Search NASA⌕ Search

SEARCH · Search NASA

Results for “induced”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Sub-Scale Testing and Development of the J-2X Fuel Turbopump Inducer

In the early stages of the J-2X upper stage engine program, various inducer configurations proposed for use in the fuel turbopump (FTP) were tested in water. The primary objectives of this test effort were twofold. First, to obtain a more comprehensive data set than that which existed in the Pratt & Whitney Rocketdyne (PWR) historical archives from the original J-2S program, and second, to supplement that data set with information regarding the cavitation induced vibrations for both the historical J-2S configuration as well as those tested for the J-2X program. The J-2X FTP inducer, which actually consists of an inducer stage mechanically attached to a kicker stage, underwent 4 primary iterations utilizing sub-scaled test articles manufactured and tested in PWR's Engineering Development Laboratory (EDL). The kicker remained unchanged throughout the test series. The four inducer configurations tested retained many of the basic design features of the J-2S inducer, but also included variations on leading edge blade thickness and blade angle distribution, primarily aimed at improving suction performance at higher flow coefficients. From these data sets, the effects of the tested design variables on hydrodynamic performance and cavitation instabilities were discerned. A limited comparison of impact to the inducer efficiency was determined as well.

Sargent, Scott R.↗

Uncertainty Quantification of Inducer Natural Frequency using Conditional Assessment of Modeling and Modal Testing of Simpler Systems

The low pressure fuel pump inducer of the new Space Launch System RS25 core stage engine operates in a highly complex environment that substantially affects its modal characteristics. Some of the more important effects are fluid-added mass resulting from operation within a light liquid (Hydrogen), and the magnification of this effect due to tight tip clearance. Since higher order cavitation has been identified as a significant harmonic driver, knowledge of the natural frequency of potentially excitable modes is critical for safe operation, but this frequency cannot be measured during the severe operational environment. A comprehensive testing and analysis program has therefore been performed over the last four years to identify the nominal value and uncertainty of the frequency by modeling and testing four simpler structures which share some of the characteristics of the operational inducer. This testing was used to assess and adjust modeling techniques and excellent correlation was achieved. Identification of the uncertainty in the inducer frequency itself was still problematic, however. This difficulty led to an investigation of Bayesian uncertainty quantification techniques, and to the application of the relatively simple technique of Multi-Variate Normal conditional distributions to calculate the inducer natural frequency uncertainty. Assumptions on prior distributions of uncertainty of the fluid-added mass and tip clearance effect are initially applied to models of each of the simple structures and the inducer itself, and these uncertainties are propagated to generate natural frequencies using design of experiments. Simple response surfaces are then created from this data in order to calculate a Covariance Matrix relating all of these natural frequencies. Finally, the results from modal test of the simple structures are considered to be observations and used to calculate the conditional variance of the desired inducer frequencies. As this method is less rigorous than more complicated Bayesian methods reported in the literature, a conservative factor is applied to the result, but the resulting uncertainty is still significantly less than originally estimated and will greatly assist certification of the inducer for use in the engine.

Uncertainty Quantification↗

Uncertainty Quantification of Inducer Eigenvalues using Conditional Assessment of Models and Modal Test of Simpler Systems

The low pressure fuel pump inducer of the new Space Launch System RS25 core stage engine operates in a highly complex environment that substantially affects its modal characteristics. Some of the more important effects are fluid-added mass resulting from operation within a light liquid (Hydrogen), and the magnification of this effect due to tight tip clearance. Since higher order cavitation has been identified as a significant harmonic driver, knowledge of the natural frequency of potentially excitable modes is critical for safe operation, but this frequency cannot be measured during the severe operational environment. A comprehensive testing and analysis program has therefore been performed over the last four years to identify the nominal value and uncertainty of the frequency by modeling and testing four simpler structures which share some of the characteristics of the operational inducer. This testing was used to assess and adjust modeling techniques and excellent correlation was achieved. Identification of the uncertainty in the inducer frequency itself was still problematic, however. This difficulty led to an investigation of Bayesian uncertainty quantification techniques, and to the application of the relatively simple technique of Multi-Variate Normal conditional distributions to calculate the inducer natural frequency uncertainty. Assumptions on prior distributions of uncertainty of the fluid-added mass and tip clearance effect are initially applied to models of each of the simple structures and the inducer itself, and these uncertainties are propagated to generate natural frequencies using design of experiments. Simple response surfaces are then created from this data in order to calculate a Covariance Matrix relating all of these natural frequencies. Finally, the results from modal test of the simple structures are considered to be observations and used to calculate the conditional variance of the desired inducer frequencies. As this method is less rigorous than more complicated Bayesian methods reported in the literature, a conservative factor is applied to the result, but the resulting uncertainty is still significantly less than originally estimated and will greatly assist certification of the inducer for use in the engine.

Uncertainty Quantification↗

Clustered DNA damages induced in isolated DNA and in human cells by low doses of ionizing radiation

Clustered DNA damages-two or more closely spaced damages (strand breaks, abasic sites, or oxidized bases) on opposing strands-are suspects as critical lesions producing lethal and mutagenic effects of ionizing radiation. However, as a result of the lack of methods for measuring damage clusters induced by ionizing radiation in genomic DNA, neither the frequencies of their production by physiological doses of radiation, nor their repairability, nor their biological effects are known. On the basis of methods that we developed for quantitating damages in large DNAs, we have devised and validated a way of measuring ionizing radiation-induced clustered lesions in genomic DNA, including DNA from human cells. DNA is treated with an endonuclease that induces a single-strand cleavage at an oxidized base or abasic site. If there are two closely spaced damages on opposing strands, such cleavage will reduce the size of the DNA on a nondenaturing gel. We show that ionizing radiation does induce clustered DNA damages containing abasic sites, oxidized purines, or oxidized pyrimidines. Further, the frequency of each of these cluster classes is comparable to that of frank double-strand breaks; among all complex damages induced by ionizing radiation, double-strand breaks are only about 20%, with other clustered damage constituting some 80%. We also show that even low doses (0.1-1 Gy) of high linear energy transfer ionizing radiation induce clustered damages in human cells.

NASA Discipline Radiation Health↗

Theoretical monochromatic-wave-induced currents in intermediate water with viscosity and nonzero mass transport

Wave-induced mass-transport current theories with both zero and nonzero net mass (or volume) transport of the water column are reviewed. A relationship based on the Longuet-Higgens theory is derived for wave-induced, nonzero mass-transport currents in intermediate water depths for a viscous fluid. The relationship is in a form useful for experimental applications; therefore, some design criteria for experimental wave-tank tests are also presented. Sample parametric cases for typical wave-tank conditions and a typical ocean swell were assessed by using the relation in conjunction with an equation developed by Unluata and Mei for the maximum wave-induced volume transport. Calculations indicate that substantial changes in the wave-induced mass-transport current profiles may exist dependent upon the assumed net volume transport. A maximum volume transport, corresponding to an infinite channel or idealized ocean condition, produces the largest wave-induced mass-transport currents. These calculations suggest that wave-induced mass-transport currents may have considerable effects on pollution and suspended-sediments transport as well as buoy drift, the surface and midlayer water-column currents caused by waves increasing with increasing net volume transports. Some of these effects are discussed.

Talay, T. A.↗

On the shear pumping effect in rocket pump inducers

The momentum exchange between the fluid and the rotor via the shear stress in a rocket pump inducer is termed the shear pumping effect. This effect is investigated analytically in order to estimate the direct effect of shear stress in providing a head rise. An inducer with flat plates and one with cambered blades are considered. It is shown that the head rise coefficient and the relative velocities predicted from the theoretical analysis, based on momentum integral technique, seem to agree well with the measured data for a flat-plate inducer operated with open throttle and a cambered-blade inducer operated at a flow coefficient of 0.065. In particular, the flat-plate and the cambered-blade inducers have nearly the same performance, except for the axial velocity distribution. The former shows a tendency to separate in the hub region near the trailing edge, while the latter does not. Even far downstream, the flat-plate inducer has a larger separated zone near the hub.

Lakshminarayana, B.↗

Analytical and experimental study of flow phenomena in noncavitating rocket pump inducers

The flow processes in rocket pump inducers are summarized. The experimental investigations were carried out with air as the test medium. The major characteristics features of the rocket pump inducers are low flow coefficient (0.05 to 0.2) large stagger angle (70 deg to 85 deg) and high solidity blades of little or no camber. The investigations are concerned with the effect of viscosity not the effects of cavitation. Flow visualization, conventional and hot wire probe measurement inside and at the exit of the blade passage, were the analytical methods used. The experiment was carried out using four three and two bladed inducers with cambered blades. Both the passage and the exit flow were measured. The basic research and boundary layer investigation was carried out using a helical flat plate (of some dimensions as the inducer blades tested), and flat plate helical inducer (four bladed). Detailed mean and turbulence flow field inside the passage as well as the exit of the rotor were derived from these measurement. The boundary layer, endwall, and other passage data reveal extremely complex nature of the flow, with major effects of viscosity present across the entire passage. Several analyses were carried out to predict the flow field in inducers. These included an approximate analysis, the shear pumping analysis, and a numerical solution of exact viscous equations with approximate modeling for the viscous terms.

Lakshminarayana, B.↗

Pressure-induced H2 opacity in the 5-micron region

The H2 opacity arising from the pure-rotational hexadecapole-induced transitions occurring during H2-H2 and H2-He collisions, and from the hexadecapole-induced and the quadrupole-induced transitions in H2-He collisions, has been calculated. The hexadecapole-induced and quadrupole-induced contributions from H2-H2 collisions are important H2 opacities in the frequency range from 700-3000/cm for temperatures appropriate to the outer planets. It is concluded that this opacity is needed in addition to the opacity from the extrapolation of the 0-0 and 1-0 H2-H2 collisionally-induced bands to interpret the spectrum at 5 microns for the outer planets.

Goorvitch, D.↗

Prostaglandin E2 Prevents Disuse-Induced Cortical Bone Loss

The object of this study was to determine whether prostaglandin E2 (PGE2) can prevent disuse (underloaded)-induced cortical bone loss as well as add extra bone to underloaded bones. Thirteen-month-old retired female Sprague-Dawley breeders served as controls or were subjected to simultaneous right hindlimb immobilization by bandaging and daily subcutaneous doses of 0, 1, 3, or 6 mg PGE2/kg/d for two and six weeks. Histomorphometric analyses were performed on double-fluorescent labeled undecalcified tibial shaft sections (proximal to the tibiofibular junction). Disuse-induced cortical bone loss occurred by enlarging the marrow cavity and increasing intracortical porosity. PGE2 treatment of disuse shafts further increased intracortical porosity above that in disuse alone controls. This bone loss was counteracted by enhancement of periosteal and corticoendosteal bone formation. Stimulation of periosteal and corticoendosteal bone formation slightly enlarged the total tissue (cross-sectional) area and inhibited marrow cavity enlargement. These PGE2-induced activities netted the same percentage of cortical bone with a different distribution than the beginning and age related controls. These findings indicate the PGE2-induced increase in bone formation compensated for the disuse and PGE2-induced bone loss, and thus prevented immobilization induced bone loss.

Jee, Webster S. S.↗

Growth Factors and Tension-Induced Skeletal Muscle Growth

The project investigated biochemical mechanisms to enhance skeletal muscle growth, and developed a computer based mechanical cell stimulator system. The biochemicals investigated in this study were insulin/(Insulin like Growth Factor) IGF-1 and Steroids. In order to analyze which growth factors are essential for stretch-induced muscle growth in vitro, we developed a defined, serum-free medium in which the differentiated, cultured avian muscle fibers could be maintained for extended periods of time. The defined medium (muscle maintenance medium, MM medium) maintains the nitrogen balance of the myofibers for 3 to 7 days, based on myofiber diameter measurements and myosin heavy chain content. Insulin and IGF-1, but not IGF-2, induced pronounced myofiber hypertrophy when added to this medium. In 5 to 7 days, muscle fiber diameters increase by 71 % to 98% compared to untreated controls. Mechanical stimulation of the avian muscle fibers in MM medium increased the sensitivity of the cells to insulin and IGF-1, based on a leftward shift of the insulin dose/response curve for protein synthesis rates. (54). We developed a ligand binding assay for IGF-1 binding proteins and found that the avian skeletal muscle cultures produced three major species of 31, 36 and 43 kD molecular weight (54) Stretch of the myofibers was found to have no significant effect on the efflux of IGF-1 binding proteins, but addition of exogenous collagen stimulated IGF-1 binding protein production 1.5 to 5 fold. Steroid hormones have a profound effect on muscle protein turnover rates in vivo, with the stress-related glucocorticoids inducing rapid skeletal muscle atrophy while androgenic steroids induce skeletal muscle growth. Exercise in humans and animals reduces the catabolic effects of glucocorticoids and may enhance the anabolic effects of androgenic steroids on skeletal muscle. In our continuing work on the involvement of exogenrus growth factors in stretch-induced avian skeletal muscle growth, we have performed experiments to determine whether mechanical stimulation of cultured avian muscle cells alters their response to anabolic steroids or glucocorticoids. In static cultures, testosterone had no effect on muscle cell growth, but 5alpha-dihydrotestosterone and the synthetic steroid stanozolol increased cell growth by up to 18% and 30%, respectively, after a three day exposure. We completed development of a new IBM-based mechanical cell stimulator system to provide greater flexibility in operating and monitoring our experiments. Our previous long term studies on myofiber growth were designed around a perfusion system of our own design. We have recently changed to performing these studies using a modified CELLCO cartridge bioreactor system Z since it has been certified as the ground-based model for the Shuttle's Space Tissue Loss (STL) F= Cell Culture Module. The current goals of this aspect of the project are three fold: 1) to design a Z cell culture system for studying avian skeletal myofiber atrophy on the Shuttle and Space Station; 0 2) to expand the use of bioreactors to cells which do not grow in either suspension or attached to the hollow fibers; and 3) to combine the bioreactor system with our computerized mechanical cell stimulator to have a better in vitro model to study tension/gravity/stretch regulation of skeletal muscle size. Preliminary studies also reported on involved : (1) how release of tension can induce rapid atrophy of tissues cultured avian skeletal muscle cells, and (2) a mechanism to transfer and maintain avian skeletal muscle organoids in modified cartridges in the Space Tissue Loss Module.

Vandenburgh, Herman H.↗

Inducer Hydrodynamic Forces in a Cavitating Environment

Marshall Space Flight Center has developed and demonstrated a measurement device for sensing and resolving the hydrodynamic loads on fluid machinery. The device - a derivative of the six-component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This rotating balance was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining the amplitude and frequency content associated with operating in various cavitation modes. The rotating balance was calibrated statically using a dead-weight load system in order to generate the 6 x 12 calibration matrix later used to convert measured voltages to engineering units. Structural modeling suggested that the rotating assembly first bending mode would be significantly reduced with the balance s inclusion. This reduction in structural stiffness was later confirmed experimentally with a hammer-impact test. This effect, coupled with the relatively large damping associated with the rotating balance waterproofing material, limited the device s bandwidth to approximately 50 Hertz Other pre-test validations included sensing the test article rotating assembly built-in imbalance for two configurations and directly measuring the assembly mass and buoyancy while submerged under water. Both tests matched predictions and confirmed the device s sensitivity while stationary and rotating. The rotating balance was then demonstrated in a water test of a full-scale Space Shuttle Main Engine high-pressure liquid oxygen pump inducer. Experimental data was collected a scaled operating conditions at three flow coefficients across a range of cavitation numbers for the single inducer geometry and radial clearance. Two distinct cavitation modes were observed symmetric tip vortex cavitation and alternate-blade cavitation. Although previous experimental tests on the same inducer demonstrated two additional cavitation modes at lower inlet pressures, these conditions proved unreachable with the rotating balance installed due to the intense dynamic environment. The sensed radial load was less influenced by flow coefficient than by cavitation number or cavitation mode although the flow coefficient range was relatively narrow. Transition from symmetric tip vortex to alternate-blade cavitation corresponded to changes in both radial load magnitude and radial load orientation relative to the inducer. Sensed moments indicated that the effective load center moved downstream during this change in cavitation mode. An occurrence of "higher+rdex cavitation" was also detected in both the stationary pressures and the rotating balance data although the frequency of the phenomena was well above the reliable bandwidth of the rotating balance. In summary the experimental tests proved both the concept and device s capability despite the limitations and confirmed that hydrodynamically-induced forces and moments develop in response to the unbalanced pressure field, which is, in turn, a product of the cavitation environment.

Skelley, Stephen E.↗

Auxin-induced growth of Avena coleoptiles involves two mechanisms with different pH optima

Although rapid auxin-induced growth of coleoptile sections can persist for at least 18 hours, acid-induced growth lasts for a much shorter period of time. Three theories have been proposed to explain this difference in persistence. To distinguish between these theories, the pH dependence for auxin-induced growth of oat (Avena sativa L.) coleoptiles has been determined early and late in the elongation process. Coleoptile sections from which the outer epidermis was removed to facilitate buffer entry were incubated, with or without 10 micromolar indoleacetic acid, in 20 millimolar buffers at pH 4.5 to 7.0 to maintain a fixed wall pH. During the first 1 to 2 hours after addition of auxin, elongation occurs by acid-induced extension (i.e. the pH optimum is <5 and the elongation varies inversely with the solution pH). Auxin causes no additional elongation because the buffers prevent further changes in wall pH. After 60 to 90 minutes, a second mechanism of auxin-induced growth, whose pH optimum is 5.5 to 6.0, predominates. It is proposed that rapid growth responses to changes in auxin concentration are mediated by auxin-induced changes in wall pH, whereas the prolonged, steady-state growth rate is controlled by a second, auxin-mediated process whose pH optimum is less acidic.

NASA Program Space Biology↗

The role of calcium in growth induced by indole-3-acetic acid and gravity in the leaf-sheath pulvinus of oat (Avena sativa)

Leaf-sheath pulvini of excised segments from oat (Avena sativa L.) were induced to grow by treatment with 10 micromoles indole-3-acetic acid (IAA), gravistimulation, or both, and the effects of calcium, EGTA, and calcium channel blockers on growth were evaluated. Unilaterally applied calcium (10 mM CaCl2) significantly inhibited IAA-induced growth in upright pulvini but had no effect on growth induced by either gravity or gravity plus IAA. Calcium alone had no effect on upright pulvini. The calcium chelator EGTA alone (10 mM) stimulated growth in upright pulvini. However, EGTA had no effect on either IAA- or gravity-induced growth but slightly diminished growth in IAA-treated gravistimulated pulvini. The calcium channel blockers lanthanum chloride (25 mM), verapamil (2.5 mM), and nifedipine (2.5 mM) greatly inhibited growth as induced by IAA (> or = 50% inhibition) or IAA plus gravity (20% inhibition) but had no effect on gravistimulated pulvini. Combinations of channel blockers were similar in effect on IAA action as individual blockers. Since neither calcium ions nor EGTA significantly affected the graviresponse of pulvini, we conclude that apoplastic calcium is unimportant in leaf-sheath pulvinus gravitropism. The observation that calcium ions and calcium channel blockers inhibit IAA-induced growth, but have no effect on gravistimulated pulvini, further supports previous observations that gravistimulation alters the responsiveness of pulvini to IAA.

Non-NASA Center↗

Ca(2+) regulates fluid shear-induced cytoskeletal reorganization and gene expression in osteoblasts

Osteoblasts subjected to fluid shear increase the expression of the early response gene, c-fos, and the inducible isoform of cyclooxygenase, COX-2, two proteins linked to the anabolic response of bone to mechanical stimulation, in vivo. These increases in gene expression are dependent on shear-induced actin stress fiber formation. Here, we demonstrate that MC3T3-E1 osteoblast-like cells respond to shear with a rapid increase in intracellular Ca(2+) concentration ([Ca(2+)](i)) that we postulate is important to subsequent cellular responses to shear. To test this hypothesis, MC3T3-E1 cells were grown on glass slides coated with fibronectin and subjected to laminar fluid flow (12 dyn/cm(2)). Before application of shear, cells were treated with two Ca(2+) channel inhibitors or various blockers of intracellular Ca(2+) release for 0. 5-1 h. Although gadolinium, a mechanosensitive channel blocker, significantly reduced the [Ca(2+)](i) response, neither gadolinium nor nifedipine, an L-type channel Ca(2+) channel blocker, were able to block shear-induced stress fiber formation and increase in c-fos and COX-2 in MC3T3-E1 cells. However, 1, 2-bis(2-aminophenoxy)ethane-N,N,N',N'-tetraacetic acid-AM, an intracellular Ca(2+) chelator, or thapsigargin, which empties intracellular Ca(2+) stores, completely inhibited stress fiber formation and c-fos/COX-2 production in sheared osteoblasts. Neomycin or U-73122 inhibition of phospholipase C, which mediates D-myo-inositol 1,4,5-trisphosphate (IP(3))-induced intracellular Ca(2+) release, also completely suppressed actin reorganization and c-fos/COX-2 production. Pretreatment of MC3T3-E1 cells with U-73343, the inactive isoform of U-73122, did not inhibit these shear-induced responses. These results suggest that IP(3)-mediated intracellular Ca(2+) release is required for modulating flow-induced responses in MC3T3-E1 cells.

Non-NASA Center↗

Activation of G proteins mediates flow-induced prostaglandin E2 production in osteoblasts

Interstitial fluid flow may play a role in load-induced bone remodeling. Previously, we have shown that fluid flow stimulates osteoblast production of cAMP inositol trisphosphate (IP3), and PGE2. Flow-induced increases in cAMP and IP3 were shown to be a result of PG production. Thus, PGE2 production appears to be an important component in fluid flow induced signal transduction. In the present study, we investigated the mechanism of flow-induced PGE2 synthesis. Flow-induced a 20-fold increase in PGE2 production in osteoblasts. Increases were also observed with ALF4-(10mM) (98-fold), an activator of guanidine nucleotide-binding proteins (G proteins), and calcium ionophore A23187 (2 microM) (100-fold) in stationary cells. We then investigated whether flow stimulation is mediated by G proteins and increases in intracellular calcium. Flow-induced PGE2 production was inhibited by the G protein inhibitors GDP beta S (100 microM) and pertussis toxin (1 microgram/ml) by 83% and 72%, respectively. Chelation of extracellular calcium by EGTA (2 mM) and intracellular calcium by quin-2/AM (30 microM) blocked flow stimulation by 87% and 67%, respectively. These results suggest that G proteins and calcium play an important role in mediating mechanochemical signal transduction in osteoblasts.

NASA Discipline Cell Biology↗

Reducing the Effect of Transducer Mount Induced Noise on Aeroacoustic Wind Tunnel Testing Data with a New Transducer Mount Design

Characterization of launch vehicle unsteady aerodynamics is a field best studied through experimentation, which is often carried out in the form of large scale wind tunnel testing. Measurement of the fluctuating pressures induced by the boundary layer noise is customarily made with miniature pressure transducers installed into a model of the vehicle of interest. Literature shows that noise level increases between two to five decibels (dB referenced to 20 micropascal) can be induced when the transducer surface is not mounted perfectly flush with the model outer surface. To reduce this artificially induced noise, special transducer holders have been used for aeroacoustic wind tunnel testing by NASA. This holder is a sleeve into which the transducer fits, with a cap that allows it to be mounted in a recessed hole in the model. A single hole in the holder allows the transport of the tunnel medium so the transducer can discriminate the fluctuating pressure due to the turbulent boundary layer noise. The holder is first dry fitted into the model and any difference in height between the holder and the model surface can be sanded flush. The holder is then removed from the model, the transducer glued inside the holder, and the holder replaced in the model, secured also with glue, thus eliminating the problem of noise level increases due to lack of flushness. In order to work with this holder design, special transducers have been ordered with their standard screen removed and the diaphragm moved as close to the top of the casing as possible to minimize any cavity volume. Although this greatly reduces induced noise due to the transducers being out of flush, the holders can also induce a cavity resonance that is usually at a very high frequency. This noise is termed transducer mount induced noise (XMIN). The peak of the mode can vary with the cavity depth, boundary layer noise that can excite the mode, tunnel flow medium, and the build of the transducers. Because the boundary layer flow interaction with the microphone holder seems to have some effect on the cavity resonance response, the NASA/Marshall Space Flight Center (MSFC) aeroacoustic team postulated that changing the design of the holder might reduce the cavity resonance response. An experiment was performed at the MSFC Trisonic Wind Tunnel comparing a new holder design with the traditional MSFC holder. The new holder design is intended to mimic the Kulite Semiconductors, Inc. B-screen, where the single hole of the traditional MSFC holder is replaced by a series of ten 0.007 inch diameter holes. This particular design serves to protect the transducer diaphragm as in the manufacturer's B-screen, but also increases the frequency of the XMIN such that it is not apparent in the data collected from aeroacoustic wind tunnel tests. MSFC compared the two holder designs by installing two transducers in standard holders on one side of a ten inch long ten degree cone, and two transducers in B-screen holders on the opposite side for a series of runs at different conditions. Over 11-13 February, 2013, the model was run at Mach numbers between 0.80 and 1.96 at angles of attack at 0 deg, plus or minus 1 deg, plus or minus 2 deg, plus or minus 4 deg, and plus or minus 8 deg. Model roll attitudes at 0 deg, 90 deg, and 180 deg were tested to isolate potential tunnel bias. This paper presents results from the test showing that the proposed holder design significantly reduces the influence of XMIN on measured fluctuating pressure levels.

Herron, A. J.↗

Prevention of Spaceflight-Induced Bone Loss: A Promising Dietary Countermeasure

Space radiation is one of the challenges for long-term spaceflight, especially for missions beyond low Earth Orbit. We have shown that a diet composed of 25% dried plum (DP) prevents radiation-induced bone loss. The DP diet fully protected the cancellous bone microarchitecture of mice exposed to ionizing radiation (gamma, proton, and HZE). In particular relevant to space radiation, we showed that the DP diet prevents bone loss due to 1Gy of sequential exposure of proton (1H, low linear energy transfer -LET-), and 1Gy of iron (56Fe, high-LET). In addition, total body exposure to 1Gy of HZE radiation (56Fe) impaired the osteoprogenitors in mice fed the control diet, as indicated by decreased osteoblast mineralization. In contrast, marrow stem cells from mice fed the DP did not exhibit these deficits. Based on these promising results supporting DP as a countermeasure to prevent space radiation induced-tissue damage, we conducted additional studies to combine radiation and simulated microgravity. We exposed skeletally mature male mice to simulated microgravity (using hindlimb unloading, HU) or total body irradiation (TBI, 2Gy 137Cs) or in combination (HU+TBI). We observed bone loss in the mice fed the control diet (CD) exposed to simulated spaceflight, as measured by cancellous bone microarchitecture parameters such as percent bone volume (BV/TV). In contrast, mice fed the DP diet did not exhibit similar bone loss with either treatments (HU or TBI) or combined (HU+TBI) as seen in most parameters. This was observed in both long bones (tibia) and axial bones (vertebrae). Furthermore, preliminary data shows that pre-feeding with the DP diet attenuates the HU-induced decrement in bone-forming osteoblasts colony counts and mineralization capacity of the osteoprogenitor cells. We also performed DP feeding at lower doses (5%, 10%) and found that these doses are less effective in preventing the radiation-induced bone loss. All our studies with the DP diet as a countermeasure were done with a period of pre-feeding ranging from 14 to 21 days before irradiation, and in order to test the capacity of the DP diet as a countermeasure provided after exposure to radiation, we exposed mice to 2Gy gamma radiation and then provided the DP diet 24 hours post-IR. Preliminary data indicates that DP mitigated the radiation-induced deficits in certain cancellous bone structural parameters. Finally, we showed that mice fed with the control diet (CD) increased oxidative damage in the serum after radiation exposure, whereas mice fed the DP diet do did not show such an increase. In summary, the DP diet is a promising countermeasure for spaceflight-induced tissue damage.

Schreurs, Ann-Sofie↗

Estimating Inducer Blade Damping in Water with On-Blade Strain Measurements

This paper describes the testing, methodology, and results for estimating critical damping ratios of inducer blade structural natural frequencies. A sub-scale inducer water flow test was performed with on-blade strain gauge measurements. Data were acquired in quiescent air and water, and also at several shaft speeds and operating conditions. Two methods were used to provide active excitation to the blades. The first was to impart a mechanical impulse to the inducer shaft and observe the strain gauge response. The second was to install a stator plate upstream of the inducer to create a non-uniform but regular pressure field at the inducer inlet. There are challenges with using either approach, but damping information was extracted using both methods. Results showed that the critical damping ratio for a given blade mode increased from air to quiescent water, and also increased when the inducer was spinning.

Mulder, Andrew↗