Search NASA⌕ Search

SEARCH · Search NASA

Results for “image acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Applications of digital image acquisition in anthropometry

A description is given of a video kinesimeter, a device for the automatic real-time collection of kinematic and dynamic data. Based on the detection of a single bright spot by three TV cameras, the system provides automatic real-time recording of three-dimensional position and force data. It comprises three cameras, two incandescent lights, a voltage comparator circuit, a central control unit, and a mass storage device. The control unit determines the signal threshold for each camera before testing, sequences the lights, synchronizes and analyzes the scan voltages from the three cameras, digitizes force from a dynamometer, and codes the data for transmission to a floppy disk for recording. Two of the three cameras face each other along the 'X' axis; the third camera, which faces the center of the line between the first two, defines the 'Y' axis. An image from the 'Y' camera and either 'X' camera is necessary for determining the three-dimensional coordinates of the point.

Woolford, B.↗

Image Correlation Pattern Optimization for Micro-Scale In-Situ Strain Measurements

The accuracy and precision of digital image correlation (DIC) is a function of three primary ingredients: image acquisition, image analysis, and the subject of the image. Development of the first two (i.e. image acquisition techniques and image correlation algorithms) has led to widespread use of DIC; however, fewer developments have been focused on the third ingredient. Typically, subjects of DIC images are mechanical specimens with either a natural surface pattern or a pattern applied to the surface. Research in the area of DIC patterns has primarily been aimed at identifying which surface patterns are best suited for DIC, by comparing patterns to each other. Because the easiest and most widespread methods of applying patterns have a high degree of randomness associated with them (e.g., airbrush, spray paint, particle decoration, etc.), less effort has been spent on exact construction of ideal patterns. With the development of patterning techniques such as microstamping and lithography, patterns can be applied to a specimen pixel by pixel from a patterned image. In these cases, especially because the patterns are reused many times, an optimal pattern is sought such that error introduced into DIC from the pattern is minimized. DIC consists of tracking the motion of an array of nodes from a reference image to a deformed image. Every pixel in the images has an associated intensity (grayscale) value, with discretization depending on the bit depth of the image. Because individual pixel matching by intensity value yields a non-unique scale-dependent problem, subsets around each node are used for identification. A correlation criteria is used to find the best match of a particular subset of a reference image within a deformed image. The reader is referred to references for enumerations of typical correlation criteria. As illustrated by Schreier and Sutton and Lu and Cary systematic errors can be introduced by representing the underlying deformation with under-matched shape functions. An important implication, as discussed by Sutton et al., is that in the presence of highly localized deformations (e.g., crack fronts), error can be reduced by minimizing the subset size. In other words, smaller subsets allow the more accurate resolution of localized deformations. Contrarily, the choice of optimal subset size has been widely studied and a general consensus is that larger subsets with more information content are less prone to random error. Thus, an optimal subset size balances the systematic error from under matched deformations with random error from measurement noise. The alternative approach pursued in the current work is to choose a small subset size and optimize the information content within (i.e., optimizing an applied DIC pattern), rather than finding an optimal subset size. In the literature, many pattern quality metrics have been proposed, e.g., sum of square intensity gradient (SSSIG), mean subset fluctuation, gray level co-occurrence, autocorrelation-based metrics, and speckle-based metrics. The majority of these metrics were developed to quantify the quality of common pseudo-random patterns after they have been applied, and were not created with the intent of pattern generation. As such, it is found that none of the metrics examined in this study are fit to be the objective function of a pattern generation optimization. In some cases, such as with speckle-based metrics, application to pixel by pixel patterns is ill-conditioned and requires somewhat arbitrary extensions. In other cases, such as with the SSSIG, it is shown that trivial solutions exist for the optimum of the metric which are ill-suited for DIC (such as a checkerboard pattern). In the current work, a multi-metric optimization method is proposed whereby quality is viewed as a combination of individual quality metrics. Specifically, SSSIG and two auto-correlation metrics are used which have generally competitive objectives. Thus, each metric could be viewed as a constraint imposed upon the others, thereby precluding the achievement of their trivial solutions. In this way, optimization produces a pattern which balances the benefits of multiple quality metrics. The resulting pattern, along with randomly generated patterns, is subjected to numerical deformations and analyzed with DIC software. The optimal pattern is shown to outperform randomly generated patterns.

Bomarito, G. F.↗

Applying image processing methods to study hydrodynamic characteristics in a rectangular spouted bed

This paper presents systematic image processing methods for investigating hydrodynamic characteristics in a rectangular spouted bed (30.2 mm × 101.6 mm). The objective is to provide a non-intrusive technique to determine the bed expansion ratio, the jet height and the fountain height due to their significant influence on the hydrodynamics of the entire bed. A high-speed video camera is used in the experiment with Geldart D particles as the bed material. After the image acquisition, image denoising, thresholding, logical and mask operations are applied correspondingly for the boundary discrimination, based on which an algorithm has been developed to determine the bed height successfully. With the discriminated boundary, morphological operations viz. erosion and dilation have been used to accurately determine the jet height and the fountain height. The feasibility of the technique is proven through profiles of bed expansion ratio, jet height and fountain height under three initial bed heights (0.0762 m, 0.102 m, and 0.127 m) for two different nozzle sizes (0.0096 m and 0.0127 m). Depending on the determination of the hydrodynamic characteristics, different flow regimes can be distinguished comprehensively through profiles of the bed expansion ratio and bed pressure drop in combination with the standard deviation of jet/fountain height. The proposed flow regime discrimination verifies the feasibility and effectiveness of the image processing methods in assessing the solids behavior in the spouted beds. Results about the variation of the jet height and the fountain height under current operating conditions as determined by the new technique are also discussed.

20 FOSSIL-FUELED POWER PLANTS↗

A Framework for Patient-Centered Pathways of Care for Radiopharmaceutical Therapy: An ASTRO Consensus Document

Radiopharmaceutical therapy (RPT) is an area of projected growth and importance with several agents in clinical use, new agents in late-phase clinical trials, and many others under testing and development. This article proposes a framework for developing pathways of care that can be broadly applied to all RPTs, representing the current status of RPT. It suggests foundational elements for many pathways of care for patients with cancer and concludes with areas in active development and the future horizon for RPT treatment centers. Developing a framework for patient-centered pathways of care is a critical step in establishing RPT as standard therapy for patients with a diverse spectrum of cancers. This expected increase in RPT treatment options will affect a much larger population of patients with complex cancer. It will also require enhanced coordination and collaboration among appropriately qualified personnel with diverse expertise in image acquisition, image interpretation, quantitative imaging, dosimetry calculation, radiation quality assurance and safety as well as oncology care and RPT-induced sequelae and response assessment. The essential role of this evolving RPT care team within multidisciplinary oncology care is a cornerstone of this framework for a patient-centered pathway of care for RPT. Given the status of current RPT practice and the horizon for future applications, this patient-centered pathway of care guidance is timely and should help inform future clinical RPT practice paradigms. A task force was recruited from the Theranostic Working Group of the American Society for Radiation Oncology (ASTRO) in May 2019 with equal representation from the nuclear medicine community. The task force expanded on a framework that was originally conceived by the Working Group for patient-centered care. This framework was developed to incorporate the strengths of both radiation oncologists and nuclear medicine physicians. The manuscript was then developed by the task force and posted on the ASTRO website for a 6-week public comment period ending in July 2020. Comments were adjudicated, and the draft was sent to external organizations for potential endorsement. This document was sent to the ASTRO Board of Directors in October 2020 for approval.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The McIDAS system

The man-computer interactive data access system (McIDAS) hardware and software design is outlined, with emphasis on meteorological applications. The McIDAS system features a flexible digital image enhancement device. Theory of operation, the McIDAS language, the McIDAS executive monitor, image acquisition, image parameters, image display, graphics, image navigation, and image massaging are explained. The WINDCO/CLDHGT system, developed to align time sequences of geosynchronous satellite pictures and to determine the motion and height of selected cloud targets, is also described.

Smith, E. A.↗

A Low-Power High-Speed Smart Sensor Design for Space Exploration Missions

A low-power high-speed smart sensor system based on a large format active pixel sensor (APS) integrated with a programmable neural processor for space exploration missions is presented. The concept of building an advanced smart sensing system is demonstrated by a system-level microchip design that is composed with an APS sensor, a programmable neural processor, and an embedded microprocessor in a SOI CMOS technology. This ultra-fast smart sensor system-on-a-chip design mimics what is inherent in biological vision systems. Moreover, it is programmable and capable of performing ultra-fast machine vision processing in all levels such as image acquisition, image fusion, image analysis, scene interpretation, and control functions. The system provides about one tera-operation-per-second computing power which is a two order-of-magnitude increase over that of state-of-the-art microcomputers. Its high performance is due to massively parallel computing structures, high data throughput rates, fast learning capabilities, and advanced VLSI system-on-a-chip implementation.

Fang, Wai-Chi↗

Photon detection with parallel asynchronous processing

An approach to photon detection with a parallel asynchronous signal processor is described. The visible or IR photon-detection capability of the silicon p(+)-n-n(+) detectors and the parallel asynchronous processing are addressed separately. This approach would permit an independent analog processing channel to be dedicated to every pixel. A laminar architecture consisting of a stack of planar arrays of the devices would form a 2D array processor with a 2D array of inputs located directly behind a focal-plane detector array. A 2D image data stream would propagate in neuronlike asynchronous pulse-coded form through the laminar processor. Such systems can integrate image acquisition and image processing. Acquisition and processing would be performed concurrently as in natural vision systems. The possibility of multispectral image processing is addressed.

Coon, D. D.↗

Parallel asynchronous systems and image processing algorithms

A new hardware approach to implementation of image processing algorithms is described. The approach is based on silicon devices which would permit an independent analog processing channel to be dedicated to evey pixel. A laminar architecture consisting of a stack of planar arrays of the device would form a two-dimensional array processor with a 2-D array of inputs located directly behind a focal plane detector array. A 2-D image data stream would propagate in neuronlike asynchronous pulse coded form through the laminar processor. Such systems would integrate image acquisition and image processing. Acquisition and processing would be performed concurrently as in natural vision systems. The research is aimed at implementation of algorithms, such as the intensity dependent summation algorithm and pyramid processing structures, which are motivated by the operation of natural vision systems. Implementation of natural vision algorithms would benefit from the use of neuronlike information coding and the laminar, 2-D parallel, vision system type architecture. Besides providing a neural network framework for implementation of natural vision algorithms, a 2-D parallel approach could eliminate the serial bottleneck of conventional processing systems. Conversion to serial format would occur only after raw intensity data has been substantially processed. An interesting challenge arises from the fact that the mathematical formulation of natural vision algorithms does not specify the means of implementation, so that hardware implementation poses intriguing questions involving vision science.

Coon, D. D.↗

Mobility aid for the blind

A project to develop an effective mobility aid for blind pedestrians which acquires consecutive images of the scenes before a moving pedestrian, which locates and identifies the pedestrian's path and potential obstacles in the path, which presents path and obstacle information to the pedestrian, and which operates in real-time is discussed. The mobility aid has three principal components: an image acquisition system, an image interpretation system, and an information presentation system. The image acquisition system consists of a miniature, solid-state TV camera which transforms the scene before the blind pedestrian into an image which can be received by the image interpretation system. The image interpretation system is implemented on a microprocessor which has been programmed to execute real-time feature extraction and scene analysis algorithms for locating and identifying the pedestrian's path and potential obstacles. Identity and location information is presented to the pedestrian by means of tactile coding and machine-generated speech.

Source record↗

Fidelity Analysis of Sampled Imaging Systems

Many modeling, simulation and performance analysis studies of sampled imaging systems are inherently incomplete because they are conditioned on a discrete-input, discrete-output model that only accounts for blurring during image acquisition and additive noise. For those sampled imaging systems where the effects of digital image acquisition, digital filtering and reconstruction are significant, the modeling, simulation and performance analysis should be based on a more comprehensive continuous-input, discrete-processing, continuous-output end-to-end model. This more comprehensive model should properly account for the low-pass filtering effects of image acquisition prior to sampling, the potentially important noiselike effects of the aliasing caused by sampling, additive noise due to device electronics and quantization, the generally high-boost filtering effects of digital processing, and the low-pass filtering effects of image reconstruction. This model should not, however, be so complex as to preclude significant mathematical analysis, particularly the mean-square (fidelity) type of analysis so common in linear system theory. We demonstrate that, although the mathematics of such a model is more complex, the increase in complexity is not so great as to prevent a complete fidelity-metric analysis at both the component level and at the end-to-end system level: that is, computable mean-square-based fidelity metrics are developed by which both component-level and system-level performance can be quantified. In addition, we demonstrate that system performance can be assessed qualitatively by visualizing the output image as the sum of three component images, each of which relates to a corresponding fidelity metric. The cascaded, or filtered, component accounts for the end-to-end system filtering of image acquisition, digital processing, and image reconstruction; the random noise component accounts for additive random noise, modulated by digital processing and image reconstruction filtering; and the aliased noise component accounts for the frequency folding effect of sampling, modulated by digital processing and image reconstruction filtering.

Park, Stephen K.↗

SU-E-I-43: Pediatric CT Dose and Image Quality Optimization

Purpose: To design an approach to optimize radiation dose and image quality for pediatric CT imaging, and to evaluate expected performance. Methods: A methodology was designed to quantify relative image quality as a function of CT image acquisition parameters. Image contrast and image noise were used to indicate expected conspicuity of objects, and a wide-cone system was used to minimize scan time for motion avoidance. A decision framework was designed to select acquisition parameters as a weighted combination of image quality and dose. Phantom tests were used to acquire images at multiple techniques to demonstrate expected contrast, noise and dose. Anthropomorphic phantoms with contrast inserts were imaged on a 160mm CT system with tube voltage capabilities as low as 70kVp. Previously acquired clinical images were used in conjunction with simulation tools to emulate images at different tube voltages and currents to assess human observer preferences. Results: Examination of image contrast, noise, dose and tube/generator capabilities indicates a clinical task and object-size dependent optimization. Phantom experiments confirm that system modeling can be used to achieve the desired image quality and noise performance. Observer studies indicate that clinical utilization of this optimization requires a modified approach to achieve the desired performance. Conclusion: This work indicates the potential to optimize radiation dose and image quality for pediatric CT imaging. In addition, the methodology can be used in an automated parameter selection feature that can suggest techniques given a limited number of user inputs. G Stevens and R Singh are employees of GE Healthcare.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New field programmable gate array-based image-oriented acquisition and real-time processing applied to plasma facing component thermal monitoring

During operation of present fusion devices, the plasma facing components (PFCs) are exposed to high heat fluxes. Understanding and preventing overheating of these components during long pulse discharges is a crucial safety issue for future devices like ITER. Infrared digital cameras interfaced with complex optical systems have become a routine diagnostic to measure surface temperatures in many magnetic fusion devices. Due to the complexity of the observed scenes and the large amount of data produced, the use of high computational performance hardware for real-time image processing is then mandatory to avoid PFC damages. At Tore Supra, we have recently made a major upgrade of our real-time infrared image acquisition and processing board by the use of a new field programmable gate array (FPGA) optimized for image processing. This paper describes the new possibilities offered by this board in terms of image calibration and image interpretation (abnormal thermal events detection) compared to the previous system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗