Search NASA⌕ Search

SEARCH · Search NASA

Results for “information density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Analysis of line integrated electron density using plasma position data on Korea Superconducting Tokamak Advanced Research

A 280 GHz single-channel horizontal millimeter-wave interferometer system has been installed for plasma electron density measurements on the Korea Superconducting Tokamak Advanced Research (KSTAR) device. This system has a triangular beam path that does not pass through the plasma axis due to geometrical constraints in the superconducting tokamak. The term line density on KSTAR has a different meaning from the line density of other tokamaks. To estimate the peak density and the mean density from the measured line density, information on the position of the plasma is needed. The information has been calculated from tangentially viewed visible images using the toroidal symmetry of the plasma. Interface definition language routines have been developed for this purpose. The calculated plasma position data correspond well to calculation results from magnetic analysis. With the position data and an estimated plasma profile, the peak density and the mean density have been obtained from the line density. From these results, changes of plasma density themselves can be separated from effects of the plasma movements, so they can give valuable information on the plasma status.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating the risk of data loss due to particle radiation damage in a DNA data storage system

DNA data storage is a potential alternative to magnetic tape for archival storage purposes, promising substantial gains in information density. Critical to the success of DNA as a storage media is an understanding of the role of environmental factors on the longevity of the stored information. In this paper, we evaluate the effect of exposure to ionizing particle radiation, a cause of data loss in traditional magnetic media, on the longevity of data in DNA data storage pools. We develop a mass action kinetics model to estimate the rate of damage accumulation in DNA strands due to neutron interactions with both nucleotides and residual water molecules, then utilize the model to evaluate the effect several design parameters of a typical DNA data storage scheme have on expected data longevity. Finally, we experimentally validate our model by exposing dried DNA samples to different levels of neutron irradiation and analyzing the resulting error profile. Our results show that particle radiation is not a significant contributor to data loss in DNA data storage pools under typical storage conditions.

97 MATHEMATICS AND COMPUTING↗

Quantification of vapor screen analysis

The traditionally qualitative method of vapor screening is applied to the task of gathering quantitative density measurements in supersonic flows. Quantitative density information for flow around a two-dimensional biconvex airfoil at Mach 2.8 is extracted from digitized images of vapor screens by assuming a linear relation between particle density and scattering intensity. Intensity readings are calibrated through known conditions in the free stream and at the airfoil bow shock. The experimental results are compared to densities generated by a Euler code and determined to have errors of less than ten percent.

Benedict, Lance H.↗

The influence of respiratory motion on CT image volume definition

Purpose: Radiotherapy treatments are based on geometric and density information acquired from patient CT scans. It is well established that breathing motion during scan acquisition induces motion artifacts in CT images, which can alter the size, shape, and density of a patient's anatomy. The aim of this work is to examine and evaluate the impact of breathing motion on multislice CT imaging with respiratory synchronization (4DCT) and without it (3DCT). Methods: A specific phantom with a movable insert was used. Static and dynamic phantom acquisitions were obtained with a multislice CT. Four sinusoidal breath patterns were simulated to move known geometric structures longitudinally. Respiratory synchronized acquisitions (4DCT) were performed to generate images during inhale, intermediate, and exhale phases using prospective and retrospective techniques. Static phantom data were acquired in helical and sequential mode to define a baseline for each type of respiratory 4DCT technique. Taking into account the fact that respiratory 4DCT is not always available, 3DCT helical image studies were also acquired for several CT rotation periods. To study breath and acquisition coupling when respiratory 4DCT was not performed, the beginning of the CT image acquisition was matched with inhale, intermediate, or exhale respiratory phases, for each breath pattern. Other coupling scenarios were evaluated by simulating different phantom and CT acquisition parameters. Motion induced variations in shape and density were quantified by automatic threshold volume generation and Dice similarity coefficient calculation. The structure mass center positions were also determined to make a comparison with their theoretical expected position. Results: 4DCT acquisitions provided volume and position accuracies within ±3% and ±2 mm for structure dimensions >2 cm, breath amplitude ≤15 mm, and breath period ≥3 s. The smallest object (1 cm diameter) exceeded 5% volume variation for the breath patterns of higher frequency and amplitude motion. Larger volume differences (>10%) and inconsistencies between the relative positions of objects were detected in image studies acquired without respiratory control. Increasing the 3DCT rotation period caused a higher distortion in structures without obtaining their envelope. Simulated data showed that the slice acquisition time should be at least twice the breath period to average object movement. Conclusions: Respiratory 4DCT images provide accurate volume and position of organs affected by breath motion detecting higher volume discrepancies as amplitude length or breath frequency are increased. For 3DCT acquisitions, a CT should be considered slow enough to include lesion envelope as long as the slice acquisition time exceeds twice the breathing period. If this requirement cannot be satisfied, a fast CT (along with breath-hold inhale and exhale CTs to estimate roughly the ITV) is recommended in order to minimize structure distortion. Even with an awareness of a patient's respiratory cycle, its coupling with 3DCT acquisition cannot be predicted since patient anatomy is not accurately known.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Developing a Machine-Learning-Based Processing Framework for Twitter and Other Crowdsourced Data

Crowdsourced data streams such as Twitter and other social media are important sources of real-time and historical global information for Earth science applications. At the NASA Goddard Earth Sciences Data and Information Services Center (GES DISC), we have been exploring the Twitter data stream for its potential in augmenting the validation program of NASA's Global Precipitation Measurement (GPM) mission. To realize this potential, we need to increase the information density and enhance the quality of filtered precipitation tweets. We have implemented various components of a machine learning (ML)-based processing infrastructure for crowdsourced data that outputs, in this instance, useful and usable information derived from precipitation tweets. We have test enriched the Twitter stream with higher quality active tweets from those knowingly contributing to our effort and from existing crowdsourced programs (e.g., mPING, CoCoRaHS). We have experimented with various algorithms for processing tweets, including Naà ve Bayes, Convolutional Neural Network (CNN), Hierarchical Attention Network (HAN), and semi-supervised learning (with tri-training). Our current work focuses on (1) automated review of Earth science-related publications to determine relationships between discipline research needs and ML algorithms; (2) investigating Sequential Generative Adversarial Network (SeqGAN) for processing precipitation tweets for anomaly detection; and (3) managing crowdsourced data in a way that is compatible with existing NASA satellite data archives and using the data for ML applications. Key results include (1) network visualization of NLP-processed publications in various Earth science disciplines; (2) difference between GPM-linked, generated tweets and collected actual tweets that is small for GPM-determined light to moderate rain cases and high for GPM-determined heavy rain cases; and (3) identification of MongoDB for storing raw tweets and Zarr format for gridded tweets (compatible with GPM data). Our results have taken us a step closer to an operational ML-based tweet processing infrastructure and have already demonstrated that tweet-derived precipitation information is potentially useful for validation of Earth science satellite data.

Teng, William↗

MO-D-PinS Room/Hall E-00: MR Simulation

MRI, with its excellent soft tissue contrast and its ability to provide physiological as well as anatomical information, is becoming increasingly used in radiation therapy for treatment planning, image-guided radiation therapy, and treatment evaluation. This session will explore solutions to integrating MRI into the simulation process. Obstacles for using MRI for simulation include distortions and artifacts, image acquisition speed, complexity of imaging techniques, and lack of electron density information. Partners in Solutions presents vendor representatives who will present their approaches to meeting these challenges and others. An increased awareness of how MRI simulation works will allow physicists to better understand and use this powerful technique. The speakers are all employees who are presenting information about their company’s products.

60 APPLIED LIFE SCIENCES↗

MO-D-PinS Room/Hall E-01: Integrating MR into Radiation Therapy

MRI, with its excellent soft tissue contrast and its ability to provide physiological as well as anatomical information, is becoming increasingly used in radiation therapy for treatment planning, image-guided radiation therapy, and treatment evaluation. This session will explore solutions to integrating MRI into the simulation process. Obstacles for using MRI for simulation include distortions and artifacts, image acquisition speed, complexity of imaging techniques, and lack of electron density information. Partners in Solutions presents vendor representatives who will present their approaches to meeting these challenges and others. An increased awareness of how MRI simulation works will allow physicists to better understand and use this powerful technique. The speakers are all employees who are presenting information about their company’s products.

60 APPLIED LIFE SCIENCES↗

MO-D-PinS Room/Hall E-02: Multiparametric Fuctional Imaging in Radiation Therapy

MRI, with its excellent soft tissue contrast and its ability to provide physiological as well as anatomical information, is becoming increasingly used in radiation therapy for treatment planning, image-guided radiation therapy, and treatment evaluation. This session will explore solutions to integrating MRI into the simulation process. Obstacles for using MRI for simulation include distortions and artifacts, image acquisition speed, complexity of imaging techniques, and lack of electron density information. Partners in Solutions presents vendor representatives who will present their approaches to meeting these challenges and others. An increased awareness of how MRI simulation works will allow physicists to better understand and use this powerful technique. The speakers are all employees who are presenting information about their company’s products.

60 APPLIED LIFE SCIENCES↗

MO-D-PinS Room/Hall E-03: Ingenia MR-RT with MRCAT for MR-Based Radiotherapy Simulation

MRI, with its excellent soft tissue contrast and its ability to provide physiological as well as anatomical information, is becoming increasingly used in radiation therapy for treatment planning, image-guided radiation therapy, and treatment evaluation. This session will explore solutions to integrating MRI into the simulation process. Obstacles for using MRI for simulation include distortions and artifacts, image acquisition speed, complexity of imaging techniques, and lack of electron density information. Partners in Solutions presents vendor representatives who will present their approaches to meeting these challenges and others. An increased awareness of how MRI simulation works will allow physicists to better understand and use this powerful technique. The speakers are all employees who are presenting information about their company’s products.

60 APPLIED LIFE SCIENCES↗

Improved simulation of aerosol, cloud, and density measurements by shuttle lidar

Data retrievals are simulated for a Nd:YAG lidar suitable for early flight on the space shuttle. Maximum assumed vertical and horizontal resolutions are 0.1 and 100 km, respectively, in the boundary layer, increasing to 2 and 2000 km in the mesosphere. Aerosol and cloud retrievals are simulated using 1.06 and 0.53 microns wavelengths independently. Error sources include signal measurement, conventional density information, atmospheric transmission, and lidar calibration. By day, tenuous clouds and Saharan and boundary layer aerosols are retrieved at both wavelengths. By night, these constituents are retrieved, plus upper tropospheric, stratospheric, and mesospheric aerosols and noctilucent clouds. Density, temperature, and improved aerosol and cloud retrievals are simulated by combining signals at 0.35, 1.06, and 0.53 microns. Particlate contamination limits the technique to the cloud free upper troposphere and above. Error bars automatically show effect of this contamination, as well as errors in absolute density nonmalization, reference temperature or pressure, and the sources listed above. For nonvolcanic conditions, relative density profiles have rms errors of 0.54 to 2% in the upper troposphere and stratosphere. Temperature profiles have rms errors of 1.2 to 2.5 K and can define the tropopause to 0.5 km and higher wave structures to 1 or 2 km.

Russell, P. B.↗

Technical note: Optimization for improved tube-loading efficiency in the dual-energy computed tomography coupled with balanced filter method

Purpose: This article describes the spectral optimization of dual-energy computed tomography using balanced filters (bf-DECT) to reduce the tube loadings and dose by dedicating to the acquisition of electron density information, which is essential for treatment planning in radiotherapy. Methods: For the spectral optimization of bf-DECT, the author calculated the beam-hardening error and air kerma required to achieve a desired noise level in an electron density image of a 50-cm-diameter cylindrical water phantom. The calculation enables the selection of beam parameters such as tube voltage, balanced filter material, and its thickness. Results: The optimal combination of tube voltages was 80 kV/140 kV in conjunction with Tb/Hf and Bi/Mo filter pairs; this combination agrees with that obtained in a previous study [M. Saito, ''Spectral optimization for measuring electron density by the dual-energy computed tomography coupled with balanced filter method,'' Med. Phys. 36, 3631-3642 (2009)], although the thicknesses of the filters that yielded a minimum tube output were slightly different from those obtained in the previous study. The resultant tube loading of a low-energy scan of the present bf-DECT significantly decreased from 57.5 to 4.5 times that of a high-energy scan for conventional DECT. Furthermore, the air kerma of bf-DECT could be reduced to less than that of conventional DECT, while obtaining the same figure of merit for the measurement of electron density and effective atomic number. Conclusions: The tube-loading and dose efficiencies of bf-DECT were considerably improved by sacrificing the quality of the noise level in the images of effective atomic number.

60 APPLIED LIFE SCIENCES↗

Too big, too small, or just right? A benchmark assessment of density functional theory for predicting the spatial extent of the electron density of small chemical systems

Multipole moments are the first-order responses of the energy to spatial derivatives of the electric field strength. The quality of density functional theory prediction of molecular multipole moments thus characterizes errors in modeling the electron density itself, as well as the performance in describing molecules interacting with external electric fields. However, only the lowest non-zero moment is translationally invariant, making the higher-order moments origin-dependent. Therefore, instead of using the 3 × 3 quadrupole moment matrix, we utilize the translationally invariant 3 × 3 matrix of second cumulants (or spatial variances) of the electron density as the quantity of interest (denoted by K). The principal components of K are the square of the spatial extent of the electron density along each axis. A benchmark dataset of the principal components of K for 100 small molecules at the coupled cluster singles and doubles with perturbative triples at the complete basis set limit is developed, resulting in 213 independent K components. The performance of 47 popular and recent density functionals is assessed against this Var213 dataset. Several functionals, especially double hybrids, and also SCAN and SCAN0 predict reliable second cumulants, although some modern, empirically parameterized functionals yield more disappointing performance. The H, Li, and Be atoms, in particular, are challenging for nearly all methods, indicating that future functional development could benefit from the inclusion of their density information in training or testing protocols.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards an optimal flow: Density-of-states-informed replica-exchange simulations

Here we learn that replica exchange (RE) is one of the most popular enhanced-sampling simulations technique in use today. Despite widespread successes, RE simulations can sometimes fail to converge in practical amounts of time, e.g., when sampling around phase transitions, or when a few hard-to-find configurations dominate the statistical averages. We introduce a generalized RE scheme, density-of-states-informed RE, that addresses some of these challenges. The key feature of our approach is to inform the simulation with readily available, but commonly unused, information on the density of states of the system as the RE simulation proceeds. This enables two improvements, namely, the introduction of resampling moves that actively move the system towards equilibrium and the continual adaptation of the optimal temperature set. As a consequence of these two innovations, we show that the configuration flow in temperature space is optimized and that the overall convergence of RE simulations can be dramatically accelerated.

97 MATHEMATICS AND COMPUTING↗

Three-dimensional estimation of deciduous forest canopy structure and leaf area using multi-directional, leaf-on and leaf-off airborne lidar data

Airborne laser scanning (ALS) has been widely used to map gap probability and leaf area index (LAI) distribution at plot and landscape scales. As an indirect measurement, most ALS methods to estimate LAI combine waveform or point density information with supporting field measurements such as the leaf angle distribution, gap probability, or direct LAI measures. The development of a more independent estimation approach would facilitate more widespread use of existing ALS data to investigate patterns of forest structure and build realistic 3-D vegetation scenes to simulate remote sensing imagery and energy balance. Here, we develop a data processing workflow (named PVlad) using ALS point cloud apparent reflectance to estimate LAI and voxel-based leaf area density (LAD), aiming to reduce the need for associated field measurements such as the gap probability. The adaptation of the path volume (PV) concept derived from apparent reflectance integrates information from multi-directional ALS pulses, and quantifies the percentage exploration of each voxel for classification and occlusion correction, such that rigorous volumetric sampling approaches can be developed to derive LAI and LAD. The PVlad workflow was applied to discrete-return lidar data (Riegl VQ480i) acquired by NASA Goddard's LiDAR, Hyperspectral and Thermal Imager (G-LiHT) Airborne Imager during leaf-on (summer) and leaf-off (spring) conditions at the Smithsonian Environmental Research Center (SERC). The estimates of LAI and LAD captured structural differences between mature, logged, and intermediate-aged stands over eight deciduous forest plots. The derived LAI values were compared to field litter collection measurements, and the derived LAD vertical distribution was compared to the output of the VoxLAD model using terrestrial laser scan (TLS) field survey data. Using voxel sizes ranging from 0.5 m to 5 m, overall LAI estimation showed linear fitting coefficient bias and for 1 and 2 m voxel sizes, and vertical LAD distribution showed strong correlation with and for 0.5 and 1m voxel sizes. For every forest stand, upper-canopy LAD had a low variance for voxel sizes of ≤ . Application of PVlad to the G-LiHT and other similar ALS data archives enables the development of fine-resolution LAI map products, including voxelization of LAD for ecosystem science and radiative transfer simulations of remote sensing imagery or surface energy balance.

Tiangang Yin↗

An implementation of a high-order generalized finite difference method for solving the time-harmonic cold plasma wave equation in toroidal geometry

A high-order physics-informed meshless finite difference numerical technique is introduced for solving the time-harmonic cold plasma wave equation in toroidal geometries, presenting a novel application of the generalized finite difference (GFD) method to plasma wave simulations. The algorithm employs an irregular distribution of computational points, with local point density informed by the shortest wavelength derived from the cold plasma dispersion relation. Numerical stability and robustness are addressed using regularization techniques. The algorithm, implemented for two spatial dimensions, solves for the wave electric field and is demonstrated to achieve convergence rates of $\mathcal{O}$($\mathcal{h}$ $\mathcal{P}$ )⁠. Verification tests reproduce plane wave solutions, and example simulations of ion cyclotron resonance heating and electron cyclotron resonance heating demonstrate its capability, approaching realistic tokamak plasma scenarios. This work contributes to laying a foundation for the GFD method to be used in more sophisticated, optimized, and physically realistic full-wave simulations in time-harmonic plasma wave research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation Of Glass Density To Support The Estimation Of Fissile Mass Loadings From Iron Concentrations In SB8 Glasses

The Department of Energy – Savannah River (DOE-SR) has provided direction to Savannah River Remediation (SRR) to maintain fissile concentration in glass below 897 g/m 3 . In support of that guidance, the Savannah River National Laboratory (SRNL) provided a technical basis and a supporting Microsoft® Excel® spreadsheet for the evaluation of fissile loading in Sludge Batch 5 (SB5), Sludge Batch 6 (SB6), Sludge Batch 7a (SB7a), and Sludge Batch 7b (SB7b) glass based on the iron (Fe) concentration in glass as determined by the measurements from the Slurry Mix Evaporator (SME) acceptability analysis. SRR has since requested that the necessary density information be provided to allow SRR to update the Excel® spreadsheet so that it may be used to maintain fissile concentration in glass below 897 g/m 3 during the processing of Sludge Batch 8 (SB8). One of the primary inputs into the fissile loading spreadsheet includes an upper bound for the density of SB8-based glasses. Thus, these bounding density values are to be used to assess the fissile concentration in this glass system. It should be noted that no changes are needed to the underlying structure of the Excel-based spreadsheet to support fissile assessments for SB8. However, SRR should update the other key inputs to the spreadsheet that are based on fissile and Fe concentrations reported from the SB8 Waste Acceptance Product Specification (WAPS) sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TH-CD-202-06: A Method for Characterizing and Validating Dynamic Lung Density Change During Quiet Respiration

Purpose: To obtain a functional relationship that calibrates the lung tissue density change under free breathing conditions through correlating Jacobian values to the Hounsfield units. Methods: Free-breathing lung computed tomography images were acquired using a fast helical CT protocol, where 25 scans were acquired per patient. Using a state-of-the-art deformable registration algorithm, a set of the deformation vector fields (DVF) was generated to provide spatial mapping from the reference image geometry to the other free-breathing scans. These DVFs were used to generate Jacobian maps, which estimate voxelwise volume change. Subsequently, the set of 25 corresponding Jacobian and voxel intensity in Hounsfield units (HU) were collected and linear regression was performed based on the mass conservation relationship to correlate the volume change to density change. Based on the resulting fitting coefficients, the tissues were classified into parenchymal (Type I), vascular (Type II), and soft tissue (Type III) types. These coefficients modeled the voxelwise density variation during quiet breathing. The accuracy of the proposed method was assessed using mean absolute difference in HU between the CT scan intensities and the model predicted values. In addition, validation experiments employing a leave-five-out method were performed to evaluate the model accuracy. Results: The computed mean model errors were 23.30±9.54 HU, 29.31±10.67 HU, and 35.56±20.56 HU, respectively, for regions I, II, and III, respectively. The cross validation experiments averaged over 100 trials had mean errors of 30.02 ± 1.67 HU over the entire lung. These mean values were comparable with the estimated CT image background noise. Conclusion: The reported validation experiment statistics confirmed the lung density modeling during free breathing. The proposed technique was general and could be applied to a wide range of problem scenarios where accurate dynamic lung density information is needed. This work was supported in part by NIH R01 CA0096679.

60 APPLIED LIFE SCIENCES↗

Quantum computer-enabled receivers for optical communication

Abstract Optical communication is the standard for high-bandwidth information transfer in today’s digital age. The increasing demand for bandwidth has led to the maturation of coherent transceivers that use phase- and amplitude-modulated optical signals to encode more bits of information per transmitted pulse. Such encoding schemes achieve higher information density, but also require more complicated receivers to discriminate the signaling states. In fact, achieving the ultimate limit of optical communication capacity, especially in the low light regime, requires coherent joint detection of multiple pulses. Despite their superiority, such joint detection receivers are not in widespread use because of the difficulty of constructing them in the optical domain. In this work we describe how optomechanical transduction of phase information from coherent optical pulses to superconducting qubit states followed by the execution of trained short-depth variational quantum circuits can perform joint detection of communication codewords with error probabilities that surpass all classical, individual pulse detection receivers. Importantly, we utilize a model of optomechanical transduction that captures non-idealities such as thermal noise and loss in order to understand the transduction performance necessary to achieve a quantum advantage with such a scheme. We also execute the trained variational circuits on an IBM-Q device with the modeled transduced states as input to demonstrate that a quantum advantage is possible even with current levels of quantum computing hardware noise.

97 MATHEMATICS AND COMPUTING↗