Search NASA⌕ Search

SEARCH · Search NASA

Results for “infrared hyperspectral”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Assimilation of Hyperspectral Infrared Radiances from the Cloud-Clearing Methodology: Results from the 2017 Atlantic Tropical Cyclone Season

Assimilation of cloud-affected radiances has the potential to dramatically improve numerical weather prediction systems, as has already been widely shown by use of all-sky microwave radiances. Assimilation of cloudy infrared (IR) radiances, however, lags far behind and only clear-sky radiances are used operationally, leaving data voids in dynamically sensitive areas, such as around tropical cyclones. This team has previously shown the positive benefit of assimilating cloud-cleared IR radiances from hyperspectral sensors (CCRs) and in this work applies the cloud-clearing methodology to generate fully customizable CCRs using an algorithm designed to be portable and reduce latency. These data are successfully assimilated in the Goddard Earth Observing System (GEOS) data assimilation system (DAS) for the 2017 Atlantic Hurricane season.

E L Mcgrath-Spangler↗

The Hyperspectral Infrared Imager (HyspIRI) Public Health & Air Quality Applications

The neglected tropical diseases (NTDs), a group of chronic, debilitating, and poverty-promoting parasitic, bacterial, and some viral and fungal infections, are among the most common causes of illness of the poorest people living in developing countries. Abiotic environmental factors are important in determining the distribution of disease-causing vectors and their life-cycles. HyspIRI observations can be merged through a Land Data Assimilation System (LDAS) be used to drive spatially-explicit ecological models of NTD vectors distribution & life cycles. Assimilations will be driven by observational data LDAS and satellite-derived meteorological forcing data, parameter datasets, and assimilation observations. HyspIRI hyperspectral measurements would provide global measurements of surface mineralogy and biotic crusts important in accessing the impact of dust in human health. HyspIRI surface thermal measurements would also help identify the variability of dust sources due to surface moisture conditions and map mineralogy.

Luvall, Jeffrey C.↗

The Hyperspectral Infrared Imager (HyspIRI) Public Health and Air Quality Applications

The neglected tropical diseases (NTDs), a group of chronic, debilitating, and poverty-promoting parasitic, bacterial, and some viral and fungal infections, are among the most common causes of illness of the poorest people living in developing countries. Abiotic environmental factors are important in determining the distribution of disease-causing vectors and their life-cycles. HyspIRI observations can be merged through a Land Data Assimilation System (LDAS) be used to drive spatially-explicit ecological models of NTD vectors distribution & life cycles. Assimilations will be driven by observational data LDAS and satellite-derived meteorological forcing data, parameter datasets, and assimilation observations. HyspIRI hyperspectral measurements would provide global measurements of surface mineralogy and biotic crusts important in accessing the impact of dust in human health. HyspIRI surface thermal measurements would also help identify the variability of dust sources due to surface moisture conditions and map mineralogy.

Luvall, Jeffrey C.↗

The Hyperspectral Infrared Imager (HyspIRI) Public Health and Air Quality Applications

The neglected tropical diseases (NTDs), a group of chronic, debilitating, and poverty-promoting parasitic, bacterial, and some viral and fungal infections, are among the most common causes of illness of the poorest people living in developing countries. Abiotic environmental factors are important in determining the distribution of disease-causing vectors and their life-cycles. HyspIRI observations can be merged through a Land Data Assimilation System (LDAS) be used to drive spatially-explicit ecological models of NTD vectors distribution & life cycles. Assimilations will be driven by observational data LDAS and satellite-derived meteorological forcing data, parameter datasets, and assimilation observations. HyspIRI hyperspectral measurements would provide global measurements of surface mineralogy and biotic crusts important in accessing the impact of dust in human health. HyspIRI surface thermal measurements would also help identify the variability of dust sources due to surface moisture conditions and map mineralogy.

Luvall, Jeffrey C.↗

The Hyperspectral Infrared Imager (HyspIRI) Public Health and Air Quality Applications

The neglected tropical diseases (NTDs), a group of chronic, debilitating, and poverty-promoting parasitic, bacterial, and some viral and fungal infections, are among the most common causes of illness of the poorest people living in developing countries. Abiotic environmental factors are important in determining the distribution of disease-causing vectors and their life-cycles. HyspIRI observations can be merged through a Land Data Assimilation System (LDAS) be used to drive spatially-explicit ecological models of NTD vectors distribution and life cycles. Assimilations will be driven by observational data LDAS and satellite-derived meteorological forcing data, parameter datasets, and assimilation observations. HyspIRI hyperspectral measurements would provide global measurements of surface mineralogy and biotic crusts important in accessing the impact of dust in human health. HyspIRI surface thermal measurements would also help identify the variability of dust sources due to surface moisture conditions and map mineralogy.

Luvall, Jeffrey C.↗

Hyperspectral Infrared Imaging of Flames Using a Spectrally Scanning Fabry-Perot Filter

The temperatures and compositions of gases in and around flames can be diagnosed using infrared emission spectroscopy to observe molecular band shapes and intensities. We have combined this approach with a low-order scanning Fabry-Perot filter and an infrared camera to obtain spectrally scanned infrared emission images of a laboratory flame and exhaust plume from 3.7 to 5.0 micrometers, at a spectral resolution of 0.043 micrometers, and a spatial resolution of 1 mm. The scanning filter or AIRIS (Adaptive Infrared Imaging Spectroradiometer) is a Fabry-Perot etalon operating in low order (mirror spacing = wavelength) such that the central spot, containing a monochromatic image of the scene, is viewed by the detector array. The detection system is a 128 x 128 liquid-nitrogen-cooled InSb focal plane array. The field of view is controlled by a 50 mm focal length multielement lens and an V4.8 aperture, resulting in an image 6.4 x 6.4 cm in extent at the flame and a depth of field of approximately 4 cm. Hyperspectral images above a laboratory CH4/air flame show primarily the strong emission from CO2 at 4.3 micrometers, and weaker emissions from CO and H2O. We discuss techniques to analyze the spectra, and plans to use this instrument in microgravity flame spread experiments.

Rawlins, W. T.↗

One-shot gas detection with transformer paired neural networks in Mako collected longwave infrared hyperspectral imagery

To date, careful data treatment workflows and statistical detectors are used to perform hyperspectral image (HSI) detection of any gas contained in a spectral library, which is often expanded with physics models to incorporate different spectral characteristics. In general, surrounding evidence or known gas-release parameters are used to provide confidence in or confirm detection capability, respectively. This makes quantifying detection performance difficult as it is nearly impossible to develop an absolute ground truth for gas target pixel presence in collected HSI. Consequently, developing and comparing new detection methods, especially machine learning (ML)-based methods, is susceptible to subjectivity in derived detection map quality. Here, in this work, we demonstrate the first use of transformer-based paired neural networks (PNNs) for one-shot gas target detection for multiple gases while providing quantitative classification and detection metrics for their use on labeled data. Terabytes of training data are generated from a database of long-wave infrared HSI obtained from historical Mako sensor campaigns over Los Angeles. By incorporating labels, singular signature representations, and a model development pipeline, we can tune and select PNNs to detect multiple gas targets that are not seen in training on a quantitative basis. We additionally assess our test set detections using interpretability techniques widely employed with ML-based predictors, but less common with detection methods relying on learned latent spaces.

Hyperspectral imaging↗

Accuracy of Vaisala RS41 and RS92 Upper Tropospheric Humidity Compared to Satellite Hyperspectral Infrared Measurements

Radiosondes are important for calibrating satellite sensors and assessing sounding retrievals. Vaisala RS41 radiosondes have mostly replaced RS92 in the Global Climate Observing System (GCOS) Reference Upper Air Network (GRUAN) and the conventional network. This study assesses RS41 and RS92 upper tropospheric humidity (UTH) accuracy by comparing with Infrared Atmospheric Sounding Interferometer (IASI) upper tropospheric water vapor absorption spectrum measurements. Using single RS41 and RS92 soundings at three GRUAN and DOE Atmospheric Radiation Measurement (ARM) sites and dual RS92/RS41 launches at three additional GRUAN sites, collocated with cloud-free IASI radiances (OBS), we compute Line-by-Line Radiative Transfer Model radiances for radiosonde profiles (CAL). We analyze OBS-CAL differences from 2015 to 2020, for daytime, nighttime, and dusk/dawn separately if data is available, for standard (STD) RS92 and RS41 processing, and RS92 GRUAN Data Processing (GDP; RS41 GDP is in development). We find that daytime RS41 (even without GDP) has ~1% smaller UTH errors than GDP RS92. RS41 may still have a dry bias of 1–1.5% for both daytime and nighttime, and a similar error for nighttime RS92 GDP, while standard RS92 may have a dry bias of 3–4%. These sonde humidity biases are probably upper limits since “cloud-free” scenes could still be cloud contaminated. Radiances computed from European Centre for Medium-Range Weather Forecasts (ECMWF) analyses match better than radiosondes with IASI measurements, perhaps because ECMWF assimilates IASI measurements. Relative differences between RS41 STD and RS92 GDP, or between radiosondes and ECMWF humidity profiles obtained from the radiance analysis, are consistent with their differences obtained directly from the RH measurements.

54 ENVIRONMENTAL SCIENCES↗

Hyperspectral Infrared Images of Terrain

Images at 128 wavelengths allow direct identification of many earth surface materials. Two reports describe advanced airborne spectrometer that creates images of terrain at many wavelengths. Airborne imaging spectrometer (AIS) produces two-dimensional images in 128 spectral bands in 1.2-to-2.4-micrometer wavelength region. Images created by 32-by-32 array of mercury cadmium telluride detector elements. Array views swath of Earth below moving aircraft. Used for agricultural, geological, and other surveys.

Vane, G.↗

Near-Infrared Hyperspectral Image Cubes of Mars during the 1999 Opposition

We used the Goddard Space Flight Center, Acousto-Optic Tunable Filter (AOTF) Camera to obtain near-IR spectral image sets of Mars over the 1.6-3.6 micron region during the April 1999 opposition. A complete image set consists of 280 images with a spectral full-width-half maximum of 10 wavenumbers (fixed in frequency), 90 images in H-band (1.55-1.80 micron), 115 images in K-band (1.95-2.50 micron) and 75 images in L-band (2.90-3.70 micron). The short-wavelength limit is set by transmission of AOTF cell and long-wavelength limit is imposed by sensitivity of PICNIC, 256x256, HgCdTe array detector. We will discuss the new array performance and provide preliminary interpretations of some of these results. These measurements were part of a 4-observatory coordinated effort whose overall objective was to assemble a photometrically calibrated, spectrally complete ground-based image cube over the visible and near-IR spectral region. To accomplish this, four observing teams conducted the investigations with instruments spanning 0.4 to 5.0 micron. The instruments and observing facilities were (a) AOTF camera at Apache Point Observatory, 3.5m, f/10, Nasymth focus (this abstract). Primary science targets included the 3 micron water-of hydration feature and CO2, H2O ice (polar regions and clouds); (b) Visible/NIR interference-filter (24 filters) camera at Lowell Observatory, 72" telescope. 430-1050 nm. Science targets were Fe(2+), Fe(3+) mineralogy and coarse grain hematite search; (c) NMSU Tortugas Mountain Observatory, 60 cm telescope, CCD photometry with same filter set as Lowell; (d) KPNO cryogenic grating/slit spectrometer (CRSP/SALLY) at KPNO 2.1 m, f/15 Cassegrain focus (see abstract by D. Glenar, et. al., this meeting). Selected wavelengths in 3-5 micron region (L, M band). Science targets included water-of-hydration feature (3-4 micron long wave extension) and sulfate mineralogy. Observers participating in this campaign included Dave Glenar, John Hillman, Gordon Bjoraker and Fred Espenak from GSFC, Nancy Chanover, Jim Murphy and A. S. MurTell from NMSU, Leslie Young from BU, Diana Blaney from JPL and Dick Joyce from KPNO.

Hillman, John J.↗

Lessons from 18 Years of Hyperspectral Infrared Sounder Data

By the end of 2013 NASA and EUMETSAT will have accumulated more than 11 years of AIRS, 6 years of IASI and one year of CrIS data. All three instruments were nominally specified to support the NWC for short term weather forecasting with a five year lifetime, but continue to exceed the accuracy requirement needed for weather forecasting alone. This allows use of their data for a much broader range of applications, including the calibration of broad-band instruments in space and climate research. We illustrate calibration aspects with examples from AIRS, IASI and CrIS using spatially uniform clear conditions, simultaneous nadir overpasses and random nadir samples. The differences between AIRS, IASI and CrIS for the purpose of weather forecasting are small and we expect that the excellent forecast impact demonstrated by the combination of AIRS and IASI will be continued by the combination of CrIS and IASI. Clear data are useful for calibration, but contain no climate signal. The analysis of random nadir samples from AIRS and CrIS identifies larger biases for observation of extreme conditions, represented by 1% and 99%tile data than for non-extreme observations. This is relevant for climate analysis. Resolution of these differences require further work, since they can complicate the continuation of trends established by AIRS with CrIS data, at least for extrema. The unequaled stability of the AIRS data allows us to evaluate trends using random nadir sampled data. We see an increasing frequency in severe storms over land, a decreasing frequency over ocean. The 11 years of AIRS data are too short to tell if these trends are significant from a climate change viewpoint, or if they are parts of multi-decadal oscillations.

CRIS↗

An Anomaly Correlation Skill Score for the Evaluation of the Performance of Hyperspectral Infrared Sounders

With the availability of very accurate forecasts, the metric of accuracy alone for the evaluation of the performance of a retrieval system can produce misleading results. A useful characterization of the quality of a retrieval system and its potential to contribute to an improved weather forecast is its skill, which we define as the ability to make retrievals of geophysical parameters which are closer to the truth than the six hour forecast, when the truth differs significantly from the forecast. We illustrate retrieval skill using one day of AMSU and AIRS data with three different retrieval algorithms, which result in retrievals for more than 90% of the potential retrievals under clear and cloudy conditions. Two of the three algorithms have better than 1 K rms "RAOB quality" accuracy on the troposphere, but only one has skill between 900 and 100 mb. AIRS was launched on the EOS Aqua spacecraft in May 2002 into a 705 km polar sun-synchronous orbit with accurately maintained 1:30 PM ascending node. Essentially uninterrupted data are freely available since September 2002.

retrieval↗