Search NASASearch

SEARCH · Search NASA

Results for “improve standardization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Keywords for All People: How Keyword Governance and Coordination with the NASA ESDIS Standards Coordination Office (ESCO) Improves GCMD Keywords for Discuvery and Use

The Global Change Master Directory (GCMD) Keywords, initiated over twenty years ago, are a hierarchical set of controlled Earth Science vocabularies that help ensure Earth science data, services, and variables are described in a consistent and comprehensive manner and allow for the precise searching of metadata and subsequent retrieval of data, services, and variables. GCMD keywords are periodically analyzed for relevancy and will continue to be refined and expanded in response to user needs. The periodic analysis is a result of successful coordination with the ESDIS Standards Coordination Office (ESCO), which is responsible for standards activities across ESDIS, and assists with providing valuable stakeholder and subject matter expert (SME) feedback on GCMD vocabularies. The ESCO is also turning to the GCMD to discuss how the keyword review process can be improved and more streamlined. In addition to the ESCO, keyword requests and feedback are also received through the GCMD Keyword Forum.

Tyler Stevens

MISIP: a data standard for the reuse and reproducibility of any stable isotope probing-derived nucleic acid sequence and experiment

DNA/RNA-stable isotope probing (SIP) is a powerful tool to link in situ microbial activity to sequencing data. Every SIP dataset captures distinct information about microbial community metabolism, process rates, and population dynamics, offering valuable insights for a wide range of research questions. Data reuse maximizes the information derived from the labor and resource-intensive SIP approaches. Yet, a review of publicly available SIP sequencing metadata showed that critical information necessary for reproducibility and reuse was often missing. Here, we outline the Minimum Information for any Stable Isotope Probing Sequence (MISIP) according to the Minimum Information for any (x) Sequence (MIxS) framework and include examples of MISIP reporting for common SIP experiments. Our objectives are to expand the capacity of MIxS to accommodate SIP-specific metadata and guide SIP users in metadata collection when planning and reporting an experiment. The MISIP standard requires 5 metadata fields—isotope, isotopolog, isotopolog label, labeling approach, and gradient position—and recommends several fields that represent best practices in acquiring and reporting SIP sequencing data (e.g., gradient density and nucleic acid amount). The standard is intended to be used in concert with other MIxS checklists to comprehensively describe the origin of sequence data, such as for marker genes (MISIP-MIMARKS) or metagenomes (MISIP-MIMS), in combination with metadata required by an environmental extension (e.g., soil). The adoption of the proposed data standard will improve the reuse of any sequence derived from a SIP experiment and, by extension, deepen understanding of in situ biogeochemical processes and microbial ecology.

Simpson, Abigayle

Lamp reliability studies for improved satellite rubidium frequency standard

In response to the premature failure of Rb lamps used in Rb atomic clocks onboard NAVSTAR GPS satellites experimental and theoretical investigations into their failure mechanism were initiated. The primary goal of these studies is the development of an accelerated life test for future GPS lamps. The primary failure mechanism was identified as consumption of the lamp's Rb charge via direct interaction between Rb and the lamp's glass surface. The most effective parameters to accelerate the interaction between the Rb and the glass are felt to be RF excitation power and lamp temperature. Differential scanning calorimetry is used to monitor the consumption of Rb within a lamp as a function of operation time. This technique yielded base line Rb consumption data for GPS lamps operating under normal conditions.

Frueholz, R. P.

ESIP Information Quality Cluster (IQC)

The Information Quality Cluster (IQC) within the Federation of Earth Science Information Partners (ESIP) was initially formed in 2011 and has evolved significantly over time. The current objectives of the IQC are to: 1. Actively evaluate community data quality best practices and standards; 2. Improve capture, description, discovery, and usability of information about data quality in Earth science data products; 3. Ensure producers of data products are aware of standards and best practices for conveying data quality, and data providers distributors intermediaries establish, improve and evolve mechanisms to assist users in discovering and understanding data quality information; and 4. Consistently provide guidance to data managers and stewards on how best to implement data quality standards and best practices to ensure and improve maturity of their data products. The activities of the IQC include: 1. Identification of additional needs for consistently capturing, describing, and conveying quality information through use case studies with broad and diverse applications; 2. Establishing and providing community-wide guidance on roles and responsibilities of key players and stakeholders including users and management; 3. Prototyping of conveying quality information to users in a more consistent, transparent, and digestible manner; 4. Establishing a baseline of standards and best practices for data quality; 5. Evaluating recommendations from NASA's DQWG in a broader context and proposing possible implementations; and 6. Engaging data providers, data managers, and data user communities as resources to improve our standards and best practices. Following the principles of openness of the ESIP Federation, IQC invites all individuals interested in improving capture, description, discovery, and usability of information about data quality in Earth science data products to participate in its activities.

data products

Building the Next Generation Technology Transfer Information System

The Defense Technology Transfer Information System (DTTIS) is a scalable data system built to grow and adapt to changing conditions. It collects information from each technology transfer offices, patent attorneys, innovators, and more. It automates workflows to standardize and streamline technology transfer business rules. This resulting in improved efficiency, standardized processes and reducing errors. DTTIS is a search and reporting engine built on patented NASA's Technology Transfer System (NTTS) core software platform.

Tran, Peter B.

Wasserstein normalized autoencoder for anomaly detection

A novel anomaly detection algorithm is presented. The Wasserstein normalized autoencoder (WNAE) is a normalized probabilistic model that minimizes the Wasserstein distance between the learned probability distribution—a Boltzmann distribution where the energy is the reconstruction error of the autoencoder (AE)—and the distribution of the training data. This algorithm has been developed and applied to the identification of semivisible jets—conical sprays of visible standard model (SM) particles and invisible dark matter states—with the CMS experiment at the CERN LHC. Trained on jets of particles from simulated SM processes, the WNAE is shown to learn the probability distribution of the input data in a fully unsupervised fashion, such that it effectively identifies new physics jets as anomalies. The model exhibits stable, convergent training and recovers strong classification performance for a wide range of signals against the selected background process, for which a standard AE fails because of outlier reconstruction. In addition, the model improves upon standard normalized autoencoders while remaining fully agnostic to the signal. The WNAE directly tackles the problem of outlier reconstruction, a common failure mode of autoencoders in anomaly detection tasks.

Hayrapetyan, Aram [Yerevan Phys. Inst.]

On-board Attitude Determination System (OADS)

The requirements, capabilities and system design for an on-board attitude determination system (OADS) to be flown on advanced spacecraft missions were determined. Based upon the OADS requirements and system performance evaluation, a preliminary on-board attitude determination system is proposed. The proposed OADS system consists of one NASA Standard IRU (DRIRU-2) as the primary attitude determination sensor, two improved NASA Standard star tracker (SST) for periodic update of attitude information, a GPS receiver to provide on-board space vehicle position and velocity vector information, and a multiple microcomputer system for data processing and attitude determination functions. The functional block diagram of the proposed OADS system is shown. The computational requirements are evaluated based upon this proposed OADS system.

Carney, P.

Investigations of laser pumped gas cell atomic frequency standard

The performance characteristics of a rubidium gas cell atomic frequency standard might be improved by replacing the standard rubidium discharge lamp with a single mode laser diode. Aspects of the laser pumped gas cell atomic clock studied include effects due to laser intensity, laser detuning, and the choice of the particular atomic absorption line. Results indicate that the performance of the gas cell clock may be improved by judicious choice of the operating parameters of the laser diode. The laser diode also proved to be a valuable tool in investigating the operation of the conventional gas cell clock. Results concerning linewidths, the light shift effect and the effect of isotopic spin exchange in the conventional gas cell clock are reported.

Volk, C. H.

Cesium and rubidium frequency standards status and performance on the GPS program

This paper is an update of the on-orbit operational performance of the frequency standards on the Block I GPS 8 to 11 Navstar satellites, the Block II GPS 13 to 21 Navstar satellites and the Block IIA GPS 22 to 40 Navstar satellites. A brief history of the frequency standards depicting improvements incorporated in the GPS Program with corresponding results will be presented. The frequency standards configurations from the start to the present, including the various Block IIA clock configurations will be discussed. Topics such as clock observations and long term trending analysis which could enhance on-orbit performance analysis will be covered.

Vanmelle, M. J.

Potassium Isotopic Compositions of NIST Potassium Standards and 40Ar/39Ar Mineral Standards

Knowledge of the isotopic ratios of standards, spikes, and reference materials is fundamental to the accuracy of many geochronological methods. For example, the 238U/235U ratio relevant to U-Pb geochronology was recently re-determined [1] and shown to differ significantly from the previously accepted value employed during age determinations. These underlying values are fundamental to accurate age calculations in many isotopic systems, and uncertainty in these values can represent a significant (and often unrecognized) portion of the uncertainty budget for determined ages. The potassium isotopic composition of mineral standards, or neutron flux monitors, is a critical, but often overlooked component in the calculation of K-Ar and 40Ar/39Ar ages. It is currently assumed that all terrestrial materials have abundances indistinguishable from that of NIST SRM 985 [2]; this is apparently a reasonable assumption at the 0.25per mille level (1σ) [3]. The 40Ar/39Ar method further relies on the assumption that standards and samples (including primary and secondary standards) have indistinguishable 40K/39K values. We will present data establishing the potassium isotopic compositions of NIST isotopic K SRM 985, elemental K SRM 999b, and 40Ar/39Ar biotite mineral standard GA1550 (sample MD-2). Stable isotopic compositions (41K/39K) were measured by the peak shoulder method with high resolution MC-ICP-MS (Thermo Scientific NEPTUNE Plus), using the accepted value of NIST isotopic SRM 985 [2] for fractionation [4] corrections [5]. 40K abundances were measured by TIMS (Thermo Scientific TRITON), using 41K/39K values from ICP-MS measurements (or, for SRM 985, values from [2]) for internal fractionation corrections. Collectively these data represent an important step towards a metrologically traceable calibration of 40K concentrations in primary 40Ar/39Ar mineral standards and improve uncertainties by ca. an order of magnitude in the potassium isotopic compositions of standards.

Morgan, Leah

ACCESS: Design and Sub-System Performance

Establishing improved spectrophotometric standards is important for a broad range of missions and is relevant to many astrophysical problems. ACCESS, "Absolute Color Calibration Experiment for Standard Stars", is a series of rocket-borne sub-orbital missions and ground-based experiments designed to enable improvements in the precision of the astrophysical flux scale through the transfer of absolute laboratory detector standards from the National Institute of Standards and Technology (NIST) to a network of stellar standards with a calibration accuracy of 1% and a spectral resolving power of 500 across the 0.35 -1.7 micrometer bandpass.

Kaiser, Mary Elizabeth

Research Institute for Technical Careers

The NASA research grant to Wilberforce University enabled us to establish the Research Institute for Technical Careers (RITC) in order to improve the teaching of science and engineering at Wilberforce. The major components of the research grant are infrastructure development, establishment of the Wilberforce Intensive Summer Experience (WISE), and Joint Research Collaborations with NASA Scientists. (A) Infrastructure Development. The NASA grant has enabled us to improve the standard of our chemistry laboratory and establish the electronics, design, and robotics laboratories. These laboratories have significantly improved the level of instruction at Wilberforce University. (B) Wilberforce Intensive Summer Experience (WISE). The WISE program is a science and engineering bridge program for prefreshman students. It is an intensive academic experience designed to strengthen students' knowledge in mathematics, science, engineering, computing skills, and writing. (C) Joint Collaboration. Another feature of the grant is research collaborations between NASA Scientists and Wilberforce University Scientists. These collaborations have enabled our faculty and students to conduct research at NASA Lewis during the summer and publish research findings in various journals and scientific proceedings.

Glenn, Ronald L.

OCI Geolocation Evaluation and Refinement Using Landsat Control Points

The Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission is NASA’s next investment in ocean biology, clouds, and aerosol data records. A key feature of PACE is the inclusion of an advanced satellite radiometer, Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. The geolocation processing is performed for OCI using spacecraft navigation data and an instrument geometry model. To evaluate the geolocation accuracy for OCI and develop refinements to the processing methods, control point matching using Landsat data has been implemented as a step in the operational processing of OCI data at the Science Data Segment. This processing provides between 200 and 300 high-quality matchups per day with good global and geometric distribution, allowing rapid evaluation of the OCI geolocation accuracy. The results provided an early indication of the overall quality of the geolocation processing and of specific aspects needing improvement. A standard set of granules was identified to support rapid implementation and testing of geolocation refinements, and this approach has been highly successful in improving the geolocation processing accuracy to meet the science requirements. The evaluation will continue throughout the mission to ensure the ongoing accuracy of geolocation. This paper describes the control point matching methodology, the approach to development of the geolocation processing refinements, and the recent results.

PACE

OCI Geolocation Evaluation and Refinement Using Landsat Control Points

The Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission is NASA’s next investment in ocean biology, clouds, and aerosol data records. A key feature of PACE is the inclusion of an advanced satellite radiometer, Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. The geolocation processing is performed for OCI using spacecraft navigation data and an instrument geometry model. To evaluate the geolocation accuracy for OCI and develop refinements to the processing methods, control point matching using Landsat data has been implemented as a step in the operational processing of OCI data at the Science Data Segment. This processing provides between 200 and 300 high-quality matchups per day with good global and geometric distribution, allowing rapid evaluation of the OCI geolocation accuracy. The results provided an early indication of the overall quality of the geolocation processing and of specific aspects needing improvement. A standard set of granules was identified to support rapid implementation and testing of geolocation refinements, and this approach has been highly successful in improving the geolocation processing accuracy to meet the science requirements. The evaluation will continue throughout the mission to ensure the ongoing accuracy of geolocation. This paper describes the control point matching methodology, the approach to development of the geolocation processing refinements, and the recent results.

PACE