Search NASA⌕ Search

SEARCH · Search NASA

Results for “image deconvolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

42 records · Page 3

Lens Model Accuracy in the Expected LSST Lensed AGN Sample

Strong gravitational lensing of active galactic nuclei (AGN) enables measurements of cosmological parameters through time-delay cosmography (TDC). With data from the upcoming LSST survey, we anticipate using a sample of O(1000) lensed AGN for TDC. To prepare for this dataset and enable this measurement, we construct and analyze a realistic mock sample of 1300 systems drawn from the OM10 (Oguri & Marshall 2010) catalog of simulated lenses with AGN sources at $z<3.1$ in order to test a key aspect of the analysis pipeline, that of the lens modeling. We realize the lenses as power law elliptical mass distributions and simulate 5-year LSST i-band coadd images. From every image, we infer the lens mass model parameters using neural posterior estimation (NPE). Focusing on the key model parameters, $θ_E$ (the Einstein Radius) and $γ_{lens}$ (the projected mass density profile slope), with consistent mass-light ellipticity correlations in test and training data, we recover $θ_E$ with less than 1% bias per lens, 6.5% precision per lens and $γ_{lens}$ with less than 3% bias per lens, 8% precision per lens. We find that lens light subtraction prior to modeling is only useful when applied to data sampled from the training prior. If emulated deconvolution is applied to the data prior to modeling, precision improves across all parameters by a factor of 2. Finally, we combine the inferred lens mass models using Bayesian Hierarchical Inference to recover the global properties of the lens sample with less than 1% bias.

Venkatraman, Padmavathi [Illinois U., Urbana; KIPA↗

RIFTA: A Robust Iterative Fourier Transform-based dwell time Algorithm for ultra-precision ion beam figuring of synchrotron mirrors

With the rapid evolution of synchrotron X-ray sources, the demand for high-precision X-ray mirrors has greatly increased. Single nanometer profile error is required to keep imaging capability at the diffraction limit. Ion Beam Figuring (IBF), as a highly deterministic surfacing technique, has been used for ultra-precision finishing of mirrors. One crucial step that guides the IBF process is dwell time calculation. A valid dwell time solution should be non-negative and duplicate the shape of the desired removal map. Another important aspect is to minimize the total dwell time. In this study, we propose a Robust Iterative Fourier Transform-based dwell time Algorithm (RIFTA) that automatically fulfills these requirements. First, the thresholded inverse filtering in Fourier transform-based deconvolution is stabilized and automated by optimizing the threshold value using the Nelder-Mead simplex algorithm. Second, a novel two-level iterative scheme is proposed to guarantee the minimized total dwell time with its non-negativity at each dwell point. Third, a bicubic resampling is employed to flexibly adapt the calculated dwell time map to any IBF process intervals. The performance of RIFTA is first studied with simulation, followed by a comparison with the other state-of-the-art dwell time algorithms. We then demonstrate with an experiment that, using the dwell time calculated by the RIFTA, the total dwell time is shortened by a factor of two and the RMS in a 5 × 50 mm clear aperture was reduced from 3.4 nm to 1.1 nm after one IBF run, which proves the effectiveness and the efficiency of the proposed algorithm.

42 ENGINEERING↗

Machine Learning Benchmarks for the Classification of Equivalent Circuit Models from Electrochemical Impedance Spectra

Analysis of Electrochemical Impedance Spectroscopy (EIS) data for electrochemical systems often consists of defining an Equivalent Circuit Model (ECM) using expert knowledge and then optimizing the model parameters to deconvolute various resistance, capacitive, inductive, or diffusion responses. For small data sets, this procedure can be conducted manually; however, it is not feasible to manually define a proper ECM for extensive data sets with a wide range of EIS responses. Automatic identification of an ECM would substantially accelerate the analysis of large sets of EIS data. We showcase machine learning methods to classify the ECMs of 9,300 impedance spectra provided by QuantumScape for the BatteryDEV hackathon. The best-performing approach is a gradient-boosted tree model utilizing a library to automatically generate features, followed by a random forest model using the raw spectral data. A convolutional neural network using boolean images of Nyquist representations is presented as an alternative, although it achieves a lower accuracy. We publish the data and open source the associated code. The approaches described in this article can serve as benchmarks for further studies. A key remaining challenge is the identifiability of the labels, underlined by the model performances and the comparison of misclassified spectra.

25 ENERGY STORAGE↗

Comparison between mirror Langmuir probe and gas-puff imaging measurements of intermittent fluctuations in the Alcator C-Mod scrape-off layer

Statistical properties of the scrape-off layer plasma fluctuations are studied in ohmically heated plasmas in the Alcator C-Mod tokamak. For the first time, plasma fluctuations as well as parameters that describe the fluctuations are compared across measurements from a mirror Langmuir probe (MLP) and from gas-puff imaging (GPI) that sample the same plasma discharge. This comparison is complemented by an analysis of line emission time-series data, synthesized from the MLP electron density and temperature measurements. The fluctuations observed by the MLP and GPI typically display relative fluctuation amplitudes of order unity together with positively skewed and flattened probability density functions. Such data time series are well described by an established stochastic framework that models the data as a superposition of uncorrelated, two-sided exponential pulses. The most important parameter of the process is the intermittency parameter, $γ=τ_d/τ_w$, where τd denotes the duration time of a single pulse and $τ_w$ gives the average waiting time between consecutive pulses. In this study we show, using a new deconvolution method, that these parameters can be consistently estimated from different statistics of the data. We also show that the statistical properties of the data sampled by the MLP and GPI diagnostic are very similar. Finally, a synthetic GPI signal using only plasma parameters sampled by the MLP shows qualitatively different fluctuation statistics from the measured GPI signal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fourier-based three-dimensional multistage transformer for aberration correction in multicellular specimens

High-resolution tissue imaging is often compromised by sample-induced optical aberrations that degrade resolution and contrast. Although wavefront sensor-based adaptive optics (AO) can measure these aberrations, such hardware solutions are typically complex, expensive to implement and slow when serially mapping spatially varying aberrations across large fields of view. Here we introduce AOViFT (adaptive optical vision Fourier transformer)—a machine learning-based aberration sensing framework built around a three-dimensional multistage vision transformer that operates on Fourier domain embeddings. AOViFT infers aberrations and restores diffraction-limited performance in puncta-labeled specimens with substantially reduced computational cost, training time and memory footprint compared to conventional architectures or real-space networks. We validated AOViFT on live gene-edited zebrafish embryos, demonstrating its ability to correct spatially varying aberrations using either a deformable mirror or postacquisition deconvolution. By eliminating the need for the guide star and wavefront sensing hardware and simplifying the experimental workflow, AOViFT lowers technical barriers for high-resolution volumetric microscopy across diverse biological samples.

Alshaabi, Thayer [Howard Hughes Medical Institute,↗

Radiation Mapping for an Unmanned Aerial Vehicle: Development and Simulated Testing of Algorithms for Source Mapping and Navigation Path Generation

Image reconstruction algorithms were developed for radiation source mapping and used for generating the search path of a moving radiation detector, such as one onboard an unmanned aerial vehicle. Simulations consisted of first assuming radioactive sources of varying complexity and estimating the radiation fields that would then be produced by that source distribution. Next, the "measurements" that would result from a pair of adjacent spatial locations were computed. A crude estimate of the source distribution likely to have produced such "measurements" was reconstructed based upon the limited measurements. Location of the next "measurement" was then determined as halfway between the location of the estimated source and the current "measurement." With each additional sample, improved source distribution reconstructions were made and used to inform the immediate direction of detector motion. Source reconstruction or mapping was formulated as an inverse problem solved with either maximum a posteriori or least squares (LS) regression deconvolution methods. Different amounts of noise were added to the simulated "measurements," allowing evaluation of the methods' performances as functions of signal-to-noise ratio of the measured map. As expected, methods that promote sparsity were better suited in reconstructing point sources. Reliable prior information of the source distribution also improved the reconstruction results, especially with distributed sources. With a non-negative least square algorithm and the suggested paths it generated, location of sources was successfully estimated to an accuracy of 0.014 m within nine iterations in a single-source scenario and 12 iterations in a two-source scenario, given a 10% error on the integrated counts and a Poisson distribution of the noise associated with the measured counts.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗