Search NASA⌕ Search

SEARCH · Search NASA

Results for “input device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Optical-data-processing properties of a liquid-crystal television spatial light modulator

The potential of an extremely inexpensive liquid-crystal television (LCTV) as a two-dimensional spatial light modulator has been investigated. The LCTV modulates the transmission of coherent or incoherent light and can either be electronically addressed through a microcomputer or optically addressed with a TV camera. The transmission characteristics of the device have been measured, its diffraction pattern is examined, and its use as an input device for an optical correlator is tested. It is discovered that, with proper modifications, it has potential for optical-data-processing applications.

Liu, H.-K.↗

Experimental boundary integral equation applications in speckle interferometry

A complete data analysis system utilizing laser speckle interferometry and Experimental Integral Equation Method (EBIE) is described. A host computer provides the optical data analysis and serves as an input device to a PDP11/VAX computer for numerical analysis. The basic theory of pointwise filtering and digital correlation is described as experimental data input to the BIE method.

Fraley, J. E.↗

User interface devices for mission control

The Mission Control Center (MCC) at Johnson Space Center (JSC) in Houston, Texas, is being upgraded with new technology engineering/scientific workstations. These workstations will replace the existing consoles and will emulate the present hardware input and display media. The workstations will be using new and different input devices for the flight controller to interact with the workstation and mainframes. This paper presents the results of the User Interface survey conducted by the Workstation Prototype Lab (WPL). The WPL offered the opportunity for users to do hands-on evaluations of a number of user interface options prototyped by lab personnel.

Boatman, Wayne↗

Kinesthetic coupling between operator and remote manipulator

A universal force-reflecting hand controller has been developed which allows the establishment of a kinesthetic coupling between the operator and a remote manipulator. The six-degree-of-freedom controller was designed to generate forces and torques on its three positional and three rotational axes in order to permit the operator to accurately feel the forces encountered by the manipulator and be as transparent to operate as possible. The universal controller has been used in an application involving a six-degree-of-freedom mechanical arm equipped with a six-dimensional force-torque sensor at its base. In this application, the hand controller acts as a position control input device to the arm, while forces and torques sensed at the base of the mechanical hand back drive the hand controller. The positional control relation and the back driving of the controller according to inputs experienced by the force-torque sensor are established through complex mathematical transformations performed by a minicomputer. The hand controller is intended as a development tool for investigating force-reflecting master-slave manipulator control technology.

Bejczy, A. K.↗

Determining Desirable Cursor Control Device Characteristics for NASA Exploration Missions

A test battery was developed for cursor control device evaluation: four tasks were taken from ISO 9241-9, and three from previous studies conducted at NASA. The tasks focused on basic movements such as pointing, clicking, and dragging. Four cursor control devices were evaluated with and without Extravehicular Activity (EVA) gloves to identify desirable cursor control device characteristics for NASA missions: 1) the Kensington Expert Mouse, 2) the Hulapoint mouse, 3) the Logitech Marble Mouse, and 4) the Honeywell trackball. Results showed that: 1) the test battery is an efficient tool for differentiating among input devices, 2) gloved operations were about 1 second slower and had at least 15% more errors; 3) devices used with gloves have to be larger, and should allow good hand positioning to counteract the lack of tactile feedback, 4) none of the devices, as designed, were ideal for operation with EVA gloves.

Sandor, Aniko↗

Low noise parametric amplifiers for radio astronomy observations at 18-21 cm wavelength

The principle characteristics and use of SHF parametric amplifiers for radiometer input devices are explored. Balanced parametric amplifiers (BPA) are considered as the SHF signal amplifiers allowing production of the amplifier circuit without a special filter to achieve decoupling. Formulas to calculate the basic parameters of a BPA are given. A modulator based on coaxial lines is discussed as the input element of the SHF. Results of laboratory tests of the receiver section and long-term stability studies of the SHF sector are presented.

Kanevskiy, B. Z.↗

Advanced display object selection methods for enhancing user-computer productivity

The User-Interface Technology Branch at NCCOSC RDT&E Division has been conducting a series of studies to address the suitability of commercial off-the-shelf (COTS) graphic user-interface (GUI) methods for efficiency and performance in critical naval combat systems. This paper presents an advanced selection algorithm and method developed to increase user performance when making selections on tactical displays. The method has also been applied with considerable success to a variety of cursor and pointing tasks. Typical GUI's allow user selection by: (1) moving a cursor with a pointing device such as a mouse, trackball, joystick, touchscreen; and (2) placing the cursor on the object. Examples of GUI objects are the buttons, icons, folders, scroll bars, etc. used in many personal computer and workstation applications. This paper presents an improved method of selection and the theoretical basis for the significant performance gains achieved with various input devices tested. The method is applicable to all GUI styles and display sizes, and is particularly useful for selections on small screens such as notebook computers. Considering the amount of work-hours spent pointing and clicking across all styles of available graphic user-interfaces, the cost/benefit in applying this method to graphic user-interfaces is substantial, with the potential for increasing productivity across thousands of users and applications.

Osga, Glenn A.↗

Test and evaluation of a multifunction keyboard and a dedicated keyboard for control of a flight management computer

A flight management computer (FMC) control display unit (CDU) test was conducted to compare two types of input devices: a fixed legend (dedicated) keyboard and a programmable legend (multifunction) keyboard. The task used for comparison was operation of the flight management computer for the Boeing 737-300. The same tasks were performed by twelve pilots on the FMC control display unit configured with a programmable legend keyboard and with the currently used B737-300 dedicated keyboard. Flight simulator work activity levels and input task complexity were varied during each pilot session. Half of the points tested were previously familiar with the B737-300 dedicated keyboard CDU and half had no prior experience with it. The data collected included simulator flight parameters, keystroke time and sequences, and pilot questionnaire responses. A timeline analysis was also used for evaluation of the two keyboard concepts.

Crane, J. M.↗

User friendly joystick

A joystick control device having a lower U-shaped bracket, an upper U-shaped bracket, a handle attached to the upper U-shaped bracket, with the upper U-shaped bracket connected to the lower U-shaped bracket by a compliant joint allowing six degrees of freedom for the joystick. The compliant joint consists of at least one cable segment affixed between the lower U-shaped bracket and the upper U-shaped bracket. At least one input device is located between the lower U-shaped bracket and the upper U-shaped bracket.

Eklund, Wayne D.↗

Pilot interface with fly by wire control systems

Aircraft designers are rapidly moving toward full fly by wire control systems for transport aircraft. Aside from pilot interface considerations such as location of the control input device and its basic design such as side stick, there appears to be a desire to change the fundamental way in which a pilot applies manual control. A typical design would have the lowest order of manual control be a control wheel steering mode in which the pilot is controlling an autopilot. This deprives the pilot of the tactile sense of angle of attack which is inherent in present aircraft by virtue of certification requirements for static longitudinal stability whereby a pilot must either force the aircraft away from its trim angle of attack or trim to a new angle of attack. Whether or not an aircraft actually has positive stability, it can be made to feel to a pilot as though it does by artificial feel. Artificial feel systems which interpret pilot input as pitch rate or G rate with automatic trim have proven useful in certain military combat maneuvers, but their transposition to other more normal types of manual control may not be justified.

Melvin, W. W.↗

Performance Effects of Display Incogruity in a Digital and Analog Clock Reading Task

In an era of increasing automation, it is important to design displays and input devices that minimize human error. In this context, information concerning the human response to the detection of incongruous information is important. Such incongruous information can be operationalized as unexpected (perhaps erroneous) information on which a decision by the human or operation by an automated system is based. In the aviation environment, decision making when faced with inadequate, incomplete, or incongruous information may occur in a failure scenario. An additional challenge facing the human operator in automated environments is maintaining alertness or vigilance. The vigilance issue is of particular concern as a factor that may interact with performance when faced with inadequate, incomplete, or incongruous information. From the literature on eye-scan behavior we know that the time spent looking at a particular display or indicator is a function of the type of information one is trying to discern from the display. For example, quick glances are all it takes for confirming that an indicator is in a normal position or range, whereas a continuous look of several seconds may be required for confirmation that a complex control input is having the desired effect. Important to consider is that while an extended look takes place, visual input from other sources may be missed. Much like an extended look, the interpretation of incongruous information may require extra time. The present experiment was designed to explore the performance consequences of a decision making task when incongruous information was presented. For this experiment a display incongruity was created on a subset of trials of a clock reading laboratory task. Display incongruity was made possible through presentation of 'impossible' times (e.g. 1:65 or 11:90). Subjects made 'same' 'different' decisions and keyboard responses to pairings of Analog-Analog (AA), Digital-Digital (DD), and Analog- Digital (AD), display combinations. For trials during which display incongruities were not presented, based on prior research comparing digital and analog clock displays, it would be expected that the Digital-Digital condition would result in the shortest response times and the Analog-Analog and Analog-Digital conditions would have longer response times. The performance consequence expected on trials with incongruous times would be very long response times.

J. Raymond Comstock, Jr.↗

APOLLO: a facility-scale differentiable virtual accelerator for Fermilab

As the design complexity of modern accelerators grows, there is more interest in using advanced simulations that have fast execution time or yield additional insights like gradients. The FAST/IOTA facility has been working on implementing and experimentally validating an end-to-end digital twin that is both fast and gradient-aware, allowing for rapid prototyping of new software and experiments with minimal beam time costs. Our framework integrates physics and ML codes for linac and ring simulation through a set of generic interfaces between surrogate and physics-based sections. To reproduce device inputs and outputs, system state is exposed as a deterministic discrete event simulator. Because Fermilab is undergoing control system transition, both EPICS and ACNET frontends are supported. Recently, we have begun transitioning to a new community lattice standard, PALS, as well as developing standardized infrastructure for data ingest and normalization to prepare for model calibration during FAST proton injector commissioning. We discuss implementation details as well as challenges, and future plans to extend modelling to main complex proton accelerators like PIPII and Booster.

Kuklev, Nikita [Fermilab]↗

Removal of Non-Specifically Bound Proteins Using Rayleigh Waves Generated on ST-Quartz Substrates

Label-free biosensors are plagued by the issue of non-specific protein binding which negatively affects sensing parameters such as sensitivity, selectivity, and limit-of-detection. In the current work, we explore the possibility of using the Rayleigh waves in ST-Quartz devices to efficiently remove non-specifically bound proteins via acoustic streaming. A coupled-field finite element (FE) fluid structure interaction (FSI) model of a surface acoustic wave (SAW) device based on ST-Quartz substrate in contact with a liquid loading was first used to predict trends in forces related to SAW-induced acoustic streaming. Based on model predictions, it is found that the computed SAW body force is sufficient to overcome adhesive forces between particles and a surface while lift and drag forces prevent reattachment for a range of SAW frequencies. We further performed experiments to validate the model predictions and observe that the excitation of Rayleigh SAWs removed non-specifically bound (NSB) antigens and antibodies from sensing and non-sensing regions, while rinsing and blocking agents were ineffective. An amplified RF signal applied to the device input disrupted the specific interactions between antigens and their capture antibody as well. ST-quartz allows propagation of Rayleigh and leaky SH-SAW waves in orthogonal directions. Thus, the results reported here could allow integration of three important biosensor functions on a single chip, i.e., removal of non-specific binding, mixing, and sensing in the liquid phase.

59 BASIC BIOLOGICAL SCIENCES↗

Software approach to automatic patching of analog computer

The Automatic Patching Verification program (APV) is described which provides the hybrid computer programmer with a convenient method of performing a static check of the analog portion of his study. The static check insures that the program is patched as specified, and that the computing components being used are operating correctly. The APV language the programmer uses to specify his conditions and interconnections is similar to the FORTRAN language in syntax. The APV control program reads APV source program statements from an assigned input device. Each source program statement is processed immediately after it is read. A statement may select an analog console, set an analog mode, set a potentiometer or DAC, or read from the analog console and perform a test. Statements are read and processed sequentially. If an error condition is detected, an output occurs on an assigned output device. When an end statement is read, the test is terminated.

Source record↗

PLZT block data composers operated in differential phase mode

The use of PLZT ceramics with the 7/65/35 composition in block data composer (BDC) input devices for holographic memory systems has previously been described for operation in the strain biased, scattering, and edge effect modes. A new and promising mode of BDC operation is the differential phase mode in which each element of a matrix array BDC acts as a phase modulator. The phase modulation results from a phase difference in the optical path length between the electrically poled and depoled states of the PLZT. It is shown that a PLZT BDC can be used as a matrix-type phase modulator to record and process digital data by the differential phase mode in a holographic recording/processing system with readout contrast ratios of between 10:1 and 15:1. The differential phase mode has the advantages that strain bias is not required and that the thickness and strain variations in the PLZT are cancelled out.

Drake, M. D.↗

A semi-automated system for plotting and computer cataloging of remote sensing imagery

Description of a computer-assisted system for plotting and descriptor-cataloging of aerial imagery - an ingredient of the aerial image data handling system of the NASA Earth Resources Aircraft Project (ERAP). The system under consideration uses two graphic tablets linked interactively with a digital computer as input devices for deriving frame coordinates by correlating image points to map points. The various software programs and operating modes facilitate a semiautomatic plotting of an image by selecting two or more points within the image for matching with map details. The computer performs the scaling and orientation transformations for the calculation of the center and corner coordinates of the frame. Twenty five other descriptors for each frame are fed into a computerized data base requiring a minimum operator's time for verification and correction.

Gnauck, G. E.↗

The development of an engineering computer graphics laboratory

Hardware and software systems developed to further research and education in interactive computer graphics were described, as well as several of the ongoing application-oriented projects, educational graphics programs, and graduate research projects. The software system consists of a FORTRAN 4 subroutine package, in conjunction with a PDP 11/40 minicomputer as the primary computation processor and the Imlac PDS-1 as an intelligent display processor. The package comprises a comprehensive set of graphics routines for dynamic, structured two-dimensional display manipulation, and numerous routines to handle a variety of input devices at the Imlac.

Anderson, D. C.↗

Space Shuttle Dynamic Integrated Tests - Concept and results for STS-1

It is pointed out that ground tests, which involve end-to-end checks of various subsystems often by stimulating an input device and examining the resultant effect, do not exercise dynamically all subsystem interactions encountered during a real flight. The development and implementation of the Dynamic Integrated Test (DIT) for the Space Transportation System, patterned on the ASIST (Avionics System Integration Self Test) concept, are examined. It is noted that the complete hardware-software data paths which are utilized in flight simply do not exist until the vehicle is assembled. The integrated test is considered necessary in order to verify the integrity of these paths, that is, to establish that proper connections have been made, that correct polarity is maintained, and that no unexpected interference is generated. As a result of four tests carried out on the Space Transportation System, hardware and software problems, both on-board the vehicle and within the launch support complex, were identified and resolved. Significant return was also realized in the training of the launch and flight crews.

Brody, S.↗