Search NASA⌕ Search

SEARCH · Search NASA

Results for “impedance of transformers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Testing Fixture For Microwave Integrated Circuits

Testing fixture facilitates radio-frequency characterization of microwave and millimeter-wave integrated circuits. Includes base onto which two cosine-tapered ridge waveguide-to-microstrip transitions fastened. Length and profile of taper determined analytically to provide maximum bandwidth and minimum insertion loss. Each cosine taper provides transformation from high impedance of waveguide to characteristic impedance of microstrip. Used in conjunction with automatic network analyzer to provide user with deembedded scattering parameters of device under test. Operates from 26.5 to 40.0 GHz, but operation extends to much higher frequencies.

Romanofsky, Robert↗

Challenges Associated with In-Situ Calibration of Load Cells in Force Limited Vibration Testing

The difference in mounting configuration between flight and test can significantly impact the effectiveness of the test in environmental vibration testing. Many tests are performed with large electrodynamic shakers, which utilize interfaces that seek to replicate a fixed base, such as slip tables and head expanders. This fixed base configuration is rarely seen in flight configurations; rather a more realistic configuration would include a flexible mounting structure with its own compliance and dynamics. This causes significant over and under tests in various frequency bands depending on the differences between the test article and fixture dynamics. The traditional way of avoiding these high loads is to limit the acceleration responses at multiple locations on the test article. However, the effectiveness of this approach is highly dependent upon the validity of the test article’s analytical in order to derive accurate acceleration response limit specifications. Also this technique requires limiting the acceleration responses at many locations throughout the test article, which may not be implementable due to such things as access and cleanliness issues An improved environmental vibration testing technique known as force limiting incorporates measurements of the forces between the test article and shaker system interface and limiting them to a specification that more accurately replicates the interface impedance of the structure the test article will be mounted to in flight. In effect this transforms the high mechanical impedance at the test article to shaker interface to more closely match the mechanical impedance of the flight interface, which avoids producing the unrealistically high interface loads. Typically force gauges or load cells are used to measure these interface forces. However, utilizing load cells can present a multitude of challenges depending upon such things as their installation method, geometric layout, and test fixture setup. Regardless, it is extremely important to perform an in-situ calibration of the load cells prior to vibration testing at any significant levels. This paper will discuss the challenges associated with utilizing load cells during the NASA Evolutionary Xenon Thruster – Commercial (NEXT-C) gridded ion thruster proto-flight vibration test performed at the NASA Glenn Research Center’s Structural Dynamics Laboratory.

Kenneth J Pederson↗

Challenges Associated with In-Situ Calibration of Load Cells in Force Limited Vibration Testing

The difference in mounting configuration between flight and test can significantly impact the effectiveness of the test in environmental vibration testing. Many tests are performed with large electrodynamic shakers, which utilize interfaces that seek to replicate a fixed base, such as slip tables and head expanders. This fixed base configuration is rarely seen in flight configurations; rather a more realistic configuration would include a flexible mounting structure with its own compliance and dynamics. This causes significant over and under tests in various frequency bands depending on the differences between the test article and fixture dynamics. The traditional way of avoiding these high loads is to limit the acceleration responses at multiple locations on the test article. However, the effectiveness of this approach is highly dependent upon the validity of the test article’s analytical in order to derive accurate acceleration response limit specifications. Also this technique requires limiting the acceleration responses at many locations throughout the test article, which may not be implementable due to such things as access and cleanliness issues An improved environmental vibration testing technique known as force limiting incorporates measurements of the forces between the test article and shaker system interface and limiting them to a specification that more accurately replicates the interface impedance of the structure the test article will be mounted to in flight. In effect this transforms the high mechanical impedance at the test article to shaker interface to more closely match the mechanical impedance of the flight interface, which avoids producing the unrealistically high interface loads. Typically force gauges or load cells are used to measure these interface forces. However, utilizing load cells can present a multitude of challenges depending upon such things as their installation method, geometric layout, and test fixture setup. Regardless, it is extremely important to perform an in-situ calibration of the load cells prior to vibration testing at any significant levels. This paper will discuss the challenges associated with utilizing load cells during the NASA Evolutionary Xenon Thruster – Commercial (NEXT-C) gridded ion thruster proto-flight vibration test performed at the NASA Glenn Research Center’s Structural Dynamics Laboratory.

K. J. Pederson↗

High-Tc Superconducting Bolometer Noise Measurement Using Low Noise Transformers - Theory and Optimization

Care must always be taken when performing noise measurements on high-Tc superconducting materials to ensure that the results are not from the measurement system itself. One situation likely to occur is with low noise transformers. One of the least understood devices, it provides voltage gain for low impedance inputs (< 100 ), e.g., YBaCuO and GdBaCuO thin films, with comparatively lower noise levels than other devices for instance field effect and bipolar junction transistors. An essential point made in this paper is that because of the complex relationships between the transformer ports, input impedance variance alters the transformer s transfer function in particular, the low frequency cutoff shift. The transfer of external and intrinsic transformer noise to the output along with optimization and precautions are treated; all the while, we will cohesively connect the transfer function shift, the load impedance, and the actual noise at the transformer output.

Aslam, Shahid↗

Dipole and slot elements and arrays on semi-infinite substrates

The printed dipole or slot antenna on a semi-infinite substrate and infinite phased arrays of these elements are investigated. The solution is based on the moment method in the Fourier transform domain. The generalized impedance or admittance matrix can be expressed in rapidly converging infinite-integral or infinite-summation forms, allowing the accurate determination of the current distributions. Using the present formulation, the input impedance, resonant length, and radiation pattern for the isolated antennas, and the reflection coefficient for infinite phased arrays, are calculated.

Kominami, M.↗

Discontinuous Mode Power Supply

A document discusses the changes made to a standard push-pull inverter circuit to avoid saturation effects in the main inverter power supply. Typically, in a standard push-pull arrangement, the unsymmetrical primary excitation causes variations in the volt second integral of each half of the excitation cycle that could lead to the establishment of DC flux density in the magnetic core, which could eventually cause saturation of the main inverter transformer. The relocation of the filter reactor normally placed across the output of the power supply solves this problem. The filter reactor was placed in series with the primary circuit of the main inverter transformer, and is presented as impedance against the sudden changes on the input current. The reactor averaged the input current in the primary circuit, avoiding saturation of the main inverter transformer. Since the implementation of the described change, the above problem has not reoccurred, and failures in the main power transistors have been avoided.

Lagadinos, John↗

Microphone multiplex system provides multiple outlets from single source

Microphone multiplex system accepts an audio signal from a single source and provides any number of low impedance outputs at microphone level with complete isolation between output channels. Any input or output may be converted to high impedance by eliminating the associated transformer.

Lauver, R. E.↗

A low noise 230 GHz heterodyne receiver employing .25 sq micron area Nb/AlO(x)/Nb tunnel junctions

Recent results for a full height rectangular waveguide mixer with an integrated IF matching network are reported. Two 0.25 sq micron Nb/AlO(x)/Nb superconducting insulating superconducting (SIS) tunnel junctions with a current density of about 8500 A/sq cm and omega RC of about 2.5 at 230 GHz have been tested. Detailed measurements of the receiver noise have been made from 200-290 GHz for both junctions at 4.2 K. The lowest receiver noise temperatures were recorded at 239 GHz, measuring 48 K DSB at 4.2 K and 40 K DSB at 2.1 K. The 230 GHz receiver incorporates a one octave wide integrated low pass filter and matching network which transforms the pumped IF junction impedance to 50 ohms over a wide range of impedances.

Kooi, Jacob W.↗

Superconducting Films for Absorber-coupled MKID Detectors for Sub-millimeter and Far-infrared Astronomy

We describe measurements of the properties, at dc, gigahertz, and terahertz frequencies, of thin superconducting films with relatively high normal state sheet resistance. Such films can be applied to construct microwave kinetic inductance detector sensor arrays for submillimeter and far-infrared astronomical applications in which the incident power excites quasiparticles directly in a superconducting resonator that is configured to present a matched-impedance to the high frequency radiation being detected. For several materials, and a range of thicknesses down to 10 nm, we present measurements of normal state sheet resistance, resistance-temperature curves for the superconducting transition, quality factor and kinetic inductance fraction for microwave resonators made from patterned films, and terahertz measurements of the sheet impedance measured with a Fourier Transform Spectrometer.

Stevenson, T. R.↗

Antenna pattern control using impedance surfaces

During this research period, we have effectively transferred existing computer codes from CRAY supercomputer to work station based systems. The work station based version of our code preserved the accuracy of the numerical computations while giving a much better turn-around time than the CRAY supercomputer. Such a task relieved us of the heavy dependence of the supercomputer account budget and made codes developed in this research project more feasible for applications. The analysis of pyramidal horns with impedance surfaces was our major focus during this research period. Three different modeling algorithms in analyzing lossy impedance surfaces were investigated and compared with measured data. Through this investigation, we discovered that a hybrid Fourier transform technique, which uses the eigen mode in the stepped waveguide section and the Fourier transformed field distributions across the stepped discontinuities for lossy impedances coating, gives a better accuracy in analyzing lossy coatings. After a further refinement of the present technique, we will perform an accurate radiation pattern synthesis in the coming reporting period.

Balanis, Constantine A.↗

Method of detecting system function by measuring frequency response

Real-time battery impedance spectrum is acquired using a one-time record. Fast Summation Transformation (FST) is a parallel method of acquiring a real-time battery impedance spectrum using a one-time record that enables battery diagnostics. An excitation current to a battery is a sum of equal amplitude sine waves of frequencies that are octave harmonics spread over a range of interest. A sample frequency is also octave and harmonically related to all frequencies in the sum. The time profile of this signal has a duration that is a few periods of the lowest frequency. The voltage response of the battery, average deleted, is the impedance of the battery in the time domain. Since the excitation frequencies are known and octave and harmonically related, a simple algorithm, FST, processes the time record by rectifying relative to the sine and cosine of each frequency. Another algorithm yields real and imaginary components for each frequency.

Morrison, John L.↗

Stacked Transformer for Driver Gain and Receive Signal Splitting

In a high-speed signal transmission system that uses transformer coupling, there is a need to provide increased transmitted signal strength without adding active components. This invention uses additional transformers to achieve the needed gain. The prior art uses stronger drivers (which require an IC redesign and a higher power supply voltage), or the addition of another active component (which can decrease reliability, increase power consumption, reduce the beneficial effect of serializer/deserializer preemphasis or deemphasis, and/or interfere with fault containment mechanisms), or uses a different transformer winding ratio (which requires redesign of the transformer and may not be feasible with high-speed signals that require a 1:1 winding ratio). This invention achieves the required gain by connecting the secondaries of multiple transformers in series. The primaries of these transformers are currently either connected in parallel or are connected to multiple drivers. There is also a need to split a receive signal to multiple destinations with minimal signal loss. Additional transformers can achieve the split. The prior art uses impedance-matching series resistors that cause a loss of signal. Instead of causing a loss, most instantiations of this invention would actually provide gain. Multiple transformers are used instead of multiple windings on a single transformer because multiple windings on the same transformer would require a redesign of the transformer, and may not be feasible with high-speed transformers that usually require a bifilar winding with a 1:1 ratio. This invention creates the split by connecting the primaries of multiple transformers in series. The secondary of each transformer is connected to one of the intended destinations without the use of impedance-matching series resistors.

Driscoll, Kevin R.↗

A closely regulated TWT converter.

The design concept for the TWT amplifier converter for possible use in the Thermoelectric Outer Planet Spacecraft (TOPS) is presented. An unusual combination of semiconductors and magnetics was utilized to achieve very stable voltage regulation on a number of separate outputs to satisfy the requirements of a high-power TWT, and at the same time operate at an efficiency of better than 90% from a 30-V source. The circuitry consists of an output filter, an auxiliary Jensen oscillator driving a high-reactance transformer to provide current limiting to the heater, a variable time delay, a main Jensen oscillator driving the power transformer with a maximum step-up ratio of 120 to 1, and series transistorized post regulators to provide precise voltage adjustment and low output impedance. This paper discusses the design of the high-reactance transformer and the high step-up ratio transformer, as well as the high-voltage series regulators that are limited in range and operate at the top of the unregulated output voltage. Test data are presented, and details of current transients caused by charging the filter circuits, input current ripple, and output voltage ripples are considered.

Hopper, D. J.↗

Coupling of Helmholtz resonators to improve acoustic liners for turbofan engines at low frequency

An analytical and test program was conducted to evaluate means for increasing the effectiveness of low frequency sound absorbing liners for aircraft turbine engines. Three schemes for coupling low frequency absorber elements were considered. These schemes were analytically modeled and their impedance was predicted over a frequency range of 50 to 1,000 Hz. An optimum and two off-optimum designs of the most promising, a parallel coupled scheme, were fabricated and tested in a flow duct facility. Impedance measurements were in good agreement with predicted values and validated the procedure used to transform modeled parameters to hardware designs. Measurements of attenuation for panels of coupled resonators were consistent with predictions based on measured impedance. All coupled resonator panels tested showed an increase in peak attenuation of about 50% and an increase in attenuation bandwidth of one one-third octave band over that measured for an uncoupled panel. These attenuation characteristics equate to about 35% greater reduction in source perceived noise level (PNL), relative to the uncoupled panel, or a reduction in treatment length of about 24% for constant PNL reduction. The increased effectiveness of the coupled resonator concept for attenuation of low frequency broad spectrum noise is demonstrated.

Dean, L. W.↗

The role of rotor impedance in the vibration analysis of rotorcraft, part 4

A method for a strongly idealized case of vertical excitation and for rolling and pitching moment excitation of a four bladed hingeless rotor on an up-focussing flexible mount is developed. The aeroelastic rotor impedances are computed directly with a finite blade element method that includes aerodynamics. The rotor impedance matrix for three or more blades is determined from the root moment impedance for a single blade by a simple multiblade transformation rule. Force and moment amplitudes transferred from the rotor to support are found to be critically dependent on the support dynamics.

Hohenemser, K. H.↗