Search NASA⌕ Search

SEARCH · Search NASA

Results for “impervious surfaces”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

TPSAS-NF1676L-36113-DND

Concerns about the effects of extreme heat and poor air quality are increasing in North America’s largest urban centers. In Philadelphia, environmental and public health groups are concerned about how these phenomena disproportionality affect marginalized communities and populations, which often have extensive impervious surfaces and little access to green space. In order to address these concerns, the Philadelphia Department of Public Health and the Office of Sustainability seek to effectively prioritize cooling initiatives to reduce urban heat and decrease air pollutants. We evaluated land surface temperature (LST) and the Normalized Difference Vegetation Index (NDVI), as a measure of overall greenness, obtained from NASA Earth observations Aqua and Terra Moderate Resolution Imaging Spectroradiometer (MODIS), and the Ecosystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS). These analyses we recombined with local tree inventory, air quality, and socioeconomic data through a multivariate analysis to identify areas where new trees or cooling adaptations are most needed. The results and data of this project can be used by our partners to inform both short-term heat relief planning and a long-term, multi-agency heat response.

Spencer Nelson↗

Cincinnati & Covington Urban Development II: Assessing Flooding and Landslide Susceptibility Along the Ohio-Kentucky Border

Landslides and flooding are reoccurring environmental hazards that lead to health risks and economic burdens in the urban areas of Cincinnati, Ohio and Covington, Kentucky. These communities share underlying natural and artificial conditions that make them vulnerable to these hazards, including excessive precipitation, weak lithology, high impervious surface levels, and steep slopes. Despite the human and economic risks associated with these environmental hazards, the areas of highest vulnerability within the region remain unknown. NASA DEVELOP partnered with Groundwork USA and Groundwork Ohio River Valley (ORV) to assess the region’s susceptibility to landslides and flooding. The team utilized NASA Earth observations, including the Landsat 8 Operational Land Imager (OLI), Landsat 8 Thermal Infrared Sensor (TIRS), and Global Precipitation Measurement (GPM) Integrated Multi-satellitE Retrieval for GPM (IMERG), alongside ancillary datasets to map landslide susceptibility and exposure throughout the study area. The team also used ancillary data to map surface runoff and runoff retention using the Natural Capital Project’s Integrated Valuation of Ecosystem Services and Tradeoffs (InVEST) Urban Flood Risk Mitigation Model. The resulting landslide susceptibility and exposure maps highlight the neighborhoods around Avondale and Fairmount as areas of particularly high landslide exposure. Meanwhile, the InVEST outputs demonstrate that Downtown Cincinnati and the Queensgate neighborhood retain the least amount of rainfall. This research provides partners with a more complete hazard analysis of the greater Cincinnati area while also producing refined methodologies to enhance future flood and landslide vulnerability mapping throughout Groundwork USA’s nationwide network of communities.

Paxton LaJoie↗

Fairfax County Urban Development: Identifying Urban Heat Mitigation Strategies for Climate Adaptation Planning in Fairfax County, Virginia

Extreme high temperatures lead to increased instances of cardiovascular disease, pulmonary disease, and even death, as well as increased energy consumption and infrastructure costs. People in urbanized areas experience higher temperatures than rural areas due to diminished vegetation and increased impervious surfaces which absorb and radiate heat. Fairfax County, Virginia has embarked on Resilient Fairfax, a program aimed at addressing climate adaptation and resilience. The DEVELOP team partnered with the Fairfax County Office of Environmental and Energy Coordination (OEEC) to assess the extent of the urban heat island effect on the county and its most vulnerable populations. The team used data from Landsat 8 Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS), as well as the ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS) for the years 2013 to 2021 and found that the hottest spots were in densely urbanized areas, with temperatures as much as 47°F above that of undeveloped reference areas. The team used the Integrated Valuation of Ecosystem Services and Tradeoffs (InVEST) urban cooling model and determined that areas with higher tree canopy cover had greater heat mitigation capacity. Estimates from the InVEST model showed that a 4.5% increase in canopy cover across the county could result in a temperature reduction of up to 2.4°F in some areas. The results will allow partners to assess heat distribution across Fairfax County and implement effective mitigation strategies, including locating prime locations for cooling centers and increasing canopy cover.

W. Pierce Holloway↗

Assessing Urban Heat in the Cincinnati and Covington Area to Inform Local Decision-Makers and Environmental Justice Initiatives

The Urban Heat Island effect is a phenomenon characterized by urban areas experiencing temperatures that are, on average, warmer than surrounding suburban and rural regions. Urban Heat Islands are fueled by expansive impervious surfaces, vehicle emissions, and insufficient urban green space. Densely populated urban centers like the Cincinnati, Ohio and Covington, Kentucky area can experience negative health impacts due to the Urban Heat Island. NASA DEVELOP partnered with Groundwork USA and Groundwork Ohio River Valley to combine environmental education and outreach with technical capacity building in NASA Earth observations. The DEVELOP team used Landsat 5 TM and ISS ECOSTRESS to calculate daytime and nighttime land surface temperature anomalies. The team found that the Cincinnati and Covington area was 8.32°F warmer during the day and 4.97°F warmer at night compared to non-urban areas. The team also ran the Natural Capital Project InVEST Urban Cooling Model to map a heat mitigation index for the study area. The heat mitigation index models the cooling capacity of each pixel and the effect of green spaces on the pixel’s ability to mitigate heat. Results show which communities are most vulnerable to impacts of increased urban heat. The team also assessed alternative tree canopy scenarios with the InVEST model to better understand the effectiveness of potential heat mitigation strategies. Increasing tree canopy cover by 25% in urbanized land cover types was found to reduce mean temperature across the study area by 0.87°F. Combining these results with work from Groundwork’s Climate Safe Neighborhoods program highlights the relationship between extreme heat and historical-race based housing practices in the region. Results provide partners at Groundwork with refined methodologies to support future education and outreach, as well as increase future capacity to NASA Earth observations.

Celeste Gambino↗

Continued Increases of Gross Primary Production in Urban Areas During 2000–2016

Urbanization affects vegetation within city administrative boundary and nearby rural areas. Gross primary production (GPP) of vegetation in global urban areas is one of important metrics for assessing the impacts of urbanization on terrestrial ecosystems. To date, very limited data and information on the spatial-temporal dynamics of GPP in the global urban areas are available. In this study, we reported the spatial distribution and temporal dynamics of annual GPP during 2000–2016 from 8,182 gridcells (0.5° by 0.5° latitude and longitude) that have various proportion of urban areas. Approximately 79.3% of these urban gridcells had increasing trends of annual GPP during 2000-2016. As urban area proportion (%) within individual urban gridcells increased, the means of annual GPP trends also increased. Our results suggested that for those urban gridcells, the negative effect of urban expansion (often measured by impervious surfaces) on GPP was to large degree compensated by increased vegetation within the gridcells, mostly driven by urban management and local climate and environment. Our findings on the continued increases of annual GPP in most of urban gridcells shed new insight on the importance of urban areas on terrestrial carbon cycle and the potential of urban management and local climate and environment on improving vegetation in urban areas.

Yaoping Cui↗

Youngstown and Warren Disasters: Mapping Flood Susceptibility, Vulnerability, and Risk and Tree Canopy Coverage in Northern Ohio to Inform Stormwater Management and Flood Mitigation Efforts

Both pluvial and fluvial flooding events pose direct challenges on urban infrastructure and communities across the United States. Heavy rainfall events oversaturate the ground, overflow waterbodies, and overwhelm stormwater infrastructure. Vulnerable areas receive heavy damage from flooding events due to physical factors like increased impervious surfaces, poor stormwater systems, and limited greenspaces. These vulnerable neighborhoods are comprised of aging populations, minority communities, and lower income levels. Lack of data in these communities have made it difficult to implement policymaking and flood mitigation strategies. Using the Urban Flood Risk Mitigation model (InVEST) and the PlanetScope satellite constellation, the team visualized historical flooding and tree canopy coverage as a measure of flood susceptibility. The team also used the Arc-Malstrom model to provide further insight into where flooding accumulates via surface elevation depressions in the study area. To validate these models, the team explored the spatial variation of rainfall events using NASA’s Integrated Multi-satellite Retrievals for Global Precipitation Measurement (GPM IMERG). The resulting maps highlight areas surrounding the cities of Youngstown and Warren as being the most flood susceptible and socially vulnerable, while the city centers contain the lowest tree canopy coverage. The DEVELOP team collaborated with the Environmental Collaborative of Ohio (ECO) to create products for end users within the City of Warren’s Water Pollution Control Department, the Eastgate Regional Council of Governments and the Healthy Community Partnership of Mahoning Valley. These products help identify target areas for preventative flood mitigation measures as well as areas ideal for green infrastructure intervention.

InVEST Urban Flood Risk Mitigation Model↗

Shallow Soil Polychlorinated Biphenyl Site Assessment Report

This report presents a summary of the shallow soil polychlorinated biphenyl (PCB) site assessment activities that occurred from December 2020 through July 2022 at General Services Administration Reclamation Yard, Solid Waste Management Unit (SWMU) 010, located at the John F. Kennedy Space Center (KSC), Florida. The site is monitored under KSC’s Resource Conservation and Recovery Act Corrective Action Program, which also meets the requirements of Chapter 62-780, Florida Administrative Code. For the purposes of this report, three separate shallow soil plumes, known as the Northeast Shallow Soil PCB Plume, Southeast Shallow Soil PCB Plume, and West Shallow Soil PCB Plume, were identified for this site. The activities presented in this report include seven field events conducted between December 2020 and July 2022, which include shallow soil sample collection in the Northeast, Southeast, and West Shallow Soil PCB Plumes. AECOM Technical Services, Inc., personnel collected 330 soil samples from 118 boring locations. The samples were collected at 0.5-foot depth intervals to various depths based on analytical results and depth to groundwater. The soil samples were submitted to a fixed-based laboratory for analysis by United States Environmental Protection Agency Method 8082A for total PCBs. Several soil samples had PCB concentrations above the State of Florida Direct Exposure Residential and Industrial Soil Cleanup Target Levels (SCTLs), and two soil samples had PCB concentrations above the State of Florida Leachability for Groundwater. No soil borings were located beneath impervious surfaces, such as concrete or asphalt. The current Land Use Control Implementation Plan (LUCIP) covers PCBs in soils above the residential SCTL, which includes the paved areas.

PCBs↗

Baltimore Energy & Infrastructure: Assessing Urban Heat Vulnerability in Baltimore Neighborhoods to Inform Transportation Resiliency Planning Efforts

Across the world, climate change is altering cities and their local climate systems. Following global trends of rising mean temperatures, Baltimore, Maryland is projected to experience more frequent extreme heat events. Exacerbated by Urban Heat Island (UHI) effects, residents of the city face high temperatures from limited tree canopy, highly paved and impervious surfaces, limited air flow, and high concentrations of localized emissions. Urban heat is dispersed asymmetrically, with historically marginalized populations experiencing disproportionately severe heat. Recognizing the impacts of extreme urban heat, the Maryland Transit Administration (MTA) collaborated with us, the Spring 2024 Goddard Energy and Infrastructure NASA DEVELOP team to assess urban impacts of MTA users and assets and explore opportunities to enhance resiliency planning. We evaluated the feasibility of NASA Earth observations (EOs) in visualizing heat vulnerability in Baltimore City and County. We mapped UHI and extreme heat using remote sensing observations, tailored a Heat Priority Score (HPS) to analyze heat data in tandem with socioeconomic data from American Community Survey (ACS), and utilized SOlar and LongWave Environmental Irradiance Geometry (SOLWEIG) model to estimate MTA riders’ thermal comfort. NASA EOs served to quantify the distribution and severity of extreme heat at the block group level, which was found to correlate with a lack of vegetation and presence of densely built-up surroundings. The HPS revealed that extreme heat events most negatively impact communities that exhibit social vulnerability through indicators such as age, race, and income. These findings will inform neighborhood resiliency plans for the MTA that can be incorporated into their Adaptation Resiliency Toolbox (ART).

Baltimore,↗

Bridgeport Urban Development: Leveraging NASA Earth Observations and Sociodemographic Data to Assess Urban Heat Vulnerability and Inform Cool Corridors in Bridgeport, Connecticut

Urban environments face hotter temperatures than suburban and rural areas due to higher concentrations of impervious surfaces, heat-retaining buildings, and lack of green space. Bridgeport, Connecticut, which was formerly a national manufacturing hub, is now the densest and most populous city in the state. Bridgeport experiences hotter temperatures, exposing its residents to more extreme temperatures than the surrounding affluent suburbs. Extreme heat affects the health of those exposed to it and intensifies energy demands. Understanding temperature differences is the first step in effectively directing mitigation efforts. Our partner, Groundwork Bridgeport, along with the Yale Urban Design Workshop, are planning a “cool corridors” project, implementing cooling infrastructure to combat urban heat. We used Landsat 8 Thermal Infrared Sensor and Landsat 9 Thermal Infrared Sensor-2 data to conduct a Land Surface Temperature analysis in Google Earth Engine for the county of Fairfield. A Principal Component Analysis was performed to identify indicators of social vulnerability in Bridgeport. We used the SOlar and LongWave Environmental Irradiance Geometry model to identify felt heat on the block level to inform where the partner should locate their cooling interventions to ensure they are most effective and equitable. We focused on the East Side of Bridgeport, which we found was 10 degrees hotter than other areas of Bridgeport and the neighboring town of Fairfield. We integrated our findings using Earth observations and additional sociodemographic and climate data into final communication products for our partners which will facilitate their selection of candidate locations for their Cool Corridors project.

Silas Kirsch↗

Shallow Soil Polychlorinated Biphenyl Site Assessment Report: General Services Administration Reclamation Yard Solid Waste Management Unit 010

This report presents a summary of the shallow soil polychlorinated biphenyl (PCB) site assessment activities that occurred from December 2020 through July 2022 at General Services Administration Reclamation Yard, Solid Waste Management Unit (SWMU) 010, located at the John F. Kennedy Space Center (KSC), Florida. The site is monitored under KSC’s Resource Conservation and Recovery Act Corrective Action Program, which also meets the requirements of Chapter 62-780, Florida Administrative Code. For the purposes of this report, three separate shallow soil plumes, known as the Northeast Shallow Soil PCB Plume, Southeast Shallow Soil PCB Plume, and West Shallow Soil PCB Plume, were identified for this site. The activities presented in this report include seven field events conducted between December 2020 and July 2022, which include shallow soil sample collection in the Northeast, Southeast, and West Shallow Soil PCB Plumes. AECOM Technical Services, Inc., personnel collected 330 soil samples from 118 boring locations. The samples were collected at 0.5-foot depth intervals to various depths based on analytical results and depth to groundwater. The soil samples were submitted to a fixed-based laboratory for analysis by United States Environmental Protection Agency Method 8082A for total PCBs. Several soil samples had PCB concentrations above the State of Florida Direct Exposure Residential and Industrial Soil Cleanup Target Levels (SCTLs), and two soil samples had PCB concentrations above the State of Florida Leachability for Groundwater. No soil borings were located beneath impervious surfaces, such as concrete or asphalt. The current Land Use Control Implementation Plan (LUCIP) covers PCBs in soils above the residential SCTL, which includes the paved areas.

soil assessment↗

Sputtered gold mask for deep chemical etching of silicon

Sputtered mask resists chemical attack from acid and has adherence to withstand prolonged submergence in etch solution without lifting from silicon surface. Even under prolonged etch conditions with significant undercutting, gold mask maintained excellent adhesion to silicon surface and imperviousness to acid.

Pisciotta, B. P.↗

Remote sensing requirements as suggested by watershed model sensitivity analyses

A continuous simulation watershed model has been used to perform sensitivity analyses that provide guidance in defining remote sensing requirements for the monitoring of watershed features and processes. The results show that out of 26 input parameters having meaningful effects on simulated runoff, 6 appear to be obtainable with existing remote sensing techniques. Of these six parameters, 3 require the measurement of the areal extent of surface features (impervious areas, water bodies, and the extent of forested area), two require the descrimination of land use that can be related to overland flow roughness coefficient or the density of vegetation so as to estimate the magnitude of precipitation interception, and one parameter requires the measurement of distance to get the length over which overland flow typically occurs. Observational goals are also suggested for monitoring such fundamental watershed processes as precipitation, soil moisture, and evapotranspiration. A case study on the Patuxent River in Maryland shows that runoff simulation is improved if recent satellite land use observations are used as model inputs as opposed to less timely topographic map information.

Salomonson, V. V.↗

Temporal Consistency Between Gross Primary Production and Solar-Induced Chlorophyll Fluorescence in the Ten Most Populous Megacity Areas over Years

The gross primary production (GPP) of vegetation in urban areas plays an important role in the study of urban ecology. It is difficult however, to accurately estimate GPP in urban areas, mostly due to the complexity of impervious land surfaces, buildings, vegetation, and management. Recently, we used the Vegetation Photosynthesis Model (VPM), climate data, and satellite images to estimate the GPP of terrestrial ecosystems including urban areas. Here, we report VPM-based GPP (GPPvpm) estimates for the world's ten most populous megacities during 2000-2014. The seasonal dynamics of GPPvpm during 2007-2014 in the ten megacities track well that of the solar-induced chlorophyll fluorescence (SIF) data from GOME-2 at 0.5deg x 0.5deg resolution. Annual GPPvpm during 2000-2014 also shows substantial variation among the ten megacities, and year-to-year trends show increases, no change, and decreases. Urban expansion and vegetation collectively impact GPP variations in these megacities. The results of this study demonstrate the potential of a satellite-based vegetation photosynthesis model for diagnostic studies of GPP and the terrestrial carbon cycle in urban areas.

urban↗

Passivation of high temperature superconductors

The surface of high temperature superconductors such as YBa2Cu3O(7-x) are passivated by reacting the native Y, Ba and Cu metal ions with an anion such as sulfate or oxalate to form a surface film that is impervious to water and has a solubility in water of no more than 10(exp -3) M. The passivating treatment is preferably conducted by immersing the surface in dilute aqueous acid solution since more soluble species dissolve into the solution. The treatment does not degrade the superconducting properties of the bulk material.

Vasquez, Richard P.↗

Unitary plate electrode

The unitary electrode (10) comprises a porous sheet (12) of fiberglass the strands (14) of which contain a coating (16) of conductive tin oxide. The lower portion of the sheet contains a layer (18) of resin and the upper layer (20) contains lead dioxide forming a positive active electrode on an electrolyte-impervious layer. The strands (14) form a continuous conduction path through both layers (16, 18). Tin oxide is prevented from reduction by coating the surface of the plate facing the negative electrode with a conductive, impervious layer resistant to reduction such as a thin film (130) of lead or graphite filled resin adhered to the plate with a layer (31) of conductive adhesive. The plate (10) can be formed by casting a molten resin from kettle (60) onto a sheet of glass wool (56) overlying a sheet of lead foil and then applying positive active paste from hopper (64) into the upper layer (68). The plate can also be formed by passing an assembly of a sheet ( 80) of resin, a sheet (86) of sintered glass and a sheet (90) of lead between the nip (92) of heated rollers (93, 95) and then filling lead oxide into the pores (116) of the upper layer (118).

Rowlette, John J.↗

Low defect, high purity crystalline layers grown by selective deposition

The purity and perfection of a semiconductor is improved by depositing a patterned mask of a material impervious to impurities of the semiconductor on a surface of a blank. When a layer of semiconductor is grown on the mask, the semiconductor will first grow from the surface portions exposed by the openings in the mask and will bridge the connecting portions of the mask to form a continuous layer having improved purity, since only the portions overlying the openings are exposed to defects and impurities.

Morrison, A. D.↗

Method for growing low defect, high purity crystalline layers utilizing lateral overgrowth of a patterned mask

A method for growing a high purity, low defect layer of semiconductor is described. This method involves depositing a patterned mask of a material impervious to impurities of the semiconductor on a surface of a blank. When a layer of semiconductor is grown on the mask, the semiconductor will first grow from the surface portions exposed by the openings in the mask and will bridge the connecting portions of the mask to form a continuous layer having improved purity, since only the portions overlying the openings are exposed to defects and impurities. The process can be iterated and the mask translated to further improve the quality of grown layers.

Morrison, Andrew D.↗

High pressure mechanical seal

A relatively impervious mechanical seal is formed between the outer surface of a tube and the inside surface of a mechanical fitting of a high pressure fluid or hydraulic system by applying a very thin soft metal layer onto the outer surface of the hard metal tube and/or inner surface of the hard metal fitting, prior to swaging the fitting onto the tube. The thickness of such thin metal layer is independent of the size of the tube and/or fittings. Many metals and alloys of those metals exhibit the requisite softness, including silver, gold, nickel, tin, platinum, indium, rhodium and cadmium. Suitably, the coating is about 0.0025 millimeters (0.10 mils) in thickness. After swaging, the tube and fitting combination exhibits very low leak rates on the order or 10.sup.-8 cubic centimeters per second or less as meaured using the Helium leak test.