Search NASA⌕ Search

SEARCH · Search NASA

Results for “impedance of transformers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Simulation of Sound Absorption by Scattering Bodies Treated with Acoustic Liners Using a Time-Domain Boundary Element Method

Reducing aircraft noise is a major objective in the field of computational aeroacoustics. When designing next generation quiet aircraft, it is important to be able to accurately and efficiently predict the acoustic scattering by an aircraft body from a given noise source. Acoustic liners are an effective tool for aircraft noise reduction, and are characterized by a complex valued frequency-dependent impedance, Z(w). Converted into the time-domain using Fourier transforms, an impedance boundary condition can be used to simulate the acoustic wave scattering of geometric bodies treated with acoustic liners. This work uses an admittance boundary condition where the admittance, Y(w), is defined to be the inverse of impedance, i.e., Y(w) = 1/Z(w). An admittance boundary condition will be derived and coupled with a time domain boundary integral equation. The solution will be obtained iteratively using spatial and temporal basis functions and will allow for acoustic scattering problems to be modeled with geometries consisting of both unlined and soft surfaces. Stability will be demonstrated through eigenvalue analysis.

Pizzo, Michelle E.↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Load dynamics of double planar foil liners and double planar wire arrays on the UM MAIZE LTD generator

In previous studies using the University of Nevada, Reno's (UNR's) high-impedance Zebra Marx generator (1.9 Ω, 1.7 MA, 100 ns), Double Planar Wire Arrays (DPWAs) proved to be excellent radiators, and Double Planar Foil Liners (DPFLs) proved useful for future inertial confinement fusion applications. This article presents the results of joint UNR/UM (University of Michigan) experiments with aluminum (Al) DPWAs, Al DPFLs, and tungsten (W) DPWAs using UM's Michigan Accelerator for Inductive Z-Pinch Experiments (MAIZE) generator, a low-impedance Linear Transformer Driver (LTD) (0.1 Ω, 0.5–1 MA, and 100–250 ns). The main goals of this study were twofold: the first was a pioneering effort to test whether a relatively heavy Al DPFL could successfully be imploded on a low-impedance university-scale LTD like the MAIZE generator, and, if so, to analyze the results and make comparisons to the optimized, lighter DPWA configurations that have been previously studied. The DPWAs consisted of two planes of micrometer-scale diameter Al or W wires, while the DPFLs consisted of two planes of micrometer-scale thickness Al foils. Diagnostics include filtered Si-diodes, an absolutely calibrated filtered PCD, x-ray pinhole cameras, spectrometers, and gated optical self-emission imaging. The implosion dynamics and radiative properties of Al DPWAs and DPFLs and W DPWAs on the MAIZE LTD are discussed and compared. Time-dependent load inductance calculations derived from measurements of the load current and a MAIZE circuit model provide a relative measurement of pinch strength. In experiments on MAIZE, W planar wire arrays exhibited a higher peak load inductance throughout the pinch than Al DPWAs and DPFLs, while x-ray pulses from Al DPFLs had the longest emission duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synthesis of LiNiO 2 at Moderate Oxygen Pressure and Long-Term Cyclability in Lithium-Ion Full Cells

The widespread adoption of electric vehicles necessitates higher-energy-density and longer-life cathode materials for Li-ion batteries. LiNiO 2 offers a higher energy density at a lower cost than other high-Ni-content cathodes containing additional transition-metal ions. However, detrimental phase transformations and impedance growth, resulting from structural defects formed during synthesis, lead to poor cyclability and limit the practical viability of LiNiO 2 . Herein, we demonstrate a considerably improved cycle life for LiNiO 2 by synthesizing it under a pressurized oxygen environment. The capacity retention in pouch-type full cells with a graphite anode after 1000 cycles is increased from 59 to 76% by applying a mere 1.7 atm of oxygen pressure during the synthesis of LiNiO 2 . With iodometric titration and inductively coupled plasma optical emission spectroscopy analysis, we provide clear evidence that oxygen pressure during synthesis reduces the occurrence of lattice oxygen vacancies and increases the content of Ni 3+ in LiNiO 2 , improving its structural integrity and cyclability. Post-mortem analysis of the cycled cathodes provides insights into the sources of degradation occurring during long-term cycling. Here, this work demonstrates a practically viable, synthetic approach combined with doping and coating to achieve improved performance with high-Ni layered oxide materials. Furthermore, this work represents the first report of extended cycling of LiNiO 2 in pouch full cells with graphite anode and will, therefore, serves as an important benchmark for future research on LiNiO 2 .

25 ENERGY STORAGE↗

Pulse transformer for GaAs laser

High-radiance gallium arsenide (GaAs) laser operating at room temperature is utilized in optical navigation system. For efficient transformer-to-laser impedance match, laser should be connected directly to pulse transformer secondary winding.

Rutz, E. M.↗

Transformer system

A flexible transformer system includes conductive windings extending around a magnetic core of a transformer phase and impedance-varying windings extending around the magnetic core of the transformer phase. The conductive windings and the impedance-varying windings are configured to conduct electric current around the magnetic core of the transformer phase. The system includes an impedance switch coupled with the impedance-varying windings and with the conductive windings. The impedance switch is configured to change an impedance of the system by changing which impedance-varying winding of the impedance-varying windings is conductively coupled with the conductive windings and which impedance-varying winding of the impedance-varying windings is disconnected from the conductive windings.

Premerlani, William James↗

New data-driven approach to bridging power system protection gaps with deep learning

Protection is a critical function in power systems to avoid equipment damage, maintain personnel safety, and support system reliability. However, current protective relay technology cannot adequately protect equipment and personnel from effects of some events; these deficiencies are termed protection gaps. In this paper, a data-driven approach is proposed to complement traditional protection technology and distinguish fault conditions from transients caused by normal operations. A combined convolutional neural network and long short-term memory (CNN-LSTM) network is implemented to achieve data translation invariance and capture the temporal correlation of the time-series input data. As a result, the data-driven method can accurately detect system faults despite variation and noise in the input data. In addition, using the CNN-LSTM--based method avoids the complicated, manual feature extraction procedure required by many traditional data-driven methods. The effectiveness of the proposed approach is tested on two kinds of protection gaps: high-impedance faults and transformer inter-turn faults. Lastly, a transfer learning method is also proposed to address the common issue of data-driven methods for which real-world training data are scarce. Extensive study results demonstrate that the proposed approach can accurately bridge power system protection gaps.

42 ENGINEERING↗

Equations For Rotary Transformers

Equations derived for input impedance, input power, and ratio of secondary current to primary current of rotary transformer. Used for quick analysis of transformer designs. Circuit model commonly used in textbooks on theory of ac circuits.

Salomon, Phil M.↗

Advanced infrared laser modulator development

A parametric study was conducted to develop an electrooptic waveguide modulator for generating continuous tunable sideband power from an infrared CO2 laser. Parameters included were the waveguide configurations, microstrip dimensions device impedance, and effective dielectric constants. An optimum infrared laser modulator was established and was fabricated. This modulator represents the state-of-the-art integrated optical device, which has a three-dimensional topology to accommodate three lambda/4 step transformers for microwave impedance matching at both the input and output terminals. A flat frequency response of the device over 20 HGz or = 3 dB) was achieved. Maximum single sideband to carrier power greater than 1.2% for 20 W microwave input power at optical carrier wavelength of 10.6 microns was obtained.

Cheo, P. K.↗

Effect of Thrustor Arcing on Ion Rocket System Design

Arcing between the electrodes of an ion rocket thrustor is investigated for the effect it will have on the overall design of ion rocket systems. The effect of generator, transformer, and inserted impedances on system stability and efficiency, and on operating lifetime of thrustor components are considered. Rate of arcing, preferential arc paths, speed of arc interruption, and response of thrustors to voltage transients are also discussed. The study indicates that arcing is a system hazard and that arcing rates are of prime importance in the design and development of thrustors, thrustor arrays, and system components. Two system models for reducing the hazard are proposed, based on principles developed herein, published data, and experience available from operation of nine-module electron-bombardment thrustor array. Experimental investigation of these models is presently underway.

THRUSTOR↗

Testing Fixture For Microwave Integrated Circuits

Testing fixture facilitates radio-frequency characterization of microwave and millimeter-wave integrated circuits. Includes base onto which two cosine-tapered ridge waveguide-to-microstrip transitions fastened. Length and profile of taper determined analytically to provide maximum bandwidth and minimum insertion loss. Each cosine taper provides transformation from high impedance of waveguide to characteristic impedance of microstrip. Used in conjunction with automatic network analyzer to provide user with deembedded scattering parameters of device under test. Operates from 26.5 to 40.0 GHz, but operation extends to much higher frequencies.

Romanofsky, Robert↗

Challenges Associated with In-Situ Calibration of Load Cells in Force Limited Vibration Testing

The difference in mounting configuration between flight and test can significantly impact the effectiveness of the test in environmental vibration testing. Many tests are performed with large electrodynamic shakers, which utilize interfaces that seek to replicate a fixed base, such as slip tables and head expanders. This fixed base configuration is rarely seen in flight configurations; rather a more realistic configuration would include a flexible mounting structure with its own compliance and dynamics. This causes significant over and under tests in various frequency bands depending on the differences between the test article and fixture dynamics. The traditional way of avoiding these high loads is to limit the acceleration responses at multiple locations on the test article. However, the effectiveness of this approach is highly dependent upon the validity of the test article’s analytical in order to derive accurate acceleration response limit specifications. Also this technique requires limiting the acceleration responses at many locations throughout the test article, which may not be implementable due to such things as access and cleanliness issues An improved environmental vibration testing technique known as force limiting incorporates measurements of the forces between the test article and shaker system interface and limiting them to a specification that more accurately replicates the interface impedance of the structure the test article will be mounted to in flight. In effect this transforms the high mechanical impedance at the test article to shaker interface to more closely match the mechanical impedance of the flight interface, which avoids producing the unrealistically high interface loads. Typically force gauges or load cells are used to measure these interface forces. However, utilizing load cells can present a multitude of challenges depending upon such things as their installation method, geometric layout, and test fixture setup. Regardless, it is extremely important to perform an in-situ calibration of the load cells prior to vibration testing at any significant levels. This paper will discuss the challenges associated with utilizing load cells during the NASA Evolutionary Xenon Thruster – Commercial (NEXT-C) gridded ion thruster proto-flight vibration test performed at the NASA Glenn Research Center’s Structural Dynamics Laboratory.

Kenneth J Pederson↗

Challenges Associated with In-Situ Calibration of Load Cells in Force Limited Vibration Testing

The difference in mounting configuration between flight and test can significantly impact the effectiveness of the test in environmental vibration testing. Many tests are performed with large electrodynamic shakers, which utilize interfaces that seek to replicate a fixed base, such as slip tables and head expanders. This fixed base configuration is rarely seen in flight configurations; rather a more realistic configuration would include a flexible mounting structure with its own compliance and dynamics. This causes significant over and under tests in various frequency bands depending on the differences between the test article and fixture dynamics. The traditional way of avoiding these high loads is to limit the acceleration responses at multiple locations on the test article. However, the effectiveness of this approach is highly dependent upon the validity of the test article’s analytical in order to derive accurate acceleration response limit specifications. Also this technique requires limiting the acceleration responses at many locations throughout the test article, which may not be implementable due to such things as access and cleanliness issues An improved environmental vibration testing technique known as force limiting incorporates measurements of the forces between the test article and shaker system interface and limiting them to a specification that more accurately replicates the interface impedance of the structure the test article will be mounted to in flight. In effect this transforms the high mechanical impedance at the test article to shaker interface to more closely match the mechanical impedance of the flight interface, which avoids producing the unrealistically high interface loads. Typically force gauges or load cells are used to measure these interface forces. However, utilizing load cells can present a multitude of challenges depending upon such things as their installation method, geometric layout, and test fixture setup. Regardless, it is extremely important to perform an in-situ calibration of the load cells prior to vibration testing at any significant levels. This paper will discuss the challenges associated with utilizing load cells during the NASA Evolutionary Xenon Thruster – Commercial (NEXT-C) gridded ion thruster proto-flight vibration test performed at the NASA Glenn Research Center’s Structural Dynamics Laboratory.

K. J. Pederson↗

Grid-Ready Flexible Transformers for Resilient Transmission Networks

Today’s transmission networks extend for hundreds of kilometers, transferring significant amounts of electrical energy. For every country, there are sort of “back- bone” lines, where a massive failure of transformers would create serious challenges to sustain a reliable energy supply. Natural phenomena and human driven actions could be triggers of such catastrophic events. For large utilities, or groups of utilities, it would be highly convenient to count with “flexible transformers”, which could be used as replacements for different voltage levels and with impedance adjustable to match optimum local requirements of impacted substations. Currently applied “emergency transformers” are fixed-impedance devices. In this contribution, a new concept of flexible, “future-grid ready” type of power transformers, specially devised for transmission networks is explained. This transformer has adjustable impedance features, which could be on-line operated. The concept has been proven to be functional and stable in the factory lab and in the field, by means of a prototype autotransformer of of 100 MVA, 165/69 Kv.

impedance of transformers↗

Flexible Transformers for Resilient and Adaptable Power Systems

This paper presents experience with grid ready flexible transformer unit, which is in service for two years without any difficulty. Transformer unit is capable of changing short circuit impedance on load and it is equipped with state-of-the-art monitoring system.

field validation↗

Approximating accelerator impedances with resonator networks

It is common in the accelerator community to use the impedance of accelerator components to describe wake interactions in the frequency domain. However, it is often desirable to understand such wake interactions in the time domain in a general manner for excitations that are not necessarily Gaussian in nature. Here, the conventional method for doing this involves taking the inverse Fourier Transform of the component impedance, obtaining the Green's Function, and then convolving it with the desired excitation distribution. This method can prove numerically cumbersome, for a convolution integral must be evaluated for each individual point in time when the wake function is desired. An alternative to this method would be to compute the wake function analytically, which would sidestep the need for repetitive integration. Only a handful of cases, however, are simple enough for this method to be tenable. One of these cases is the case where the component in question is an RLC resonator, which has a closed-form analytical wake function solution. This means that a component which can be represented in terms of resonators can leverage this solution. As it happens, common network synthesis techniques may be used to map arbitrary impedance profiles to RLC resonator networks in a manner the accelerator community has yet to take advantage of. In this work, we will use Foster Canonical Resonator Networks and partial derivative descent optimization to develop a technique for synthesizing resonator networks that well approximate the impedances of real-world accelerator components. We will link this synthesis to the closed-form resonator wake function solution, giving rise to a powerful workflow that may be used to streamline beam dynamics simulations.

43 PARTICLE ACCELERATORS↗