Search NASA⌕ Search

SEARCH · Search NASA

Results for “in situ analytics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The New NASA Orbital Debris Engineering Model ORDEM2000

The NASA Orbital Debris Program Office at Johnson Space Center has developed a new computer-based orbital debris engineering model, ORDEM2000, which describes the orbital debris environment in the low Earth orbit region between 200 and 2000 km altitude. The model is appropriate for those engineering solutions requiring knowledge and estimates of the orbital debris environment (debris spatial density, flux, etc.). ORDEM2000 can also be used as a benchmark for ground-based debris measurements and observations. We incorporated a large set of observational data, covering the object size range from 10 mm to 10 m, into the ORDEM2000 debris database, utilizing a maximum likelihood estimator to convert observations into debris population probability distribution functions. These functions then form the basis of debris populations. We developed a finite element model to process the debris populations to form the debris environment. A more capable input and output structure and a user-friendly graphical user interface are also implemented in the model. ORDEM2000 has been subjected to a significant verification and validation effort. This document describes ORDEM2000, which supersedes the previous model, ORDEM96. The availability of new sensor and in situ data, as well as new analytical techniques, has enabled the construction of this new model. Section 1 describes the general requirements and scope of an engineering model. Data analyses and the theoretical formulation of the model are described in Sections 2 and 3. Section 4 describes the verification and validation effort and the sensitivity and uncertainty analyses. Finally, Section 5 describes the graphical user interface, software installation, and test cases for the user.

Liou, Jer-Chyi↗

Inference of Ice Cloud Properties from High-spectral Resolution Infrared Observations

The theoretical basis is explored for inferring the microphysical properties of ice crystal from high-spectral resolution infrared observations. A radiative transfer model is employed to simulate spectral radiances to address relevant issues. The extinction and absorption efficiencies of individual ice crystals, assumed as hexagonal columns for large particles and droxtals for small particles, are computed from a combination of the finite- difference time-domain (FDTD) technique and a composite method. The corresponding phase functions are computed from a combination of FDTD and an improved geometric optics method (IGOM). Bulk scattering properties are derived by averaging the single- scattering properties of individual particles for 30 particle size distributions developed from in situ measurements and for additional four analytical Gamma size distributions for small particles. The non-sphericity of ice crystals is shown to have a significant impact on the radiative signatures in the infrared (IR) spectrum; the spherical particle approximation for inferring ice cloud properties may result in an overest&ation of the optical thickness and an inaccurate retrieval of effective particle size. Furthermore, we show that the error associated with the use of the Henyey-Greenstein phase function can be as larger as 1 K in terms of brightness temperature for larger particle effective size at some strong scattering wavenumbers. For small particles, the difference between the two phase functions is much less, with brightness temperatures generally differing by less than 0.4 K. The simulations undertaken in this study show that the slope of the IR brightness temperature spectrum between 790-960/cm is sensitive to the effective particle size. Furthermore, a strong sensitivity of IR brightness temperature to cloud optical thickness is noted within the l050-1250/cm region. Based on this spectral feature, a technique is presented for the simultaneous retrieval of the visible optical thickness and effective particle size from high spectral resolution infrared data under ice cloudy con&tion. The error analysis shows that the uncertainty of the retrieved optical thickness and effective particle size has a small range of variation. The error for retrieving particle size in conjunction with an uncertainty of 5 K in cloud'temperature, or a surface temperature uncertainty of 2.5 K, is less than 15%. The corresponding e m r in the uncertainty of optical thickness is within 5-2096, depending on the value of cloud optical thickness. The applicability of the technique is demonstrated using the aircraft-based High- resolution Interferometer Sounder (HIS) data from the Subsonic Aircraft: Contrail and Cloud Effects Special Study (SUCCESS) in 1996 and the First ISCCP Regional Experiment - Arctic Clouds Experiment (FIRE-ACE) in 1998.

Huang, Hung-Lung↗

Compositions of Spherules and Rock Surfaces at Meridiani

The Alpha Particle X-ray Spectrometers (APXS) on the Mars Exploration Rovers (MER) have proven extremely valuable for analyzing rocks and soils on the surface of Mars. The precision of their compositional measurements has been shown to be phenomenal through analyses of the compositionally very uniform Meridiani soils. Through combined use of the rock abrasion tool (RAT) and the analytical instruments on the in-situ deployment device (IDD), analyses of the interiors of fine-grained and texturally uniform rocks with surfaces ground flat have been made under conditions that are nearly ideal for this mode of analysis. The APXS has also been used frequently to analyze materials whose characteristics, surface morphologies, and sample-detector geometries are less than ideal, but the analyses of which are nonetheless very useful for understanding the makeup of the target materials. Such targets include undisturbed rocks with irregular and sometimes coated surfaces and mixed targets such as soils that include fine-grained components as well as coarse grains and pieces of rocks. Such target materials include the well known hematite-rich concretions, referred to as blueberries because of their multispectral color, size, and mode of occurrence. In addition to non-ideal target geometry, such mixed materials also present a heterogeneous target in terms of density. These irregularities violate the assumptions commonly associated with analyses done in the laboratory to achieve the highest possible accuracy. Here we acknowledge the irregularities and we examine the inferences drawn from specific chemical trends obtained on imperfect targets in light of one of the potential pitfalls of natural materials on the surface of Mars, namely thin dust coatings.

Mittlefehldt, David W.↗

A Multispectral Micro-Imager for Lunar Field Geology

Field geologists routinely assign rocks to one of three basic petrogenetic categories (igneous, sedimentary or metamorphic) based on microtextural and mineralogical information acquired with a simple magnifying lens. Indeed, such observations often comprise the core of interpretations of geological processes and history. The Multispectral Microscopic Imager (MMI) uses multi-wavelength, light-emitting diodes (LEDs) and a substrate-removed InGaAs focal-plane array to create multispectral, microscale reflectance images of geological samples (FOV 32 X 40 mm). Each pixel (62.5 microns) of an image is comprised of 21 spectral bands that extend from 470 to 1750 nm, enabling the discrimination of a wide variety of rock-forming minerals, especially Fe-bearing phases. MMI images provide crucial context information for in situ robotic analyses using other onboard analytical instruments (e.g. XRD), or for the selection of return samples for analysis in terrestrial labs. To further assess the value of the MMI as a tool for lunar exploration, we used a field-portable, tripod-mounted version of the MMI to image a variety of Apollo samples housed at the Lunar Experiment Laboratory, NASA s Johnson Space Center. MMI images faithfully resolved the microtextural features of samples, while the application of ENVI-based spectral end member mapping methods revealed the distribution of Fe-bearing mineral phases (olivine, pyroxene and magnetite), along with plagioclase feldspars within samples. Samples included a broad range of lithologies and grain sizes. Our MMI-based petrogenetic interpretations compared favorably with thin section-based descriptions published in the Lunar Sample Compendium, revealing the value of MMI images for astronaut and rover-mediated lunar exploration.

Nunez, Jorge↗

In Situ Analysis of Organics with a Portable Mass Spectrometer

The search for extra-terrestrial life starts at home. In order to find life on other planets, we start by examining life processes we understand on the earth. Though it may not be possible to see the life in the form of macroscopic organisms, telltale signs of life can exist in the form of small organic molecules such as peptides and amino acids. Our overall goal is to test a portable mass spectrometer (MS) system, the Mini 10.5, for astrobiological applications including in situ hydrocarbon analysis and sediments analysis using an additional automated sample processing system (ASPS). The collaborative research focuses on two current projects in the field of astrobiology. Both projects are geared towards examining organics distributed in extreme environments. One portion of study attempts to qualitatively analyze the effect of volatile organic compounds (VOC) produced by diesel exhaust on lichens growing in the desert. This requires measurements to be taken by bringing the instrument to the Mojave Desert and monitoring atmospheric composition of VOCs in situ. The second project is to evaluate the miniature MS system as a detector for the ASPS extraction system. A major obstacle of any chemometric in situ analysis is the suppression of analyte signal by concomitant signal from the surrounding environment. The ASPS extraction device has been developed at JPL to extract amino acids from sediment samples and elute them in solution. The solution is eluted at a high pH and needs to be conditioned to a more neutral pH so that dissolved amino acids can be readily protonated and subsequently analyzed by electrospray MS.

astrobiology↗

Redeployable Sensor Probe for In-Situ Lunar Resource Mapping from Small Landers

The use of in-situ resources in lunar regolith for production of propellant, life support, and construction (e.g. polar water ice, hydrogen, helium-3, and regolith minerals) will enable sustainable robotic and human space exploration and pave the way for commercialization of lunar exploration. Currently, the search for and characterization of resources on the Moon uses orbital datasets and local geological and geophysical surveys to map and characterize potential deposits. To develop efficient ISRU systems, it is essential to find, characterize, and map lunar resources in-situ, at local scales, using deployable, analytical payloads. We have developed a 3 kg, TRL4 scientific payload, MoonSHOT (Moon Subsurface Hydrogen Optical Tool), to characterize and map lunar resources from a small lander or rover.

Sobron, P.↗

Enumeration and Fluorescence In Situ Hybridization of Microbial Bioburden on Cleanroom Surfaces

Introduction: Microorganisms are everywhere on Earth, even in the cleanest of places. Spacecraft assembly cleanrooms can harbor low levels of living and dead microbial cells (e.g., [1,2]), and cleanroom bioburden can also include organic molecules from industrial sources and in situ biomass. Life detection missions require careful attention to avoid contaminants that can be easily convoluted with analytical targets. We are evaluating epifluorescent microscopy and fluorescence in situ hybridization (FISH) as methods to complement organic contamination detection techniques. Epifluorescent cell counting offers an accurate and cost-effective way to quantify low levels of surface biomass. FISH could allow for the identification of residual organisms, and can be targeted to detect active populations of specific organisms such as bacteria known to resist cleaning procedures. This effort is part of a larger study that is concentrated on characterizing the surface and airborne molecular organic contamination background in Johnson Space Center (JSC) Astromaterials curation laboratories and Goddard Space Flight Center (GSFC) spacecraft assembly rooms, and understanding contaminants in the context of cleaning procedures and residual bioburden. Methods: Samples were collected by swabbing surfaces in ISO 5 and ISO 7 equivalent cleanrooms at JSC. Swabs for FISH were fixed in 4% paraformaldehyde (PFA) for 3 hours and then stored in 1:1 ethanol:PBS, while swabs for cell counting were stored in 4% PFA until analysis to avoid any cell loss during centrifugation that could impact quantification of very low biomass samples. Cell counting was performed with SYBR Gold as in [3], but adapted for very low biomass. FISH was performed as in [4], using DAPI as a counterstain for all DNA-containing cells. Negative controls included wells with no probe applied, to test for natural fluorescence, as well as the nonsense probe NONEUB (reverse complement of EUB338) to evaluate non-specific probe binding. Results and Discussion: Cleanroom surfaces had 102-103 cells cm-2. The extremely low biomass of these samples was challenging for enumeration, and required careful and routine use of “field” and laboratory blanks. FISH was performed with the general archaeal and bacterial probes ARCH915 and EUB338 (EUBMIX, [4]), probe GAMBET ([4]), and PSE227, which targets the genus Pseudomonas [5]). The latter two probes were selected because Pseudomonas spp. and other Gammaproteobacteria have not been isolated from cleanroom surfaces but do appear frequently in rRNA gene libraries from these surfaces. While some active bacteria were identified (Fig. 1c), most cells detectable by DAPI did not have a strong or any fluorescent signal (e.g., Fig. 1d), indicating that the vast majority of cells are dead or inactive. This suggests that cleaning protocols are effective at inactivating microbial contaminants, but that dead or inactive cells can remain on surfaces. Cells were often clumped in a weakly autofluorescent matrix, possibly biofilm material (Fig. 1c,d). We also observed other particulate material that was collected by the swabs, including apparent textile fibers (Fig. 1b). Our results are consistent with other studies that show that the bioburden present in clean rooms includes active, dormant, and dead cells. We will discuss how FISH and epifluorescent cell counting could be applied in planetary protection protocols, including the advantages and disadvantages of FISH and cell counting for routine use, as well as different possible applications for more specialized FISH procedures. References: [1] Moissl-Eichinger et al. (2015) Sci Rep, 5, 9156 [2] Hendrickson et al. (2021) Microbiome, 9, 238 [3] Jones et al. (2017) Appl Environ Microbiol, 83, e00909-17 [4] Jones et al. (2015) Appl Environ Microbiol, 81, 1242-1250. [5] Watt et al. (2006) Environ Microbiol, 8, 871-884

C J Huff↗

Probing the Composition of Primitive Solar System Materials with a Compact Laser Mass Spectrometer

To contribute to and complement our understanding of the processes governing the formation,distribution, and evolution of primitive materials throughout the solar system, it will be critical toform connections between broad remote sensing spectroscopic surveys, laboratorymeasurements of analogs and samples delivered to Earth, and in situ measurements of thesurface composition on future primitive body missions. Recently, a laboratory prototypeemploying resonance two-step laser mass spectrometry [Getty et al., 2012] has been coupledto a cryogenic sample stage to enable measurements of analog samples that are relevant tothese fundamental questions. Analyses of mineral-aromatic mixtures and meteorite powderswill be presented. Our goals are twofold: (1) to conduct laboratory studies on solar systemanalog, meteoritic, and potentially returned samples to elucidate composition, and (2) toprovide a compact but capable analytical instrument for discovery-driven in situ interrogationof surface chemistry on a future mission, such as to a Trojan asteroid, comet, or icy moon.

Getty, Stephanie A.↗

Feasibility of remote sensing for detecting thermal pollution. Part 1: Feasibility study. Part 2: Implementation plan

A feasibility study for the development of a three-dimensional generalized, predictive, analytical model involving remote sensing, in-situ measurements, and an active system to remotely measure turbidity is presented. An implementation plan for the development of the three-dimensional model and for the application of remote sensing of temperature and turbidity measurements is outlined.

Veziroglu, T. N.↗

On-Chip Microfluidic Components for In Situ Analysis, Separation, and Detection of Amino Acids

The Astrobiology Analytical Laboratory at GSFC has identified amino acids in meteorites and returned cometary samples by using liquid chromatography-electrospray ionization time-of-flight mass spectrometry (LCMS). These organic species are key markers for life, having the property of chirality that can be used to distinguish biological from non-biological amino acids. One of the critical components in the benchtop instrument is liquid chromatography (LC) analytical column. The commercial LC analytical column is an over- 250-mm-long and 4.6-mm-diameter stainless steel tube filled with functionized microbeads as stationary phase to separate the molecular species based on their chemistry. Miniaturization of this technique for spaceflight is compelling for future payloads for landed missions targeting astrobiology objectives. A commercial liquid chromatography analytical column consists of an inert cylindrical tube filled with a stationary phase, i.e., microbeads, that has been functionalized with a targeted chemistry. When analyte is sent through the column by a pressurized carrier fluid (typically a methanol/ water mixture), compounds are separated in time due to differences in chemical interactions with the stationary phase. Different species of analyte molecules will interact more strongly with the column chemistry, and will therefore take longer to traverse the column. In this way, the column will separate molecular species based on their chemistry. A lab-on-chip liquid analysis tool was developed. The microfluidic analytical column is capable of chromatographically separating biologically relevant classes of molecules based on their chemistry. For this analytical column, fabrication, low leak rate, and stationary phase incorporation of a serpentine microchannel were demonstrated that mimic the dimensions of a commercial LC column within a 5 10 1 mm chip. The microchannel in the chip has a 75- micrometer-diameter oval-shaped cross section. The serpentine microchannel has four different lengths: 40, 60, 80, and 100 mm. Functionized microbeads were filled inside the microchannel to separate molecular species based on their chemistry.

Zheng, Yun↗

Detecting Organic Compounds in Martian Soil Analogues Using Gas Chromatography Mass Spectrometry

One of the primary objectives of the 1976 Viking missions was to determine whether organic compounds, possibly of biological origin, were present in the Martian surface soils. The Viking gas chromatography mass spectrometry (GCMS) instruments found no evidence for any organic compounds of Martian origin above a few parts per billion in the upper 10 cm of surface soil [l], suggesting the absence of a widely distributed Martian biota. However, Benner et d. have suggested that significant amounts of non-volatile organic compounds, possibly including oxidation products of bioorganic molecules (e.g. carboxylic acids) would not have been detected by the Viking GCMS [2]. Moreover, other key organic compounds important to biology, such as amino acids and nucleobases, would also likely have been missed by the Viking GCMS as these compounds require chemical derivatization to be stable in a GC column [3]. Recent pyrolysis experiments with a Mars soil analogue that had been innoculated with Escherichia coli bacteria have shown that amino acid decomposition products (amines) and nucleobases are among the most abundant products generated after pyrolysis of the bacterial cells [4,5]. At the part per billion level (Viking GCMS detection limit), these pyrolysis products generated from several million bacterial cells per gram of Martian soil would not have been detected by the Viking GCMS instruments [4]. Analytical protocols are under development for upcoming in situ lander opportunities to target several important biological compounds including amino acids and nucleobases. For example, extraction and chemical derivatization techniques [3] are being adapted for space flight use to transform reactive or fragile molecules that would not have been detected by the Viking GCMS instruments, into species that are sufficiently volatile to be detected by GCMS. Recent experiments carried out at NASA Goddard have shown that using this derivatization technique all of the targeted compounds mentioned above can be separated on a GC column and detected by MS at sub-picomole (< 10(exp -l2 mole) levels. With these methods, the detection limit for amino acids, carboxylic acids and nucleobases is several orders of magnitude more sensitive than the Viking GCMS instruments for these compounds. Preliminary results using this analytical technique on a variety of Martian soil analogues will be presented.

Glavin, D. P.↗

Production of global sea surface temperature fields for the Jet Propulsion Laboratory workshop comparisons

Sea surface temperature (SST) is measured from space by the advanced very high resolution radiometer (AVHRR), scanning multichannel microwave radiometer (SMMR), high resolution infrared sounder (HIRS) and VISSR atmospheric sounder (VAS). Typical accuracies have been reported from 0.5 C regionally to 2.0 C on a global basis. To evaluate the accuracy of the satellite-derived sea surface temperatures, a series of three workshops was organized to provide uniform data reduction and analysis. The analytical techniques used to intercompare satellite and in situ measurements are described in detail. Selected results showed the overall average rms errors were in the range 0.5-1.0 C.

Hilland, J. E.↗

Utilization of the Generalized Method of Cells to Analyze the Deformation Response of Laminated Ceramic Matrix Composites

In order to practically utilize ceramic matrix composites in aircraft engine components, robust analysis tools are required that can simulate the material response in a computationally efficient manner. The MAC/GMC software developed at NASA Glenn Research Center, based on the Generalized Method of Cells micromechanics method, has the potential to meet this need. Utilizing MAC/GMC, the effective stiffness properties, proportional limit stress and ultimate strength can be predicted based on the properties and response of the individual constituents. In this paper, the effective stiffness and strength properties for a representative laminated ceramic matrix composite with a large diameter fiber are predicted for a variety of fiber orientation angles and laminate orientations. As part of the analytical study, methods to determine the in-situ stiffness and strength properties of the constituents required to appropriately simulate the effective composite response are developed. The stiffness properties of the representative composite have been adequately predicted for all of the fiber orientations and laminate configurations examined in this study. The proportional limit stresses and strains and ultimate stresses and strains were predicted with varying levels of accuracy, depending on the laminate orientation. However, for the cases where the predictions did not have the desired level of accuracy, the specific issues related to the micromechanics theory were identified which could lead to difficulties that were encountered that could be addressed in future work.

Goldberg, Robert K.↗

Evidence for Smectite Clays from MSL SAM Analyses of Mudstone at Yellowknife Bay, Gale Crater, Mars

Drilled samples of mudstone from the Sheepbed unit at Yellowknife Bay were analyzed by MSL instruments including the Sample Analysis at Mars (SAM) and Chemistry and Mineralogy (CheMin) instruments in MSL's Analytical Laboratory. CheMin analyses revealed the first in situ X-ray diffraction based evidence of clay minerals on Mars, which are likely trioctahedral smectites (e.g., saponite) and comprise approx 20% of the mudstone sample (e.g., Bristow et al., this meeting). SAM analyses, which heated the mudstone samples to 1000 C and monitored volatiles evolved to perform in situ evolved gas analysis mass spectrometry (EGA-MS), resulted in a H2O trace exhibiting a wide evolution at temperatures < 500 C, and an evolution peak at higher temperatures near approx 750 C. The low temperature H2O evolution has many potential contributors, including adsorbed H2O, smectite interlayer H2O, and structural H2O/OH from bassanite and akaganeite (identified by CheMin) and H2O/OH from amorphous phases in the sample. The high temperature H2O is consistent with the evolution of H2O from the dehydroxylation of the smectite clay mineral. Comparison to EGA-MS data collected under SAM-like conditions on a variety of clay mineral reference materials indicate that a trioctahedral smectite, such as saponite, is most consistent with the high temperature H2O evolution observed. There may also be SAM EGA-MS evidence for a small high temperature H2O evolution from scoop samples from the Yellowknife Bay Rocknest sand shadow bedform. As in the mudstone samples, this evolution may indicate the detection of smectite clays, and the idea that minor clays may be present in Rocknest materials that could be expected to be at least partially derived from local sources is reasonable. But, because smectite clays were not definitively observed in CheMin analyses of Rocknest materials, they must be present at much lower abundances than the approx 20% observed in the mudstone samples. This potential detection underscores the complementary nature of the MSL CheMin and SAM instruments for investigations of martian sample mineralogy. Information on the nature of Yellowknife Bay clay minerals may also be available from the detection of H2 evolved during SAM EGA-MS at high temperature. A likely source of at least some of this H2 is H2O evolved from the smectite clays at high temperature, and it is possible these evolutions can be used in a similar fashion to high temperature H2O releases to provide constraints on the clay minerals in a sample. In addition, the D/H of this high temperature H2, as well as the H2O, can be derived from SAM MS and Tunable Laser Spectrometer (TLS) data, respectively. These D/H values may help to inform the provenance of high and low temperature water evolved from martian samples

McAdam, Amy↗

NIAC Phase 1 Final Study Report on Titan Aerial Daughtercraft

Saturns giant moon Titan has become one of the most fascinating bodies in the Solar System. Even though it is a billion miles from Earth, data from the Cassini mission reveals that Titan has a very diverse, Earth-like surface, with mountains, fluvial channels, lakes, evaporite basins, plains, dunes, and seas [Lopes 2010] (Figure 1). But unlike Earth, Titans surface likely is composed of organic chemistry products derived from complex atmospheric photochemistry [Lorenz 2008]. In addition, Titan has an active meteorological system with observed storms and precipitation-induced surface darkening suggesting a hydrocarbon cycle analogous to Earths water cycle [Turtle 2011].Titan is the richest laboratory in the solar system for studying prebiotic chemistry, which makes studying its chemistry from the surface and in the atmosphere one of the most important objectives in planetary science [Decadal 2011]. The diversity of surface features on Titan related to organic solids and liquids makes long-range mobility with surface access important [Decadal 2011]. This has not been possible to date, because mission concepts have had either no mobility (landers), no surface access (balloons and airplanes), or low maturity, high risk, and/or high development costs for this environment (e,g. large, self-sufficient, long-duration helicopters). Enabling in situ mobility could revolutionize Titan exploration, similarly to the way rovers revolutionized Mars exploration. Recent progress on several fronts has suggested that small-scale rotorcraft deployed as daughtercraft from a lander or balloon mothercraft may be an effective, affordable approach to expanding Titan surface access. This includes rapid progress on autonomous navigation capabilities of such aircraft for terrestrial applications and on miniaturization, driven by the consumer mobile electronics market, of high performance of sensors, processors, and other avionics components needed for such aircraft. Chemical analysis, for example with a mass spectrometer, will be important to any Titan surface mission. Anticipating that it may be more practical to host chemical analysis instruments on a mothership than a daughtercraft, we defined system and mission concepts that deploy a small rotorcraft, termed a Titan Aerial Daughtercraft (TAD), from a lander or balloon to perform high-resolution imaging and mapping, potentially land to acquire microscopic images or other in situ measurements, and acquire samples to return to analytical instruments on the mothership. In principle, the ability to recharge batteries in TAD from a radioisotope or other long-lived power source on the mothership could enable multiple sorties. For a lander-based mission, a variety of landing sites is conceivable, including near lake margins, in dry lake beds, or in regions of plains, dunes, or putative cryovolanic or impact melt features. Such missions may require landing with greater precision than in previous missions (Huygens) and mission studies; this could also enhance the ability of TAD to reach interesting terrain from the landing site. Precision descent may also benefit balloon missions, with or without a daughtercraft, by increasing the probability that the balloon will drift over desired terrain early in its mission. Given these potential benefits, the overall concept studied here includes brief consideration of precision descent for landing or balloon deployment, followed by one or more sorties by a rotorcraft deployed from the mothership, with the ability to return to the mothership.

Saturn↗

Grossite-Rich Refractory Inclusions in Carbonaceous Chondrites: Evidence for Early Generation of Different O-Isotope Reservoirs in the Protoplanetary Disk and O-Isotope Exchange During Fluid-Rock Interaction

The oxygen isotopic composition of the Sun inferred from the measurements of the solar wind returned by the Genesis spacecraft is O-16-enriched (△O-17 = -28.4±3.6‰) relative to the whole-rock O-isotope compositions of chondrites and achondrites, and chondrule phenocrysts, which all plot close to the terrestrial fractionation line (△O-17 ∼ ±5‰). Vast majority of refractory inclusions (CAIs and AOAs) in carbonaceous chondrites of petrologic types 2-3.0 are iso-topically uniform and have solar-like △O-17. In contrast, CAIs and AOAs in metamorphosed CV and CO chondrites are isotopically heterogeneous with melilite, anorthite, perovskite, Zr- and Sc-rich oxides and silicates, and occasionally Al, Ti-diopside being O-16-depleted relative to hibonite, spinel, Al-diopside, and forsterite. The timing of generation of different O-isotope reservoirs and the nature of O-isotope heterogeneity in refractory inclusions in CO3 and CV3 chondrites are poorly known. Grossite (CaAl4O7) is one of the first minerals predicted to condense from a gas of solar composition and therefore it could have recorded isotopic compositions of reservoirs during the earliest stages of the Solar System evolution. Here we report on O-isotope compositions of grossite-rich CAIs in CH3 and CO3 chondrites measured in situ with the UH Cameca ims-1280. For analytical procedures see [9].

A N Krot↗

The growth and in situ characterization of chemical vapor deposited SiO2

This paper reports the results of studies of the kinetics of remote (indirect) plasma enhanced low pressure CVD growth of SiO2 on Si and InP and of the in situ characterization of the electrical surface properties of InP during CVD processing. In the latter case photoluminescence was employed as a convenient and sensitive noninvasive method for characterizing surface trap densities. It was determined that, provided certain precautions are taken, the growth of SiO2 occurs in a reproducible and systematic fashion that can be expressed in an analytic form useful for growth rate prediction. Moreover, the in situ photoluminescence studies have yielded information on sample degradation resulting from heating and chemical exposure during the CVD growth.

Iyer, R.↗

Moisture Content and Migration Dynamics in Unsaturated Porous Media

Fundamental studies of fluid mechanics and transport in partially saturated soils are presented. Solution of transient diffusion problems in support of the development of probes for the in-situ measurement of moisture content is given. Numerical and analytical methods are used to study the fundamental problem of meniscus and saturation front propagation in geometric models of porous media.