the remaining discrepancy may arise from contributions not included in the present single-harmonic model, including higher-m and higher-n harmonics, multi-harmonic interactions, and additional transport mechanisms, motivating future diagnostic development and modeling efforts to resolve and incorporate these additional contributions.

Wong, Henry H. [University of California, Los Ange↗

Harmonic cancellation within AC low voltage distribution for a realistic office environment

An increase of non-linear loads, primarily from power electronics, has substantially increased current harmonics in commercial buildings, which contributes to decreased transformer efficiency / lifespan and poor power quality. This study uses recorded power consumption data from common miscellaneous electric loads (MELs) seen in offices, combined with detailed characterizations of example MELs, to simulate harmonic cancellation within building circuits. Typically, harmonic cancellation studies assume that AC converters operate across their rated power range. However, this study finds that common MELs operate below 40% of rated power the majority of the time when not quiescent; 89% of sampled devices never operated above 60% of rated power. Simulations using these more realistic power levels indicate current-harmonic cancellation (3rd to 13th harmonic) is significantly lower than that predicted when using full-range power assumptions, resulting in minor errors for low-order harmonics and larger errors for higher order harmonics. Furthermore, increased MELs load diversity increases harmonic cancellation, but insufficiently to eliminate errors. In contrast, blending lighting loads with MELs on the secondaries of distribution transformers improves harmonic cancellation to near those predicted by traditional methods. These results indicate that realistic power levels, as well as better characterization of harmonics from typical MELs, should be used to estimate harmonic cancellation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Zero-Net-Rate Pumping Tests

Accurately estimating the distribution of aquifer properties is key to understanding contaminant movement in the subsurface. The distribution of aquifer properties is typically addressed using slug or constant-rate well tests, and the pros and cons of these tests are well known. Slug tests are appealing because they avoid removing contaminated water, but their results are affected by well skin and the small volume of displaced water limits the volume of aquifer that can be evaluated. Constant-rate well tests have the disadvantage of requiring disposal of potentially contaminated water, but they can generate properties that are more representative than slug tests, and they can be used to estimate well efficiency and storativity, which are difficult to characterize using slug tests. Periodic pumping tests are appealing because they have many of the advantages and few of the disadvantages of slug and constant-rate well tests. Periodic pumping tests involve cycling the pumping rate with a regular period and measuring the resulting response in monitoring wells. Some of these tests involve imposing a periodic rate on a constant mean rate. However, other tests involve moving water out and back into the well at rates that are balanced so the net rate after each period is zero. Some zero-net-rate (ZNR) well tests use rates that follow a sinusoidal pattern, whereas others use a square wave pattern that switches between a constant rate of pumping and a constant rate of injection to achieve a zero-net rate. ZNR well tests appear to be a useful compromise between slug and constant rate tests, but methods for conducting and analyzing the results from these tests have received limited evaluation. Periodic pumping tests are typically evaluated through recorded pressure responses to a disturbance source. Recent work has demonstrated that the strain field in the vadose zone shows a response to disturbances in the underlying aquifer. Various instrument designs are available that can record vertical and horizontal strain to very precise resolutions (10-9 ε). Measuring the strain in the vadose zone can present lower costs than measuring pressure in a monitoring well, so using strain could improve the resolution of ZNR tests, as well as make these tests potentially cheaper. A ZNR periodic pumping system was constructed and used to perform tests in the Clemson, South Carolina area. The system was designed to pump and inject with a periodic square-wave, so pumping occurs at a constant rate for half the period and is followed by injection at the same rate for half the period resulting in no net gain or loss of water from the aquifer. The system is designed to generate flow rates from 1 to 3.5 gallons per minute (gpm) with a capacity of 875-gallon per half period. Pressure and strain monitoring points are located in the vicinity of the pumping well. A series of 10 ZNR periodic pumping tests were conducted at the field site, with periods ranging from 2 to 540 minutes. Pressure data were collected and recorded in four monitoring wells in various locations around the pumping well. In addition, vertical and horizontal strain and tilt data were recorded in various locations around the pumping well. Traditional aquifer tests, including slug tests and constant-rate pumping tests were conducted at the field site to provide a baseline of aquifer parameter estimates that are compared the results of ZNR tests. Pressure data measured at monitoring wells during ZNR tests were analyzed utilizing an analytical solution (Streltsova, 1988) that assumes a confined aquifer and estimates hydraulic diffusivity and transmissivity using the time lag and amplitude of the pressure signal. The storativity can be separated out from the hydraulic diffusivity using the transmissivity estimate. The time-lag and amplitude of the pressure signals were estimated using a Fourier transform. The time-lag of the primary period of the pressure increases as a linear function of distance from the pumping well, and it increases as the square root of the period of the ZNR test over a range of periods spanning two orders of magnitudes. The first few harmonics follow similar trends, but the higher frequency harmonics diverge from this trend. Strain and tilt data from various instruments in the vadose and saturated zones are periodic during ZNR tests. The time lags of the strain components increase roughly linearly with distance from the well. Many of the time lags of the strain data from the vadose zone are similar to the time lags observed in the pressure data from a similar distance and pumping period. Theoretical experiments were performed to understand how pressure and strain responds to ZNR periodic pumping. The time-lags of the simulated pressure responses match the field data trends. The results were used to validate the Streltsova (1988) solution for periodic pumping to estimate hydraulic diffusivity. Hydraulic diffusivity was estimated to be 1.8 x 10-2 m2s-1 < Dh < 9.0 x 10-2 m2s-1 using pressure data from all the wells during ZNR tests. Transmissivity was estimated to be 0.8 x 10-4 m2s-1 < T < 4.3 x 10-4 m2s-1. Assuming Storativity = T/Dh gives 1.1 x 10-3 < S < 19 x10-3. Transmissivity is used to estimate the hydraulic conductivity, K, by dividing by the assumed aquifer thickness. Two constant-rate pumping tests were conducted and analyzed using two conceptual models: The Hantush (1961) solution was used to analyze data assuming confined conditions and the Neuman (1974) solution was used to analyze data assuming unconfined conditions. The Hantush (1961) solution estimated transmissivity to be 1.6 x 10-4 m2s-1 < T < 1.8 x 10-4 m2s-1 when using data from all the wells. Storativity was estimated to be 4.4 x 10-3 < S < 8.2 x 10-3. Assuming Dh = T/S gives 0.22 x 10-2 m2s-1 < Dh < 3.6 x 10-2 m2s-1. The Neuman (1974) solution estimated transmissivity to be 0.80 x 10-4 m2s-1 < T < 0.84 x 10-4 m2s-1. Total storativity (S + Sy) was estimated to be 22 x 10-3 < S < 110 x 10-3. Storativity excluding the Sy term was estimated to be 2.2 x 10-3 < S < 2.5 x 10-3. Assuming Dh = T/S gives 0.073 x 10-2 m2s-1 < S < 0.36 x 10-2 m2s-1. Two slug tests were performed on the pumping well, PW-2. The Bouwer and Rice (1976) solution for slug tests was used to analyze the data. This solution works for both confined and unconfined conditions, so both conceptual models were covered through the analysis. Hydraulic conductivity was estimated to be 1.95 x 10-6 ms-1 < K < 2.49 x 10-6 ms-1. Statistical comparison show generally no significant difference in the estimates of Dh, K, or S made using ZNR and conventional pumping tests.. However, the total storage estimated by the Neuman (1974) solution for unconfined settings is larger than that estimate using the Streltsove analysis applied to the ZNR tests. This is likely because the Neuman solution considers delayed yield from storage that the water table, whereas the Streltsova (1988) solution assumes confined conditions. The analysis also indicates that there is a statistically significant difference between parameters estimated with conventional slug tests and those measured with either constant-rate pumping tests or ZNR tests. Hydraulic diffusivity is estimated from the time-lag and the distance from the well. The time-lags of the strain data from the vadose zone are similar to the lags of the pressure data from a similar distance. This indicates that hydraulic diffusivities estimated from the strain data measured in the vadose zone would be similar to the estimates from the pressure data measured in the aquifer. There appear to be sign reversals in some of the strain data that were corrected to estimate the time lag. The dissolved oxygen (CO) concentration was measured during several ZNR tests to evaluate the feasibility of using the procedure to increase contaminant degradation kinetics that are related to DO. The results indicate that DO can be increased during the cycling of ZNR tests in some cases.

Smith-Jones, Austin↗

Dynamic pair-breaking current, critical superfluid velocity, and nonlinear electromagnetic response of nonequilibrium superconductors

Here, we report numerical calculations of a dynamic pair-breaking current density $J_d$ and a critical superfluid velocity $v_d$ in a nonequilibrium superconductor carrying a uniform, large-amplitude AC current density $J(t) = J_a$sinΩ$\textit{t}$ with Ω well below the gap frequency Ω $\ll Δ_0/ℏ$. The dependencies $J_d$(Ω, $\textit{T}$) and $v_d$(Ω, $\textit{T}$) near the critical temperature $T_c$ were calculated from either the full time-dependent nonequilibrium equations for a dirty $\textit{s}$-wave superconductor or the time-dependent Ginzburg-Landau (TDGL) equations for a gapped superconductor, taking into account the GL relaxation time of the order parameter $τ_{\text{GL}}$ and the inelastic electron-phonon relaxation time of quasiparticles $τ_E$. We show that both approaches give similar frequency dependencies of $J_d$(Ω) and $v_d$(Ω) which gradually increase from their static pair-breaking GL values $J_c$ and $v_c$ at Ω$τ_E \ll$1 to $\sqrt{2}J_c$ and $\sqrt{2}v_c$ at Ω$τ_E \gg$ 1. Here $J_d, v_d$ and a dynamic superheating field at which the Meissner state becomes unstable were calculated in two different regimes of a fixed AC current and a fixed AC superfluid velocity induced by the applied AC magnetic field $H = H_a$ sinΩ$\textit{t}$ in a thin superconducting filament or a type-II superconductor with a large GL parameter. We also calculated a nonlinear electromagnetic response of a nonequilibrium superconducting state, particularly a dynamic kinetic inductance and a dissipative quasiparticle conductivity, taking into account the oscillatory dynamics of superconducting condensate and the kinetics of quasiparticles driven by a strong AC current. It is shown that an AC current density produces multiple harmonics of the electric field, the amplitudes of the higher-order harmonics diminishing as $τ_E$ increases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Higher Order Multipole Analysis of Beam Crabbing Mode at 197 MHz for Electron-Ion Collider

In the local crabbing scheme for Electron Ion Collider interaction region, beam rotation is initiated by one set of crab cavities at a high beta region with near 90 deg phase advance to the interaction point (IP), and ceased by an identical set of cavities on the symmetrically opposite side. The fundamental mode of all crab cavities is designed to apply a momentum kick to the particle bunches to complete this half cycle of rotation in the horizontal plane, meanwhile the electromagnetic (EM) field can be expanded into a series of harmonics. Despite the lowest dipole mode, higher harmonics cause instabilities during beam operation and loss of particles. We used SimTrack, which is the 6-d symplectic element-by-element tracking code developed at Brookhaven National Laboratory in 2015, to study the threshold of each higher-order harmonic multipolar mode with the criteria of maintaining a dynamic aperture of 6 σ or greater for the Hadron Storage Ring (HSR). In this paper, we showed the threshold for each higher harmonic multipole and their comparison with the multipole strength for the current crab cavity design.

43 PARTICLE ACCELERATORS↗