Solar event signatures impressed upon spacecraft radio signals
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Deep Impact will impact the comet Tempel-1 on July 4, 2005. The impact event will be clearly visible from small telescopes on Earth, especially in the IR bands. When combined with observations taken from the Flyby spacecraft, this science data set will provide unique insight into the materials and structure within the comet, and the strength of the surface.
Explore the source record for details and available documents.
CARTOSAT-1 RPCs need special handling. Absolute accuracy of uncontrolled scenes is poor (biases > 300 m). Noticeable cross-track scale error (+/- 3-4 m across stereo pair). Most errors are either biases or linear in line/sample (These are easier to correct with ground control).
The Mission Operations Laboratory (MOL) at Marshall Space Flight Center (MSFC) is responsible for Engineering Support capability for NASA s Ares rocket development and operations. In pursuit of this, MOL is building the Ares Engineering and Operations Network (AEON), a web-based portal to support and simplify two critical activities: Access and analyze Ares manufacturing, test, and flight performance data, with access to Shuttle data for comparison Establish and maintain collaborative communities within the Ares teams/subteams and with other projects, e.g., Space Shuttle, International Space Station (ISS). AEON seeks to provide a seamless interface to a) locally developed engineering applications and b) a Commercial-Off-The-Shelf (COTS) collaborative environment that includes Web 2.0 capabilities, e.g., blogging, wikis, and social networking. This paper discusses how Web 2.0 might be applied to the typically conservative engineering support arena, based on feedback from Integration, Verification, and Validation (IV&V) testing and on searching for their use in similar environments.
Katie Baldwin (University of Alabama Huntsville) and Helen Parache (NASA Marshall Space Flight Center) collaborated on a pilot project with two upper division printmaking classes at the UAH Art Department in Spring 2023. Presentations and guided discussions focused on what artists and scientists can learn from each other, drawing from the larger discourse, and an introduction to artists that incorporate scientific data in their work. Parache and Baldwin facilitated a series of activities where students engaged with data to develop content. Each session ended with creating a plan with each student for a data-driven project utilizing printmaking which was shared in a talk open to the public. This pilot collaboration brought up themes of accessibility, social relevance, emotional truth, and creative solutions. Next steps include repeating the workshop with tweaks in Fall 2023 and strengthening relationships between artists and scientists co-located in Huntsville, Alabama.
Case study describes how Ravalli Electric Cooperative helped the Trapper Creek Job Corp learn ways to be more energy efficient after Trapper Creek found out power costs were increasing.
Summary of the state of the wind industry from 1980 through today, including an overview of codes, design tools, next-generation design and fabrication, testing, market acceleration, and resource characterization.
Abstract not provided.
The award of American Recovery and Reinvestment Act funding came with an unprecedented request for transparency to showcase to the American public how the stimulus funding was being put to work to achieve the goals put forth by the U.S. Government. At the U.S. Department of Energy Hanford Site, this request manifested in a contract requirement to provide weekly narrative, photos and video to highlight Recovery Act-funded projects. For DOE contractor CH2M HILL Plateau Remediation Company (CH2M HILL), the largest recipient of Hanford's funding, the reporting mechanism evolved into a communications tool for documenting the highly technical cleanup, then effectively sharing that story with the DOE and its varying stakeholder audiences. The report set the groundwork for building a streaming narrative of week-by-week progress. With the end of the Recovery Act, CH2M HILL is applying lessons learned from this stringent, transparent reporting process to its long-term reporting and communications of the progress being made in nuclear decommissioning at Hanford. (authors)
A method that provides an impression profile in a reference standard material utilized in inspecting critically stressed components with pulsed ultrasound is described. A die stamp having an I letter is used to impress the surface of a reference material. The die stamp is placed against the surface and struck with an inertia imparting member to impress the I in the reference standard material. Upset may appear on the surface as a result of the impression and is removed to form a smooth surface. The stamping and upset removal is repeated until the entire surface area of a depth control platform on the die stamp uniformly contacts the material surface. The I impression profile in the reference standard material is utilized for reflecting pulsed ultrasonic beams for inspection purposes.
Purpose: The purpose of the study is to assess the reader agreement and accuracy of eight ultrasound imaging features for classifying hepatic steatosis in adults with known or suspected hepatic steatosis. Methods: This was an IRB-approved, HIPAA-compliant prospective study of adult patients with known or suspected hepatic steatosis. All patients signed written informed consent. Ultrasound images (Siemens S3000, 6C1HD, and 4C1 transducers) were acquired by experienced sonographers following a standard protocol. Eight readers independently graded eight features and their overall impression of hepatic steatosis on ordinal scales using an electronic case report form. Duplicated images from the 6C1HD transducer were read twice to assess intra-reader agreement. Intra-reader, inter-transducer, and inter-reader agreement were assessed using intraclass correlation coefficients (ICC). Features with the highest intra-reader agreement were selected as predictors for dichotomized histological steatosis using Classification and Regression Tree (CART) analysis, and the accuracy of the decision rule was compared to the accuracy of the radiologists’ overall impression. Results: 45 patients (18 males, 27 females; mean age 56 ± 12 years) scanned from September 2015 to July 2016 were included. Mean intra-reader ICCs ranged from 0.430 to 0.777, inter-transducer ICCs ranged from 0.228 to 0.640, and inter-reader ICCs ranged from 0.014 to 0.561. The CART decision rule selected only large hepatic vein blurring and achieved similar accuracy to the overall impression (74% to 75% and 68% to 72%, respectively). Conclusions: Large hepatic vein blurring, liver–kidney contrast, and overall impression provided the highest reader agreement. Large hepatic vein blurring may provide the highest classification accuracy for dichotomized grading of hepatic steatosis.
Metal halide perovskite solar cell (PSC) technology has an impressive power conversion efficiency (PCE) exceeding 26.1% and demonstrates cost-effective manufacturing. However, the stability of these PSCs poses a significant challenge, hindering their widespread manufacturing and commercialization. To tackle the degradation issue inherent in PSCs, surface passivation techniques, particularly employing a thin layer of two-dimensional (2D) perovskites, create a 2D/3D heterostructure. Beyond this, the exploration of metal halide double perovskites adds a new dimension to the chemical and band gap phase space of materials for optoelectronic applications. In this study, we leverage a wide band gap double perovskite interlayer to enhance the stability of 3D metal halide perovskite. Specifically, the double perovskite nanoparticle Cs 2 AgBiBr 6 , with its substantial band gap of 2.2 eV and exceptional air stability, is utilized. Through optimization, a Cs 2 AgBiBr 6 -treated PSC achieves an open-circuit voltage of 1.12 V and an impressive PCE of 19.52%. Additionally, the Cs 2 AgBiBr 6 passivation layer proves to be effective in bolstering the stability of PSCs. This work demonstrates an additional strategy and design motif to simultaneously increase the PCE of PSCs along with achieving improved stability.
We introduce a new family of complexes with the general formula [Run(tda)(py)2]m+ (n = 2, m = 0, 1; n = 3, m = 1, 2+; n = 4, m = 2, 32+), with tda2– being [2,2':6',2''-terpyridine]-6,6''-dicarboxylate, including complex [RuIV(OH)(tda-κ-N3O)(py)2]+, 4H+, which we find to be an impressive water oxidation catalyst, formed by hydroxo coordination to 32+ under basic conditions. The complexes are synthesized, isolated, and thoroughly characterized by analytical, spectroscopic (UV–vis, nuclear magnetic resonance, electron paramagnetic resonance), computational, and electrochemical techniques (cyclic voltammetry, differential pulse voltammetry, coulometry), including solid-state monocrystal X-ray diffraction analysis. In oxidation state IV, the Ru center is seven-coordinated and diamagnetic, whereas in oxidation state II, the complex has an unbonded dangling carboxylate and is six-coordinated while still diamagnetic. With oxidation state III, the coordination number is halfway between the coordination of oxidation states II and IV. Species generated in situ have also been characterized by spectroscopic, computational, and electrochemical techniques, together with the related species derived from a different degree of protonation and oxidation states. 4H+ can be generated potentiometrically, or voltammetrically, from 32+, and both coexist in solution. While complex 32+ is not catalytically active, the catalytic performance of complex 4H+ is characterized by the foot of the wave analysis, giving an impressive turnover frequency record of 8000 s–1 at pH 7.0 and 50 000 s–1 at pH 10.0. Density functional theory calculations provide a complete description of the water oxidation catalytic cycle of 4H+, manifesting the key functional role of the dangling carboxylate in lowering the activation free energies that lead to O–O bond formation.
This report summarizes the status of the concentrator photovoltaic (CPV) market and industry as well as current trends in research and technology. This report is intended to guide research agendas for Fraunhofer ISE, the National Renewable Energy Laboratory (NREL), and other R&D organizations. Version 1.1 of this report includes recent progress in CPV. The recent record module efficiency of 38.9% at Concentrator Standard Test Conditions (CSTC) is an impressive result, demonstrating the continuing opportunity for CPV technology to improve. 38.9% at Concentrator Standard Test Conditions (CSTC) is an impressive result, demonstrating the continuing opportunity for CPV technology to improve. 38.9% at Concentrator Standard Test Conditions (CSTC) is an impressive result, demonstrating the continuing opportunity for CPV technology to improve. 38.9% at Concentrator Standard Test Conditions (CSTC) is an impressive result, demonstrating the continuing opportunity for CPV technology to improve.
Purpose: To assess inter-radiologist agreement using the Society of Abdominal Radiology-American Gastroenterological Association (SAR-AGA) consensus recommendations for reporting CT/MR enterography exams in pediatric and young adult small bowel Crohn disease (CD). Methods: Institutional review board approval was obtained for this HIPAA-compliant retrospective investigation; the requirement for informed consent was waived. 25 CT and 25 MR enterography exams performed in children and young adults (age range: 6–23 years) between January 2015 and April 2017 with a distribution of ileal CD severity (phenotype) were identified: normal or chronic CD without active inflammation (40%), active inflammatory CD (20%), stricturing CD (20%), and penetrating CD (20%). Five fellowship-trained pediatric radiologists, blinded to one another, documented key imaging findings and standardized impressions based on SAR-AGA consensus recommendations. Inter-radiologist agreement was evaluated using Fleiss’ multi-rater kappa statistic (κ) with 95% confidence intervals (CI). Results: Inter-radiologist agreement was moderate for all key imaging findings except presence of ulcerations (κ 0.37 [95% CI 0.28–0.46]) and sacculations (κ 0.31 [95% CI 0.23–0.40]). Agreement for standardized impressions was substantial for stricturing disease (κ 0.79 [95% CI 0.70–0.87]) and moderate for presence of inflammation (κ 0.49 [95% CI 0.44–0.56]) and penetrating disease (κ 0.58 [95% CI 0.49–0.67]). No significant difference in agreement was found between CT and MRI. Conclusions: Agreement among five pediatric radiologists was moderate to substantial for SAR-AGA standardized impressions and fair to moderate for key imaging findings of pediatric and young adult CD.
The integration of additive manufacturing (AM) technology with compression molding (CM), has emerged as a high-performance composite manufacturing technology in recent years. In the AM-CM process, quickly deposited AM preform on a mold undergoes a rapid compaction cycle to fabricate structurally robust composite parts due to highly controlled fiber alignment (from AM) and reduced porosity (from CM). Currently, AMCM-based part size is limited by the size of the mold volume, thus posing a challenge to manufacture scalable parts. Here, this work focuses on joining techniques developed to enable fast rate joining of short fiber-reinforced thermoplastic composite parts using the AM-CM process. Acrylonitrile butadiene styrene resin reinforced with 20 wt% short carbon fiber composites was printed onto a flat mold and pressed under a hydraulic press. Fabricated panels were joined by the (a) mechanical impression at the joining interface and (b) over-molded continuous carbon fiber (CCF) sheet. Tensile tests were performed to characterize the joining strength of both mechanical impression-based joints and CCF over molded joints. Among the mechanical impression-based joints, a U-shape channel allowed the fibers to flow between two joint parts, and 280 % increased mechanical properties were observed. The continuous carbon fiber-based over molded joint CCF showed 350 % increase in tensile strength compared to the butt joints.