Search NASA⌕ Search

SEARCH · Search NASA

Results for “image system blur”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A discussion of image sharpness

The image sharpness problem is discussed in terms of a scene which is viewed by a sensor. The sensor has some sort of function which is a nonpoint observing function, and it's a function that gathers energy from some region around a point in the scene. That energy is integrated and is contributed to each point or each sample that is taken of the scene. The samples become the pixels, and the pixels are assembled together into the digital image. Each one has some blurr or some of what is called the point's spread function creating the value of information or data that is seen in each pixel. Then the sensor and electronic part of the system acts on that signal out of the sensor and perhaps adds more blurring, more loss of resolution to the system. Finally, sampling and quantization of the data produce their effects. The signal is sampled at some rate and the digital image is created from that. The sampling or digitizing process puts the continuous voltage into a number of discrete binary levels, and another error is introduced there.

Anuta, P.↗

The application of an optical Fourier spectrum analyzer on detecting defects in mass-produced satellite photographs

Various defects in mass-produced pictures transmitted to earth from a satellite are investigated. It is found that the following defects are readily detectable via Fourier spectrum analysis: (1) bit slip, (2) breakup causing loss of image, and (3) disabled track at the top of the imagery. The scratches made on the film during mass production, which are difficult to detect by visual observation, also show themselves readily in Fourier spectrum analysis. A relation is established between the number of scratches, their width and depth and the intensity of their Fourier spectra. Other defects that are found to be equally suitable for Fourier spectrum analysis or visual (image analysis) detection are synchronous loss without blurring of image, and density variation in gray scale. However, the Fourier spectrum analysis is found to be unsuitable for detection of such defects as pin holes, annotation error, synchronous loss with blurring of images, and missing image in the beginning of the work order. The design of an automated, real time system, which will reject defective films, is treated.

Athale, R.↗

Astronomy and astrophysics with the Advanced X-ray Astrophysics Facility

The optics and instruments of the Advanced X-ray Astrophysics Facility (AXAF) are described. The instrument capabilities are reviewed so that potential users of AXAF may plan supporting research in the years prior to launch. The AXAF is to be built around a large-area high-resolution grazing-incidence X-ray telescope, with a complement of imaging and spectroscopic instruments which can be maintained and/or replaced in orbit. An important feature of the AXAF is the aspect system. It utilizes solid state star cameras and fiducial lights to permit both image reconstruction (on the ground) with minimal blurring due to spacecraft and internal motions, and placement of the X-ray image on the sky to an accuracy of 1 arcsec.

Weisskopf, Martin C.↗

In-situ x-ray scatter imaging of battery electrodes

A method and apparatus for in-situ x-ray scatter imaging of battery electrodes. An apparatus includes an X-ray source, a grid, the grid comprising stainless steel wires with uniform spacing, and a cell, the X-ray source directing a beam of energy through the metal grid and components of the cell, the cell blurring a previously sharp projection of grid wires on an image detector. A method includes providing a Spatial Frequency Heterodyne Imaging system, providing a grid, providing a cell, generating X-rays from the Spatial Frequency Heterodyne Imaging system that pass through components of the cell and the grid, and detecting a scatter image from the X-rays.

Rose-Petruck, Christoph↗

Combined optimization of image-gathering and image-processing systems for scene feature detection

The relationship between the image gathering and image processing systems for minimum mean squared error estimation of scene characteristics is investigated. A stochastic optimization problem is formulated where the objective is to determine a spatial characteristic of the scene rather than a feature of the already blurred, sampled and noisy image data. An analytical solution for the optimal characteristic image processor is developed. The Wiener filter for the sampled image case is obtained as a special case, where the desired characteristic is scene restoration. Optimal edge detection is investigated using the Laplacian operator x G as the desired characteristic, where G is a two dimensional Gaussian distribution function. It is shown that the optimal edge detector compensates for the blurring introduced by the image gathering optics, and notably, that it is not circularly symmetric. The lack of circular symmetry is largely due to the geometric effects of the sampling lattice used in image acquisition. The optimal image gathering optical transfer function is also investigated and the results of a sensitivity analysis are shown.

Halyo, Nesim↗

Combined optimization of image-gathering optics and image-processing algorithm for edge detection

This paper investigates the relationships between the image-gathering and image-processing systems for minimum mean-squared error estimation of scene characteristics. A stochastic optimization problem is formulated in which the objective is to determine a spatial characteristic of the scene rather than a feature of the already blurred, sampled, and noisy image data. The Wiener filter for the sampled image case is obtained as a special case, where the desired characteristics is scene restoration. Optimal edge detection is investigated. It is shown that the optimal edge detector compensates for the blurring introduced by the image-gathering optics, and, notably, that it is not circularly symmetric. The lack of circular symmetry is largely due to the geometric effects of the sampling lattice used in image acquisition.

Halyo, N.↗

Infrared systems and components II; Proceedings of the Meeting, Los Angeles, CA, Jan. 14, 15, 1988

The present conference on the development status of IR electrooptics technologies discusses topics concerning such systems' materials and architectures, their modeling and data processing requirements, and advancements in IR automatic target recognition. Attention is given to active multispectral three-dimensional vision sensor image evaluation, a VHSIC processor-based real-time image tracker, the use of Al-alloy castings as diamond machining substrates for optical surfaces, a two-dimensional recognition range model, calculations of the optical blurring in IR systems, synthetic IR scene generation, and automatic target recognition evaluation.

Liaw, H. M.↗

Instrument for Achieving High Angular Resolution on the Infrared Telescope

Aberrations in stellar images caused by the atmosphere sets a significant limit on angular resolution in ground based astronomy. The largest of these aberrations is the image motion or wavefront tilt. Since the image motion is random it causes a blurring of the image, and this causes a blurring of the image from 0.3 arcseconds to about 0.7 arcseconds. The purpose of the tip-tilt project was to devise a system for the NASA Infrared Telescope Facility that would measure the image movement and correct it by rapidly tilting a mirror in two axes (tip and tilt). The system would involve building a CCD sensor package to measure the image motion, a new top end for the telescope to hold the tip-tilt mirror, a control system, and software. The system was designed to correct images for the facility camera, NSFCAM, and for the facility spectrometer, SPEX. Both of these instruments are equipped with a cold beamsplitter to feed the sensor package.

Hall, Donald N. B.↗

Aliasing and blurring in 2-D sampled imagery

The quality of image reconstructions from discrete data suffers not only from the blurring of spatial detail caused by limitations in the spatial frequency response of electrooptical systems, but also from the aliasing generated if spatial detail has been undersampled. Previous studies have observed that reasonable spot intensity profiles and photosensor aperture shapes of equivalent size result in about equal blurring but that some profiles and shapes suppress aliasing better than others. This paper presents quantitative results of the magnitude of aliasing and blurring as a function of random radiance fields typical for natural scenes and of spatial responses and sampling intervals typical for TV cameras and optical-mechanical scanners. These results indicate that aliasing may often be a larger source of degradation than either blurring or electronic noise.

Huck, F. O.↗

Initial Performance of the Aspect System on the Chandra Observatory: Post-Facto Aspect Reconstruction

The aspect system of the Chandra Observatory plays a key role in realizing the full potential of Chandra's x-ray optics and detectors. To achieve the highest spatial and spectral resolution (for grating observations), an accurate post-facto time history of the spacecraft attitude and internal alignment is needed. The CXC has developed a suite of tools which process sensor data from the aspect camera assembly and gyroscopes, and produce the spacecraft aspect solution. In this poster, the design of the aspect pipeline software is briefly described, followed by details of aspect system performance during the first eight months of flight. The two key metrics of aspect performance are: image reconstruction accuracy, which measures the x-ray image blurring introduced by aspect; and celestial location, which is the accuracy of detected source positions in absolute sky coordinates.

Aldcroft, T.↗

Validity and Reliability of Dynamic Visual Acuity (DVA) Measurement During Walking

DVA is primarily subserved by the vestibulo‐ocular reflex mechanism. Individuals with vestibular hypofunction commonly experience highly debilitating illusory movement or blurring of visual images during daily activities possibly, due to impaired DVA. Even without pathologies, gradual age‐related morphological deterioration is evident in all components of the vestibular system. We examined the construct validity to detect age‐related differences and test‐retest reliability of DVA measurements performed during walking. METHODS: Healthy adults were recruited into 3 groups: 1. young (20‐39years, n=18), 2. middle‐aged (40‐59years, n=14), and 3. older adults (60‐80years, n=15). Randomly selected seven participants from each group (n=21) participated in retesting. Participants were excluded if they had a history of vestibular or neuromuscular pathologies, dizziness/vertigo or >1 falls in the past year. Older persons with MMSE scores <29/30 were excluded to minimize cognitive errors. Participants' age, height, weight and normal walking speed were recorded. The binocular DVA was measured while walking on a treadmill at 0.8 m/s, 1.0 m/s and 1.2 m/s speeds. The walking speeds chosen represent a range of slow to moderate walking speeds for adult life span in participants who have no current mobility problems. The monitor that displayed Landolt 'C' optotypes was placed at 50 cm from the eyes for nearDVA (primary compensation by otolith organs) and at 3.0 m for farDVA (primary compensation by semicircular canals). A mixed factor ANOVA (age group x speed) was performed separately for the Near and FarDVA for detecting group differences. Intraclass correlation coefficients (ICCs) were calculated for each condition to determine test‐retest reliability. RESULTS: The three age groups were not different in their height, weight and normal walking speed (p>0.05). The post hoc analyses for DVA measurements demonstrated that each group was significantly different from the other two groups for Near as well as FarDVA (p<0.001‐p=0.031). The effect of speed was significant for both NearDVA (p=0.012) and FarDVA (p=0.014), however, there was no age group x speed interaction (FarDVA p=0.607, NearDVA p=0.343). The ICCs for Near and FarDVA ranged between 0.85‐ 0.88 and 0.71‐0.87, respectively. CONCLUSIONS: Differences in DVA between the three age groups were detected by using both Near and FarDVA protocols irrespective of the walking speed. Therefore, age group‐specific reference values should be used for detecting malfunction. Further, consistency in walking speed is critical for comparing between studies. NearDVA at all walking speeds and FarDVA at the speed of 1.2 m/s demonstrated excellent testretest reliability. FarDVA at 0.8 m/s and 1.0 m/s demonstrated good test‐retest reliability (ICCs 0.71 and 0.77, respectively).

Deshpande, Nandini↗

Dependence of Surface Contrast on Emission Angle in Cassini ISS 938-nm Images of Titan

Titan, the largest of Saturn s moons, is one of the most difficult solid surfaces in the Solar System to study. It is shrouded in a thick atmosphere with fine haze particles extending up to 500 km. [1] The atmosphere itself is rich in methane, which allows clear viewing of the surface only through narrow "windows" in the methane spectrum. Even in these methane windows, the haze absorbs and scatters light, blurring surface features and reducing the contrast of images. The haze optical depth is high at visible wavelengths, and decreases at longer (infrared) wavelengths. [2]

Fussner, S.↗

Optical-mechanical line-scan imaging process - Its information capacity and efficiency

Optical-mechanical line-scan techniques have been applied to earth satellite multispectral imaging systems. The capability of the imaging system is generally assessed by its information capacity. An approach based on information theory is developed to formulate the capacity of the line-scan process. Included are the effects of blurring of spatial detail, photosensor noise, aliasing, and quantization. The information efficiency is shown to be dependent on sampling rate, system frequency response shape, SNR, and quantization interval.

Huck, F. O.↗

Image tools for UNIX

This talk features two simple and useful tools for digital image processing in the UNIX environment. They are xv and pbmplus. The xv image viewer which runs under the X window system reads images in a number of different file formats and writes them out in different formats. The view area supports a pop-up control panel. The 'algorithms' menu lets you blur an image. The xv control panel also activates the color editor which displays the image's color map (if one exists). The xv image viewer is available through the internet. The pbmplus package is a set of tools designed to perform image processing from within a UNIX shell. The acronym 'pbm' stands for portable bit map. Like xv, the pbm plus tool can convert images from and to many different file formats. The source code and manual pages for pbmplus are also available through the internet. This software is in the public domain.

Banks, David C.↗

A Systems Approach to Estimating the Uncertainty Limits of X-Ray Radiographic Metrology

Micro- and nanomanufacturing capabilities have rapidly expanded over the past decade to include complex three-dimensional (3D) structure fabrication; however, the metrology required to accurately assess these processes via part inspection and characterization has struggled to keep pace. X-ray computed tomography (CT) is considered an ideal candidate for providing the critically needed metrology on the smallest scales, especially internal features, or inaccessible regions. X-ray CT supporting micro- and nanomanufacturing often push against the poorly understood resolution and variation limits inherent to the machines, which can distort or hide fine structures. In this study, we have developed and experimentally verify a comprehensive analytical uncertainty propagation signal variation flow graph (SVFG) model for X-ray radiography in this work to better understand resolution and image variability limits on the small scale. The SVFG approach captures, quantifies, and predicts variations occurring in the system that limit metrology capabilities, particularly in the micro/nanodomain. This work is the first step to achieving full uncertainty modeling of CT reconstructions and provides insight into improving X-ray attenuation imaging systems. The SVFG methodology framework is applied to generate a complete basis set of functions describing the major sources of variation in radiographs. Five models are identified, covering variation in energy, intensity, length, blur, and position. Radiographic system experiments are defined to measure the parameters required by the SVFGs. Best practices are identified for these measurements. The SVFG models are confirmed via direct measurement of variation to predict variation within 30% on average.

47 OTHER INSTRUMENTATION↗

Recent developments at JPL in the application of digital image processing techniques to astronomical images

Several techniques of a digital image-processing nature are illustrated which have proved useful in visual analysis of astronomical pictorial data. Processed digital scans of photographic plates of Stephans Quintet and NGC 4151 are used as examples to show how faint nebulosity is enhanced by high-pass filtering, how foreground stars are suppressed by linear interpolation, and how relative color differences between two images recorded on plates with different spectral sensitivities can be revealed by generating ratio images. Analyses are outlined which are intended to compensate partially for the blurring effects of the atmosphere on images of Stephans Quintet and to obtain more detailed information about Saturn's ring structure from low- and high-resolution scans of the planet and its ring system. The employment of a correlation picture to determine the tilt angle of an average spectral line in a low-quality spectrum is demonstrated for a section of the spectrum of Uranus.

Lorre, J. J.↗

Review of High‐Speed Digital Image Correlation: Advancements and Good Practices

This paper reviews the current state of the art in high‐speed (HS) and ultrahigh‐speed (UHS) digital image correlation (DIC) techniques, emphasizing their critical role in experimental research across various scientific domains. HS and UHS DIC have evolved significantly, driven by advancements in camera systems, image processing algorithms and experimental methodologies. These developments have opened new avenues for capturing and analysing dynamic events with unprecedented temporal and spatial detail, but not without introducing challenges such as optical distortions, motion blur and lighting issues that can affect measurement quality. This review advocates for standardized reporting practices in HS/UHS DIC methodologies to improve reproducibility and reliability across studies, drawing on guidelines from the International Digital Image Correlation Society (iDICs). Through a comprehensive analysis of over 150 articles, this review identifies key advancements in imaging technology and their application in six research domains: material characterization, test development, fracture mechanics, model validation, ballistic and explosive phenomena assessment and measurement uncertainties. Distinctions between two‐dimensional (2D) and stereo‐DIC applications are explored, offering insights into their practical implementation and trade‐offs. Good practices for HS/UHS DIC applications are proposed along with suggestions for future directions for this evolving field, highlighting the indispensable role of technological innovation in expanding the capabilities of optical metrology.

experimental mechanics↗

Grayscale/resolution trade-off for text: Model predictions and psychophysical results for letter confusion and letter discrimination

In a series of papers presented in 1994, we examined the grayscale/resolution trade-off for natural images displayed on devices with discrete pixellation, such as AMLCD's. In the present paper we extend this study by examining the grayscale/resolution trade-off for text images on discrete-pixel displays. Halftoning in printing is an example of the grayscale/resolution trade-off. In printing, spatial resolution is sacrificed to produce grayscale. Another example of this trade-off is the inherent low-pass spatial filter of a CRT, caused by the point-spread function of the electron beam in the phosphor layer. On a CRT, sharp image edges are blurred by this inherent low-pass filtering, and the block noise created by spatial quantization is greatly reduced. A third example of this trade-off is text anti-aliasing, where grayscale is used to improve letter shape, size and location when rendered at a low spatial resolution. There are additional implications for display system design from the grayscale/resolution trade-off. For example, reduced grayscale can reduce system costs by requiring less complexity in the framestore, allowing the use of lower cost drivers, potentially increasing data transfer rates in the image subsystem, and simplifying the manufacturing processes that are used to construct the active matrix for AMLCD (active-matrix liquid-crystal display) or AMTFEL (active-matrix thin-film electroluminescent) devices. Therefore, the study of these trade-offs is important for display designers and manufacturing and systems engineers who wish to create the highest performance, lowest cost device possible. Our strategy for investigating this trade-off is to generate a set of simple test images, manipulate grayscale and resolution, predict discrimination performance using the ViDEOS(Sarnoff) Human Vision Model, conduct an empirical study of discrimination using psychophysical procedures, and verify the computational results using the psychophysical results.

Gille, Jennifer↗