Search NASA⌕ Search

SEARCH · Search NASA

Results for “incident angle modifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Internal photoemission in Ag-Al2O3-Al junctions

The magnitude of the photon-induced current in Ag-Al2O3-Al metal-oxide-metal junctions has been studied as a function of photon energy and angle of incident radiation. Photocurrents were theoretically analyzed on the basis of a modified vacuum photoemission model (Jain, 1975; Slayman et al., to be published). Optical constants previously reported in the literature (Irani et al., 1971; Ehnrereich et al., 1963) were used to calculate the true spatial generation rate in Ag and Al as a function of the angle, polarization of incident radiation, and film thickness. Results were found to be in very good agreement with experimentally determined values for a tunable dye laser with a KDP doubling crystal pumped by a Q-switched Nd:YAG laser with a LiIO3 doubling crystal. The system provided risetimes of 50 ns or less and peak powers of 10 W. Under short circuit conditions, the photoresponse to incident power was linear up to available power densities of 10 kW/sq cm. Quantum efficiencies of about 0.1% at zero-bias, near 3.8 eV under P polarization, were typically observed.

Guedes, J. M. P.↗

Whole-Cell Scan using Automatic Variable-Angle and Variable-Illumination-Depth Pseudo—Total Internal Reflection Fluorescence Microscopy

An automatic calibration and angle-scanning prism-type total internal reflection fluorescence microscope (TIRFM) was modified to function in both TIRFM and pseudo-TIRFM modes. When the incident angle of the excitation laser beam was controlled to be larger than the critical angle, the instrument served as a variable-angle TIRFM. A homemade computer program automatically calibrates the laser illumination spot in the sample to overlap with the center of the microscope's field of view. Then, by measuring the fluorescence intensities at different incident angles, the z-positions of fluorescent nanospheres close to the cell basolateral membrane can be extracted. When the incident angle is reduced to be in the subcritical range, the instrument works as a pseudo-TIRFM. The whole cell body from bottom to top can be imaged in a vertical scan process. Furthermore, the illumination field depth in the pseudo-TIRFM can be controlled by changing the incident angle or the horizontal position of the laser spot.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crystallization of nanopore-confined imidazolium ionic liquids probed by temperature-resolved in situ grazing-incidence wide angle X-ray scattering (GIWAXS)

The crystallization behavior of ionic liquids (ILs) 1-butyl-3-methylimidazolium [BMIM] hexafluorophosphate [PF 6 ] and chloride [Cl] is investigated upon confinement in 2.3 or 8.2 nm diameter silica nanopore arrays, along with the effects of covalently modifying the pore walls with 1-(3-trimethoxysilylpropyl)3-methylimidazolium [TMS-MIM] + groups. In situ grazing-incidence wide angle x-ray scattering (GIWAXS) is performed during heating from as low as -110 °C to room temperature. Partially ordered “nanodomains” are observed in both ILs in the bulk molten state, but they are disrupted by nanoconfinement. Melting point depression consistent with capillary effects is observed for [BMIM][PF 6 ] in 2.3 nm pores. However, the melting point is elevated for [BMIM][PF 6 ] in 8.2 nm pores, which provide sufficient space to stabilize the crystalline phase. For [BMIM][Cl], crystallization is observed only in 8.2 nm bare silica pores, but the melting point is severely depressed. Tethering with IL-like [TMS-MIM + ] also promotes the crystallization of [BMIM][PF 6 ], resulting in elevated melting points. The combined effects of a larger pore size and pore surface tethering on [BMIM][PF 6 ] result in a single stable crystal phase that persists from -140 °C to 25 °C (vs. the bulk melting point of -11 °C). These results show that when ILs are used in confined systems, complex crystallization behavior can emerge depending on the counterion, pore size, and surface modification that require consideration of ion layering in the confined space in addition to surface free energy effects.

He, Yuxin [University of Kentucky, Lexington, KY (↗

Dynamic stability characteristics of the combination space shuttle orbiter and ferry vehicle

Subsonic forced-oscillation tests of a 0.015 scale model of the space shuttle orbiter/747 ferry vehicle were conducted in the Langley high speed 7- by 10-foot tunnel at Mach numbers of 0.2, 0.4, and 0.5 for angles of attack up to 12 deg. Tests were made of the basic 747 airplane, of the modified 747 (tip fins and struts added), of the ferry configuration, (747 plus orbiter at an incidence angle of 3 deg), and of the approach and landing test configuration (747 plus orbiter at an incidence angle of 6 deg).

Freeman, D. C., Jr.↗

Developing new optical imaging techniques for single particle and molecule tracking in live cells

Differential interference contrast (DIC) microscopy is a far-field as well as wide-field optical imaging technique. Since it is non-invasive and requires no sample staining, DIC microscopy is suitable for tracking the motion of target molecules in live cells without interfering their functions. In addition, high numerical aperture objectives and condensers can be used in DIC microscopy. The depth of focus of DIC is shallow, which gives DIC much better optical sectioning ability than those of phase contrast and dark field microscopies. In this work, DIC was utilized to study dynamic biological processes including endocytosis and intracellular transport in live cells. The suitability of DIC microscopy for single particle tracking in live cells was first demonstrated by using DIC to monitor the entire endocytosis process of one mesoporous silica nanoparticle (MSN) into a live mammalian cell. By taking advantage of the optical sectioning ability of DIC, we recorded the depth profile of the MSN during the endocytosis process. The shape change around the nanoparticle due to the formation of a vesicle was also captured. DIC microscopy was further modified that the sample can be illuminated and imaged at two wavelengths simultaneously. By using the new technique, noble metal nanoparticles with different shapes and sizes were selectively imaged. Among all the examined metal nanoparticles, gold nanoparticles in rod shapes were found to be especially useful. Due to their anisotropic optical properties, gold nanorods showed as diffraction-limited spots with disproportionate bright and dark parts that are strongly dependent on their orientation in the 3D space. Gold nanorods were developed as orientation nanoprobes and were successfully used to report the self-rotation of gliding microtubules on kinesin coated substrates. Gold nanorods were further used to study the rotational motions of cargoes during the endocytosis and intracellular transport processes in live mammalian cells. New rotational information was obtained: (1) during endocytosis, cargoes lost their rotation freedom at the late stage of internalization; (2) cargoes performed train-like motion when they were transported along the microtubule network by motor proteins inside live cells; (3) During the pause stage of fast axonal transport, cargoes were still bound to the microtubule tracks by motor proteins. Total internal reflection fluorescence microscopy (TIRFM) is another non-invasive and far-field optical imaging technique. Because of its near-field illumination mechanism, TIRFM has better axial resolution than epi-fluorescence microscopy and confocal microscopy. In this work, an auto-calibrated, prism type, angle-scanning TIRFM instrument was built. The incident angle can range from subcritical angles to nearly 90°, with an angle interval less than 0.2°. The angle precision of the new instrument was demonstrated through the finding of the surface plasmon resonance (SPR) angle of metal film coated glass slide. The new instrument improved significantly the precision in determining the axial position. As a result, the best obtained axial resolution was ~ 8 nm, which is better than current existing instruments similar in function. The instrument was further modified to function as a pseudo TIRF microscope. The illumination depth can be controlled by changing the incident angle of the excitation laser beam or adjusting the horizontal position of the illumination laser spot on the prism top surface. With the new technique, i.e., variable-illumination-depth pseudo TIRF microscopy, the whole cell body from bottom to top was scanned.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transient superconductivity without superconductivity

Recent experiments on K 3 C 60 and layered copper-oxide materials have reported substantial changes in the optical response following application of an intense THz pulse. These data have been interpreted as the stimulation of a transient superconducting state even at temperatures well above the equilibrium transition temperature. We propose an alternative phenomenology based on the assumption that the pulse creates a nonsuperconducting, though nonequilibrium, situation in which the linear response conductivity is negative. The negative conductivity implies that the spatially uniform prepulse state is unstable and evolves to a new state with a spontaneous electric polarization. Furthermore, this state exhibits coupled oscillations of entropy and electric charge whose coupling to incident probe radiation modifies the reflectivity, leading to an apparently superconductinglike response that resembles the data. Dependencies of the reflectivity on polarization and angle of incidence of the probe are predicted and other experimental consequences are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The role of incidence angle in the laser ablation of a planar target

The effect of the laser ray incidence angle on the mass ablation rate and ablation pressure of planar inertial confinement fusion (ICF) targets is explored. In this work, a modified version of the textbook model of laser ablation is used to demonstrate that the mass ablation rate and ablation pressure scale with the 4/3 and 2/3 power of the cosine of the laser ray incidence angle relative to the target normal. Using an idealized planar model of ablation, it is demonstrated that constant irradiance is insufficient to produce similar velocities of a target when comparing cases driven at different incidence angles. Additionally, the effect of the incidence angle on the absorption fraction is demonstrated and it is shown that a longer duration is needed to achieve maximum absorption for greater angles. This further affects the mass ablation rate and ablation pressure in the first nanosecond of ablation. Here these results, when extrapolated, may provide insight into the variation of drive conditions encountered due to incidence in polar direct drive ICF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Manipulation of the graphene surface potential by ion irradiation

We show that the work function of exfoliated single layer graphene can be modified by irradiation with swift (E{sub kin}=92 MeV) heavy ions under glancing angles of incidence. Upon ion impact individual surface tracks are created in graphene on silicon carbide. Due to the very localized energy deposition characteristic for ions in this energy range, the surface area which is structurally altered is limited to Almost-Equal-To 0.01 {mu}m{sup 2} per track. Kelvin probe force microscopy reveals that those surface tracks consist of electronically modified material and that a few tracks suffice to shift the surface potential of the whole single layer flake by Almost-Equal-To 400 meV. Thus, the irradiation turns the initially n-doped graphene into p-doped graphene with a hole density of 8.5 Multiplication-Sign 10{sup 12} holes/cm{sup 2}. This doping effect persists even after heating the irradiated samples to 500 Degree-Sign C. Therefore, this charge transfer is not due to adsorbates but must instead be attributed to implanted atoms. The method presented here opens up a way to efficiently manipulate the charge carrier concentration of graphene.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Outdoor flat-plate collector performance prediction from solar simulator test data

Solar collector performance data obtained from tests with a simulator was modified for real-life conditions. The data obtained with the simulator was corrected for the variable conditions of ambient temperature, wind, incident angle, flow rate, etc., that are encountered outdoors. Modification of simulator data was accomplished by combining experiment with theory. The technique was demonstrated by application to a spectrally selective and a nonselective type of collector. This kind of modified simulator collector performance data should be valuable in solar systems analysis and for collector performance ranking based on all-day calculated conditions.

Simon, F. F.↗

Simulated Craters on Venus

The thick atmosphere of Venus prevents all but the largest impactors from cratering the surface. The number of small craters on Venus provides an interesting, and statistically significant test of models for the disruption and deceleration of impacting bodies. Here we compare Monte Carlo simulated crater distributions to the observed crater distribution on Venus. The simulation assumes: (1) a power law mass distribution for impactors of the form N(sub cum) alpha m (exp-b) where b=0.8; (2) isotropic incidence angles; (3) velocity at the top of the atmosphere of 20 kilometers per second (more realistic velocity distributions are also considered); (4) Schmidt-Housen crater scaling, modified such that only the normal component of the impact velocity contributes to cratering, and using crater slumping as parameterized (5) and modern populations (60% carbonaceous, 40% stone, 3% iron) and fluxes of asteroids. We use our previously developed model for the disruption and deceleration of large bodies striking thick planetary atmospheres to calculate the impact velocity at the surface as a function of impactor mass, incident velocity, and incident angle. We use a drag coefficient c(sub d) =1; other parameters are as described in Chyba et al. We set a low velocity cutoff of 500 meters per second on crater-forming impacts. Venus's craters are nicely matched by the simulated craters produced by 700 million years of striking asteroids. Shown for comparison are the simulated craters produced by incident comets over the same period, where for comets we have assumed b=0.7 and a flux at 10(exp 14) g 30% that of asteroids. Systematic uncertainties in crater scaling and crater slumping may make the surface age uncertain by a factor of two.

Zahnle, Kevin↗

Scanning-Pencil-Beam Radar Scatterometer

SCANSCAT conceptual scanning radar scatterometer placed in nearly polar orbit around Earth at altitude of 705 km aboard Spacecraft B of NASA's Earth Observing System. Measures radar backscattering from surface of ocean. Data processed on ground into normalized radar-backscattering cross sections, then processed into velocities of winds near surface of ocean by use of empirical mathematical model of relationship between normalized backscattering cross section, wind vector at scanned spot, and angle of incidence and azimuth angle of radar beam. Accuracy and coverage exceeds those of fan-beam scatterometer. Modified versions of scanning plan useful in laser inspection of surface finishes on machined parts.

Long, David G.↗

Southwest Water Resources: Monitoring Surface Water Extents of Remote Stock Ponds in the Southwestern United States Using Earth Observing Systems for Enhanced Water Resources Management

Due to increasingly frequent and severe drought conditions in the southwestern US, land managers and livestock producers need to monitor stock ponds with increasing regularity. The ability to assess stock pond water levels with Earth observing satellite systems would enhance monitoring efforts of partners at the US Forest Service, Arizona Department of Game and Fish, and the Diablo Trust. This study employed Landsat 8 Operational Land Imager (OLI), Sentinel-1 C-band Synthetic Aperture Radar (C-SAR), and Sentinel-2 Multispectral Instrument (MSI) to monitor surface water extent for hundreds of critical stock ponds in Arizona. Using methods adapted from previously developed image processing workflows, this project conducted a time-series analysis to capture seasonal and interannual variations in surface water area between 2013 to 2021. In addition, end users can monitor the surface water extent of stock ponds through the developed Google Earth Engine software tool called Surface Water Identification and Forecasting Tool (SWIFT). SWIFT incorporates the Automated Water Extraction Index, Modified Normalized Difference Water Index, and Tasseled Cap-Wetness Index for optical imagery and the incidence angle, VV and VH polarization bands for Sentinel-1 imagery to detect small water bodies in the study area with an overall accuracy range of 88-93%. These tools will empower our partners to monitor the extents of water in their stock ponds remotely, enabling them to develop data-informed and sustainable management solutions for decades to come.

Rainey Aberle↗

Outdoor flat-plate collector performance prediction from solar simulator test data

This paper describes how collector performance obtained from test data with a simulator can be modified for real-life conditions. The approach taken is to correct the performance data obtained with the simulator for the variable conditions of ambient temperature, wind, incident angle, flow rate, etc., that are encountered in outdoor conditions. Modification of simulator data is accomplished by combining experiment with theory. The technique is demonstrated by application to a spectrally selective and a nonselective type of collector. This kind of modified simulator collector performance data should be valuable in solar systems analyses and for collector performance ranking based on all-day calculated conditions.

Simon, F. F.↗

Correlation of Processing and Structure in an Ethylene‐Glycol Side‐Chain Modified Polythiophene via Combined X‐Ray Scattering and 4D Scanning Transmission Electron Microscopy

The results of a combined grazing incidence wide-angle X-ray scattering (GIWAXS) and 4D scanning transmission microscopy (4D-STEM) analysis of the effects of thermal processing on poly(3[2-(2-methoxyethoxy)ethoxy]-methylthiophene-2,5-diyl) are reported, a conjugated semiconducting polymer used as the active layer in organic electrochemical transistor devices. GIWAXS provides a measure of overall crystallinity in the film, while 4D-STEM produces real-space maps of the morphology and orientation of individual crystallites along with their spatial extent and distribution. The sensitivity of the 4D-STEM detector allows for collection of electron diffraction patterns at each position in an image scan while limiting the imparted electron dose to below the damage threshold. In conclusion, the effects of heat treatment on the distribution and type of crystallites present in the films is determined.

36 MATERIALS SCIENCE↗

Physical considerations governing computation of turbulent flows over bodies at large incidence

The physical aspects governing accurate numerical simulation of turbulent flows having large regions of crossflow separation are re-examined. Time-accurate, three-dimensional fine-grid Navier-Stokes solutions were obtained for turbulent subsonic and supersonic flows over a slender ogive-cylinder body of revolution at large angles of attack. These flowfields are complex and contain regions of crossflow separation and an organized leeward-side vortex structure. An algebraic eddy-viscosity turbulence model has been modified to correctly account for the effects of the vortices on the underlying viscous layers. The numerical results show that the vortical flow structure of both subsonic and supersonic high incidence flows are similar, and can be accurately treated by the turbulence model. As the angle of attack is increased, the effectiveness of the model increases since the influence of the vortices on the underlying boundary layer decreases.

Degani, David↗

Modified Hitschfeld-Bordan Equations for Attenuation-Corrected Radar Rain Reflectivity: Application to Nonuniform Beamfilling at Off-Nadir Incidence

As shown by Takahashi et al., multiple path attenuation estimates over the field of view of an airborne or spaceborne weather radar are feasible for off-nadir incidence angles. This follows from the fact that the surface reference technique, which provides path attenuation estimates, can be applied to each radar range gate that intersects the surface. This study builds on this result by showing that three of the modified Hitschfeld-Bordan estimates for the attenuation-corrected radar reflectivity factor can be generalized to the case where multiple path attenuation estimates are available, thereby providing a correction to the effects of nonuniform beamfilling. A simple simulation is presented showing some strengths and weaknesses of the approach.

nonuniform beamfilling↗

Design and laser damage properties of a dichroic beam combiner coating for 22.5-deg incidence and S polarization with high transmission at 527 nm and high reflection at 1054 nm

We designed a dichroic beam combiner coating with 11 HfO 2 /SiO 2 layer pairs and deposited it on a large substrate. It provides high transmission (HT) at 527 nm and high reflection (HR) at 1054 nm for a 22.5-deg angle of incidence (AOI), S polarization (Spol), and uses near half-wave layer thicknesses for HT at 527 nm, modified for HR at 1054 nm. The two options for the beam combiner each require that a high intensity beam be incident on the coating from within the substrate (from glass). We analyze the laser-induced damage threshold (LIDT) differences between the two options in terms of the 527- and 1054-nm E-field behaviors for air → coating and glass → coating incidences. This indicates that LIDTs should be higher for air → coating than for glass → coating incidence. LIDT tests at the use AOI, Spol with ns pulses at 532 and 1064 nm confirm this, with glass → coating LIDTs about half that of air → coating LIDTs. Lastly, these results clearly indicate that the best beam combiner option is for the high intensity 527 and 1054 nm beams to be incident on the coating from air and glass, respectively.

36 MATERIALS SCIENCE↗

Shuttle imaging radar (SIR-B) investigations of the Canadian Shield - Summary report

The objectives and results of two imaging-radar experiments carried on a Shuttle mission with the purpose of studying the structure of crustal province boundaries and the effects of illumination geometry are reviewed. The primary geological objectives as well as the secondary technique-oriented objective are outlined, along with digital processing techniques. The tectonic relationships of structural provinces are analyzed, and data pertaining to the Kapuskasing Structural Zone is discussed. Fracture patterns and diabase dike swarms are assessed. Focus is placed on the utilization of multiple look directions and incidence angles and on digital image-enhancement techniques such as linear contrast stretch, low-pass filter for speckle reduction, modified Moore-Waltz edge enhancement, and coregistration and display of multiple look azimuths.

Masuoka, P. M.↗