Search NASA⌕ Search

SEARCH · Search NASA

Results for “infrared detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Special Section Guest Editorial: Active Spectroscopy

A special edition of the journal Optical Engineering invited several scientists to participate in the editorial board of this special issue. The eleven papers in this special section cover recent developments in active spectroscopy, including new phenomenology and applications, advances in systems and components, and new methods for data processing and exploitation.

42 ENGINEERING↗

Models to Incorporate Reaction Mechanisms into DG-OSPREY: Fixed-Bed Simulations for Organic Iodides Capture Using Ag 0 Z

As one of the most potent radioisotopes released during spent nuclear fuel reprocessing, 129 I is strictly regulated and must be removed before discharge. Organic iodides (primarily alkyl iodides with different chain lengths, i.e., CH 3 I, C 4 H 9 I, and C 12 H 25 I) comprise ~2% of the total iodine in the reprocessing off-gases and are primarily present in vessel off-gas (VOG). Reduced silver mordenite (Ag 0 Z) is predominantly considered for the removal of radioiodine; however, its capture performance and underlying interaction processes with long-chain organic iodides are not fully understood. Two major tasks were accomplished in this study. First, to improve upon the previous experimental studies where Ag 0 Z was used to capture CH 3 I, C 4 H 9 I, and C 12 H 25 I at different concentrations, we comprehensively investigated the corresponding capture mechanisms by characterizing fully loaded Ag 0 Z samples. Second, computational codes were implemented to perform fixed-bed simulations that account for transport and reaction mechanisms. Scanning electron microscopy with energy dispersive X-ray analysis (SEM-EDX), powder X-ray diffraction (PXRD), UV-visible diffuse reflectance spectroscopy (UV-vis DRS), and thermogravimetric analysis (TGA) were conducted on Ag 0 Z samples that are saturated with I 2 , CH 3 I, C 4 H 9 I, and C 12 H 25 I), respectively. Results indicate that AgI is the predominant adsorption product regardless of the adsorbed iodine species, yet alkyl iodides with different carbon chain lengths may have different compositions of α- and γ-AgI. Synchrotron pair distribution function (PDF) measurements and TGA coupled with a Fourier transformed infrared detector (TGA FTIR) have been performed, and experimental data are currently analyzed. Results are expected to provide further insights into the adsorption mechanisms. The fixed-bed capture performance for CH 3 I was successfully simulated by solving mathematical equations that describe the underlying transport processes and adsorption reactions. The computational framework, Catalytic After Treatment System (CATS), that was originated in our research group, was used to solve the governing equations. Kinetic parameters, including the pore diffusivity and reaction rate constant were obtained by optimization techniques using data from thin-bed experiments performed at Oak Ridge National Laboratory. The performance of a deep bed predicted using the optimized parameters showed promising agreement with the experimental data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Correcting thermal-emission-induced detector saturation in infrared spectroscopy

We found that temperature-dependent infrared spectroscopy measurements (i.e., reflectance or transmittance) using a Fourier-transform spectrometer can have substantial errors, especially for elevated sample temperatures and collection using an objective lens. These errors can arise as a result of partial detector saturation due to thermal emission from the measured sample reaching the detector, resulting in nonphysical apparent reduction of reflectance or transmittance with increasing sample temperature. Here, we demonstrate that these temperature-dependent errors can be corrected by implementing several levels of optical attenuation that enable convergence testing of the measured reflectance or transmittance as the thermal-emission signal is reduced, or by applying correction factors that can be inferred by looking at the spectral regions where the sample is not expected to have a substantial temperature dependence.

47 OTHER INSTRUMENTATION↗

Quantum Anomalies in Condensed Matter

Quantum materials provide a fertile ground in which to test and realize unusual phenomena such as quantum anomalies predicted by quantum field theory. There are three important symmetries that are broken when classical field theory is moved into the quantum regime, the scale anomaly, the axial (chiral) anomaly, and the parity anomaly. Several potential device applications may be realized by the discovery of quantum anomalies in condensed matter, enabled by the new physics they embody, including ultra‐sensitive dark matter detectors, far infrared optical modulators, micro‐bolometric detectors, low‐dissipation ballistic transporters, terahertz‐based qubits, terahertz polarization state controls, passive magnetic field sensors, stable topological superconductors that host Majorana fermions, and qubits topologically protected against decoherence. In this perspective article, the definition of these quantum anomalies is laid out, how little is known in the context of condensed matter, and how quantum anomalies are predicted to manifest as anomalous electronic, thermal, and magnetic behavior in experiments on topological quantum materials, including Weyl and Dirac semimetals. Furthermore, the importance that mechanical strain and defects will play in modifying signatures of quantum anomalies is discussed.

36 MATERIALS SCIENCE↗

Superconducting nanowire single-photon detector enhanced near-infrared II portable confocal microscopy for tissue imaging with indocyanine green

In this Letter a novel, to our knowledge, approach for near-infrared (NIR) fluorescence portable confocal microscopy is introduced, aiming to enhance fluorescence imaging of biological samples in the NIR-II window. By integrating a superconducting nanowire single-photon detector (SNSPD) into a confocal microscopy, we have significantly leveraged the detection efficiency of the NIR-II fluorescence signal from indocyanine green (ICG), an FDA-approved dye known for its NIR-II fluorescence capabilities. The SNSPD, characterized by its extremely low dark count rate and optimized NIR system detection efficiency, enables the excitation of ICG with 1 mW and the capture of low-light fluorescence signals from deep regions (up to 512 µm). Consequently, our technique was able to produce high-resolution images of bio samples with a superior signal-to-noise ratio, making a substantial advancement in the field of fluorescence microscopy and offering a promising opportunity for future clinical study.

Liu, Yifan (ORCID:0000000328877704)↗

Quantum ghost imaging microscopy depth-of-field study

Quantum ghost imaging approaches have been proposed to enhance biological microscopy, for example, using 2D visible detectors to provide IR images or providing additional dimensions of spatial or spectral information. Toward the goal of making such imaging schemes practical, we compare image quality and depth-of-field between traditional images and ghost images at the same excitation levels. We measure how image quality and depth-of-field depend on the parameters of the entangled light produced using type-I spontaneous parametric down-conversion (SPDC). We use a pair of time-synchronized, photon-timing single-photon avalanche diode (SPAD) array detectors to capture two distinct microscope imaging paths simultaneously on a photon-pair-by-photon-pair basis: one in a traditional imaging pathway and the other a quantum ghost imaging pathway. We calculate the depth-of-field, resolution, contrast, and signal-to-noise ratio (SNR) through the parameter space of a β-Barium Borate (BBO) type-I bulk non-linear crystal length and angle. Our results provide a basis for choosing parameters for quantum ghost imaging with type-I SPDC sources.

47 OTHER INSTRUMENTATION↗

Room‐Temperature Mid‐Infrared Detection Using Metasurface‐Absorber‐Integrated Phononic Crystal Oscillator

Mid-infrared (MIR) detectors find extensive applications in chemical sensing, spectroscopy, communications, biomedical diagnosis, and space exploration. Alternative to semiconductor MIR photodiodes and bolometers, mechanical-resonator-based MIR detectors show advantages in higher sensitivity and lower noise at room temperature, especially toward longer wavelength infrared. Here, uncooled room-temperature MIR detectors based on lithium niobate surface acoustic wave phononic crystal (PnC) resonators integrated with wavelength-and-polarization-selective metasurface absorber arrays are demonstrated. The detection is based on the resonant frequency shift induced by the local temperature change due to MIR absorptions. The PnC resonator is configured in an oscillating mode, enabling active readout and low-frequency noise. The 1-GHz oscillator-based MIR detector shows a relative frequency deviation of 5.24 × 10 −10 Hz −1/2 at an integration time of 50 µs, leading to an incident noise equivalent power of 197 pW Hz −1/2 when input 6-µm MIR light is modulated at 1.8 kHz, and a large dynamic range of 10 7 in incident MIR power. The device architecture is compatible with the scalable manufacturing process and can be readily extended to a broader spectral range by tailoring the absorbing wavelengths of metasurface absorbers.

Xi, Zichen [Virginia Polytechnic Inst. and State U↗

Large active-area superconducting microwire detector array with single-photon sensitivity in the near-infrared

Superconducting nanowire single photon detectors (SNSPDs) are the highest-performing technology for time-resolved single-photon counting from the UV to the near-infrared. The recent discovery of single-photon sensitivity in micrometer-scale superconducting wires is a promising pathway to explore for large active area devices with application to dark matter searches and fundamental physics experiments. We present 8-pixel $1 mm^2$ superconducting microwire single photon detectors (SMSPDs) with $1\,\mathrm{\mu m}$-wide wires fabricated from WSi and MoSi films of various stoichiometries using electron-beam and optical lithography. Devices made from all materials and fabrication techniques show saturated internal detection efficiency at 1064 nm in at least one pixel, and the best performing device made from silicon-rich WSi shows single-photon sensitivity in all 8 pixels and saturated internal detection efficiency in 6/8 pixels. This detector is the largest reported active-area SMSPD or SNSPD with near-IR sensitivity published to date, and the first report of an SMSPD array. By further optimizing the photolithography techniques presented in this work, a viable pathway exists to realize larger devices with $cm^2$-scale active area and beyond.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing a robust sensor for infrared imaging bolometers

A new type of large area sensor for infrared imaging bolometers has been developed. It replaces the thin and fragile free-standing metal foils, which typically have been used, with a multi-layer coated sapphire (or diamond) substrate. Sapphire is transparent to mid-infrared wavelengths, is robust against transients, and can be thick enough to even be the vacuum window. The primary radiation absorber is still a thin deposited metal layer, but now it is partially insulated from the supporting sapphire substrate by a black (carbon-based) layer, which also acts as a blackbody remitter. Test results indicate 6× more noise equivalent power density (estimated NEPD = 23 W/m 2 at 5 ms camera exposure time, foil temperature decay time 60 ms) for a 2 μm gold-coated sapphire disk compared to estimated NEP = 4 W/m 2 at 1.8 ms exposure time, with foil decay time 420 ms, for a nominal 2.5 μm thick platinum-free-standing foil.

47 OTHER INSTRUMENTATION↗

Early High-contrast Imaging Results with Keck/NIRC2-PWFS: The SR 21 Disk

High-contrast imaging of exoplanets and protoplanetary disks depends on wave front sensing and correction made by adaptive optics instruments. Classically, wave front sensing has been conducted at optical wavelengths, which made high-contrast imaging of red targets such as M-type stars or extincted T Tauri stars challenging. Keck/NIRC2 has combined near-infrared (NIR) detector technology with the pyramid wave front sensor (PWFS). With this new module we observed SR 21, a young star that is brighter at NIR wavelengths than at optical wavelengths. Compared with the archival data of SR 21 taken with the optical wave front sensing we achieved ~20% better Strehl ratio in similar natural seeing conditions. Further post-processing utilizing angular differential imaging and reference-star differential imaging confirmed the spiral feature reported by the Very Large Telescope/Spectro-Polarimetric High-contrast Exoplanet REsearch instrument polarimetric observation, which is the first detection of the SR 21 spiral in total intensity at L' band. We also compared the contrast limit of our result (10 -4 at 0.'4 and 2 × 10 -5 at 1.'0) with the archival data that were taken with optical wave front sensing and confirmed the improvement, particularly at ≤0.'5. Our observation demonstrates that the NIR PWFS improves AO performance and will provide more opportunities for red targets in the future.

79 ASTRONOMY AND ASTROPHYSICS↗

Inert Gas Element as Active Infrared‐Absorption Source and Donor in Silicon for Forbidden‐Wavelength Sensing

Intrinsic silicon (Si) is forbidden for infrared (IR) sensing at the communication wavelength like 1.31 or 1.55 µm due to the well‐known bandgap limitation. In this work, an unexpected physical picture of using argon (Ar) is identified, which is usually inert to the surrounding chemical environment and used as a protective agent in semiconductor processing, to overcome the IR‐sensing‐forbidden problem in Si. Here, in this work, it is shown by an analysis of a dynamic secondary ion mass spectrometer that such a Si, when exposed to laser pulse in Ar gas, can contain a very high dose of Ar up to 10 20 cm −3 even after 1300 days. First‐principles calculations, molecular dynamics, and Hall effect measurements reveal that, due to both steric and dynamic repulsions by Ar orbitals to Si dangling bonds, the Ar‐filled‐vacancy produces a much wider defect band inside the gap, which is not only responsible for strong infrared absorption, but also causes a significant increase in n‐type conductivity, both in line with experiments. The study proves that originally inert elements in fact can act as active impurities in semiconductors for advanced applications, which updates the current knowledge of defect physics.

36 MATERIALS SCIENCE↗

Phase transformation and growth mechanism of RF sputtered ferroelectric lead scandium tantalate (PbSc 0.5 Ta 0.5 O 3 ) films

Lead scandium tantalate (PbSc 0.5 Ta 0.5 O 3 , PST), an order/disorder ferroelectric, is a potential candidate for electrocaloric cooling and pyroelectric infrared (IR) detector. In this work, we report the phase transformation kinetics from two series of samples containing pure amorphous and mixture of amorphous and pyrochlore to desired perovskite phase using postdeposition rapid thermal processing (RTP) as well as growth mechanism of RF sputtered PST thin films using excess lead target on platinized silicon (Pt/Ti/SiO 2 /Si) substrates. We find that small changes in the temperature ramp have a large effect on the degree of perovskite conversion (ferroelectric phase), orientation (crystallographic texture), and long-range order parameter (< S 111 >). Through isothermal annealing, we obtained optimal perovskite phase at ≥700°C temperature. The phase transformation is characterized by spontaneous formation of center-type in-plane radial rosette-like structures revealed by scanning electron microscopy. The PST perovskite crystallites were found to coexist with pyrochlore in RTP annealed films. The volume fractions for perovskite and pyrochlore phase were obtained from the analysis of “rosettes” and respective X-ray diffraction intensities which helped to determine various parameters associated with phase kinetics (n, k, and activation energy, Ea) and accompanying growth. The effective activation energies of perovskite transition and growth were found to be 332 ± 11 kJ/mol (345 ± 11 kJ/mol) and 114 ± 10 kJ/mol (122 ± 10 kJ/mol), respectively, for pure amorphous only (and mixed amorphous and pyrochlore) phase following nucleation-growth controlled Avrami's equation. A linear growth rate (n~1) for the perovskite phase indicates predominant interface-controlled process and diffusion-limited phenomena thus inhibiting rosette size owing to reactant depletion and soft impingement at the grain boundary. However, the growth behavior is isotropic in two-dimension parallel to the plane of the substrates for both sample series. Furthermore, lead loss was severe for in-situ growth and RTP combined with conventional furnace annealing than those of RTP only films, which were closer to stoichiometric albeit with excess lead and marginal oxygen vacancies (V o ).

36 MATERIALS SCIENCE↗

Dissolved Inorganic Carbon and Dissolved Organic Carbon Data for the East River Watershed, Colorado (2015-2025)

This data package contains mean values for dissolved organic carbon (DOC) and dissolved inorganic carbon (DIC) for water samples taken from the East River Watershed in Colorado. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. DOC and DIC concentrations in water samples were determined using a TOC-VCPH analyzer (Shimadzu Corporation, Japan). DOC was analyzed as non-purgeable organic carbon (NPOC) by purging HCl-acidified samples with carbon-free air to remove DIC prior to measurement. After the acidified sample has been sparged, it is injected into a combustion tube filled with oxidation catalyst heated to 680 oC. The DOC in samples is combusted to CO2 and measured by a non-dispersive infrared (NDIR) detector. The peak area of the analog signal produced by the NDIR detector is proportional to the DOC concentration of the sample. DIC was determined by acidifying the samples with HCl first, and then purging with carbon-free air to release CO2 for analysis by NDIR detector. Total dissolved nitrogen (TDN) was analyzed using a Shimadzu Total Nitrogen Module (TNM-L) combined with the TOC-L analyzer (Shimadzu Corporation, Japan). TNM-L is a non-specific measurement of total nitrogen (TN). All nitrogen species in samples are combusted to nitrogen monoxide and nitrogen dioxide, then reacted with ozone to form an excited state of nitrogen dioxide. Upon returning to ground state, light energy is emitted. Then, TDN is measured using a chemiluminescence detector. All data reported are the mean values upon minimum of three replicate measurements, with a relative standard deviation < 3%. All samples were analyzed under a rigorous quality assurance and quality control (QA/QC) process. This data package contains (1) a zip file (dic_npoc_data_2014-2025.zip) containing a total of 337 files: 336 data files of DIC and NPOC data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v6_20250901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v6_20250901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; and (4) PDF and docx files for the determiniation of Method Detection Limits (MDLs) for DIC and NPOC data, which has been updated in 2026-08. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 113 locations containing DIC/NPOC data. Update on 2020-10-07: Updated the data files to remove times from the timestamps, so that only dates remain. The data values have not changed. Update on 2021-04-11: Added Determination of Method Detection Limits (MDLs) for DIC, NPOC and TDN Analyses document, which can be accessed as a PDF or with Microsoft Word.Update on 6/10/2022: versioned updates to this dataset was made along with these changes: (1) updated dissolved inorganic carbon and dissolved organic carbon data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) restructure of units to comply with CSV reporting format requirements, (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-11-21. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Revised versions of the PDF and docx files for determination of MDLs for DIC and NPOC were added to replace previous versions. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available DIC and NPOC data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available DIC and NPOC data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-10, of the PDF and docx files for determination of MDLs for DIC and NPOC data were added to this dataset.

54 ENVIRONMENTAL SCIENCES↗

Technical Guidance on Use of the Netzsch LFA 447 Nanoflash for Measurement of Ceramic-Metallic (Cermet) Pellet Specimen

The Netzsch LFA 447 Nanoflash Instrument uses the laser flash method to measure thermal diffusivity of a material. Thermal conductivity can be determined if specific heat and density are known for that material. The 238 Pu Supply Program is interested in re-establishing the capability to determine thermal diffusivity and thermal conductivity of various 237Np Al/cermet samples during heating. The bottom side of a plane parallel sample is heated by an energy pulse from a light source (in this case a xenon lamp). An infrared (IR) detector is on the top side of the sample which detects the time dependent temperature rise of the sample due to the energy input from the xenon lamp. The LFA 447 Nanoflash is user-friendly, simple to operate, and has minor sample preparation which will allow technicians to be trained easily on its use. When using the multi-property measurement option, the LFA 447 Nanoflash can determine both thermal diffusivity and specific heat which means only density is needed to identify the thermal conductivity of a sample. This equipment is recognized for being highly accurate and having fast test times, replacing steady-state methods which have proven to be difficult and much slower.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of Total, Organic, and Inorganic Carbon and Total Nitrogen in Biological Cultures and Liquid Fraction Process Samples: Laboratory Analytical Procedure (LAP)

This Laboratory Analytical Procedure (LAP) describes the quantitative determination of total organic carbon, inorganic carbon in whole suspended biological samples and in the cell-free supernatant, by combustion and CO 2 detection with a non-dispersive infrared (NDIR) detector. This allows for distinct reporting of soluble and insoluble organic and inorganic carbon. In addition, this procedure covers the quantitative determination of soluble nitrogen in the cell-free supernatant.

09 BIOMASS FUELS↗

A Planetary Defense System For Responsive Space Missions

As King et al succinctly write, “Collision between the Earth and small objects in the solar system are known to occur regularly, and can result in extinction-level events at their most energetic or more commonly widespread loss of life or economic destruction even for relatively low-energy impacts.” Currently, the JPL Sentry System and the NASA NEO Surveyor mission track, identify, and monitor potential asteroid threats. The JPL Sentry System4 is an automated collision monitoring system which scans the current asteroid catalog for potential impact trajectories with Earth. A 2017 study led by P. Tricarico titled “The near-Earth asteroid population from two decades of observations” analyzes the combined observations of nine leading asteroid surveys. The NASA NEO Surveyor mission seeks to identify 90% of near-Earth objects (NEO) with diameters greater than 140 meters (460 feet) within 10 years. The NEO Surveyor combines data from two infrared imaging detectors to measure NEO size, composition, shape, rotational state, and orbits. Recently, the NASA Double Asteroid Redirection Test (DART) mission successfully altered the orbit of asteroid moon Dimorphos in 2022. This demonstrated that orbit alteration is possible. Thus, collisions between the Earth and asteroids are both likely and demonstrate potential for great harm. There is ongoing work to identify, catalog, and track potential threats. However, when a threat is identified there is not yet a system in place to target the threatening asteroid and defend the planet from potentially existential threats. Building on the DART Mission, we explore a planetary defense system to mitigate asteroid threats.

42 ENGINEERING↗