Search NASASearch

SEARCH · Search NASA

Results for “interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Interferometer for Testing in Vibration Environments

Temporal phase shifting interferometers require a stable environment during the data acquisition, so that well controlled phase steps can be introduced between successively acquired interferograms. In contrast, single-frame interferometers need to acquire only one interferogram to provide a phase map with very good precision at high spatial resolution. Thus these interferometers are well suited for the interferometric testing of large optics with long radius of curvature for which vibration isolation is difficult, eg. testing astronomical telescope mirrors in a test tower, or testing space optics inside a cryogenic vacuum chamber. This paper describes the Instantaneous Phase Interferometer (IPI) by ADE Phase Shift, together with measurement results at NASA. The IPI consists of a polarization Twyman-Green interferometer operating at 632.8 nm, with single-frame data acquisition based on a spatial carrier technique. The spatial carrier fringes are generated by introducing large amount of tilt between the test beam and the reference beam. The phase information of the optical surface under test is encoded in the straightness of the interference fringes, which can be detected in a single frame with spatial sampling of 1000 x 1000 pixels. Measurements taken at the NASA Marshall Space Flight Cater in support of the characterization of developmental optics for the Next Generation Space Telescope are presented. Such tests consist of a mirror placed inside a cryogenic vacuum chamber, with the IPI placed outside the test chamber without any additional vibration isolation.

Eng, Ron

Solar Confocal Interferometers for Sub-Picometer-Resolution Spectral Filters

The confocal Fabry-Perot interferometer allows sub-picometer spectral resolution of Fraunhofer line profiles. Such high spectral resolution is needed to keep pace with the higher spatial resolution of the new set of large-aperture solar telescopes. The line-of-sight spatial resolution derived for line profile inversions would then track the improvements of the transverse spatial scale provided by the larger apertures. The confocal interferometer's unique properties allow a simultaneous increase in both etendue and spectral power. Methods: We have constructed and tested two confocal interferometers. Conclusions: In this paper we compare the confocal interferometer with other spectral imaging filters, provide initial design parameters, show construction details for two designs, and report on the laboratory test results for these interferometers, and propose a multiple etalon system for future testing of these units and to obtain sub-picometer spectral resolution information on the photosphere in both the visible and near-infrared.

Gary, G. Allen

Structural-Thermal-Optical-Performance (STOP) Model Development and Analysis of a Field-widened Michelson Interferometer

An integrated Structural-Thermal-Optical-Performance (STOP) model was developed for a field-widened Michelson interferometer which is being built and tested for the High Spectral Resolution Lidar (HSRL) project at NASA Langley Research Center (LaRC). The performance of the interferometer is highly sensitive to thermal expansion, changes in refractive index with temperature, temperature gradients, and deformation due to mounting stresses. Hand calculations can only predict system performance for uniform temperature changes, under the assumption that coefficient of thermal expansion (CTE) mismatch effects are negligible. An integrated STOP model was developed to investigate the effects of design modifications on the performance of the interferometer in detail, including CTE mismatch, and other three- dimensional effects. The model will be used to improve the design for a future spaceflight version of the interferometer. The STOP model was developed using the Comet SimApp'TM' Authoring Workspace which performs automated integration between Pro-Engineer®, Thermal Desktop®, MSC Nastran'TM', SigFit'TM', Code V'TM', and MATLAB®. This is the first flight project for which LaRC has utilized Comet, and it allows a larger trade space to be studied in a shorter time than would be possible in a traditional STOP analysis. This paper describes the development of the STOP model, presents a comparison of STOP results for simple cases with hand calculations, and presents results of the correlation effort to bench-top testing of the interferometer. A trade study conducted with the STOP model which demonstrates a few simple design changes that can improve the performance seen in the lab is also presented.

Scola, Salvatore J.

Laser-Guided Space Interferometer

The mirrors of astronomical interferometers need to be aligned within a fraction of a wavelength relative to one another. This would be especially challenging for optical instruments with mirrors separated by hundreds of meters flying in Earth’s orbit. However, in this work, we show that this alignment can be achieved by means of: (i) flying the mirror cluster in a particular orbital configuration; (ii) closing a coarse positioning loop using GNSS (Global Navigation Satellite System); and (iii) closing a fine wavefront-control loop using light from a laser guide star. The orbital configuration is designed to keep the mirrors passively pointing at the target star (up to a small orbital perturbation) while the interferometer cluster is orbiting and changing its baseline. The laser guide star would be flying in the same orbit but in the opposite direction. In medium- or high-Earth orbit, the interferometer would be able to observe a star for several hours per orbit. In this work, we analyzed the performance of an optical space interferometer consisting of nine 20 cm mirrors mounted on CubeSats and flying 3 km apart (together with a combiner and a laser guide star small satellite). This configuration supports a resolution of 0.04 milliarcseconds - an order of magnitude better than current ground-based interferometers. We estimate the performance of this system imaging stellar surfaces assuming perfect wavefront estimation and control.

Leonid Pogorelyuk

The StarLight Space Interferometer: Optical design and performance modeling

The StarLight mission aimed to place the first formation flying optical interferometer into space in year 2006. Utilizing two spacecraft to form a long baseline Michelson interferometer, it would measure white light fringes on a number of partially resolved stars of magnitudes >5 in the wavelength range 600 to 1000nm. The interferometer baseline is variable between 30 and 125 m, and also has a fixed 1 m mode. The spacecraft are flown in a parabolic geometry which requires an optical delay line to build up more than 14m of delay on one arm of the interferometer. To obtain high fringe visibility, starlight wavefront, pointing and intensity must be preserved through 22 reflections from mirrors and beamsplitters. The alignment of a total of 27 optics is maintained through careful thermal design and the use of two actuated mirrors on each arm. This paper describes the optical layout in depth, including the beam combiner design which allows star tracking, optical system alignment and fringe formation on a single CCD. The effects of diffraction of the starlight transferred from a distant spacecraft and from optical surface imperfections are modeled. Other contributors to the visibility budget and the resulting variation of fringe visibility across the focal plane are discussed .

StarLight

Polarization mismatch errors in radio phase interferometers.

An analysis is presented which deals with the effects of polarization mismatch errors on the accuracy of a phase interferometer used for position location of unknown emitters relative to known calibration emitters. Closed-form expressions for the induced phase difference between interferometer antennas are derived for several combinations of receiving and transmitting antenna polarizations. Errors contributed by mechanical misalignment between antennas, as well as effects of power loss attributable to polarization mismatch, are also considered. The analysis leads to the conclusion that circularly polarized interferometer and transmitter antennas are best suited for the position location application, if it is assumed that polarization tracking of the interferometer antennas is not available. It is shown that a reasonable amount of ellipticity can be tolerated before the phase error becomes significant.

Muehldorf, E. I.

Spherical lamellar grating interferometer for airborne astronomical observations of far infrared objects

A lamellar-grating interferometer designed for airborne IR astronomy is described, and its response to a laboratory far-IR source and to Jupiter as viewed from NASA's Kuiper Airborne Observatory is discussed. The theory of lamellar-grating interferometers is reviewed, advantages over Michelson interferometers are noted, and the optical arrangement for the lamellar-grating instrument is indicated. The response of the instrument is illustrated using purged and unpurged spectra of a 1000-K blackbody source as well as a raw spectrum of Jupiter containing many absorption features (probably telluric) identified with rotation bands of H2O. It is noted that the interferometer's self-collimation allows for efficient operation with a minimum of auxiliary optics.

Pipher, J. L.

An orbiting infrared interferometer to search for nonsolar planets

This paper proposes an orbiting infrared interferometer with its fringe null centered on a nearby star at a distance of say 10 parsecs. A large planet ('Jupiter') would have an angular separation from the star of about 0.5 arcsec. To have a fringe crest on the planet, a fringe period of 1.0 arcsec is needed and at 40 microns the required baseline is 8 m. Spinning the interferometer about the line of sight to the star results, even with pointing errors, in a relatively slowly varying but strongly suppressed stellar output and a more rapidly varying fringe-like planetary signal rich in higher harmonics. For pointing errors up to .050 arcsec the planet's fourth harmonic greatly exceeds that from the star, thereby relaxing interferometer pointing tolerances. Indeed, it appears that the limiting factor is zodiacal infrared background radiation and not the intense localized stellar flux which can effectively be eliminated by the fringe null of the spinning infrared interferometer.

Macphie, R. H.

Alignment of a two-beam interferometer

Two beam interferometers have been proposed for space applications such as sensing the shape of a large antenna. Since alignment and adjustment of interferometers have long been considered difficult laboratory tasks, the question of making their operation sufficiently automatic for space applications is a serious one. As a first step in addressing this question certain manual procedures, which may not be well known, have been collected from widely scattered sources. These techniques are illustrated by two examples: (1) the alignment of a Mach-Zehnder interferometer and the adjustment of fringe location. (2) The adjustment of a Michelson interferometer for zero path difference (white light fringes).

Tubbs, E. F.

Special relativity and interferometers

A new generation of gravitational wave detectors is expected to be based on interferometers. Yurke et al. (1986) introduced a class of interferometers characterized by SU(1,1) which can in principle achieve a phase sensitivity approaching 1/N, where N is thte total number of photons entering the interferometer. It is shown here that the SU(1,1) interferometer can serve as an analog computer for Wigner's little group of the Poincare\'| group.

Han, D.

Optical diameters of stars measured with the Mt. Wilson Mark III interferometer

Reliable stellar angular diameters can now be determined using the Mark III Optical Interferometer located on Mt. Wilson, California. The Mark III is a Michelson Interferometer capable of measuring the interferometric fringe visibility for stars using interferometer baselines varying from 3 to 31.5 meters in length. Angular diameters measured with the Mark III Optical Interferometer are presented for 12 stars at wavelengths of 450 and 800 nm.

Simon, R. S.

HARDI: A high angular resolution deployable interferometer for space

We describe here a proposed orbiting interferometer covering the UV, visible, and near-IR spectral ranges. With a 6-m baseline and a collecting area equivalent to about a 1.4 m diameter full aperture, this instrument will offer significant improvements in resolution over the Hubble Space Telescope, and complement the new generation of ground-based interferometers with much better limiting magnitude and spectral coverage. On the other hand, it has been designed as a considerably less ambitious project (one launch) than other current proposals. We believe that this concept is feasible given current technological capabilities, yet would serve to prove the concepts necessary for the much larger systems that must eventually be flown. The interferometer is of the Fizeau type. It therefore has a much larger field (for guiding) better UV throughout (only 4 surfaces) than phased arrays. Optimize aperture configurations and ideas for the cophasing and coalignment system are presented. The interferometer would be placed in a geosynchronous or sunsynchronous orbit to minimize thermal and mechanical disturbances and to maximize observing efficiency.

Bely, Pierre Y.

Measured optical performance of three Fabry-Perot interferometers for use in a tunable ultraviolet filter

A narrowband ultraviolet (UV) filter would allow the first monochromatic two-dimensional images of astrophysical plasmas to be obtained in UV emission lines. The high etendue and spectral resolving power of the Fabry-Perot (FP) interferometer make it an excellent candidate for use in a tunable UV filter, provided that adequate optical performance can be obtained. Laboratory measurements of three UV FP interferometers with progressively greater dielectric mirror reflectances are described. The measurements demonstrate the adequate reflectivity, absorption, and small-scale smoothness of currently available coatings and substrates for UV interferometry. The measurements are conducted at 228.8 nm utilizing a cadmium hollow cathode light source. The best performing interferometer has a finesse of 41 and maximum transmittance of 0.38 over a coating-performance-dominated 3-mm-diam subaperture and a finesse of 26 and maximum transmittance of 0.32 over a parabolic-defect-dominated 30-mm-diam aperture. This interferometer is well suited for use in a UV filter system.

Korendyke, Clarence M.

Stellar Interferometer Technology Experiment (SITE)

The MIT Space Engineering Research Center and the Jet Propulsion Laboratory stand ready to advance science sensor technology for discrete-aperture astronomical instruments such as space-based optical interferometers. The objective of the Stellar Interferometer Technology Experiment (SITE) is to demonstrate system-level functionality of a space-based stellar interferometer through the use of enabling and enhancing Controlled-Structures Technologies (CST). SITE mounts to the Mission Peculiar Experiment Support System inside the Shuttle payload bay. Starlight, entering through two apertures, is steered to a combining plate where it is interferred. Interference requires 27 nanometer pathlength (phasing) and 0.29 archsecond wavefront-tilt (pointing) control. The resulting 15 milli-archsecond angular resolution exceeds that of current earth-orbiting telescopes while maintaining low cost by exploiting active optics and structural control technologies. With these technologies, unforeseen and time-varying disturbances can be rejected while relaxing reliance on ground alignment and calibration. SITE will reduce the risk and cost of advanced optical space systems by validating critical technologies in their operational environment. Moreover, these technologies are directly applicable to commercially driven applications such as precision matching, optical scanning, and vibration and noise control systems for the aerospace, medical, and automotive sectors. The SITE team consists of experienced university, government, and industry researchers, scientists, and engineers with extensive expertise in optical interferometry, nano-precision opto-mechanical control and spaceflight experimentation. The experience exists and the technology is mature. SITE will validate these technologies on a functioning interferometer science sensor in order to confirm definitely their readiness to be baselined for future science missions.

Crawley, Edward F.

Liquid crystal point diffraction interferometer

A new instrument, the liquid crystal point diffraction-interferometer (LCPDI), has been developed for the measurement of phase objects. This instrument maintains the compact, robust design of Linnik's point diffraction interferometer (PDI) and adds to it phase stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wavefronts with very high data density and with automated data reduction. This dissertation describes the theory of both the PDI and liquid crystal phase control. The design considerations for the LCPDI are presented, including manufacturing considerations. The operation and performance of the LCPDI are discussed, including sections regarding alignment, calibration, and amplitude modulation effects. The LCPDI is then demonstrated using two phase objects: defocus difference wavefront, and a temperature distribution across a heated chamber filled with silicone oil. The measured results are compared to theoretical or independently measured results and show excellent agreement. A computer simulation of the LCPDI was performed to verify the source of observed periodic phase measurement error. The error stems from intensity variations caused by dye molecules rotating within the liquid crystal layer. Methods are discussed for reducing this error. Algorithms are presented which reduce this error; they are also useful for any phase-stepping interferometer that has unwanted intensity fluctuations, such as those caused by unregulated lasers.

Mercer, Carolyn R.

First Results of the TOPSAR C-Band / L-Band Interferometer: Calibration and Differential Penetration

The NASA/JPL TOPSAR instrument recently was extended from a single wavelength C-band dual aperture synthetic aperture radar (SAR) interferometer to include a second wavelength at the L-band. Adding the second wavelength invites comparison of wavelength-diverse effects in topographic mapping of surfaces, with the principal goal of understanding the penetration of the radar signals in vegetation canopies, and determining the inferred topographic height. A first analysis of these data was conducted at two sites. Elkhorn Slough near Monterey, California presented flat, vegetation free terrain required for calibrating the radar interferometer parameters. A second site stretching from San Jose to Santa Cruz, California, which is heavily vegetated, provided the first test case for wavelength diverse penetration studies. Preliminary results show that: (a) the interferometer calibration determined at Elkhorn Slough is extenable to Laurel Quad and gives confidence in the C- and L-band height measurements; (b) Clear differences were observed between the C- and L-band heights associated with vegetation, with the C-band derived topographic heights generally higher than those from L-band. The noise level in the L-band interferometer is presently the limiting factor in penetration studies.

Rosen, Paul A.

Characterization of exozodiacal dust with the Keck interferometer, VLTI, and SIM

This overview discusses three interferometers for characterization of exozodiacal dust: Keck Interferometer, the Very Large Telescope Interferometer (VLTI), and the Space Interferometry Mission (SIM). The emphasis will be toward the Keck Interferometer, as exozodiacal dust characterization is one of its science requirements.

Colavita, Mark

Sensitivity of nulling interferometers to extra-solar zodiacal emission (EZE)

It should be possible to discover and to analyze the atmospheres of Earth-like planets of nearby stars, provided their thermal emission is not overwhelmed by a bright zodiacal cloud in the same system. Nulling interferometers in space, such as the Terrestrial Planet Finder, can efficiently suppress a stellar point source, but there is no way to suppress diffuse emission underlying the planet under study. A cloud much brighter than solar level would cause serious reduction in sensitivity, by its photon shot noise. Since some clouds have been detected that are orders of magnitude brighter, zodiacal measurements of TPF candidates to solar level are critically needed. These could be obtained relatively soon with the largest aperture ground-based interferometers observing in the 10 micron atmospheric window. A cloud would be detectable as an infrared excess, provided the stellar emission (some 10(exp 4) times brighter) is adequately suppressed by destructive interference. Ideally, the ground interferometer should have angular response similar to that of TPF, so as to measure directly the troublesome zodiacal component. The individual elements must be large, for even with approx. 8 m apertures, star cancellation and low thermal background, integration times of at least several hours will be needed to sense the clouds against shot noise from telescope thermal emission. In this paper we compare the sensitivity of TPF and ground based interferometers to a twin of the solar system at 10 pc, using Good's (1994) model of the zodiacal cloud.

Angel, Roger