The Active Optics System on the Vera C. Rubin Observatory: Optimal Control of Degeneracy among the Large Number of Degrees of Freedom

Abstract The Vera C. Rubin Observatory is a unique facility for survey astronomy that will soon be commissioned and begin operations. Crucial to many of its scientific goals is the achievement of sustained high image quality, limited only by the seeing at the site. This will be maintained through an active optics system that controls optical element misalignments and corrects mirror figure error to minimize aberrations caused by both thermal and gravitational effects. However, the large number of adjustment degrees of freedom available on the Rubin Observatory introduces a range of degeneracies, including many that are induced by noise due to imperfect measurement of the wave-front errors. We present a structured methodology for identifying these degeneracies through an analysis of image noise level. We also present a novel scaling strategy based on truncated singular value decomposition that mitigates the degeneracy and optimally distributes the adjustment over the available degrees of freedom. Our approach ensures the attainment of optimal image quality, while avoiding excursions around the noise-induced subspace of degeneracies, marking a significant improvement over the previous techniques adopted for Rubin, which were based on an optimal integral controller. This new approach is likely to also yield significant benefits for all telescopes that incorporate large numbers of degrees of freedom of adjustment.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation Testing for High-Resolution Radiation-Hardened Camera System (Final CRADA Report)

The nuclear energy industry needs higher-image quality and higher rad-hard vision systems for refueling and inspection operations that are required every 12-18 months for all operating commercial reactors. During refueling operations, the serial numbers of fuel assemblies need to be visually verified in a challenging high radiation environment with dose rates on the order of 1kGy/hr. at the top of the core (approximately 10 days after shutdown). Vega Wave Systems has developed and built a radiation hard vision system that: 1. has high radiation hardness, 2. demonstrated best in the industry image quality, 3. has small size and weight, and 4. does not suffer from radiation-induced noise. ANL-1060 (02/13/2023) The proprietary Enduray vision system from Vega Wave Systems, Inc. is designed to withstand more than 400x the radiation level of the Vidicon-based systems, currently the highest radiation tolerant system in use today. The Van De Graaff (VDG) electron accelerator at Argonne National Laboratory is ideally suited for testing of Enduray vision system. VDG provides a broad band (up to 3 MeV) x-ray source that reasonably approximates the energy and spectrum of the gamma radiation expected at the top of a nuclear core 10 days after shutdown (~1kGy/hr.), is easily controlled for variable tests, and will not activate the parts under radiation for ease of timely and close inspection and characterization of the system in case of operational issues.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Associated Particle Imaging of Neutron Inelastic Scatter: 3-D Reconstruction, Capabilities, and Challenges

Associated particle imaging (API) offers unique advantages for 3-D imaging of neutron inelastic scatter, including single-view tomographic imaging and data acquisition when access is limited to only one side of the interrogated object. However, widespread adoption of neutron inelastic scatter imaging has been impeded by several inherent challenges, most prominently spatial resolution, self-attenuation, and statistical noise. Here, in this work, the capabilities and challenges of neutron inelastic scatter imaging are investigated. Instead of focusing on a single imaging application, we identify imaging principles that hold for various neutron inelastic scatter imaging techniques. The primary challenges for 3-D imaging are characterized. The inherent spatial resolution in the time-of-flight (TOF) dimension is derived based on the known system timing resolution and scan geometry. Three reconstruction algorithms are described and demonstrated, including the introduction of modern iterative reconstruction incorporating a physics-based system model. Simulation is leveraged to demonstrate imaging capability with varying coincidence count levels and system timing resolution. An example of measured data with both back-scatter and forward-scatter detector positioning is presented. System design characteristics and their effects on image quality are identified. The imaging framework presented in this article has the potential to facilitate growth of 3-D neutron inelastic scatter API by identifying applications that are a good match for the technique and by targeting system development resources toward the requirements of a specific imaging task.

Associated particle imaging (API)↗

Measuring Thickness-Dependent Relative Light Yield and Detection Efficiency of Scintillator Screens

Digital camera-based neutron imaging systems consisting of a neutron scintillator screen optically coupled to a digital camera are the most common digital neutron imaging system used in the neutron imaging community and are available at any state-of-the-art imaging facility world-wide. Neutron scintillator screens are the integral component of these imaging system that directly interacts with the neutron beam and dictates the neutron capture efficiency and image quality limitations of the imaging system. This work describes a novel approach for testing neutron scintillators that provides a simple and efficient way to measure relative light yield and detection efficiency over a range of scintillator thicknesses using a single scintillator screen and only a few radiographs. Additionally, two methods for correlating the screen thickness to the measured data were implemented and compared. An example 6LiF:ZnS scintillator screen with nominal thicknesses ranging from 0–300 μm was used to demonstrate this approach. The multi-thickness screen and image and data processing methods are not exclusive to neutron scintillator screens but could be applied to X-ray imaging as well. This approach has the potential to benefit the entire radiographic imaging community by offering an efficient path forward for manufacturers to develop higher-performance scintillators and for imaging facilities and service providers to determine the optimal screen parameters for their particular beam and imaging system.

42 ENGINEERING↗

Co-notch and independent windowing to mitigate interference in SAR-based imagery

Various technologies for mitigating distortion in coherent image products generated from SAR data are described herein. Synthetic aperture radar (SAR) datasets generated based upon SAR returns from first and second passes of a SAR platform over a scene are received. The SAR datasets can be co-notched at matching sample indices to improve coherence of SAR images generated from the datasets. Windowed SAR data is generated by applying independent windows to subsets of each of the datasets to reduce sidelobe levels of their image impulse responses. Coherent image products are generated based upon the windowed SAR data, wherein an image quality of the coherent image products is improved as compared to coherent image products generated based upon the SAR datasets.

47 OTHER INSTRUMENTATION↗

Imaging and dosimetric characteristics of 67 Cu

In recent years the use of beta-emitting radiopharmaceuticals for cancer therapy has expanded rapidly following development of therapeutics for neuroendocrine tumors, prostate cancer, and other oncologic malignancies. One emerging beta-emitting radioisotope of interest for therapy is 67 Cu (t 1/2 : 2.6 d) due to its chemical equivalency with the widely-established positron-emitting isotope 64 Cu (t 1/2 : 12.7 h). Here we evaluate both the imaging and dosimetric characteristics of 67 Cu, as well as producing the first report of SPECT/CT imaging using 67 Cu. To this end, 67 Cu was produced by photon-induced reactions on isotopically-enriched 68 Zn at the Low-Energy Accelerator Facility (LEAF) of Argonne National Laboratory, followed by bulk separation of metallic 68 Zn by sublimation and radiochemical purification by column chromatography. Gamma spectrometry was performed by efficiency-calibrated high-purity germanium (HPGe) analysis to verify absolute activity calibration and establish radionuclidic purity. Absolute activity measurements corroborated manufacturer-recommended dose-calibrator settings and no radionuclidic impurities were observed. Using the Clinical Trials Network anthropomorphic chest phantom, SPECT/CT images were acquired. Medium Energy (ME) SPECT collimation was found to provide the best image quality from the primary 185 keV gamma emission of 67 Cu. Reconstructed images of 67 Cu were similar in quality to images acquired using 177 Lu. Recovery coefficients were calculated and compared against quantitative images of 99m Tc, 177 Lu, and 64 Cu within the same anthropomorphic chest phantom. Production and clinical imaging of 67 Cu appears feasible, and future studies investigating the therapeutic efficacy of 67 Cu-based radiopharmaceuticals are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterizing natural fractures and sub-seismic faults for well completion of Marcellus shale in the MSEEL Consortium project, West Virginia, USA

The Middle Devonian Marcellus shale play has emerged as a major world-class hydrocarbon accumulation and represents one of the largest and most prolific shale plays in the world. According to many outcrop studies in the region, natural fractures are well developed in the Marcellus Shale. However, evaluating fractures in the subsurface is often a significant challenge due to a lack of sufficient data. Therefore, in the Marcellus Shale Energy and Environment Laboratory (MSEEL) consortium project, significant efforts have been made to acquire high-quality image logs in the Marcellus laterals. The project provided tremendous opportunities to characterize the natural fractures and sub-seismic faults and to evaluate their impact on well stimulation. In this study, about 70,000 ft of acquired high-resolution logging while drilling (LWD) acoustic images from five long laterals located in Monongalia County, West Virginia, were processed and interpreted. In addition, the study used high-quality micro-resistivity images from a pilot well, allowing the evaluation of natural fractures in the entire Marcellus vertical sequence. Based on the available acoustic images, the natural fractures were classified into three basic categories: high-amplitude fractures, low-amplitude fractures, and faults. Further, larger open fractures can also be determined when a low-amplitude fracture is evident on caliper images. The fractures in the Marcellus usually have a medium to high angle dip; however, multiple fracture sets in terms of strike orientation were clearly observed in all the laterals. The fracture set with a strike at NE-SW (or 60-240 deg) seems to be the predominant one in all the wells. A few other sets, including those with N-S, NWW-SEE, and E-W strikes, were also observed. Several sub-seismic faults, with mostly a low dip angle and a NE-SW strike, have also been seen in two of the laterals. The fracture density is variable across all the laterals, ranging from very low (or none) to very high (up to 5 fractures per ft). The average fracture density for all the laterals is about 1 fracture per 10 ft. In the vertical sequence, the natural fracture development showed a clear preference for shale or shaly facies over carbonate-rich or thin limestone layers. The interpreted fracture and fault data were used as input data for the stimulation design with the purpose of better understanding the fractures’ impact on well stimulation. Production data from the laterals were also used to evaluate the natural fractures’ influence on well performance. The quality image database and the consistent interpretation results for the entire project enabled a systematic approach to characterizing fractures and, more importantly, to evaluating the impact of fractures on well stimulation and production.

03 NATURAL GAS↗

Fidelity-preserving enhancement of ptychography with foundational text-to-image models

Ptychographic phase retrieval enables high-resolution imaging of complex samples but often suffers from artifacts such as grid pathology and multislice crosstalk, which degrade reconstructed images. We propose a plug-and-play (PnP) framework that integrates physics model-based phase retrieval with text-guided image editing using foundational diffusion models. By employing the alternating direction method of multipliers, our approach ensures consensus between data fidelity and artifact removal subproblems, maintaining physical consistency while enhancing image quality. Artifact removal is achieved using a text-guided diffusion image editing method (LEDITS++) with a pre-trained foundational diffusion model, allowing users to specify artifacts for removal in natural language. Demonstrations on simulated and experimental datasets show significant improvements in artifact suppression and structural fidelity, validated by metrics such as peak signal-to-noise ratio and diffraction pattern consistency. This work highlights the combination of text-guided generative models and model-based phase retrieval algorithms as a transferable and fidelity-preserving method for high-quality diffraction imaging.

image editing↗

Advancing X-ray quantum imaging through Monte-Carlo simulations

Imaging with X-rays poses fundamental limits due to radiation damage of the highly energetic photons. This becomes problematic for sensitive biological systems such as subcellular structures. Lowering the radiation dose, without sacrificing the signal-to-noise ratio, would be desirable for any kind of imaging modalities involving X-rays. To achieve this goal, quantum imaging with entangled X-ray photons constitutes a promising route. Production of biphotons have been demonstrated in the X-ray regime by the process of Spontaneous Parametric Down-Conversion (SPDC). However, compared to SPDC in the regime of visible light, the production rate for X-ray biphotons is extremely low. With the introduction of new high average brightness X-ray sources, such as 4th generation synchrotrons and high repetition rate Free-Electron X-ray Lasers (XFEL), quantum imaging may become practical. We introduce a ray tracing approach using Monte-Carlo sampling, specifically designed for quantum imaging with entangled X-ray photons generated by SPDC. By simulation, the superior image quality of quantum over classical imaging methods is demonstrated using realistic experimental conditions available at high repetition rate XFELs. With these simulations, we can efficiently assist the design of future experiments at beam lines, which can substantially accelerate the advancement of X-ray quantum imaging and reduce costs.

Entangled Photons↗

Monte Carlo N-Particle Transport Performance of Predicting Digital Radiographic IQI Inspection

The identification of porosity, geometric noncompliance, and other defect types are critical to the qualification of materials and components. X-ray radiographic nondestructive testing is a common industrial inspection method for process quality control and component qualification and certification. Digital radiography provides a quick and efficient alternative when compared to traditional film-based inspection. The quality of radiographic inspection is dependent on equipment specifications, such as the source spot size and detector pixel size, and the specific parameters selected for use for the radiographic technique. To evaluate if an x-ray system and technique is sufficient for a given requirement, a radiographic image quality indicator (IQI) can be used. Radiographic IQIs in hard to machine materials or hard to manufacture defects can be time consuming and expensive to manufacture. This study was conducted to evaluate current Savannah River National Laboratory (SRNL) x-ray imaging systems with a custom tantalum IQI and using Monte Carlo simulations to predict the performance of future systems. The tantalum IQI was tested using a Siefert Isovolt 420 keV x-ray tube with a Perkin Elmer XRD 1611 flat panel with 100-micron pixels. Using the Monte Carlo N-Particle transport software, the radiographic tally was used to simulate the photon flux through an identical tantalum IQI. These simulations provided a benchmark as to the best theoretical identification on a given system using our tantalum IQI. The simulations were refined to match SRNL’s current systems’ noise levels, leading to confidence in their ability to predict the performance of other systems that may be purchased and deployed in the future at the Savannah River Site. Future studies will be conducted to prove this research can be extended to artificially evaluate the ability for systems to identify critical defect sizes through x-ray radiographic inspection, drastically reducing the cost and time burdens of producing high-fidelity radiographic test articles.

digital X-ray radiography↗

A User-Friendly GUI Tool for Automated Microstructural Analysis of Fiber-Reinforced Composites and Porous Structures

Understanding and quantifying microstructural features such as fiber orientation and porosity is critical for predicting the mechanical behavior and performance of fiber-reinforced polymer composites. Traditional manual analysis is time-consuming, subjective, and unsuitable for high-throughput datasets. We present a graphical user interface (GUI) application that automates the analysis of microscopy images to extract key microstructural metrics, including fiber orientation tensors, fiber orientation distribution, porosity and pore size distribution. The app integrates multiple image segmentation techniques including global and local thresholding, clustering, and region-based approaches, offering flexibility for different types of image qualities and features. Users can load microstructural images, select regions of interest and segmentation techniques tailored to their image dataset. It also addresses a critical challenge in fiber orientation analysis: the ambiguities caused by touching, overlapping, or partially cut fibers. It supports autorun examples for standardized workflows, enabling reproducible analysis and facilitating training and benchmarking. This tool significantly reduces manual intervention, enhances consistency, and accelerates data generation for structure–property modeling, process optimization, and digital materials research. The tool is intended for use by materials scientists, engineers, and researchers engaged in composite characterization, quality control, and machine learning-based microstructural studies.

Chawla, Komal [ORNL] (ORCID:0000000190327565)↗

Fast digital lossy compression for X-ray ptychographic data

Increases in X-ray brightness from synchrotron light sources lead to a requirement for higher frame rates from hybrid pixel array detectors (HPADs), while also favoring charge integration over photon counting. However, transfer of the full uncompressed data will begin to constrain detector design, as well as limit the achievable continuous frame rate. Here a data compression scheme that is easy to implement in a HPAD's application-specific integrated circuit (ASIC) is described, and how different degrees of compression affect image quality in ptychography, a commonly employed coherent imaging method, is examined. Using adaptive encoding quantization, it is shown in simulations that one can digitize signals up to 16383 photons per pixel (corresponding to 14 bits of information) using only 8 or 9 bits for data transfer, with negligible effect on the reconstructed image.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DOLCE: A Model-Based Probabilistic Diffusion Framework for Limited-Angle CT Reconstruction

Limited-Angle Computed Tomography (LACT) is a non-destructive evaluation technique used in a variety of applications ranging from security to medicine. The limited angle coverage in LACT is often a dominant source of severe artifacts in the reconstructed images, making it a challenging inverse problem. We present DOLCE, a new deep model-based framework for LACT that uses a conditional diffusion model as an image prior. Diffusion models are a recent class of deep generative models that are relatively easy to train due to their implementation as image denoisers. DOLCE can form high-quality images from severely under-sampled data by integrating data-consistency updates with the sampling updates of a diffusion model, which is conditioned on the transformed limited-angle data. We show through extensive experimentation on several challenging real LACT datasets that, the same pre-trained DOLCE model achieves the SOTA performance on drastically different types of images. Additionally, we show that, unlike standard LACT reconstruction methods, DOLCE naturally enables the quantification of the reconstruction uncertainty by generating multiple samples consistent with the measured data.

Kim, Hyojin↗

FIRM: federated image reconstruction using multimodal tomographic data

Here, we propose a federated algorithm for reconstructing images using multimodal tomographic data sourced from dispersed locations, addressing the challenges of traditional unimodal approaches that are prone to noise and reduced image quality, as well as the limitations of centralized multimodal approaches that require extensive data transfer, leading to significant communication overhead, storage demands, and potential data privacy concerns. Our approach formulates a joint inverse optimization problem incorporating multimodality constraints and solves it in a federated framework through local gradient computations complemented by lightweight central operations, thereby ensuring data decentralization. Leveraging the connection between our federated algorithm and the quadratic penalty method, we introduce an adaptive step-size rule with guaranteed sublinear convergence. Numerical results demonstrate superior computational efficiency and improved image reconstruction quality compared to existing approaches.

federated algorithm↗

Performance of Kitt Peak’s Mayall 4-meter telescope during DESI commissioning

In preparation for the Dark Energy Spectroscopic Instrument (DESI), a new top end was installed on the Mayall 4-meter telescope at Kitt Peak National Observatory. The refurbished telescope and the DESI instrument were successfully commissioned on sky between 2019 October and 2020 March. Here we describe the pointing, tracking and imaging performance of the Mayall telescope equipped with its new DESI prime focus corrector, as measured by six guider cameras sampling the outer edge of DESI's focal plane. Analyzing ~500,000 guider images acquired during commissioning, we find a median delivered image FWHM of 1.1 arcseconds (in the r-band at 650 nm), with the distribution extending to a best-case value of ~0.6 arcseconds. The point spread function is well characterized by a Moffat profile with a power-law index of β ~ 3.5 and little dependence of β on FWHM. The shape and size of the PSF delivered by the new corrector at a field angle of 1.57 degrees are very similar to those measured with the old Mayall corrector on axis. Here, we also find that the Mayall achieves excellent pointing accuracy (several arcseconds RMS) and minimal open-loop tracking drift (< 1 milliarcsecond per second), improvements on the telecope's pre-DESI performance. In the future, employing DESI's active focus adjustment capabilities will likely further improve the Mayall/DESI delivered image quality.

47 OTHER INSTRUMENTATION↗

Combining Deep Learning and scatterControl for High-Throughput X-ray CT Based Non-Destructive Characterization of Large-Scale Casted Metallic Components

X-ray computed tomography (XCT) is essential for nondestructive evaluation and quality control of large-scale metal components. XCT imaging, however, faces significant challenges from metal artifacts, particularly those caused by Compton scattering, which degrade image quality and obscure critical details. Hardware-based solutions (e.g. scatterControl) offer advancements by intercepting scattered photons and reducing artifacts, but they can be time-consuming and require additional processing. Here, we propose modifying and leveraging a novel deep learning (DL) framework, Simurgh, to enhance and accelerate scatter correction in XCT. By combining scatterControl with DL-based artifact removal, we demonstrate significant reduction in scan time while producing high-quality reconstructions. Through extensive evaluation on industrial XCT data, we show that our methods reduce scan time by up to more than 10 x while preserving flaw detectability. Quantitative analysis across multiple segmentation techniques confirms that Simurgh-based reconstructions consistently outperform traditional Feldkamp-Davis-Kress, model-based iterative reconstruction, and commercial DL models in both pixel-level and task-specific evaluations, enabling scalable, high-throughput XCT workflows for characterization of large scale components in applications such as casting and metal additive manufacturing.

Complex metal parts↗